{"title":"Miniature Circuit Breaker","description":"\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eBuy Miniature Circuit Breaker (MCB) Online: Your Guide to Electrical MCB Breakers\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMiniature Circuit Breakers, commonly referred to as MCBs or Automatic Circuit Breakers, are the fundamental components of any modern electrical installation. These compact devices play a crucial role in safeguarding circuits against damage caused by excess current, which typically results from either an overload or a short circuit. When fault conditions arise, the Electrical MCB Breaker automatically interrupts the current flow, isolating the faulty circuit and protecting equipment and wiring from thermal damage. At Stoklink, we provide a comprehensive range of these critical safety components from industry-leading manufacturers, ensuring the reliability and protection of your residential, commercial, or industrial applications.  \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eChoosing the Right MCB: Tripping Characteristics and MCB Types\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eChoosing the right \u003c\/span\u003e\u003ca href=\"https:\/\/stoklink.com\/collections\/miniature-circuit-breaker\"\u003e\u003cspan\u003eMCB\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e involves more than simply matching the nominal current. You must also consider the device's operational characteristics and how quickly it responds to different types of faults. The two main mechanisms inside an MCB—the thermal release for overload protection and the magnetic release for short-circuit protection—work together to ensure comprehensive circuit safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eMCB Tripping Curves (B, C, D) for Short-Circuit Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe tripping characteristic, or curve (B, C, or D), defines the instantaneous trip level of the magnetic release. This level determines how fast the MCB trips when a short-circuit fault occurs:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eType B: Trips between 3 and 5 times the rated current. Ideal for purely resistive loads or circuits with very low surge currents, such as residential and light commercial lighting circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eType C: Trips between 5 and 10 times the rated current. This is the most common MCB type and is used for circuits with medium inrush current, typically covering most commercial and residential applications, including motors, appliances, and fluorescent lighting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eType D: Trips between 10 and 20 times the rated current. Suitable for loads with high inrush currents, like transformers, X-ray machines, and specialized industrial equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eUnderstanding the breaking capacity (measured in kA) is also vital. This value indicates the maximum fault current the breaker can safely interrupt. Many of the products we stock offer high breaking capacities, ensuring reliable performance even in robust industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eMCB Current Ratings: From MCB 6A and 10A to MCB 32A\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe nominal current rating is the maximum current an \u003c\/span\u003e\u003ca href=\"https:\/\/stoklink.com\/collections\/miniature-circuit-breaker\"\u003e\u003cspan\u003eAutomatic Circuit Breaker \u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003ecan carry continuously. At Stoklink, you will find a full range of ratings tailored to various wire sizes and load types. For instance, circuits dedicated to lighting might require a lower capacity like an MCB 6A or MCB 10A, whereas power circuits feeding heavier appliances, ovens, or large HVAC units may demand higher capacities like an MCB 16A or even an MCB 32A. Properly matching the rating prevents both wire overheating (overload) and nuisance tripping. For example, an MCB 16A unit is a popular choice for intermediate power circuits, offering robust protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eTop Brands: ABB MCB, Schneider MCB, and Siemens MCB Breakers\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWhen investing in electrical protection, the manufacturer's reputation matters. We source our \u003c\/span\u003e\u003ca href=\"https:\/\/stoklink.com\/collections\/miniature-circuit-breaker\"\u003e\u003cspan\u003eMiniature Circuit Breakers\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e from globally recognized leaders who consistently deliver high-quality, certified products.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eThe Reliable ABB MCB: System Pro M Compact Series\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eABB is synonymous with robust electrical protection. The ABB MCB portfolio offers versatile solutions known for their ease of installation and high operational safety. Their products, designed as part of ranges like the System pro M compact, provide high performance with features such as clear contact position indication and robust terminal design.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eSchneider MCB: Acti9 and Easy9 Automatic Circuit Breaker Solutions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003ca href=\"https:\/\/stoklink.com\/collections\/miniature-circuit-breaker\"\u003e\u003cspan\u003eMCB Schneider\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Electric's offerings, such as the premium Acti9 range, set industry benchmarks for safety and efficiency. Features like VisiTrip, which provide a clear indication of a faulted circuit, help reduce downtime. For essential protection in residential and small commercial buildings, the Easy9 series offers reliable and economical performance. Their reliable C-curve protection, such as in an MCB 32A model, is suitable for demanding branch circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eSiemens MCB: Precision Engineering for Overcurrent Protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe Siemens portfolio offers precision engineering for reliable overcurrent protection. Siemens MCB units are designed for quick installation and highly accurate tripping in industrial control panels and infrastructure projects, ensuring consistent system uptime and long-term durability.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eFactors Influencing MCB Price and Best Value Selection\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe final \u003c\/span\u003e\u003ca href=\"https:\/\/stoklink.com\/collections\/miniature-circuit-breaker\"\u003e\u003cspan\u003eMCB price\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e is determined by several factors, including the manufacturer, the short-circuit breaking capacity (kA), the number of poles (single, double, triple, or four-pole), and the specific certifications required. While it might be tempting to opt for the lowest initial cost, investing in proven brands like ABB, Schneider, and Siemens ensures compliance, longevity, and, most importantly, electrical safety. Whether you require a specialized MCB 6A unit for a single device or a high-capacity MCB 32A for an industrial sub-distribution board, quality should always be the priority. Our detailed product specifications and filters help you quickly compare options and find the best Electrical MCB Breaker solution for your budget and technical requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eFind Your Ideal Miniature Circuit Breaker at Stoklink\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe safety and efficiency of any electrical setup hinge on the quality of its protective devices. Stoklink provides a comprehensive catalog of Miniature Circuit Breakers, ranging from specialized 6A to robust 63A units, featuring the best in class from ABB, Schneider Electric, and Siemens. Don't compromise on circuit protection; explore our current range, compare competitive MCB price options, and select the ideal Automatic Circuit Breaker to ensure compliance and peace of mind for your project. You can discover the complete\u003c\/span\u003e\u003ca href=\"https:\/\/stoklink.com\/collections\/miniature-circuit-breaker\"\u003e\u003cspan\u003e Miniature Circuit Breaker Collection\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e today at Stoklink.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"abb-2ccg000242r0001-scu100-insite-pro-m-compact-accessory","title":"ABB 2CCG000242R0001 SCU100 InSite Pro M Compact Accessory for Low-Voltage Switch Technology","description":"\u003cp\u003eThe ABB SCU100 (2CCG000242R0001) is the InSite Pro M Compact accessory and spare part designed for low-voltage switch technology applications. Part of ABB's InSite series, the SCU100 delivers a compact form factor measuring 161 mm × 87 mm × 64.9 mm and weighing just 329 g, making it well suited for integration into control panels and distribution boards where space and weight are critical considerations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCU100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CCG000242R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInSite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInSite Pro M Compact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory \/ Spare Part for Low-Voltage Switch Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L × W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e161 mm × 87 mm × 64.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e329 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7612271508104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN45555:\u003c\/strong\u003e General methods for assessing the ability of energy-related products to be repaired, reused, and recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive — restricts use of specific hazardous materials in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal and recycling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to applicable European Union health, safety, and environmental protection standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cp\u003eThe ABB SCU100 accessory is intended for use alongside ABB InSite series low-voltage switching devices in industrial automation, motor control centres, control panels, and distribution switchboards. Its compact dimensions and certified compliance make it a reliable choice for procurement engineers sourcing spare parts for maintenance and system upgrades in manufacturing, infrastructure, and building automation environments.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228991230235,"sku":"2CCG000242R0001","price":2738.4,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2ccg000242r0001-scu100-abb-2ccg000242r0001-scu100_1d8e60f0-1ed2-4fcf-8b8d-4216d27860d0.webp?v=1777393271"},{"product_id":"abb-2ccg000243r0001-ins105-5m-plc-connection-cable","title":"ABB 2CCG000243R0001 INS105 5m 9mm Flat Cable PLC Connection Cable InSite Pro M Compact","description":"\u003cp\u003eThe ABB INS105 (SKU: 2CCG000243R0001) is a 5-metre flat PLC connection cable designed for use with the InSite Pro M Compact series, delivering reliable data and signal connectivity in industrial automation and control panel applications. With a slim 9mm profile and a lightweight 42.5 g construction, the INS105 is engineered for clean, space-efficient wiring in demanding industrial environments. Its flat cable design simplifies routing and reduces cable management complexity in tight enclosures.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eINS105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CCG000243R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInSite Pro M Compact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePLC Connection Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.5 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7612271508111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union safety, health, and environmental protection requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC) No 1907\/2006 on chemical substance registration and restriction\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant — free from restricted hazardous materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS – EU Directive 2011\/65\/EU and Amendment 2015\/863:\u003c\/strong\u003e Fully compliant with the updated RoHS directive restricting the use of specific hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment directive for responsible end-of-life disposal and recycling\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConnecting InSite Pro M Compact PLC modules to peripheral devices and I\/O components\u003c\/li\u003e\n\u003cli\u003eControl panel wiring in industrial automation systems\u003c\/li\u003e\n\u003cli\u003eMachine building and system integration projects requiring compact, flat cable routing\u003c\/li\u003e\n\u003cli\u003eFactory automation, process control, and building management installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228991492379,"sku":"2CCG000243R0001","price":16.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2ccg000243r0001-ins105-pro-m-compact_1d4cd1a6-02ba-420a-8157-8e21c82bb86f.webp?v=1777160923"},{"product_id":"abb-2csf204001r3950-f204-ac-125-0-3-4p-125a-rccb","title":"ABB 2CSF204001R3950 F204 AC-125\/0.3 4P 125A 300mA 10kA Residual Current Circuit Breaker","description":"\u003cp\u003eThe ABB F204 AC-125\/0.3 (SKU: 2CSF204001R3950) is a 4-pole residual current circuit breaker from the ABB F200 series, rated at 125A with a 300mA tripping sensitivity and a 10kA breaking capacity at 230\/400V AC. Designed for DIN rail installation, this Type AC RCCB provides reliable earth fault protection in industrial and commercial distribution boards, safeguarding personnel and equipment against dangerous leakage currents.