{"title":"Network Cables, Connectors \u0026 Accessories","description":"\u003cp\u003eIndustrial network cables, connectors and accessories from Siemens, Schneider Electric and Harting. The range has over 240 products: Ethernet and PROFIBUS cables, fiber optic cables, M12 and RJ45 connectors, SFP modules, antennas and CANopen cables. Stoklink ships worldwide from Turkey and quotes project volumes on request.\u003c\/p\u003e\n\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSIMATIC NET IE TP cords and FastConnect cables for PROFINET.\u003c\/li\u003e\n\u003cli\u003ePROFIBUS FC standard cables and connectors.\u003c\/li\u003e\n\u003cli\u003eFiber optic cables with LC and SC plugs, and SCALANCE X SFP transceivers.\u003c\/li\u003e\n\u003cli\u003eHarting RJ45 and M12 Ethernet patch cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow to choose\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eProtocol: PROFINET and PROFIBUS use different cable types and colors.\u003c\/li\u003e\n\u003cli\u003eCategory: Cat5e for 100 Mbit\/s, Cat6A for Gigabit and 10G.\u003c\/li\u003e\n\u003cli\u003eConnector: RJ45 in cabinets, M12 where vibration and IP67 apply.\u003c\/li\u003e\n\u003cli\u003eFiber type: single-mode or multimode, and the plug style.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eCan I use a normal Cat6 cable for PROFINET?\u003c\/h3\u003e\n\u003cp\u003eOnly in office-like conditions. Industrial cables use shielding and jackets suited to the plant, and PROFINET specifies cable requirements.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between single-mode and multimode fiber?\u003c\/h3\u003e\n\u003cp\u003eSingle-mode carries signals over longer distances. Multimode is used for shorter runs. Both ends must use the same fiber type and transceiver.\u003c\/p\u003e\n\u003ch3\u003eCan you supply cables to length?\u003c\/h3\u003e\n\u003cp\u003eStoklink ships worldwide from Turkey under EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.\u003c\/p\u003e","products":[{"product_id":"siemens-6gk1901-0db50-6aa0-ie-fc-m12-plug-pro-4x2","title":"Siemens 6GK1901-0DB50-6AA0 IE FC M12 Plug PRO 4X2 X-Coded 8-Pin Gigabit Industrial Network Connector","description":"\u003cp\u003eThe Siemens \u003cstrong\u003e6GK1901-0DB50-6AA0\u003c\/strong\u003e IE FC M12 Plug PRO 4X2 is an 8-pin, X-coded M12 field-wireable connector for SCALANCE W and SCALANCE X gigabit interfaces. Its FastConnect insulation-displacement termination supports transfer rates up to 10 Gbit\/s over Cat6A-structured cabling. A metal enclosure with IP65\/67 protection and a –40 °C to +85 °C operating range make it suited to harsh industrial and railway environments.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrder Number (MLFB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK1901-0DB50-6AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169857345\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE X \/ SIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIE FC M12 Plug PRO 4X2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Coding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGender\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMale (plug)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Pins\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate — Industrial Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 \/ 100 \/ 1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate — 10 Gigabit Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabling Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastConnect (IDC) Termination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes — integrated insulation-displacement contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections for FC TP Cables\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 (AWG24 \/ AWG26, 0.21–0.33 mm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection to Network Component\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 × M12 plug (X-coded, male)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Outlet Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180° (axial)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectable Cable Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 … 8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking Mechanism\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed joint\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Tightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65 \/ IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE+ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSilicon-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStrain Relief\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (integrated)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–40 … +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–50 … +100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransport Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e–50 … +100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Water\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePL\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85366990\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePack Quantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eRoHS\u003c\/li\u003e\n  \u003cli\u003eUL\u003c\/li\u003e\n  \u003cli\u003ecULus\u003c\/li\u003e\n  \u003cli\u003eEN 50155\u003c\/li\u003e\n  \u003cli\u003eEN 45545-5\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSelection Notes\u003c\/h2\u003e\n\u003cp\u003eThe X-coding on this connector distinguishes it from D-coded M12 variants (which top out at Fast Ethernet) and A-coded variants (100 Mbit\/s industrial sensor I\/O): only X-coded contacts carry the pin geometry required for Cat6A 10GBASE-T. Choosing the 6GK1901-0DB50-6AA0 over the standard IE FC M12 Plug PRO 2×2 (D-coded) is mandatory wherever SCALANCE W access points or switches expose a gigabit or 10-gigabit M12 port. The axial (180°) cable outlet suits panel penetrations and cabinet gland plates where inline routing is needed; installations requiring a 90° exit should use the right-angle variant instead. PoE+ pass-through (up to 30 W per IEEE 802.3at) is supported at the mated interface, so no separate power connector is needed for PoE-powered devices.\u003c\/p\u003e\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThis connector targets SCALANCE W IWLAN access points with M12 gigabit ports installed in rolling stock, trackside cabinets, and outdoor machine enclosures where IP67 ingress protection is a panel-level requirement. The –40 °C lower operating limit and EN 50155 \/ EN 45545-5 approvals satisfy rolling-stock procurement specifications without additional derating. Silicon-free construction meets cleanliness requirements in automotive paint-shop and semiconductor environments.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959374962971,"sku":"6GK1901-0DB50-6AA0","price":53.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk1901-0db50-6aa0-ie-fc-m12-plug-pro-4x2-connector.png?v=1789641240"},{"product_id":"siemens-6gk1901-0db50-6aa8-ie-fc-m12-plug-pro-4x2","title":"Siemens 6GK1901-0DB50-6AA8 SIMATIC NET IE FC M12 Plug PRO 4x2 IP65\/67 X-Coded Connector","description":"\u003cp\u003eThe Siemens 6GK1901-0DB50-6AA8 is a SIMATIC NET IE FC M12 Plug PRO 4x2 connector that terminates 8-wire TP FastConnect installation cable into an M12 X-coded plug for SCALANCE W and SCALANCE X devices. The screwed metal enclosure is rated IP65\/67, supports PoE+ and Cat6A structured cabling, and carries data at 10\/100\/1000 Mbit\/s Industrial Ethernet or 10000 Mbit\/s over the X-coded interface.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog No\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK1901-0DB50-6AA8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK1901-0DB50-6AA8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIE FC M12 Plug PRO 4X2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFC M12 plug-in connector in high degree of protection, 8-pin, X-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor connecting electrical cables to SCALANCE W (M12 gigabit interface) for fast assembly with the FastConnect system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate (Industrial Ethernet)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, 100, 1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate (Industrial Ethernet, 10G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Connections (FC TP cables)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Connections (terminal equipment)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type (FC TP cables)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated insulation-displacement contacts for 8-wire TP FC installation cables AWG24\/AWG26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type (terminal equipment)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12 plug (X-coded, male)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastConnect Compatible\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking Mechanism\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed joint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM12 Connector Coding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Outlet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectable Cable Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 ... 