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF204 AC-125\/0.3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CSF204001R3950\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResidual Current Circuit Breaker (RCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Residual Current (IΔn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icn)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72 mm × 85 mm × 69.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8012542941705\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 61008:\u003c\/strong\u003e International standard for residual current operated circuit-breakers without integral overcurrent protection for household and similar uses\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 61008:\u003c\/strong\u003e European harmonised standard equivalent to IEC 61008, confirming compliance for EU markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 61008:\u003c\/strong\u003e Combined IEC and EN certification, confirming dual international and European compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — product is free from restricted hazardous materials including lead, mercury, and cadmium\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU REACH regulation on the registration, evaluation, authorisation, and restriction of chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliance with the Waste Electrical and Electronic Equipment directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEarth fault and personnel protection in three-phase distribution boards and sub-distribution panels\u003c\/li\u003e\n  \u003cli\u003eProtection of outgoing circuits in commercial buildings, factories, and industrial facilities\u003c\/li\u003e\n  \u003cli\u003eMain RCCB for downstream branch circuit protection in TN-S and TT earthing systems\u003c\/li\u003e\n  \u003cli\u003eComplementary use alongside MCBs in residential and light commercial installations requiring high-current RCCB coverage\u003c\/li\u003e\n  \u003cli\u003eControl panel and switchgear assemblies requiring DIN rail-mounted residual current protection at up to 125A\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228994834715,"sku":"2CSF204001R3950","price":412.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2csf204001r3950-current-circuit-breaker_869a5a6f-d3b1-42bc-bb14-715ca0e4a61d.webp?v=1776943629"},{"product_id":"abb-2cds200922r0001-s2c-s-h6r-auxiliary-device","title":"ABB 2CDS200922R0001 S2C-S\/H6R Universal Auxiliary\/Signal Contact 0.5W DIN Rail Auxiliary Device for Distribution Board Devices","description":"\u003cp\u003eThe ABB S2C-S\/H6R (SKU: 2CDS200922R0001) is a universal auxiliary and signal contact designed as an auxiliary device for distribution board devices, delivering reliable switching feedback at just 0.5 W power consumption. Engineered for seamless integration into ABB modular distribution systems, the S2C-S\/H6R provides precise status signalling in control panels and industrial automation environments. Its compact 8.8 × 85 × 69 mm form factor and lightweight 43 g design make it ideal for space-constrained DIN rail installations.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C-S\/H6R\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS200922R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C-S\/H6R\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary Device for Distribution Board Devices\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniversal Auxiliary\/Signal Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.043 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779563819\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH chemical safety regulation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA 22.2 No. 235 \/ GB\/T14048.5 \/ IEC\/EN 60947-5-1 \/ UL 1077:\u003c\/strong\u003e Certified to combined North American and international standards for low-voltage switchgear and control devices\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e Meets European standard for control circuit devices and switching elements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified for safety and performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eStatus signalling and feedback in modular distribution boards\u003c\/li\u003e\n  \u003cli\u003eAuxiliary contact expansion for ABB circuit breakers and modular devices\u003c\/li\u003e\n  \u003cli\u003eControl panel wiring in industrial automation and building management systems\u003c\/li\u003e\n  \u003cli\u003eRemote indication of breaker trip or open\/close status in SCADA and PLC systems\u003c\/li\u003e\n  \u003cli\u003eSpace-efficient DIN rail installations requiring minimal power draw\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229016658203,"sku":"2CDS200922R0001","price":14.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds200922r0001-s2c-s-h6r-distribution-board-devices_96c60a90-e78f-4bc4-8da2-ef54ff4f1205.webp?v=1777160966"},{"product_id":"abb-2cds200912r0001-s2c-h6r-auxiliary-contact","title":"ABB 2CDS200912R0001 S2C-H6R Auxiliary Contact 1CO Auxiliary Device for Distribution Board Devices","description":"\u003cp\u003eThe ABB S2C-H6R (SKU: 2CDS200912R0001) is a 1CO auxiliary contact designed as an auxiliary device for distribution board devices, providing reliable status signalling and interlocking in control panel and industrial automation applications. Part of the ABB S2C series, this compact auxiliary contact measures just 8.8 mm × 85 mm × 69 mm and weighs only 43 g, making it ideal for space-constrained installation environments where precise electrical feedback is required.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C-H6R\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS200912R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779563826\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary Device for Distribution Board Devices\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1CO (1 Change-Over)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.043 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive — no restricted materials in construction\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical safety and substances of concern\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the EU Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Carries CE marking confirming conformity with applicable EU product safety and electromagnetic compatibility directives\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eStatus signalling and position feedback in distribution boards and control panels\u003c\/li\u003e\n  \u003cli\u003eInterlocking circuits in industrial automation and motor control centres\u003c\/li\u003e\n  \u003cli\u003eRemote indication of circuit breaker or switch status in building and infrastructure installations\u003c\/li\u003e\n  \u003cli\u003eIntegration with PLCs and SCADA systems for real-time equipment monitoring\u003c\/li\u003e\n  \u003cli\u003eSpace-constrained switchgear assemblies requiring slim-profile auxiliary contacts\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the S2C-H6R catalog number identify?\u003c\/strong\u003e\u003cbr\u003eS2C-H6R is the customer-facing catalog number printed on ABB datasheets and BOMs. The internal reference number 2CDS200912R0001 is used for ordering and logistics. Both refer to the same product.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is a 1CO contact configuration?\u003c\/strong\u003e\u003cbr\u003e1CO means one change-over contact, which includes one normally open (NO) and one normally closed (NC) contact sharing a common terminal — providing both make and break functionality in a single unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich ABB devices is the S2C-H6R compatible with?\u003c\/strong\u003e\u003cbr\u003eThe S2C-H6R is designed for use with ABB distribution board devices within the S2C series. Please confirm compatibility with the specific host device using the ABB S2C series documentation.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229016953115,"sku":"2CDS200912R0001","price":10.83,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds200912r0001-s2c-h6r-distribution-board-devices_917a63e1-47f3-447c-91e7-5357ff03c2b5.webp?v=1777160956"},{"product_id":"abb-2cds200946r0001-s2c-h6-11r-auxiliary-contact","title":"ABB 2CDS200946R0001 S2C-H6-11R 1NO\/1NC Auxiliary Contact Block for Distribution Board Devices","description":"\u003cp\u003eThe ABB S2C-H6-11R (SKU: 2CDS200946R0001) is a 1NO\/1NC auxiliary contact block designed as an add-on device for ABB distribution board circuit breakers. Part of the S2C series, this compact unit delivers reliable status signalling and remote monitoring capability for control panels and industrial automation systems, with a slim 8.8 mm profile that minimises space consumption on the DIN rail assembly.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C-H6-11R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS200946R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NO + 1NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779697941\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary device for distribution board devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH chemical safety regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e Updated substance restrictions under RoHS 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA 22.2 No. 235:\u003c\/strong\u003e Canadian Standards Association approval for supplementary protectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGB\/T 14048.5:\u003c\/strong\u003e Chinese national standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5-1:\u003c\/strong\u003e International and European standard for control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 1077:\u003c\/strong\u003e UL standard for supplementary protectors for use in electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e European standard for low-voltage switchgear — control circuit devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CSA Group certified for North American markets\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eStatus signalling and remote monitoring of miniature circuit breakers in distribution boards\u003c\/li\u003e\n\u003cli\u003eFeedback indication in building management and industrial control panels\u003c\/li\u003e\n\u003cli\u003eIntegration into SCADA and PLC-based automation systems requiring breaker position feedback\u003c\/li\u003e\n\u003cli\u003eCommercial and industrial electrical installations requiring IEC 60947-5-1 compliant auxiliary contacts\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229017280795,"sku":"2CDS200946R0001","price":12.79,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds200946r0001-s2c-h6-11r-distribution-board-devices_56cfbec3-0e2b-4a91-baba-eab3d9c255e3.webp?v=1777160975"},{"product_id":"abb-2cds200936r0001-s2c-h11l-auxiliary-contact","title":"ABB 2CDS200936R0001 S2C-H11L 1NO\/1NC Left Side Mount Auxiliary Contact for Distribution Board Devices","description":"\u003cp\u003eThe ABB S2C-H11L (SKU: 2CDS200936R0001) is a 1NO\/1NC auxiliary contact block designed for left side mounting on ABB S2C series distribution board devices. Part of the S2C auxiliary device range, the S2C-H11L provides reliable signal feedback and status monitoring for circuit breakers and similar distribution board components in industrial control panel applications. Its compact form factor — just 8.8 mm wide — makes it ideal for space-constrained installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C-H11L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS200936R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NO + 1NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLeft side mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779648820\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive — free from restricted hazardous materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on the registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eStatus signalling and remote indication for distribution board circuit breakers\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels requiring auxiliary switching feedback\u003c\/li\u003e\n\u003cli\u003eBuilding automation and electrical distribution systems\u003c\/li\u003e\n\u003cli\u003eMachine control cabinets where left-side auxiliary contact mounting is required\u003c\/li\u003e\n\u003cli\u003eIntegration with PLC inputs for breaker open\/closed status monitoring\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229017608475,"sku":"2CDS200936R0001","price":12.