8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectable Conductor Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.21 ... 0.33 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-50 ... +100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransport Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-50 ... +100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWater Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\/67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE+ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSilicon-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStrain Relief\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStructured Cabling Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169857352\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEN 50155\u003c\/li\u003e\n\u003cli\u003eEN 45545-5\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959376371995,"sku":"6GK1901-0DB50-6AA8","price":389.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk1901-0db50-6aa8-ie-fc-m12-plug-pro-4x2.png?v=1789800036"},{"product_id":"siemens-6gk1901-1ph00-iwlan-rcoax-n-connect-stripping-tool","title":"Siemens 6GK1901-1PH00 SIMATIC NET IWLAN RCoax N-Connect Stripping Tool Networking Accessory","description":"\u003cp\u003eThe Siemens 6GK1901-1PH00 is an IWLAN RCoax N-Connect stripping tool for SIMATIC NET installations, used to strip RCoax leaky feeder cable in the field before fitting N-Connect connectors. It measures 122 x 124 x 26 mm and weighs 0.22 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK1901-1PH00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169851169\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIWLAN RCoax N-Connect Stripping Tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e122 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e124 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eField preparation of IWLAN RCoax leaky feeder cable before fitting N-Connect connectors, for SIMATIC NET industrial WLAN antenna cable installations.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959376830747,"sku":"6GK1901-1PH00","price":277.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk1901-1ph00-iwlan-rcoax-n-connect-stripping-tool.png?v=1789714838"},{"product_id":"siemens-6gk1906-0eb00-m12-power-connector-l-coded","title":"Siemens 6GK1906-0EB00 SIMATIC NET Power M12 Cable Connector PRO L-Coded IP67\/69K Industrial Network Connector","description":"\u003cp\u003eThe Siemens 6GK1906-0EB00 is a Power M12 Cable Connector PRO, an L-coded, field-wireable 4-pole connector rated 12 A at 70 degC for 24 V DC power supply cabling. Its metal housing is rated IP67\/69K, accepts a 7-9 mm cable diameter and 1.5-2.5 mm squared conductors, and a 0.6 N.m screwed coupling locks the M12 thread with a 180-degree cable outlet.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6GK1906-0EB00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003ePower M12 Cable Connector PRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Description\u003c\/td\u003e\n\u003ctd\u003eM12 plug-in connector with socket insert, rated current 12 A (70 degC), 4-pole, L-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for Use\u003c\/td\u003e\n\u003ctd\u003eFor 24 V DC power supply of devices with L-coded M12 interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Connections\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eM12 connector (female contact insert, 4-pole, L-coded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmpacity of Contacts, Maximum\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmpacity up to 70 degC, Maximum\u003c\/td\u003e\n\u003ctd\u003e12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocking Mechanism\u003c\/td\u003e\n\u003ctd\u003eScrewed joint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Tightening Torque\u003c\/td\u003e\n\u003ctd\u003e0.6 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM12 Connector Coding\u003c\/td\u003e\n\u003ctd\u003eL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Cable Outlet\u003c\/td\u003e\n\u003ctd\u003e180 degree cable outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e23 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e23 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e66.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e96 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectable Cable Diameter\u003c\/td\u003e\n\u003ctd\u003e7 ... 9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectable Conductor Cross-Section\u003c\/td\u003e\n\u003ctd\u003e1.5 ... 2.5 mm squared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 ... +105 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 ... +105 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 ... +105 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Water\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP67\/69K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilicon-Free\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrain Relief\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe L-coding on this M12 connector is keyed for 24 V DC power circuits, so it cannot be mismated with a data-carrying B- or D-coded M12 port on the same panel. Its 12 A rating at 70 degC covers most 24 V DC field-device loads without derating, and the 16 A contact maximum leaves headroom versus the continuous 12 A figure. The 180-degree cable outlet and 7-9 mm cable diameter range suit a straight cable run into a junction box rather than a tight 90-degree bend.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959379222811,"sku":"6GK1906-0EB00","price":48.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk1906-0eb00-power-m12-connector-l-coded.png?v=1789800096"},{"product_id":"siemens-6gk5798-0ap00-4ca0-n-connect-10db-attenuator","title":"Siemens 6GK5798-0AP00-4CA0 SCALANCE W N-Connect 10 dB Attenuator Networking Accessory","description":"\u003cp\u003eThe Siemens 6GK5798-0AP00-4CA0 is an N-Connect male\/female inline attenuator that reduces signal level by 10 dB across 0-6 GHz, for SCALANCE W IWLAN antenna runs. It carries an IP67 rating, works from -40 to +100 degrees C, and mounts between an antenna and cable or radio with a 4-6 N.m tightening torque.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5798-0AP00-4CA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIWLAN attenuator N-Connect male\/female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169851176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN-Connect male \/ N-Connect female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-6 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReturn loss, minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsertion loss, maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-6 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +100 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +100 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +100 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e53 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eRoHS\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eUse this 10 dB pad when an antenna's gain would otherwise overdrive a SCALANCE W radio's receiver input at short range, such as a short indoor hop with a high-gain panel antenna. The 23 dB minimum return loss keeps reflections low even with the added attenuation, and IP67 lets it sit outdoors in the antenna line rather than only indoors.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959395213595,"sku":"6GK5798-0AP00-4CA0","price":82.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5798-0ap00-4ca0-n-connect-attenuator.png?v=1789825575"},{"product_id":"siemens-6gk5798-0cp00-1aa0-n-connect-coupler","title":"Siemens 6GK5798-0CP00-1AA0 SCALANCE W N-Connect Male\/Male Coupler IP68 Networking Accessory","description":"\u003cp\u003eThe Siemens 6GK5798-0CP00-1AA0 is an N-Connect male\/male coupling piece that joins two male-terminated IWLAN cables or pigtails end to end, extending a run or bridging a break in a SCALANCE W antenna feed without going back through a female bulkhead adapter. It covers 0-6 GHz at 50 ohm impedance, carries an IP68 rating, and operates from -40 to +70 degrees C.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5798-0CP00-1AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIWLAN coupler N-Connect male\/male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4018359299316\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN-Connect male \/ N-Connect male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-6 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReturn loss, minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eRoHS\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBoth ends of this coupler are N-Connect male, so it is the piece to use when extending or joining two male-terminated antenna cables rather than mating a cable to an antenna or radio, which are normally female. The IP68 rating is a step above the IP67 attenuator and IP65 lightning protector in the same accessory range, useful for a splice that stays submerged or buried rather than just wet.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959396917531,"sku":"6GK5798-0CP00-1AA0","price":15.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5798-0cp00-1aa0-n-connect-coupler.png?v=1789825588"},{"product_id":"siemens-6gk5798-0sn00-0ea0-power-splitter","title":"Siemens 6GK5798-0SN00-0EA0 SCALANCE W N-Connect Female 2-Fold Power Splitter Networking Accessory","description":"\u003cp\u003eThe Siemens 6GK5798-0SN00-0EA0 is a 2-fold N-Connect female power splitter, a Y-element that divides a 2.4\/5 GHz IWLAN signal between two antenna or cable branches for SCALANCE W installations. It is rated IP66\/68, with IP68 verified at 0.5 bar for 1 hour, and operates from -40 to +110 degrees C.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5798-0SN00-0EA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIWLAN power splitter N-Connect female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169851206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN-Connect female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4-6.425 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReturn loss, minimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsertion loss, maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.15 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +110 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +110 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +110 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalt-laden atmosphere resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, severity 3, EN 60068-2-52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP66\/68, IP68 at 0.5 bar for 1 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e71.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e131.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e937 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eRoHS\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eSplitting the signal three ways (one input, two outputs) means each output loses roughly half the input power on top of the 3.15 dB maximum insertion loss, so the antenna gain on each branch needs to cover that budget before this is a net gain over a single antenna. The severity-3 salt-mist rating is the highest in the SCALANCE W accessory range, and IP68 verified at 0.5 bar makes it the choice for a permanently wet or coastal outdoor mount rather than the lower-rated attenuator or coupler pieces.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959398424859,"sku":"6GK5798-0SN00-0EA0","price":336.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5798-0sn00-0ea0-power-splitter.png?v=1789825595"},{"product_id":"siemens-6gk5798-2lp10-2aa6-lp798-2n-lightning-protector","title":"Siemens 6GK5798-2LP10-2AA6 SCALANCE W LP798-2N Lightning Protector 2-6 GHz Networking Accessory","description":"\u003cp\u003eThe Siemens 6GK5798-2LP10-2AA6 LP798-2N is a lightning protection element with N-Connect female\/female connections, using quarter-wave technology to shunt surge energy on SCALANCE W antenna lines from 2 to 6 GHz. It adds no more than 0.2 dB of insertion loss, carries an IP68 rating, and operates from -40 to +85 degrees C indoors or outdoors.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5798-2LP10-2AA6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLightning protector LP798-2N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169854443\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN-Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlug-in connection design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFemale \/ female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000-6000 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsertion loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 dB max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable for interior use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable for outside use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSilicone-free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is a quarter-wave protector, so it grounds surge energy by resonant design rather than a gas-discharge tube, which keeps the 0.2 dB insertion loss low enough to fit inline on the same antenna feed without a noticeable link-budget hit. IP68 and the -40 to +85 degrees C range let it sit outdoors at the antenna end of the run, where lightning protection is most needed, instead of only at an indoor equipment rack.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959399014683,"sku":"6GK5798-2LP10-2AA6","price":266.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5798-2lp10-2aa6-lp798-2n-lightning-protector.png?v=1789825601"},{"product_id":"siemens-6gk5798-8mb00-0ac1-rcoax-cable-clip","title":"Siemens 6GK5798-8MB00-0AC1 SCALANCE W IWLAN RCoax Cable Clip 1\/2-Inch 10-Pack Networking Accessory","description":"\u003cp\u003eThe Siemens 6GK5798-8MB00-0AC1 is an IWLAN RCoax Cable-Clip 1\/2-Zoll, a cable clip that holds RCoax leaky-feeder cable along a wall or cable tray. It ships as a pack of 10 clips, each rated -40 to +110 degrees C for operation, storage, and transport, and weighs 40 g; fixing screws are not included in the scope of supply.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6GK5798-8MB00-0AC1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eIWLAN RCoax Cable-Clip 1\/2-Zoll\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Size\u003c\/td\u003e\n\u003ctd\u003e1\/2 inch RCoax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Quantity\u003c\/td\u003e\n\u003ctd\u003e10 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e26.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e40 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation, Storage, Transport)\u003c\/td\u003e\n\u003ctd\u003e-40 ... +110 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eCH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169851244\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959399702811,"sku":"6GK5798-8MB00-0AC1","price":16.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5798-8mb00-0ac1-rcoax-cable-clip.png?v=1789825620"},{"product_id":"siemens-6gk5798-8mb00-0am1-rcoax-cable-clip-100","title":"Siemens 6GK5798-8MB00-0AM1 SCALANCE W IWLAN RCoax Cable Clip 1\/2-Inch 100-Pack Networking Accessory","description":"\u003cp\u003eThe Siemens 6GK5798-8MB00-0AM1 is an IWLAN RCoax Cable-Clip 1\/2-Zoll, a cable clip that holds RCoax leaky-feeder cable along a wall or cable tray, supplied as a bulk pack of 100. Each clip is rated -40 to +110 degrees C for operation, storage, and transport, and the pack weighs 0.48 kg; fixing screws are not included in the scope of supply.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6GK5798-8MB00-0AM1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eIWLAN RCoax Cable-Clip 1\/2-Zoll\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Size\u003c\/td\u003e\n\u003ctd\u003e1\/2 inch RCoax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Quantity\u003c\/td\u003e\n\u003ctd\u003e100 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e26.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e36 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (Pack)\u003c\/td\u003e\n\u003ctd\u003e0.48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation, Storage, Transport)\u003c\/td\u003e\n\u003ctd\u003e-40 ... +110 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eCH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169851251\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959399866651,"sku":"6GK5798-8MB00-0AM1","price":136.