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds200936r0001-s2c-h11l-distribution-board-devices_e2861b45-1344-46ee-80f2-f307dd512276.webp?v=1777160971"},{"product_id":"abb-2cds200946r0002-s2c-h6-20r-auxiliary-contact","title":"ABB 2CDS200946R0002 S2C-H6-20R 2NO Auxiliary Contact for Distribution Board Devices 1W","description":"\u003cp\u003eThe ABB S2C-H6-20R (SKU: 2CDS200946R0002) is a 2NO auxiliary contact designed as an auxiliary device for distribution board devices, delivering reliable status signalling and interlocking in industrial control panels. Part of ABB's S2C series, the S2C-H6-20R operates at 1 W and features a compact 8.8 mm × 85 mm profile weighing just 0.04 kg, making it ideal for space-constrained distribution board assemblies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C-H6-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS200946R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779697958\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2NO (2 Normally Open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8 mm × 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary device for distribution board devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH chemical safety regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA 22.2 No. 235 \/ GB\/T 14048.5 \/ IEC\/EN 60947-5-1 \/ UL 1077:\u003c\/strong\u003e Certified to combined North American and international standards for low-voltage control devices and supplementary protectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e Compliant with European standard for low-voltage switchgear and controlgear — control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified for industrial electrical equipment\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229017903387,"sku":"2CDS200946R0002","price":12.79,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds200946r0002-s2c-h6-20r-board-devices-1w_3bd48b00-2b72-4de2-8d69-9c74d74dc47f.webp?v=1777160980"},{"product_id":"abb-2cds200946r0003-s2c-h6-02r-2nc-auxiliary-contact","title":"ABB 2CDS200946R0003 S2C-H6-02R 2NC Auxiliary Contact Block for Distribution Board Devices","description":"\u003cp\u003eThe ABB S2C-H6-02R (SKU: 2CDS200946R0003) is a 2NC auxiliary contact block designed for use with ABB distribution board devices, providing reliable signal and status feedback in control panel and industrial automation applications. Part of the S2C series, this compact auxiliary device measures just 8.8 mm × 85 mm × 69 mm and weighs only 0.04 kg, making it ideal for space-constrained installations. With a rated power of 1 W and full compliance with IEC\/EN 60947-5-1, the S2C-H6-02R delivers dependable performance in demanding industrial environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C-H6-02R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS200946R0003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary contact 2NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779697965\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary device for distribution board devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH chemical safety regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA 22.2 No.235 \/ GB\/T14048.5 \/ IEC\/EN 60947-5-1 \/ UL 1077:\u003c\/strong\u003e Certified to North American, Chinese, and international standards for low-voltage control devices and supplementary protectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-5:\u003c\/strong\u003e Compliant with European standard for low-voltage switchgear and controlgear — control circuit devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the EU Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229018165531,"sku":"2CDS200946R0003","price":12.79,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds200946r0003-s2c-h6-02r-distribution-board-devices_c78eeec5-8355-417e-8f3a-abd2e16b7089.webp?v=1777160985"},{"product_id":"abb-2cds200936r0002-s2c-h20l-auxiliary-device","title":"ABB 2CDS200936R0002 S2C-H20L S200 Series DIN Rail Auxiliary Device for Distribution Board Devices","description":"\u003cp\u003eThe ABB S2C-H20L (SKU: 2CDS200936R0002) is a DIN rail-mounted auxiliary device designed for use with ABB S200 series distribution board devices. Part of the trusted ABB S200 accessory range, the S2C-H20L delivers reliable signalling and control integration in compact control panels and distribution boards, consuming just 1 W of power and occupying a slim 8.8 mm installation width.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C-H20L\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS200936R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS200\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary Device for Distribution Board Devices\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8 mm × 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.055 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779648837\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive — restricts the use of specific hazardous materials in electrical and electronic equipment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with the Registration, Evaluation, Authorisation and Restriction of Chemicals regulation — ensures safe handling of chemical substances in the product.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive — supports responsible recycling and disposal of electrical components at end of life.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIntegration with ABB S200 series miniature circuit breakers in distribution boards\u003c\/li\u003e\n  \u003cli\u003eStatus signalling and remote indication in industrial control panels\u003c\/li\u003e\n  \u003cli\u003eBuilding automation and facility management electrical installations\u003c\/li\u003e\n  \u003cli\u003eCommercial and industrial panel board assemblies requiring compact DIN rail accessories\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229018460443,"sku":"2CDS200936R0002","price":14.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds200936r0002-s2c-h20l-abb-2cds200936r0002-s2c-h20l_30ff55c6-3cb0-458b-b8e1-c2bb7a0b2ddc.webp?v=1777393308"},{"product_id":"abb-2cds200936r0003-s2c-h02l-2nc-auxiliary-contact","title":"ABB 2CDS200936R0003 S2C-H02L 2NC Left Side Mount Auxiliary Contact for S200 Series Circuit Breakers","description":"\u003cp\u003eThe ABB S2C-H02L (SKU: 2CDS200936R0003) is a 2NC left-side-mounting auxiliary contact designed for use with ABB S200 series miniature circuit breakers and distribution board devices. This compact auxiliary device provides signal feedback for monitoring and control applications, featuring a 1 W power rating and slim 8.8 mm width to fit neatly alongside standard S200 MCB modules in control panels and distribution boards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C-H02L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS200936R0003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2NC (2 Normally Closed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLeft side mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8 mm × 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.055 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779648844\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive — restricts use of specific hazardous materials in electrical and electronic equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (Registration, Evaluation, Authorisation and Restriction of Chemicals) — ensures safe chemical substance management throughout the product lifecycle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive — supports proper recycling and disposal of electrical equipment at end of life.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cp\u003eThe S2C-H02L auxiliary contact is used wherever position or status monitoring of an S200 series MCB is required. Typical applications include building automation systems, industrial control panels, distribution boards, motor protection circuits, and SCADA\/BMS integration where a circuit breaker's open or closed state must be relayed as a signal to a PLC or monitoring system. The left-side mounting design keeps wiring neat and minimises panel footprint.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229018722587,"sku":"2CDS200936R0003","price":14.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds200936r0003-s2c-h02l-abb-2cds200936r0003-s2c-h02l_2a4d50c3-ee9d-4d1e-ba7f-41baf39e8fd5.webp?v=1777393312"},{"product_id":"abb-2cds200970r0031-s2c-h01-auxiliary-contact","title":"ABB 2CDS200970R0031 S2C-H01 Bottom-Fitting 1NC Auxiliary Contact for Distribution Board Devices","description":"\u003cp\u003eThe ABB S2C-H01 (SKU: 2CDS200970R0031) is a bottom-fitting auxiliary contact block designed for use with ABB distribution board devices, providing a single normally-closed (1NC) contact signal output for monitoring and control applications. Rated at 0.5 W and weighing just 8 g, the S2C-H01 offers compact, reliable status feedback in panel-mount installations where space is at a premium.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C-H01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS200970R0031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NC (1 Normally Closed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBottom-fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.4 mm × 21.2 mm × 23.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.008 kg (8 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779065108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive, ensuring the product is free from restricted hazardous materials.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with the EU REACH regulation governing chemicals used in electrical and electronic equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal and recycling.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eStatus monitoring of ABB distribution board circuit breakers and residual current devices\u003c\/li\u003e\n\u003cli\u003eRemote indication of device trip or open\/closed state in building management and industrial control panels\u003c\/li\u003e\n\u003cli\u003eIntegration with PLC inputs and SCADA systems for automated fault detection\u003c\/li\u003e\n\u003cli\u003eAuxiliary signalling in motor control centres and switchboards\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229019377947,"sku":"2CDS200970R0031","price":6.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds200970r0031-s2c-h01-distribution-board-devices_124c665b-b361-49a0-98a1-9cedf30b9422.webp?v=1777160992"},{"product_id":"abb-2cds200970r0032-s2c-h10-auxiliary-contact","title":"ABB 2CDS200970R0032 S2C-H10 Bottom-Fitting Auxiliary Contact 1NO Auxiliary Device for Distribution Board Devices","description":"\u003cp\u003eThe ABB S2C-H10 (SKU: 2CDS200970R0032) is a bottom-fitting auxiliary contact block rated 1NO, designed as an auxiliary device for distribution board devices in industrial control and automation panels. Part of ABB's S2C series, this compact add-on contact delivers reliable signal feedback and monitoring capability with a low power consumption of just 0.5 W, making it ideal for integration into space-constrained distribution boards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C-H10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS200970R0032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779065139\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NO (1 Normally Open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBottom-fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.4 mm × 21.2 mm × 23.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.008 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary device for distribution board devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA 22.2 No.235 \/ GB\/T14048.5 \/ UL1077:\u003c\/strong\u003e Certified to North American, Chinese, and international supplementary protector standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive for responsible disposal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified for safety and performance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSignal feedback and status monitoring in distribution boards\u003c\/li\u003e\n\u003cli\u003eAuxiliary contact extension for miniature circuit breakers and modular devices\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels and building automation systems\u003c\/li\u003e\n\u003cli\u003eMachine control wiring and PLC interlocking circuits\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eWhat devices is the S2C-H10 compatible with?\u003c\/strong\u003e\u003cbr\u003eThe S2C-H10 is a bottom-fitting auxiliary contact designed for use with ABB S2C series distribution board devices.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the contact configuration of the S2C-H10?\u003c\/strong\u003e\u003cbr\u003eIt provides 1NO (one Normally Open) contact for auxiliary switching and signalling functions.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the S2C-H10 mounted?\u003c\/strong\u003e\u003cbr\u003eThe S2C-H10 is bottom-fitted to the host device, allowing space-efficient installation within distribution boards.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229019640091,"sku":"2CDS200970R0032","price":6.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds200970r0032-s2c-h10-distribution-board-devices_4a67174d-caa5-4b89-a2db-ca3f71d4834f.webp?v=1777160996"},{"product_id":"abb-2cds200909r0001-s2c-a1-shunt-trip-auxiliary-device","title":"ABB 2CDS200909R0001 S2C-A1 Shunt Trip 12-110V Auxiliary Device for Distribution Board Devices","description":"\u003cp\u003eThe ABB S2C-A1 (SKU: 2CDS200909R0001) is a shunt trip auxiliary device designed for use with ABB distribution board circuit breakers, enabling remote electrical tripping across a wide operating voltage range of 12 to 110V AC\/DC. The S2C-A1 integrates directly with compatible ABB MCBs and distribution board devices, providing reliable remote-trip functionality in control panels, motor control centres, and industrial automation installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C-A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS200909R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShunt Trip Auxiliary Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12...110V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 x 74 x 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.133 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779570992\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with European Union directives for electrical equipment safety and EMC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substance safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Certified by the Canadian Standards Association for electrical safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA 22.2 No.235 \/ UL 1077:\u003c\/strong\u003e Certified to North American supplementary protectors standard for distribution board accessory devices\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRemote electrical tripping of ABB miniature circuit breakers in distribution boards\u003c\/li\u003e\n\u003cli\u003eEmergency shutdown circuits in industrial control panels\u003c\/li\u003e\n\u003cli\u003eBuilding automation and energy management systems requiring remote breaker trip capability\u003c\/li\u003e\n\u003cli\u003eMotor control centres and machine safety circuits\u003c\/li\u003e\n\u003cli\u003eFire alarm and safety interlock systems connected to distribution board breakers\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229019935003,"sku":"2CDS200909R0001","price":25.18,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds200909r0001-s2c-a1-distribution-board-devices_f2475c49-e014-4bfc-b55c-fbfa9fd5cbf4.webp?v=1777160946"},{"product_id":"abb-2cds200909r0002-s2c-a2-shunt-trip-auxiliary-device","title":"ABB 2CDS200909R0002 S2C-A2 Shunt Trip 110-415V Auxiliary Device for Distribution Board Circuit Breakers","description":"\u003cp\u003eThe ABB S2C-A2 (SKU: 2CDS200909R0002) is a shunt trip auxiliary device designed for integration with ABB distribution board circuit breakers, enabling remote electrical tripping across a wide rated voltage range of 110–415V AC. Part of the ABB S2C series, the S2C-A2 provides reliable remote de-energisation for safety interlocking, fire alarm integration, and automated shutdown in industrial and commercial control panel applications. Its compact form factor — 17.5 × 85 × 74 mm — allows easy installation in space-constrained distribution boards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C-A2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS200909R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShunt Trip Auxiliary Device for Distribution Board Devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110–415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 × 85 × 74 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.133 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779571005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to applicable European Union directives for electrical equipment safety and electromagnetic compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking, confirming compliance with Great Britain market regulations post-Brexit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive — free from restricted materials including lead, mercury, and cadmium.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances used in product manufacturing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive for responsible end-of-life recycling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA 22.2 No.235 \/ UL 1077:\u003c\/strong\u003e Certified to North American standards for supplementary protectors and auxiliary devices, suitable for CSA\/UL-listed panel assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRemote electrical tripping of distribution board circuit breakers via fire alarm or BMS signal\u003c\/li\u003e\n\u003cli\u003eSafety interlocking in industrial control panels and switchboards\u003c\/li\u003e\n\u003cli\u003eAutomated emergency shutdown systems in commercial and industrial facilities\u003c\/li\u003e\n\u003cli\u003eIntegration with building automation and energy management systems\u003c\/li\u003e\n\u003cli\u003eUL\/CSA-listed panel assemblies requiring North American compliant auxiliary devices\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229020098843,"sku":"2CDS200909R0002","price":25.18,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds200909r0002-s2c-a2-board-circuit-breakers_8fcd12fc-1eca-45b5-808f-ac509d78407c.webp?v=1777160952"},{"product_id":"abb-2cds200918r0001-s2c-nt-neutral-accessory-s200","title":"ABB 2CDS200918R0001 S2C-NT Hand Operated Neutral Accessory for S200 Series Low-Voltage Circuit Breakers","description":"\u003cp\u003eThe ABB S2C-NT (SKU: 2CDS200918R0001) is a hand-operated neutral accessory designed for use with ABB S200 series low-voltage circuit breakers, enabling precise neutral conductor switching and control in panel assemblies. Rated at 2 W and DIN rail mountable, the S2C-NT delivers reliable performance in industrial control panels, distribution boards, and automation enclosures. With compact dimensions of 8.8 mm × 85 mm × 69 mm and a lightweight 59 g construction, it integrates seamlessly into space-constrained installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C-NT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS200918R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2C-NT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHand Operated Neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessory \/ Spare Part for Low-Voltage Switch Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.8 mm × 85 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.059 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779647625\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with Restriction of Hazardous Substances Directive — restricts use of specific hazardous materials in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 — addressing the safe use of chemical substances in products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e Meets the European RoHS Directive governing hazardous substance restrictions in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e Compliant with EU Delegated Directive 2015\/863, which updated Annex II of 2011\/65\/EU with additional restricted substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with Waste Electrical and Electronic Equipment Directive — supports proper end-of-life recycling and disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNeutral conductor hand operation in S200 series miniature circuit breaker assemblies\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels and distribution boards requiring neutral switching accessories\u003c\/li\u003e\n\u003cli\u003eAutomation enclosures and machine control cabinets with DIN rail infrastructure\u003c\/li\u003e\n\u003cli\u003ePanel builders seeking compact, certified low-voltage switch technology accessories\u003c\/li\u003e\n\u003cli\u003eRetrofit and spare-part replacement for existing ABB S200 series installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229020492059,"sku":"2CDS200918R0001","price":7.89,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds200918r0001-s2c-nt-low-voltage-circuit-breakers_0755e6e2-fa46-41e3-b48f-2f8869f6a722.webp?v=1777160961"},{"product_id":"abb-2ccs800900r0021-s800-aux-alt-auxiliary-contact","title":"ABB 2CCS800900R0021 S800-AUX\/ALT Auxiliary\/Signal Contact Block 50kA DIN Rail Mount","description":"\u003cp\u003eThe ABB S800-AUX\/ALT (SKU: 2CCS800900R0021) is an auxiliary and signal contact block designed for use with ABB S800 series circuit breakers, providing reliable status indication and remote signalling in industrial control panels. The S800-AUX\/ALT delivers a breaking capacity of 50 kA at 415V AC and mounts directly to DIN rail for quick, tool-free installation in compact switchgear assemblies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS800-AUX\/ALT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CCS800900R0021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary \/ Signal Contact Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA @ 415V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e53 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7612271206819\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive, confirming the product is free from restricted materials.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances, safe for use in European markets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1 \/ UL 489:\u003c\/strong\u003e Tested and certified to international standards for low-voltage control circuit devices and switching elements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Meets IEC requirements for control circuit devices used in industrial switching applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive for proper end-of-life disposal and recycling.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eStatus indication and fault signalling for ABB S800 series miniature circuit breakers in LV switchboards\u003c\/li\u003e\n\u003cli\u003eRemote monitoring of breaker tripped\/open\/closed state in building management and industrial automation systems\u003c\/li\u003e\n\u003cli\u003eIntegration with PLCs and SCADA systems requiring auxiliary contact feedback from circuit protection devices\u003c\/li\u003e\n\u003cli\u003eMachine control panels, motor control centres (MCCs), and distribution boards requiring compact DIN rail accessories\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229020557595,"sku":"2CCS800900R0021","price":27.51,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2ccs800900r0021-s800-aux-alt-din-rail-mount_2ffed425-a7f8-4de6-b2fe-ab7ecef98af6.webp?v=1777160933"},{"product_id":"abb-2ccs800900r0011-s800-aux-auxiliary-contact-block","title":"ABB 2CCS800900R0011 S800-AUX Auxiliary Contact Block DIN-Rail Mount for S800 Series Circuit Breakers","description":"\u003cp\u003eThe ABB S800-AUX (SKU: 2CCS800900R0011) is a DIN-rail mounted auxiliary contact block designed for use with ABB's S800 series miniature circuit breakers, providing essential status signalling and remote monitoring capability in industrial control panels and distribution boards. Compact at just 9 mm wide, the S800-AUX integrates directly alongside S800 series breakers to report open\/closed switching states to control systems, PLCs, and supervisory equipment. Weighing only 50 g, it is engineered for panel-space efficiency without compromising reliability.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS800-AUX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CCS800900R0011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuxiliary Contact Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN-Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7612271206802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive — no restricted heavy metals or substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical safety and substance management\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5-1 \/ UL 489:\u003c\/strong\u003e Meets international standards for control circuit devices and switching elements, as well as UL 489 for molded-case circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-5:\u003c\/strong\u003e Compliant with IEC standard for low-voltage switchgear and controlgear — control circuit devices and switching elements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive for responsible end-of-life recycling\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRemote status monitoring of S800 series miniature circuit breakers in industrial control panels\u003c\/li\u003e\n\u003cli\u003eFault indication and alarm signalling in building management and automation systems\u003c\/li\u003e\n\u003cli\u003ePLC input signal generation for breaker trip or open\/close status in motor control centres\u003c\/li\u003e\n\u003cli\u003eIntegration into supervisory control and data acquisition (SCADA) systems for real-time breaker state feedback\u003c\/li\u003e\n\u003cli\u003ePanel builders requiring compact auxiliary signalling alongside standard DIN-rail breaker assemblies\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229020655899,"sku":"2CCS800900R0011","price":25.71,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2ccs800900r0011-s800-aux-series-circuit-breakers_87c2d97b-9f1b-4955-b6b7-0a69b7631f2e.webp?v=1777160928"},{"product_id":"abb-2ccs800900r0211-s800-sor250-shunt-operation-release","title":"ABB 2CCS800900R0211 S800-SOR250 110-250V 23-119W Shunt Operation Release","description":"\u003cp\u003eThe ABB S800-SOR250 (SKU: 2CCS800900R0211) is a shunt operation release designed for use with ABB S800 series circuit breakers, enabling remote electrical tripping of the breaker from a rated voltage of 110 to 250 V AC\/DC with a power consumption of 23 to 119 W. The S800-SOR250 is an essential accessory for control panel designers and system integrators who require reliable remote trip functionality in industrial automation and power distribution applications. Weighing only 0.17 kg, this compact release installs directly onto compatible S800 series breakers for seamless integration.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS800-SOR250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CCS800900R0211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShunt Operation Release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 ... 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 ... 119 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7612271208332\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive, confirming the product is free from restricted hazardous materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (Registration, Evaluation, Authorisation and Restriction of Chemicals), ensuring safe chemical substance management\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229020721435,"sku":"2CCS800900R0211","price":44.93,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2ccs800900r0211-s800-sor250-shunt-operation-release_d7555181-c25d-4450-af70-2bd802ba9858.webp?v=1777160937"},{"product_id":"abb-2cdl200001r0001-ps-end-phase-busbar-end-cap","title":"ABB 2CDL200001R0001 PS-END End Cap Phase Busbar Accessory 18mm CE RoHS","description":"\u003cp\u003eThe ABB PS-END (2CDL200001R0001) is a genuine ABB end cap designed to terminate and protect phase busbars in industrial control panel assemblies. The PS-END provides a secure, insulating closure at the end of busbar runs, preventing accidental contact and ensuring compliance with electrical safety standards. Compact at 18 mm × 17 mm × 8 mm and weighing just 1 g, it integrates seamlessly into ABB busbar systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePS-END\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDL200001R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779514729\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Busbar End Cap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to applicable European Union directives for electrical equipment safety and electromagnetic compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances directive — free from restricted hazardous materials.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Meets EU REACH regulation requirements regarding chemical substance safety in electrical components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment directive for responsible end-of-life disposal and recycling.