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5798-8mb00-0am1-rcoax-cable-clip-100.png?v=1789825627"},{"product_id":"siemens-6gk5798-8md00-0ac1-rcoax-spacer-85mm","title":"Siemens 6GK5798-8MD00-0AC1 SCALANCE W IWLAN RCoax Spacer 85mm 10-Pack Networking Accessory","description":"\u003cp\u003eThe Siemens 6GK5798-8MD00-0AC1 is an IWLAN RCoax Spacer 85mm, used with the 1\/2-inch RCoax cable clip to hold RCoax leaky-feeder cable 85 mm off the mounting surface. It ships as a pack of 10 spacers, each 50 mm wide and 30 mm high, with a total pack weight of 0.28 kg; fixing screws are not included in the scope of supply.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6GK5798-8MD00-0AC1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eIWLAN RCoax Spacer 85mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpacer Distance\u003c\/td\u003e\n\u003ctd\u003e85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed With\u003c\/td\u003e\n\u003ctd\u003e1\/2-inch RCoax cable clip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Quantity\u003c\/td\u003e\n\u003ctd\u003e10 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (Pack)\u003c\/td\u003e\n\u003ctd\u003e0.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eCH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169851282\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959401013531,"sku":"6GK5798-8MD00-0AC1","price":61.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5798-8md00-0ac1-rcoax-spacer-85mm.png?v=1789825633"},{"product_id":"siemens-6gk5798-8md00-0am1-rcoax-spacer-85mm-100","title":"Siemens 6GK5798-8MD00-0AM1 SCALANCE W IWLAN RCoax Spacer 85mm 100-Pack Networking Accessory","description":"\u003cp\u003eThe Siemens 6GK5798-8MD00-0AM1 is an IWLAN RCoax Spacer 85mm, used with the 1\/2-inch RCoax cable clip to hold RCoax leaky-feeder cable 85 mm off the mounting surface, supplied as a bulk pack of 100. Each spacer is 50 mm wide and 30 mm high, with a total pack weight of 0.29 kg; fixing screws are not included in the scope of supply.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6GK5798-8MD00-0AM1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eIWLAN RCoax Spacer 85mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpacer Distance\u003c\/td\u003e\n\u003ctd\u003e85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed With\u003c\/td\u003e\n\u003ctd\u003e1\/2-inch RCoax cable clip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Quantity\u003c\/td\u003e\n\u003ctd\u003e100 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (Pack)\u003c\/td\u003e\n\u003ctd\u003e0.29 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eCH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169851299\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959401308443,"sku":"6GK5798-8MD00-0AM1","price":549.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5798-8md00-0am1-rcoax-spacer-85mm-100.png?v=1789825639"},{"product_id":"siemens-6gk5795-1tn00-1aa0-ti795-1n-terminating-resistor","title":"Siemens 6GK5795-1TN00-1AA0 SCALANCE W TI795-1N N-Connect 50 Ohm IP65 Networking Accessory","description":"\u003cp\u003eThe Siemens 6GK5795-1TN00-1AA0 (TI795-1N) is a SCALANCE W N-Connect male terminating resistor with 50 Ω impedance and a minimum 25 dB return loss across 0-6 GHz. Rated IP65 and -40 to +70°C, it caps an unused N-Connect port on a SCALANCE W access point or antenna cable to keep the RF system matched.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5795-1TN00-1AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4018359299323\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIWLAN Terminating Resistor TI795-1N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN-Connect, male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 6 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReturn Loss (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (Operation\/Storage\/Transport)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.045 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eRoHS\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eTerminating an unused N-Connect port on a SCALANCE W antenna splitter or access point with the TI795-1N holds the line at 50 Ω, keeping the minimum 25 dB return loss the WLAN radio expects instead of leaving the port open to reflect signal back into the transmitter. Its IP65 rating lets it sit outdoors alongside the antennas and cabling it terminates.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959450034459,"sku":"6GK5795-1TN00-1AA0","price":24.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5795-1tn00-1aa0-ti795-1n-terminating-resistor.png?v=1789825519"},{"product_id":"siemens-6gk5795-1tr10-0aa6-ti795-1r-terminating-resistor","title":"Siemens 6GK5795-1TR10-0AA6 SCALANCE W TI795-1R R-SMA 50 Ohm IP65 Networking Accessory","description":"\u003cp\u003eThe Siemens 6GK5795-1TR10-0AA6 (TI795-1R) is a SCALANCE W R-SMA male terminating resistor with 50 Ω impedance and a minimum 25 dB return loss across 0-6 GHz, sold as a pack of three. Its gold-plated brass connector, IP65 rating and -40 to +70°C range let it cap an unused R-SMA antenna port on a SCALANCE W access point outdoors.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5795-1TR10-0AA6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169852852\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIWLAN Terminating Resistor TI795-1R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-SMA, male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 6 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReturn Loss (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrass, gold-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (Operation\/Storage\/Transport)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.005 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackaging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 pack = 3 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eRoHS\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe R-SMA male connector on the TI795-1R matches the smaller antenna ports used on SCALANCE W clients and some access point variants, where the TI795-1N's N-Connect thread would not fit. Sold three to a pack, it covers a multi-port radio or a small stock of spares for R-SMA ports left open after an antenna is removed or relocated.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959450591515,"sku":"6GK5795-1TR10-0AA6","price":27.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5795-1tr10-0aa6-ti795-1r-terminating-resistor.png?v=1789825526"},{"product_id":"siemens-6gk5798-0cn00-0aa0-rcoax-n-connector","title":"Siemens 6GK5798-0CN00-0AA0 SCALANCE W RCoax N-Connect Female 2.4\/5 GHz Network Connector","description":"\u003cp\u003eThe Siemens 6GK5798-0CN00-0AA0 is a field-assembled RCoax N-Connect female connector for joining lengths of RCoax leaky-feeder cable and connecting further components in a 2.4 and 5 GHz IWLAN radiating-cable run, where the leaky cable itself acts as a distributed antenna along a tunnel or corridor. It covers 0-6 GHz at 50 ohm impedance, is rated IP67, and operates from -40 to +85 degrees C.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5798-0CN00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIWLAN RCoax connector N-Connect female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4018359303075\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN-Connect female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-6 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e159 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eRoHS\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis connector is field-assembled onto the cut end of an RCoax radiating cable, which is how a tunnel or mine leaky-feeder run is extended or spliced on site rather than ordered as one continuous factory length. The 0-6 GHz range and 50 ohm impedance match it to the RCoax cable itself and to SCALANCE W IWLAN radios operating in the 2.4 and 5 GHz bands, and the IP67 rating lets the joint sit in the same enclosed, damp environment as the cable run.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959452360987,"sku":"6GK5798-0CN00-0AA0","price":59.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5798-0cn00-0aa0-rcoax-n-connector.png?v=1789825582"},{"product_id":"siemens-6gk5798-8ma00-0aa1-din-rail-adapter","title":"Siemens 6GK5798-8MA00-0AA1 SCALANCE W Angled DIN Rail Mounting Adapter Networking Accessory","description":"\u003cp\u003eThe Siemens 6GK5798-8MA00-0AA1 is a 90-degree elbow adapter for DIN-rail mounting of SCALANCE W778, W778EEC, W738, WAM766, and WUM766 wireless access points, plus a 35 mm DIN-rail mounting adapter bracket. It weighs 0.3 kg and the package includes fixing screws, letting an installer angle the access point off a standard rail instead of building a custom wall bracket in the cabinet.