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTerminating exposed ends of ABB PS-series phase busbars in control panels and distribution boards\u003c\/li\u003e\n\u003cli\u003eProviding IP-rated insulation protection at busbar ends to prevent accidental live contact\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and motor control centre (MCC) panel builds requiring tidy, compliant busbar installations\u003c\/li\u003e\n\u003cli\u003eOEM panel builders and system integrators working with ABB busbar distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229021180187,"sku":"2CDL200001R0001","price":0.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cdl200001r0001-ps-end-18mm-ce-rohs_6456cdfc-a6e1-470b-89d8-bd654d487112.webp?v=1777160941"},{"product_id":"abb-2cds631031r0105-bms311b10-1p-10a-mcb","title":"ABB 2CDS631031R0105 BMS311B10 1P 10A B-Curve 3kA 230V DIN Rail Miniature Circuit Breaker (MCB)","description":"\u003cp\u003eThe ABB BMS311B10 miniature circuit breaker (SKU: 2CDS631031R0105) is a 1-pole, 10A, B-curve MCB from the Basic M BMS series, rated at 230V AC per IEC 60898-1 and designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panels. With a breaking capacity of 3 kA at 230\/400V AC and compact DIN rail mounting dimensions of 17.5mm wide, the BMS311B10 delivers dependable protection in space-constrained enclosures.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311B10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 230\/400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers (industrial applications)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European adoption of insulation coordination requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General standard series for circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e General standard series for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant — restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant — registration, evaluation, authorisation and restriction of chemicals (EU regulation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant — waste electrical and electronic equipment directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical panels and sub-distribution boards\u003c\/li\u003e\n\u003cli\u003eLight industrial control panels and machinery protection\u003c\/li\u003e\n\u003cli\u003eProtection of lighting circuits, socket outlet circuits, and small motor loads (B-curve)\u003c\/li\u003e\n\u003cli\u003eDIN rail installations requiring compact 17.5mm single-pole breakers\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the B-curve mean for the BMS311B10?\u003c\/strong\u003e The B-curve trips the breaker at 3–5× the rated current for instantaneous protection, making it ideal for resistive and lightly inductive loads such as lighting and socket circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the ABB BMS311B10 compliant with IEC 60898-1?\u003c\/strong\u003e Yes. The BMS311B10 is fully certified to IEC 60898-1 for household and similar installations, as well as IEC 60947-2 for industrial applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan the BMS311B10 be used on a 400V system?\u003c\/strong\u003e Per IEC 60947-2, the rated voltage extends to 440V, giving it flexibility for industrial 3-phase distribution systems when used as a single-pole device.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229167161627,"sku":"2CDS631031R0105","price":1.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0105-bms311b10-circuit-breaker-mcb_24b0fd56-1b38-4f99-854b-ba9671b49719.webp?v=1777162297"},{"product_id":"abb-2cds631031r0165-bms311b16-1p-16a-3ka-mcb","title":"ABB 2CDS631031R0165 BMS311B16 1P 16A 3kA B-Curve Miniature Circuit Breaker MCB 230V AC","description":"\u003cp\u003eThe ABB BMS311B16 (SKU: 2CDS631031R0165) is a 1-pole 16A miniature circuit breaker (MCB) from the Basic M BMS series, designed for reliable overcurrent and short-circuit protection in residential and light commercial installations. Rated at 230V AC per IEC 60898-1 and 440V per IEC 60947-2, the BMS311B16 delivers a breaking capacity of 3 kA at 230\/400V AC, making it a dependable choice for standard distribution boards and control panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311B16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0165\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC (IEC 60898-1) \/ 440 V (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu\/Ics)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043328\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e General insulation coordination standard for low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General series standard for circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e General series standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH chemical safety regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eLight commercial and industrial control panel protection\u003c\/li\u003e\n\u003cli\u003eSingle-phase circuit protection in building installations\u003c\/li\u003e\n\u003cli\u003eDIN rail mounted branch circuit protection up to 16A\u003c\/li\u003e\n\u003cli\u003eFinal circuit protection in automation and control cabinets\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229167358235,"sku":"2CDS631031R0165","price":1.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0165-bms311b16-mcb-230v-ac_fc592a50-db19-471b-8d86-d716056e3b1a.webp?v=1777162309"},{"product_id":"abb-2cds631031r0065-bms311b06-1p-6a-mcb","title":"ABB 2CDS631031R0065 BMS311B06 1P 6A B-Curve 3kA 230V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311B06 (SKU: 2CDS631031R0065) is a 1-pole, 6A, B-curve miniature circuit breaker (MCB) from the Basic M BMS series, designed for reliable overcurrent and short-circuit protection in residential and light commercial control panels. Rated at 230V AC per IEC 60898-1 and 440V AC per IEC 60947-2, the BMS311B06 delivers a breaking capacity of 3 kA and fits into compact installations with its slim 17.5mm wide DIN rail profile.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311B06\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0065\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779038010\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar installations — circuit breakers for overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination — general requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit breakers for overcurrent protection for household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS (EU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863):\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Toxic Substances Control Act compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste electrical and electronic equipment directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eControl panel protection in light commercial and industrial automation applications\u003c\/li\u003e\n  \u003cli\u003eBranch circuit protection for lighting and low-load circuits\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting in compact electrical enclosures\u003c\/li\u003e\n  \u003cli\u003eProtection of sensitive electrical components requiring B-curve characteristics\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229168079131,"sku":"2CDS631031R0065","price":2.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0065-bms311b06-miniature-circuit-breaker_50db70e7-8e00-4b05-9d75-c71733f8ab5c.webp?v=1777162285"},{"product_id":"abb-2cds631031r0255-bms311b25-1p-25a-3ka-mcb","title":"ABB 2CDS631031R0255 BMS311B25 1P 25A 3kA B-Curve 230V AC Miniature Circuit Breaker MCB","description":"\u003cp\u003eThe ABB BMS311B25 (SKU: 2CDS631031R0255) is a 1-pole 25A B-curve miniature circuit breaker (MCB) from the Basic M BMS series, rated at 230V AC per IEC 60898-1 and 440V per IEC 60947-2. Delivering a breaking capacity of 3 kA, this compact BMS311B25 unit is engineered for reliable overcurrent protection in residential, commercial, and light industrial control panel applications, housed in a slim 17.5mm wide DIN rail-mountable enclosure weighing just 93g.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311B25\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0255\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043489\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standards for low-voltage installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European adoption of insulation coordination standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General circuit breaker protection standard series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear standards series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances (EC 1907\/2006)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Compliant with US Toxic Substances Control Act requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial building electrical panels and sub-distribution boards\u003c\/li\u003e\n  \u003cli\u003eLight industrial control panels and machinery protection\u003c\/li\u003e\n  \u003cli\u003eBranch circuit protection for lighting and socket circuits\u003c\/li\u003e\n  \u003cli\u003eDIN rail installations in compact enclosures where a slim 17.5mm profile is essential\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229168668955,"sku":"2CDS631031R0255","price":1.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0255-bms311b25-circuit-breaker-mcb_b51f9917-e69f-48f4-8a36-58149695cdde.webp?v=1777162333"},{"product_id":"abb-2cds631031r0205-bms311b20-1p-20a-3ka-mcb","title":"ABB 2CDS631031R0205 BMS311B20 1P 20A 3kA B-Curve Miniature Circuit Breaker Basic M BMS Series","description":"\u003cp\u003eThe ABB BMS311B20 miniature circuit breaker (MCB), catalog number BMS311B20, SKU 2CDS631031R0205, is a 1-pole, 20 A, B-curve device from the Basic M BMS series offering 3 kA breaking capacity at 230\/400 V AC. Rated to both IEC 60898-1 (domestic\/commercial) and IEC 60947-2 (industrial) standards, it delivers reliable overcurrent and short-circuit protection in a compact 17.5 mm wide DIN-rail-mount housing — ideal for control panels, distribution boards, and industrial automation enclosures.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311B20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0205\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043403\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu\/Ics)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear — circuit breakers for industrial applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e General insulation coordination standard for low-voltage equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear general standards framework\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — compliant with applicable EU directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from restricted materials per EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — proper end-of-life disposal classification\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection in residential and commercial distribution boards\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panel circuit protection in automation and machinery enclosures\u003c\/li\u003e\n  \u003cli\u003eBranch circuit protection for lighting, HVAC, and general-purpose loads\u003c\/li\u003e\n  \u003cli\u003eProtection of cables and conductors in DIN-rail-mounted assemblies\u003c\/li\u003e\n  \u003cli\u003eCompact single-pole protection where space is limited (17.5 mm pitch)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229170176283,"sku":"2CDS631031R0205","price":1.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0205-bms311b20-m-bms-series_0cc8f124-685c-42ca-b9f8-e1c57dc28f46.webp?v=1777162321"},{"product_id":"abb-2cds633031r0205-bms313b20-3p-20a-mcb","title":"ABB 2CDS633031R0205 BMS313B20 3P 20A 3kA 400V AC B-Curve Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS313B20 (SKU: 2CDS633031R0205) is a 3-pole 20 A B-curve miniature circuit breaker from the Basic M BMS series, rated at 400 V AC with a breaking capacity of 3 kA per IEC 60898-1. Designed for compact residential and light commercial distribution boards, the BMS313B20 delivers reliable overcurrent and short-circuit protection in a slim 52.5 mm-wide, DIN-rail-mount format — making it an ideal choice for engineers and panel builders seeking cost-effective, standards-compliant circuit protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313B20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044844\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Rated and tested as a household and similar installation circuit breaker\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Compliant as an industrial low-voltage circuit breaker (440 V AC rating)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e General insulation coordination standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Core circuit-breaker performance standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear standard family\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets all applicable EU directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant, free of restricted materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Toxic Substances Control Act — compliant for US market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive — registered and compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eLight commercial and industrial control panel circuit protection\u003c\/li\u003e\n\u003cli\u003eBranch circuit protection for lighting and general-purpose loads\u003c\/li\u003e\n\u003cli\u003eDIN-rail-mount installations requiring compact 3-pole switching\u003c\/li\u003e\n\u003cli\u003eApplications demanding IEC 60898-1 and IEC 60947-2 dual compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229171650843,"sku":"2CDS633031R0205","price":8.