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6GK5798-8MA00-0AA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eAngled adapter for DIN rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible With\u003c\/td\u003e\n\u003ctd\u003eSCALANCE W778, W778EEC, W738, WAM766, WUM766\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eBracket, fixing screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169856546\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959453016347,"sku":"6GK5798-8MA00-0AA1","price":41.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5798-8ma00-0aa1-din-rail-adapter.png?v=1789825614"},{"product_id":"siemens-6gk5798-8mf00-0aa1-din-rail-mounting-set","title":"Siemens 6GK5798-8MF00-0AA1 SCALANCE W778\/W738 DIN Rail Mounting Set Networking Accessory","description":"\u003cp\u003eThe Siemens 6GK5798-8MF00-0AA1 is a DIN-rail mounting adapter for SCALANCE W778, W778EEC, W738, WAM766-1, WAM766-1EEC, WUM766-1, and MUM856-1 wireless devices, and doubles as a 90-degree DIN-rail mount for the SCALANCE WAM763-1, WUM763-1, and MUM853-1 family. It weighs 0.3 kg, and the package includes the adapter body plus the fixing screws needed to complete the installation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6GK5798-8MF00-0AA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eMounting set SCALANCE W778\/W778EEC\/W738\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible With (DIN Rail Mount)\u003c\/td\u003e\n\u003ctd\u003eSCALANCE W778, W778EEC, W738, WAM766-1, WAM766-1EEC, WUM766-1, MUM856-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible With (90-Degree DIN Rail Mount)\u003c\/td\u003e\n\u003ctd\u003eSCALANCE WAM763-1, WUM763-1, MUM853-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Contents\u003c\/td\u003e\n\u003ctd\u003eAdapter, fixing screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622488683\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959453770011,"sku":"6GK5798-8MF00-0AA1","price":55.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5798-8mf00-0aa1-din-rail-mounting-set.png?v=1789825645"},{"product_id":"siemens-6gk5907-4pa00-key-plug-w740-ifeatures","title":"Siemens 6GK5907-4PA00 SCALANCE W KEY-PLUG W740 iFeatures Client Mode Networking Accessory","description":"\u003cp\u003eThe Siemens 6GK5907-4PA00 KEY-PLUG W740 is a removable data storage medium that activates iPCF, iPCF MC and iPRP client-mode iFeatures on SCALANCE W780\/W770 and W740\/W730 access points operating as clients. It also stores configuration and application data, so replacing a faulty device is a plug swap rather than a reconfiguration, and it holds 256 MiB of storage in a 24.3 x 17 x 8.1 mm module.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5907-4PA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169240741\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKEY-PLUG W740\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnables\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eiPCF client mode, iPCF MC client mode, iPRP client mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE W780\/W770 (client mode), SCALANCE W740\/W730\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256 MiB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Storage Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKEY-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +75 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransport Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity (max, at 25 degC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGlobal Warming Potential (total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1264 kg CO2 eq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEPD\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eChoose the W740 KEY-PLUG specifically for client-side iFeatures; it targets SCALANCE W devices operating in client mode (iPCF client, iPCF MC client, iPRP client) rather than access-point mode, so it is the module to stock for the moving or subordinate end of a wireless link, not the infrastructure side. The -40 to +75 degC operating rating covers unheated cabinets and vehicle-mounted enclosures, so the module can stay plugged in rather than being pulled out between configuration sessions.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959454294299,"sku":"6GK5907-4PA00","price":283.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5907-4pa00-key-plug-w740.png?v=1789825681"},{"product_id":"siemens-6gk5907-8pa00-key-plug-w780-ifeatures","title":"Siemens 6GK5907-8PA00 SCALANCE W KEY-PLUG W780 iFeatures Access Point Networking Accessory","description":"\u003cp\u003eThe Siemens 6GK5907-8PA00 KEY-PLUG W780 is a removable data storage medium that activates iPCF, iPCF MC, iREF and iPRP iFeatures on SCALANCE W780\/W770 and W740\/W730 devices in both access point and client mode. It also stores configuration and application data, so a faulty unit is replaced with a plug swap, and it holds 256 MiB of storage in a 24.3 x 17 x 8.1 mm module.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5907-8PA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169240758\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKEY-PLUG W780\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnables\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eiPCF, iPCF MC, iREF, iPRP iFeatures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE W780\/W770, SCALANCE W740\/W730 (access point and client mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256 MiB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Storage Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKEY-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentification Link Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, acc. to IEC 61406-1:2022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +75 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransport Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity (max, at 25 degC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGlobal Warming Potential (total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1264 kg CO2 eq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eEPD\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the W780 KEY-PLUG over the W740 variant when the device needs to run in access point mode: it unlocks iREF alongside iPCF, iPCF MC and iPRP, covering both infrastructure and client roles on the same SCALANCE W780\/W770 or W740\/W730 hardware. IEC 61406-1:2022 identification-link support lets the module report its own ID electronically for asset tracking, which the client-only W740 KEY-PLUG does not list.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959455179035,"sku":"6GK5907-8PA00","price":566.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5907-8pa00-key-plug-w780.png?v=1789825688"},{"product_id":"siemens-6gk5991-1ad00-8aa0-sfp991-1","title":"Siemens 6GK5991-1AD00-8AA0 SCALANCE X SFP991-1 100 Mbps LC SFP Transceiver Module","description":"\u003cp\u003eThe Siemens 6GK5991-1AD00-8AA0 is an SFP991-1 plug-in transceiver for SCALANCE X switches, providing one 100 Mbit\/s LC port over multimode glass fiber up to 5 km (with OM2++ fiber) using 100BASE-FX at 1300 nm. It is rated for hazardous-location use (ATEX Zone 2, FM Class 1 Division 2) and an operating range of -40 to +85 °C.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5991-1AD00-8AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFP991-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePorts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x 100 Mbit\/s LC port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100BASE-FX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1300 nm, multimode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 - 5 km, depending on fiber used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 °C (max. 16 h at +85 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 x 9 x 57 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLatched, SFP slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e490 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169207591\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eC-Tick\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eSFP991-1 identifies the 100 Mbit\/s LC single-port variant; select it for SCALANCE X switch slots needing a 100BASE-FX fiber uplink specifically, since a Gigabit application needs a different SFP model with a higher rated transmission method. The 1300 nm wavelength and 5 km multimode range fit inter-building or long production-line fiber runs where copper Ethernet distance limits (100 m) do not reach. Hazardous-location approval (ATEX, FM) makes it usable in SCALANCE X switches installed in Zone 2 \/ Division 2 areas without a separate barrier.