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0205-bms313b20-miniature-circuit-breaker_b75074e3-63be-4b24-bdf7-e2a86e70e0be.webp?v=1777162480"},{"product_id":"abb-2cds633031r0105-bms313b10-3p-10a-mcb","title":"ABB 2CDS633031R0105 BMS313B10 3P 10A 3kA B-Curve 400V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS313B10 (SKU: 2CDS633031R0105) is a 3-pole 10A B-curve miniature circuit breaker from the Basic M BMS series, rated at 400V AC with a breaking capacity of 3 kA per IEC 60898-1. Designed for reliable overcurrent and short-circuit protection in industrial control panels and building electrical installations, the BMS313B10 delivers compact, DIN rail-mountable performance with a 52.5 × 88 × 69 mm footprint and a total weight of just 279 g.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313B10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044684\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e International standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e International standard for low-voltage switchgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear standard family\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar circuit breaker performance standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marking — meets EU electrical equipment directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU chemicals regulation (EC) No 1907\/2006\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Compliant with US Toxic Substances Control Act requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant — supports responsible disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in industrial control panels and automation cabinets\u003c\/li\u003e\n\u003cli\u003eProtection of branch circuits in commercial and light industrial building installations\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting in distribution boards and motor control centres\u003c\/li\u003e\n\u003cli\u003eSuitable for resistive and low-inductive loads requiring B-curve trip characteristics\u003c\/li\u003e\n\u003cli\u003eUse in applications rated up to 400V AC \/ 440V per IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229171781915,"sku":"2CDS633031R0105","price":8.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0105-bms313b10-miniature-circuit-breaker_67472bb9-62f2-4af4-b650-1d1711050b04.webp?v=1777162460"},{"product_id":"abb-2cds631031r0635-bms311b63-1p-63a-3ka-mcb","title":"ABB 2CDS631031R0635 BMS311B63 1P 63A 3kA B-Curve 230V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311B63 miniature circuit breaker (SKU: 2CDS631031R0635) is a 1-pole, 63 A, 3 kA breaking capacity MCB from the Basic M BMS series, designed for reliable overcurrent and short-circuit protection in residential and light commercial installations. Rated at 230 V AC per IEC 60898-1 and 440 V AC per IEC 60947-2, the BMS311B63 offers compact B-curve protection in a slim 17.5 mm wide DIN-rail housing suitable for space-constrained control panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311B63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0635\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043809\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear — circuit breakers for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General circuit breaker performance standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB Certificate (IEC 60898):\u003c\/strong\u003e International CB scheme certification for circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS (EU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863):\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliance with EU Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eLight commercial and industrial control panel circuit protection\u003c\/li\u003e\n\u003cli\u003eFinal circuit protection for lighting and socket outlet circuits\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounted installations requiring compact 17.5 mm single-pole breakers\u003c\/li\u003e\n\u003cli\u003eApplications requiring IEC 60947-2 rated devices up to 440 V AC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229172142363,"sku":"2CDS631031R0635","price":3.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0635-bms311b63-miniature-circuit-breaker_8e3730a7-b2fe-43a2-b87e-e4ce819dce97.webp?v=1777162381"},{"product_id":"abb-2cds633031r0255-bms313b25-3p-25a-mcb","title":"ABB 2CDS633031R0255 BMS313B25 3P 25A 3kA 400V AC B-Curve Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS313B25 miniature circuit breaker (MCB), catalog number BMS313B25 \/ SKU 2CDS633031R0255, is a 3-pole, 25A, B-curve device from the Basic M BMS series rated at 400V AC with a breaking capacity of 3kA. Designed to IEC 60898-1 and IEC 60947-2, it delivers reliable overcurrent and short-circuit protection for residential, commercial, and light industrial control panels. Compact at 52.5 × 88 × 69mm and weighing just 279g, it fits neatly on standard DIN rail installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313B25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0255\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC (IEC 60898-1) \/ 440 V (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044929\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar installations — circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard family compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB Certificate (IEC 60898 \/ IEC 60947):\u003c\/strong\u003e International CB scheme certification for global market acceptance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets all applicable EU directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC) No 1907\/2006\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229172896027,"sku":"2CDS633031R0255","price":8.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0255-bms313b25-miniature-circuit-breaker_34d75de3-f204-4c76-8862-0b52b556da65.webp?v=1777162492"},{"product_id":"abb-2cds631031r0325-bms311b32-1p-32a-mcb","title":"ABB 2CDS631031R0325 BMS311B32 1P 32A B-Curve 3kA 230V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311B32 (SKU: 2CDS631031R0325) is a 1-pole, 32 A, B-curve miniature circuit breaker (MCB) from the Basic M BMS series, rated at 230 V AC per IEC 60898-1 and 440 V AC per IEC 60947-2, with a breaking capacity of 3 kA. Designed for residential, commercial, and light-industrial control panel applications, the BMS311B32 provides reliable overcurrent and short-circuit protection with a compact 17.5 mm wide DIN-rail-mounted footprint weighing only 93 g, making it an efficient choice for space-constrained enclosures.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311B32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043564\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers for industrial use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General requirements for miniature circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU chemical safety regulation (EC) No 1907\/2006\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical panel protection\u003c\/li\u003e\n\u003cli\u003eLight-industrial control panel circuit protection\u003c\/li\u003e\n\u003cli\u003eFinal circuit protection for lighting and socket outlet circuits (B-curve)\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounted switchboard assemblies requiring compact 17.5 mm wide modules\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229175124251,"sku":"2CDS631031R0325","price":2.39,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0325-bms311b32-miniature-circuit-breaker_ed34e4ae-9ab6-4f3f-ba4c-6f272435ff00.webp?v=1777162345"},{"product_id":"abb-2cds631031r0505-bms311b50-1p-50a-mcb","title":"ABB 2CDS631031R0505 BMS311B50 1P 50A 3kA B-Curve Miniature Circuit Breaker MCB Basic M BMS Series","description":"\u003cp\u003eThe ABB BMS311B50 (SKU: 2CDS631031R0505) is a 1-pole, 50 A, B-curve miniature circuit breaker (MCB) from the Basic M BMS series, rated for 230 V AC per IEC 60898-1 and 440 V AC per IEC 60947-2, with a breaking capacity of 3 kA. Designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial installations, the BMS311B50 delivers dependable performance in a compact 17.5 mm wide DIN rail mount package weighing just 93 g.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311B50\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0505\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043724\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers for industrial applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard for low-voltage equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General requirements for circuit breakers for overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU (RoHS 2):\u003c\/strong\u003e European Union restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e EU RoHS amendment restricting additional hazardous substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant with European e-waste regulations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial building electrical panels and consumer units\u003c\/li\u003e\n  \u003cli\u003eLight industrial control panels and machinery protection\u003c\/li\u003e\n  \u003cli\u003eFinal circuit protection for lighting and general power circuits\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounted switchgear assemblies\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229176959259,"sku":"2CDS631031R0505","price":2.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0505-bms311b50-m-bms-series_94b3f39c-372c-4ae1-b271-bf0caed3f3a6.webp?v=1777162368"},{"product_id":"abb-2cds633031r0065-bms313b06-3p-6a-mcb","title":"ABB 2CDS633031R0065 BMS313B06 3P 6A B-Curve 3kA 400V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS313B06 miniature circuit breaker (2CDS633031R0065) is a 3-pole, 6 A, B-curve MCB from the Basic M BMS series, rated at 400 V AC per IEC 60898-1 with a breaking capacity of 3 kA. Designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panels, the BMS313B06 delivers dependable performance in a compact 52.5 × 88 × 69 mm DIN-rail-mounted package weighing just 279 g.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313B06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0065\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTripping Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044608\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for household and similar installations — miniature circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with applicable EU directives for the European Economic Area\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS (EU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863):\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eProtection of lighting circuits in commercial buildings\u003c\/li\u003e\n\u003cli\u003eControl panel protection in light industrial automation environments\u003c\/li\u003e\n\u003cli\u003eMachine and equipment branch-circuit protection where B-curve characteristics are required\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounted installations requiring a compact 3-pole MCB footprint\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229177450779,"sku":"2CDS633031R0065","price":10.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0065-bms313b06-miniature-circuit-breaker_c1a92cc9-de95-4bf5-b6b2-1f8961d8144e.webp?v=1777162447"},{"product_id":"abb-2cds631031r0405-bms311b40-1p-40a-3ka-mcb","title":"ABB 2CDS631031R0405 BMS311B40 1P 40A 3kA B-Curve 230V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311B40 (SKU: 2CDS631031R0405) is a 1-pole, 40A, B-curve miniature circuit breaker (MCB) from the Basic M BMS series, rated at 230V AC per IEC 60898-1 and 440V AC per IEC 60947-2, with a breaking capacity of 3 kA. Designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panel installations, the BMS311B40 delivers compact, DIN-rail-ready performance in a 17.5 mm wide form factor.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0405\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043649\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit breakers for overcurrent protection — general series standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — EU compliant disposal classification\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical panel installations\u003c\/li\u003e\n\u003cli\u003eLight industrial control panels and machinery protection\u003c\/li\u003e\n\u003cli\u003eSingle-phase circuit protection at 230V AC\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting in compact enclosures (17.5 mm pitch)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229177581851,"sku":"2CDS631031R0405","price":2.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0405-bms311b40-miniature-circuit-breaker_a805f16f-a7ff-490d-910a-a1bd03313d34.webp?v=1777162357"},{"product_id":"abb-2cds633031r0325-bms313b32-32a-3p-mcb","title":"ABB 2CDS633031R0325 BMS313B32 3P 32A B-Curve 3kA 400V Miniature Circuit Breaker MCB","description":"\u003cp\u003eThe ABB BMS313B32 miniature circuit breaker (MCB), catalog number BMS313B32 and SKU 2CDS633031R0325, is a 3-pole, 32 A, B-curve device from the Basic M BMS series rated for 400 V AC with a breaking capacity of 3 kA per IEC 60898-1. Designed for cost-effective overcurrent and short-circuit protection in residential, commercial, and light industrial distribution boards, BMS313B32 offers reliable performance in compact DIN rail form factor.