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSCALANCE X switch uplinks over multimode fiber between buildings or distant production areas, and installations in classified hazardous zones where the switch itself carries the matching approval.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959455310107,"sku":"6GK5991-1AD00-8AA0","price":148.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5991-1ad00-8aa0-sfp991-1.png?v=1789679532"},{"product_id":"siemens-6gk5991-1ad00-8ac0-sfp991-1-transceiver","title":"Siemens 6GK5991-1AD00-8AC0 SCALANCE X SFP991-1 100Mbps LC Multimode 5km SFP Transceiver 10-Pack","description":"\u003cp\u003eThe Siemens 6GK5991-1AD00-8AC0 SFP991-1 is a 100 Mbps SFP transceiver for SCALANCE X switches, sold as a 10-piece pack, with a single LC port running 100BASE-FX over multimode fiber up to 5 km. It operates at 1300 nm with a -40 to +85 degC rating and IP20 housing, and carries ATEX\/FM hazardous-location certification for Zone 2\/Division 2 installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5991-1AD00-8AC0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047622798782\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFP991-1 (10-Pack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePack Quantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e100 Mbit\/s LC Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1300 nm, multi-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100BASE-FX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 - 5 km (fiber-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 to -14 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReceiver Input Power (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-12 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReceiver Sensitivity (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-31 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Link Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC (up to 16h at +85 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage\/Transport Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity (max, at 25 degC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFP module, latched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e57 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight (per unit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e490 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eC-Tick\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eChoose the SFP991-1 when the link runs on multimode fiber up to 5 km and 100 Mbps is enough bandwidth; its -24 to -14 dBm transmit power and -31 dBm receiver sensitivity are set for shorter multimode runs, not the longer-reach single-mode SFP variants in the same family. The 10-piece pack size fits stocking multiple SCALANCE X switch ports or spares from one order rather than buying single units.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959457079579,"sku":"6GK5991-1AD00-8AC0","price":1298.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5991-1ad00-8ac0-sfp991-1.png?v=1789825700"},{"product_id":"siemens-6gk5991-1ad00-8ga0-sfp991-1a-transceiver","title":"Siemens 6GK5991-1AD00-8GA0 SCALANCE X SFP991-1A 100Mbps LC Multimode 5km SFP Transceiver","description":"\u003cp\u003eThe Siemens 6GK5991-1AD00-8GA0 SFP991-1A is an active 100 Mbps SFP transceiver for SCALANCE X switches, with a single LC port running 100BASE-FX over multimode fiber up to 5 km at 1310 nm. It is rated -40 to +95 degC operating temperature and carries hazardous-location approval including CCC-Ex for Chinese installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5991-1AD00-8GA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047622859629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFP991-1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e100 Mbit\/s LC Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1310 nm, multi-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100BASE-FX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 - 5 km (fiber-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-23.5 to -14 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReceiver Input Power (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-8 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReceiver Sensitivity (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-31 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Link Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +95 degC (up to 16h at +95 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage\/Transport Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +95 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity (max, at 25 degC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFP module, latched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e57 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e345 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGlobal Warming Potential (total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32.31 kg CO2 eq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eC-Tick\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe SFP991-1A's -40 to +95 degC operating range and CCC-Ex hazardous-location mark fit installation sites that run hotter than a typical cabinet or fall under Chinese classified-zone requirements, where a general-purpose 100 Mbps multimode SFP's approvals and temperature spec would not apply. Its optical budget (100BASE-FX, 5 km multimode) is otherwise a standard 100 Mbps link, so the reason to specify this part is the ambient rating and the certification, not extra reach.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959457505563,"sku":"6GK5991-1AD00-8GA0","price":295.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5991-1ad00-8ga0-sfp991-1a.png?v=1789826007"},{"product_id":"siemens-6gk5991-1ae00-8aa0-sfp991-1lh-transceiver","title":"Siemens 6GK5991-1AE00-8AA0 SCALANCE X SFP991-1LH+ 100Mbps LC Single-Mode 70km SFP Transceiver","description":"\u003cp\u003eThe Siemens 6GK5991-1AE00-8AA0 SFP991-1LH+ is a 100 Mbps SFP transceiver for SCALANCE X switches, with a single LC port running 100BASE-LX over single-mode fiber for 12 to 70 km reach at 1550 nm. It carries FM and ATEX hazardous-location approval, CCC Ex marking for China, and French marine classification society (BV) certification for shipboard installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5991-1AE00-8AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169208000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFP991-1LH+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e100 Mbit\/s LC Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1550 nm, single-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100BASE-LX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 - 70 km (fiber-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 to 0 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReceiver Input Power (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReceiver Sensitivity (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-34 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Link Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentification Link Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, acc. to IEC 61406-1:2022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC (up to 16h at +85 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage\/Transport Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity (max, at 25 degC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFP module, latched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e57 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGlobal Warming Potential (total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.09 kg CO2 eq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eC-Tick\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eSpecify the SFP991-1LH+ when a link has to cross 12 to 70 km of single-mode fiber, well beyond the multimode SFPs in the same family; its -5 to 0 dBm transmit power and -34 dBm receiver sensitivity give it the optical budget for that distance, with a minimum 3 dB attenuation requirement to avoid receiver saturation on short single-mode runs. Marine classification and CCC-Ex approval make it the choice for shipboard or Chinese classified-zone links, not just long distance.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959459045659,"sku":"6GK5991-1AE00-8AA0","price":448.