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313B32\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0325\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779045001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General series standard for overcurrent circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC60898-1:\u003c\/strong\u003e Household and similar circuit-breaker performance requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e General series standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial building electrical panel protection for lighting and socket circuits\u003c\/li\u003e\n  \u003cli\u003eLight industrial control panels requiring compact 3-pole DIN rail MCBs\u003c\/li\u003e\n  \u003cli\u003eFinal distribution circuits where B-curve tripping characteristics are specified\u003c\/li\u003e\n  \u003cli\u003eCost-optimised installations requiring IEC 60898-1 and IEC 60947-2 dual compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229177680155,"sku":"2CDS633031R0325","price":10.73,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0325-bms313b32-circuit-breaker-mcb_7fa9a25b-b47c-426f-b19d-a36e3cba45fc.webp?v=1777162505"},{"product_id":"abb-2cds631031r0064-bms311c06-1p-6a-3ka-mcb","title":"ABB 2CDS631031R0064 BMS311C06 1P 6A 3kA C-Curve Basic M BMS Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311C06 miniature circuit breaker (SKU: 2CDS631031R0064) is a 1-pole, 6A, C-curve MCB from the Basic M BMS series, rated at 230V AC per IEC 60898-1 and 440V per IEC 60947-2, with a breaking capacity of 3kA. Designed for reliable overcurrent and short-circuit protection in residential and light commercial control panels, the BMS311C06 offers a compact 17.5mm DIN rail footprint suitable for space-constrained installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311C06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0064\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043168\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e International standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General series standard for circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substance safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Compliant with US Toxic Substances Control Act requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under EU Waste Electrical and Electronic Equipment Directive for proper end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eLight commercial and industrial control panel protection\u003c\/li\u003e\n\u003cli\u003eBranch circuit protection for loads up to 6A on single-phase 230V AC systems\u003c\/li\u003e\n\u003cli\u003eDIN rail mounted installations requiring compact 17.5mm width breakers\u003c\/li\u003e\n\u003cli\u003eAutomation and machinery control cabinets requiring IEC 60947-2 rated devices\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229178073371,"sku":"2CDS631031R0064","price":2.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0064-bms311c06-miniature-circuit-breaker_526ea620-2648-4f40-a6dd-981afbf90690.webp?v=1777162280"},{"product_id":"abb-2cds633031r0405-bms313b40-3p-40a-mcb","title":"ABB 2CDS633031R0405 BMS313B40 3P 40A 3kA 400V AC B-Curve Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS313B40 (SKU: 2CDS633031R0405) is a 3-pole 40 A B-curve miniature circuit breaker (MCB) from the Basic M BMS series, rated at 400 V AC with a breaking capacity of 3 kA per IEC 60898-1. Designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panels, the BMS313B40 delivers consistent performance in a compact 52.5 × 88 × 69 mm DIN-rail-mount housing.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0405\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.8 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779045087\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB Certificate acc. to IEC 60898:\u003c\/strong\u003e International CB scheme certification for global market acceptance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European standard for insulation coordination\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC) No 1907\/2006\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229178138907,"sku":"2CDS633031R0405","price":11.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0405-bms313b40-miniature-circuit-breaker_e6b96d60-6387-405b-8189-e7aa73feee82.webp?v=1777162518"},{"product_id":"abb-2cds631031r0254-bms311c25-1p-25a-mcb","title":"ABB 2CDS631031R0254 BMS311C25 1P 25A 3kA C-Curve Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311C25 (SKU: 2CDS631031R0254) is a 1-pole 25A C-curve miniature circuit breaker from the Basic M BMS series, designed to provide reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panel applications. Rated at 230 V AC per IEC 60898-1 and 440 V per IEC 60947-2, the BMS311C25 delivers a breaking capacity of 3 kA at 230\/400 V AC and dissipates just 3.2 W per pole for efficient thermal management.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311C25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0254\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043441\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General circuit breaker protection standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear general requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Compliant with US Toxic Substances Control Act\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical panel protection\u003c\/li\u003e\n\u003cli\u003eLight industrial control panel circuit protection\u003c\/li\u003e\n\u003cli\u003eFinal circuit protection for lighting and socket outlet circuits\u003c\/li\u003e\n\u003cli\u003eDIN rail mounted installations requiring compact 17.5 mm wide 1-pole MCB\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229178302747,"sku":"2CDS631031R0254","price":2.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0254-bms311c25-miniature-circuit-breaker_11c7a33c-55bc-4495-8827-e843a2382f0d.webp?v=1777162327"},{"product_id":"abb-2cds631031r0404-bms311c40-1p-40a-mcb","title":"ABB 2CDS631031R0404 BMS311C40 1P 40A 3kA C-Curve 230V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311C40 miniature circuit breaker (MCB), catalog number BMS311C40 and SKU 2CDS631031R0404, is a 1-pole 40A C-curve device rated at 230V AC (IEC 60898-1) and 440V AC (IEC 60947-2), offering a 3kA breaking capacity for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panel applications. Part of the ABB Basic M BMS series, this compact MCB measures just 17.5mm wide and delivers dependable circuit protection with low power dissipation of 4.8W.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311C40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043601\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear — circuit breakers for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage supply system equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General requirements for circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear standard family\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substance safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eLight commercial electrical installations and sub-distribution panels\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels requiring compact 1-pole MCB protection\u003c\/li\u003e\n\u003cli\u003eBranch circuit protection in automation and electrical cabinets\u003c\/li\u003e\n\u003cli\u003eOEM machinery panel boards requiring IEC 60947-2 rated devices\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229178368283,"sku":"2CDS631031R0404","price":2.73,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0404-bms311c40-miniature-circuit-breaker_cd90273a-8922-4d69-bb22-ab23f9a971b3.webp?v=1777162351"},{"product_id":"abb-2cds631031r0164-bms311c16-1p-16a-mcb","title":"ABB 2CDS631031R0164 BMS311C16 1P 16A 3kA Curve-C Basic M BMS Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311C16 miniature circuit breaker (MCB), SKU 2CDS631031R0164, is a 1-pole, 16A, Curve-C device from the Basic M BMS series, delivering 3 kA breaking capacity at 230V AC per IEC 60898-1. Compact at just 17.5 mm wide, it is engineered for overcurrent and short-circuit protection in residential, commercial, and light industrial distribution boards. The BMS311C16 combines reliable trip performance with low power dissipation of 2.5 W, making it an efficient choice for space-constrained control panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311C16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043281\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European standard for insulation coordination\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical safety regulation — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Toxic Substances Control Act — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive — compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229178532123,"sku":"2CDS631031R0164","price":2.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0164-bms311c16-miniature-circuit-breaker_e342cf02-f799-4b83-ab43-da1bea833900.webp?v=1777162303"},{"product_id":"abb-2cds631031r0324-bms311c32-32a-1p-mcb","title":"ABB 2CDS631031R0324 BMS311C32 1P 32A 3kA C-Curve DIN Rail Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311C32 miniature circuit breaker (SKU: 2CDS631031R0324) is a 1-pole, 32 A, C-curve MCB from the Basic M BMS series, designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panels. Rated at 230 V AC per IEC 60898-1 and 440 V AC per IEC 60947-2, the BMS311C32 delivers a breaking capacity of 3 kA and mounts easily on standard DIN rail for quick installation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311C32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043526\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear — circuit breakers for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonized insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear general standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU Regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical installations and consumer units\u003c\/li\u003e\n\u003cli\u003eLight industrial control panels and automation enclosures\u003c\/li\u003e\n\u003cli\u003eProtection of branch circuits in DIN rail-mounted assemblies\u003c\/li\u003e\n\u003cli\u003eMachine control panels requiring compact 1-pole MCB protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229178597659,"sku":"2CDS631031R0324","price":2.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0324-bms311c32-miniature-circuit-breaker_f07d8843-67a8-43f4-a453-9fd38e735ff0.webp?v=1777162339"},{"product_id":"abb-2cds631031r0104-bms311c10-1p-10a-mcb","title":"ABB 2CDS631031R0104 BMS311C10 1P 10A 3kA Curve C DIN Rail Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311C10 miniature circuit breaker (MCB), catalog number BMS311C10 (SKU: 2CDS631031R0104), is a 1-pole, 10A, Curve C device from the Basic M BMS series rated at 230 V AC per IEC 60898-1 and 440 V per IEC 60947-2, delivering a breaking capacity of 3 kA at 230\/400 V AC. Designed for DIN rail mounting, the BMS311C10 provides reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panel applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311C10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General circuit breaker standard series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear — circuit breakers (industrial application)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment in low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 on chemical safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229178728731,"sku":"2CDS631031R0104","price":2.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0104-bms311c10-miniature-circuit-breaker_e9982b56-5280-44f8-97ea-eba9595acc69.webp?v=1777162291"},{"product_id":"abb-2cds631031r0204-bms311c20-1p-20a-mcb","title":"ABB 2CDS631031R0204 BMS311C20 1P 20A 3kA C-Curve Basic M BMS Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311C20 (SKU: 2CDS631031R0204) is a 1-pole 20 A C-curve miniature circuit breaker from the Basic M BMS series, designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panel applications. Rated at 230 V AC per IEC 60898-1 and 440 V per IEC 60947-2, it delivers a breaking capacity of 3 kA at 230\/400 V AC, making the BMS311C20 a dependable choice for branch circuit protection across a wide range of installations. With a compact 17.5 mm width and a weight of just 93 g, this ABB miniature circuit breaker fits efficiently on standard DIN rail assemblies.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311C20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0204\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043366\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar installations — circuit breakers for overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers for industrial use\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard for low-voltage equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European adoption of IEC 60664 insulation coordination requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General circuit breaker performance and safety standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear general requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Toxic Substances Control Act — US chemical safety compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant with EU recycling requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eBranch circuit protection in residential distribution boards and consumer units\u003c\/li\u003e\n  \u003cli\u003eCommercial building electrical panels and switchboards\u003c\/li\u003e\n  \u003cli\u003eLight industrial control panels requiring compact, single-pole protection\u003c\/li\u003e\n  \u003cli\u003eMachine tool and automation cabinet wiring where DIN rail mounting is required\u003c\/li\u003e\n  \u003cli\u003eProtection of motors, lighting circuits, and resistive loads with C-curve characteristic\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229178794267,"sku":"2CDS631031R0204","price":2.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0204-bms311c20-miniature-circuit-breaker_c39b12a3-8717-4465-852c-ba092ae7c330.webp?v=1777162315"},{"product_id":"abb-2cds632031r0164-bms312c16-2p-16a-mcb","title":"ABB 2CDS632031R0164 BMS312C16 2P 16A 3kA C-Curve 400V AC DIN Rail Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS312C16 miniature circuit breaker (SKU: 2CDS632031R0164) is a 2-pole, 16 A, C-curve MCB from the Basic M BMS series, rated at 400 V AC with a breaking capacity of 3 kA per IEC 60898-1. Designed for DIN rail installation in residential and light commercial distribution boards, the BMS312C16 delivers reliable overcurrent and short-circuit protection in a compact 35 mm × 88 mm × 69 mm footprint weighing just 186 g.