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5991-1ae00-8aa0-sfp991-1lh.png?v=1789826014"},{"product_id":"siemens-6gk5991-1ae30-8aa0-sfp991-1elh200","title":"Siemens 6GK5991-1AE30-8AA0 SCALANCE X SFP991-1ELH200 100Mbps LC Single-Mode 200km SFP Transceiver","description":"\u003cp\u003eThe Siemens 6GK5991-1AE30-8AA0 SFP991-1ELH200 is a 100 Mbps SFP transceiver for SCALANCE X switches, with a single LC port running 100BASE-LX over single-mode fiber for 61 to 200 km reach at 1550 nm. Its 1 to 5 dBm transmit power and -42 dBm receiver sensitivity give it the longest optical budget in the SFP991 family, and it carries FM and ATEX hazardous-location approval plus CCC Ex marking for China.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5991-1AE30-8AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169256902\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFP991-1ELH200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e100 Mbit\/s LC Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1550 nm, single-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100BASE-LX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61 - 200 km (fiber-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 5 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReceiver Input Power (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-9 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReceiver Sensitivity (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-42 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Link Attenuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIdentification Link Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, acc. to IEC 61406-1:2022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC (up to 16h at +85 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage\/Transport Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity (max, at 25 degC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFP module, latched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e57 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGlobal Warming Potential (total)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.95 kg CO2 eq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eC-Tick\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eSpecify the SFP991-1ELH200 only when the run genuinely needs 61 to 200 km of single-mode fiber; the 14 dB minimum attenuation requirement means it will saturate its own receiver on shorter links where a lower-power single-mode variant would work instead. Its 1 to 5 dBm transmitter output is the highest in the family, which is what buys the extended reach at the cost of needing more fiber loss between the two ends to stay in the receiver's working range.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959459471643,"sku":"6GK5991-1AE30-8AA0","price":985.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5991-1ae30-8aa0-sfp991-1elh200.png?v=1789826020"},{"product_id":"siemens-6gk5991-1af00-8aa0-sfp991-1ld-sfp-transceiver","title":"Siemens 6GK5991-1AF00-8AA0 SCALANCE X SFP991-1LD 100 Mbit\/s Single-Mode 26 km SFP Transceiver Module","description":"\u003cp\u003eThe Siemens SFP991-1LD (6GK5991-1AF00-8AA0) is a single-mode SFP transceiver module for SCALANCE X Industrial Ethernet switches, providing one 100 Mbit\/s optical LC port with a transmission range up to 26 km via the 100BASE-LX method. It runs across a -40 to +85 °C ambient range, matching SCALANCE X switches rated for outdoor cabinets or unconditioned enclosures.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5991-1AF00-8AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFP991-1LD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC, single-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1310 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100BASE-LX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of 100 Mbit\/s LC Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...26 km, depending on fiber used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (Operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLatched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e490 a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eC-Tick\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the single-mode 100 Mbit\/s variant in the SCALANCE X SFP portfolio: pick it over a multi-mode 100 Mbit\/s SFP once the run exceeds roughly 2 km, since the 1310 nm single-mode path is rated to 26 km. The -40...+85 °C window lets it sit in the same enclosure as SCALANCE X switches specified for unheated or outdoor cabinets without a separate temperature derating check.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eExtends optical uplinks between SCALANCE X switches in ring or line topologies once copper's roughly 100 m reach is exceeded - linking switch cabinets between buildings, along long conveyor or process lines, or across plant sections on a single-mode fiber backbone.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959461142811,"sku":"6GK5991-1AF00-8AA0","price":218.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5991-1af00-8aa0-sfp991-1ld-sfp-transceiver.png?v=1789681262"},{"product_id":"siemens-6gk5991-1af00-8ac0-sfp991-1ld-transceiver","title":"Siemens 6GK5991-1AF00-8AC0 SCALANCE X SFP991-1LD 100Mbit\/s 26km Single-Mode SFP Transceiver Module","description":"\u003cp\u003eThe Siemens 6GK5991-1AF00-8AC0 is a SCALANCE X SFP991-1LD plug-in transceiver with a single 100 Mbit\/s single-mode LC optical port, supporting fiber runs up to 26 km using 100BASE-LX transmission at 1310 nm. It is IP20-rated for -40 to +85 degrees C operation, sold in packs of 10 units, and intended as a field-installable optic for SCALANCE X switch fiber ports.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5991-1AF00-8AC0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSFP991-1LD (pack of 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Optical Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLC, single-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1310 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100BASE-LX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 26 km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Output Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15 to -8 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReceiver Sensitivity, Min.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-28 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 x 9 x 57 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 kg per unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLatched, SFP slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e490 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePack Quantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eC-Tick\u003c\/li\u003e\n\u003cli\u003eBureau Veritas\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 1310 nm single-mode optics and -8 to -15 dB transmitter output give this SFP a 26 km maximum range at 100 Mbit\/s over single-mode fiber - a multi-mode SFP variant is the better choice for shorter runs where fiber cost matters more than distance. Since it ships as a pack of 10, plan spares or replacements at that unit count rather than ordering single pieces. The -40 to +85 degrees C operating range, with +85 degrees C limited to 16-hour duration, covers outdoor or unheated-cabinet installations that a standard commercial-temperature SFP would not.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eLong-distance fiber uplinks between SCALANCE X switches over single-mode fiber, connecting distributed Industrial Ethernet segments across a plant or site where copper or multi-mode fiber distance limits are exceeded.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959461306651,"sku":"6GK5991-1AF00-8AC0","price":1923.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5991-1af00-8ac0-scalance-x-sfp991-1ld.png?v=1789679089"},{"product_id":"siemens-6gk5991-1af00-8ga0-sfp991-1ld-a-transceiver","title":"Siemens 6GK5991-1AF00-8GA0 SCALANCE X SFP991-1LD A 100 Mbit\/s LC Single-Mode 26 km SFP Transceiver Module","description":"\u003cp\u003eThe Siemens 6GK5991-1AF00-8GA0 (SFP991-1LD A) is an active plug-in SFP transceiver for the SCALANCE X media module slot, adding one 100 Mbit\/s optical LC port. It runs single-mode fiber and covers a range of up to 26 km at 1310 nm on the 100BASE-LX link. Operating temperature extends to -40...+95 degrees C, and IP20 latched mounting keeps installation straightforward inside the switch housing.