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS312C16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS632031R0164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB Certificate (IEC 60898):\u003c\/strong\u003e IECEE CB Scheme certification for global market acceptance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant for EU market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU REACH regulation compliance — no substances of very high concern\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eLight commercial and small industrial control panels\u003c\/li\u003e\n\u003cli\u003eBranch circuit protection up to 16 A on 400 V AC networks\u003c\/li\u003e\n\u003cli\u003eDIN rail assemblies requiring a compact 2-pole MCB footprint\u003c\/li\u003e\n\u003cli\u003eRetrofit or new-build installations requiring IEC 60898-1 \/ IEC 60947-2 compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229180039451,"sku":"2CDS632031R0164","price":7.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds632031r0164-bms312c16-miniature-circuit-breaker_78cc8205-0253-4700-8955-22898736cf6c.webp?v=1777162398"},{"product_id":"abb-2cds632031r0204-bms312c20-2p-20a-mcb","title":"ABB 2CDS632031R0204 BMS312C20 2P 20A 3kA 400V AC Miniature Circuit Breaker MCB","description":"\u003cp\u003eThe ABB BMS312C20 miniature circuit breaker (MCB), reference \u003cstrong\u003e2CDS632031R0204\u003c\/strong\u003e, is a 2-pole, 20A device from the ABB Basic M BMS Series designed to provide reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panel applications. Rated at 400V AC per IEC 60898-1 with a breaking capacity of 3 kA, the BMS312C20 offers dependable protection in a compact 35mm × 88mm × 69mm DIN rail-mount form factor weighing just 186 g.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS312C20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS632031R0204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General requirements for miniature circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental protection requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU Regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Compliant with the US Toxic Substances Control Act\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant — supports responsible recycling\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential and commercial distribution boards\u003c\/li\u003e\n\u003cli\u003eControl panel wiring protection in light industrial automation systems\u003c\/li\u003e\n\u003cli\u003eBranch circuit protection for machinery and electrical sub-panels\u003c\/li\u003e\n\u003cli\u003eDIN rail installation in compact enclosures where space efficiency is required\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229180104987,"sku":"2CDS632031R0204","price":7.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds632031r0204-bms312c20-circuit-breaker-mcb_998b8e96-3fb7-4584-9365-153714b2d327.webp?v=1777162404"},{"product_id":"abb-2cds632031r0104-bms312c10-2p-10a-mcb","title":"ABB 2CDS632031R0104 BMS312C10 2P 10A 3kA C-Curve 400V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS312C10 (SKU: 2CDS632031R0104) is a 2-pole 10 A miniature circuit breaker from the Basic M BMS series, rated at 400 V AC with a breaking capacity of 3 kA per IEC 60898-1. Designed for compact installation in residential and light commercial distribution boards, the BMS312C10 delivers reliable overcurrent and short-circuit protection with a C-curve tripping characteristic suited to resistive and moderate inductive loads. Each pole dissipates just 2.1 W, making it an efficient choice for energy-conscious panel designs.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS312C10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS632031R0104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTripping Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043922\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e International standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Industrial low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Low-voltage insulation coordination standard family\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European adoption of IEC 60664 insulation coordination requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit breakers for overcurrent protection — general series standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general standard family\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Compliant with US Toxic Substances Control Act requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant — supports responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eLight commercial and small industrial panel assemblies\u003c\/li\u003e\n\u003cli\u003eFinal circuit protection in control panels and automation cabinets\u003c\/li\u003e\n\u003cli\u003eBranch circuit protection where compact 2-pole, 35 mm width DIN rail mounting is required\u003c\/li\u003e\n\u003cli\u003eOEM equipment where low power dissipation (2.1 W\/pole) and IEC 60898-1 compliance are mandatory\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229180170523,"sku":"2CDS632031R0104","price":7.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds632031r0104-bms312c10-miniature-circuit-breaker_f9b99dca-d7f0-4969-947d-1c3562280b6c.webp?v=1777162392"},{"product_id":"abb-2cds632031r0504-bms312c50-2p-50a-mcb","title":"ABB 2CDS632031R0504 BMS312C50 2P 50A 3kA C-Curve 400V AC DIN Rail Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS312C50 miniature circuit breaker (MCB), catalog number BMS312C50 (SKU 2CDS632031R0504), is a 2-pole, 50 A, C-curve device from the Basic M BMS series rated at 400 V AC with a breaking capacity of 3 kA. Designed for DIN rail installation in residential and light commercial distribution boards, it delivers reliable overcurrent and short-circuit protection in compact control panel applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS312C50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS632031R0504\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear — circuit breakers for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Low-voltage system insulation coordination\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Overcurrent protection circuit breaker standard family\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear standard family\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS (EU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863):\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229181514011,"sku":"2CDS632031R0504","price":11.01,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds632031r0504-bms312c50-miniature-circuit-breaker_09b55110-31a9-4327-bb21-41cc0fc4f5ab.webp?v=1777162429"},{"product_id":"abb-2cds632031r0254-bms312c25-2p-25a-mcb","title":"ABB 2CDS632031R0254 BMS312C25 2P 25A 3kA C-Curve 400V AC DIN Rail Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS312C25 miniature circuit breaker (SKU: 2CDS632031R0254) is a 2-pole, 25A, C-curve MCB from the Basic M BMS series, rated at 400V AC with a breaking capacity of 3kA, designed for reliable overcurrent and short-circuit protection in residential and light commercial distribution boards. Engineered to IEC 60898-1 and IEC 60947-2 standards, the BMS312C25 mounts on standard DIN rail and delivers consistent, dependable protection in compact control panel installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS312C25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS632031R0254\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC (IEC 60898-1) \/ 440 V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044165\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e International standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard series for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General circuit breaker product standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear general rules compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB Certificate (IEC 60898):\u003c\/strong\u003e IECEE CB scheme certification for international market acceptance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eLight commercial and industrial control panel protection\u003c\/li\u003e\n\u003cli\u003eFinal circuit protection in building electrical installations\u003c\/li\u003e\n\u003cli\u003eDIN rail mounted switchboard applications up to 400V AC\u003c\/li\u003e\n\u003cli\u003eReplacement or upgrade of legacy 2-pole MCBs in existing installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229181579547,"sku":"2CDS632031R0254","price":7.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds632031r0254-bms312c25-miniature-circuit-breaker_691789e9-a367-4eba-b8cd-1331a230eed0.webp?v=1777162410"},{"product_id":"abb-2cds631031r0504-bms311c50-1p-50a-mcb","title":"ABB 2CDS631031R0504 BMS311C50 1P 50A 3kA Curve-C Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311C50 miniature circuit breaker (MCB), SKU 2CDS631031R0504, is a 1-pole, 50 A, Curve-C device from the Basic M BMS series, rated at 230 V AC per IEC 60898-1 and 440 V AC per IEC 60947-2, with a breaking capacity of 3 kA. Designed for reliable overload and short-circuit protection in residential, commercial, and light industrial control panels, the BMS311C50 offers compact 17.5 mm DIN rail mounting and straightforward installation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311C50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0504\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043687\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar installations — circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS (EU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863):\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e EU Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOverload and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical panels and final circuits\u003c\/li\u003e\n\u003cli\u003eLight industrial control panels and machinery protection\u003c\/li\u003e\n\u003cli\u003eProtection of single-phase loads, lighting circuits, and socket outlet circuits\u003c\/li\u003e\n\u003cli\u003eDIN rail assembly in compact enclosures where 17.5 mm width is essential\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229181645083,"sku":"2CDS631031R0504","price":3.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0504-bms311c50-miniature-circuit-breaker_4c9150dc-d339-4694-9b07-afc1d8bdff0d.webp?v=1777162362"},{"product_id":"abb-2cds631031r0634-bms311c63-1p-63a-3ka-mcb","title":"ABB 2CDS631031R0634 BMS311C63 1P 63A 3kA Curve-C Miniature Circuit Breaker MCB Basic M BMS","description":"\u003cp\u003eThe ABB BMS311C63 miniature circuit breaker (MCB), SKU 2CDS631031R0634, is a 1-pole 63 A Curve-C device from the Basic M BMS series, rated for 230 V AC per IEC 60898-1 and 440 V per IEC 60947-2, delivering a breaking capacity of 3 kA. Designed for reliable overcurrent and short-circuit protection in residential, commercial, and light-industrial control panel installations, the BMS311C63 offers a compact 17.5 mm wide footprint that makes efficient use of DIN rail space.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311C63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0634\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS (EU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863):\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e EU Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e U.S. Toxic Substances Control Act compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical panels and sub-distribution boards\u003c\/li\u003e\n\u003cli\u003eLight-industrial control panels and machinery protection\u003c\/li\u003e\n\u003cli\u003eSingle-phase branch circuit protection at 230 V AC\u003c\/li\u003e\n\u003cli\u003eIndustrial automation cabinets requiring compact 17.5 mm-wide DIN rail MCBs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229182890267,"sku":"2CDS631031R0634","price":3.57,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0634-bms311c63-basic-m-bms_0fc7af20-adca-477e-a472-35033cc546d5.webp?v=1777162374"},{"product_id":"abb-2cds632031r0064-bms312c06-2p-6a-mcb","title":"ABB 2CDS632031R0064 BMS312C06 2P 6A 3kA C-Curve 400V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS312C06 miniature circuit breaker (MCB), catalog number \u003cstrong\u003eBMS312C06\u003c\/strong\u003e (SKU: 2CDS632031R0064), is a compact 2-pole, 6 A, C-curve device from the Basic M BMS series, rated at 400 V AC per IEC 60898-1 and 440 V AC per IEC 60947-2. Delivering a breaking capacity of 3 kA at 400 V AC, it provides reliable overcurrent and short-circuit protection for residential, commercial, and light industrial distribution boards and control panels.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS312C06\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS632031R0064\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043847\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear — circuit breakers for industrial applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with EU machinery and low-voltage directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Directive 2011\/65\/EU and Amendment 2015\/863 — restriction of hazardous substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection in residential and commercial distribution boards\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and machine automation cabinets\u003c\/li\u003e\n  \u003cli\u003eLight commercial HVAC and building services circuits\u003c\/li\u003e\n  \u003cli\u003eProtection of branch circuits in low-voltage switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting in compact enclosures where 35 mm width per 2 poles is required\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229182988571,"sku":"2CDS632031R0064","price":8.81,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds632031r0064-bms312c06-miniature-circuit-breaker_dfe95909-bdbc-4d0d-99d1-07ab911b09e9.webp?v=1777162386"}],"url":"https:\/\/stoklink.com\/collections\/miniature-circuit-breaker.oembed?page=30","provider":"Stoklink","version":"1.0","type":"link"}