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6GK5991-1AF00-8GA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eSFP991-1LD A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622859636\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Interfaces\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 Mbit\/s LC Ports\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Interface Design\u003c\/td\u003e\n\u003ctd\u003eLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e1310 nm, single-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Output Power\u003c\/td\u003e\n\u003ctd\u003e-15 to -8 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Input Power (Max)\u003c\/td\u003e\n\u003ctd\u003e-8 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Sensitivity (Min)\u003c\/td\u003e\n\u003ctd\u003e-31 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Link Attenuation\u003c\/td\u003e\n\u003ctd\u003e0 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Range\u003c\/td\u003e\n\u003ctd\u003e0-26 km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Method\u003c\/td\u003e\n\u003ctd\u003e100BASE-LX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation)\u003c\/td\u003e\n\u003ctd\u003e-40 to +95 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Storage)\u003c\/td\u003e\n\u003ctd\u003e-40 to +95 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Transport)\u003c\/td\u003e\n\u003ctd\u003e-40 to +95 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Note\u003c\/td\u003e\n\u003ctd\u003e+95 deg C max permissible for up to 16 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (Max, 25 deg C)\u003c\/td\u003e\n\u003ctd\u003e95 percent, no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003eSFP Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e14 x 9 x 57 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (Module)\u003c\/td\u003e\n\u003ctd\u003e0.01 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (Packaged)\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFastening Method\u003c\/td\u003e\n\u003ctd\u003eLatched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eTaiwan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e370 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Zone Standard\u003c\/td\u003e\n\u003ctd\u003eEN 60079-0:2006, EN 60079-15:2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standard (CSA\/UL)\u003c\/td\u003e\n\u003ctd\u003eUL 62368-1, CAN\/CSA C22.2 No. 62368-1:19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmitted Interference Standard\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4:2007 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference Immunity Standard\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-2:2005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (Total)\u003c\/td\u003e\n\u003ctd\u003e32.31 kg CO2 eq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (Manufacturing)\u003c\/td\u003e\n\u003ctd\u003e2.2 kg CO2 eq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (Operation)\u003c\/td\u003e\n\u003ctd\u003e30.1 kg CO2 eq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (End of Life)\u003c\/td\u003e\n\u003ctd\u003e0.01 kg CO2 eq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eC-Tick\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe A suffix on the SFP991-1LD A marks Siemens' extended-temperature build: -40 to +95 degrees C operation, with a 16-hour rating at the top end, versus the -40 to +85 degrees C spec on the standard SCALANCE X media modules, making it the choice for switches in unheated cabinets or direct sun exposure. Its single-mode link reaches up to 26 km, far beyond the 5 km limit of the multimode ST\/BFOC media module in this series, so it is the transceiver to specify whenever the fiber run between two SCALANCE X switches exceeds multimode distance limits. Pick a standard-temperature single-mode SFP instead when the installation stays inside a climate-controlled cabinet, since the optical budget is the same at a lower net weight.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959461437723,"sku":"6GK5991-1AF00-8GA0","price":330.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5991-1af00-8ga0-sfp991-1ld-a-sfp-transceiver.png?v=1789825706"},{"product_id":"siemens-6gk5992-1al00-8ac0-sfp992-1-sfp-transceiver-module","title":"Siemens 6GK5992-1AL00-8AC0 SCALANCE X SFP992-1 1000BASE-SX Multimode LC SFP Transceiver Module 10-Pack","description":"\u003cp\u003eThe Siemens 6GK5992-1AL00-8AC0 SFP992-1 is a plug-in SFP transceiver for SCALANCE X switches, providing one 1000 Mbit\/s multimode LC port with an 850 nm optical wavelength and a fiber range of 0.35 to 0.75 km. It uses the 1000BASE-SX transmission method and is supplied as a 10-piece pack for stocking spare or expansion transceivers across multiple switch ports.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6GK5992-1AL00-8AC0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eSFP992-1 (x10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical interfaces\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort type\u003c\/td\u003e\n\u003ctd\u003e1x 1000 Mbit\/s LC, multimode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission method\u003c\/td\u003e\n\u003ctd\u003e1000BASE-SX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e850 nm, multimode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter output power\u003c\/td\u003e\n\u003ctd\u003e-9.5 to -2.5 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver input power (max)\u003c\/td\u003e\n\u003ctd\u003e-3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver sensitivity (min)\u003c\/td\u003e\n\u003ctd\u003e-17 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber range\u003c\/td\u003e\n\u003ctd\u003e0.35-0.75 km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-40...+85 degrees C (max 85 degrees C for up to 16 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-40...+85 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity (max)\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003eSFP module, latched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e14 x 9 x 57 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.02 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e670 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eC-Tick\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 850 nm multimode LC port and 0.35-0.75 km range fit fiber runs between SCALANCE X switches on the same site rather than long-haul single-mode links; for longer distances a single-mode SFP variant is needed instead. The latched SFP form factor allows hot-swapping into a live switch port without powering down the rest of the ring. Ordering the 10-piece pack covers a multi-switch fiber ring or leaves spares on hand for field replacement, since SFP modules are the most common point of optical-link failure.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eFiber uplinks between SCALANCE X industrial Ethernet switches, redundant ring topologies, and extending Ethernet segments beyond copper's 100 m distance limit within a plant or building.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959461601563,"sku":"6GK5992-1AL00-8AC0","price":2301.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5992-1al00-8ac0-sfp992-1-sfp-transceiver-module.png?v=1789714870"},{"product_id":"siemens-6gk5992-1am00-8ac0-sfp992-1ld-transceiver-10-pack","title":"Siemens 6GK5992-1AM00-8AC0 SCALANCE X SFP992-1LD 1000 Mbit\/s LC Single-Mode 10 km 10-Pack SFP Transceiver Module","description":"\u003cp\u003eThe Siemens 6GK5992-1AM00-8AC0 is a 10-piece pack of SFP992-1LD plug-in transceivers for the SCALANCE X media module slot, each adding one 1000 Mbit\/s optical LC port. Every transceiver runs single-mode fiber on the 1000BASE-LX link and covers a range of up to 10 km at 1310 nm. Operating temperature extends to -40...+85 degrees C, with a 16-hour rating up to +85 degrees C.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6GK5992-1AM00-8AC0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eSFP992-1LD (x10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePack Quantity\u003c\/td\u003e\n\u003ctd\u003e10 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622798867\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Interfaces (per unit)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 Mbit\/s LC Ports (per unit)\u003c\/td\u003e\n\u003ctd\u003e1, single-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Interface Design\u003c\/td\u003e\n\u003ctd\u003eLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e1310 nm, single-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Output Power\u003c\/td\u003e\n\u003ctd\u003e-9.5 to -3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Input Power (Max)\u003c\/td\u003e\n\u003ctd\u003e-3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Sensitivity (Min)\u003c\/td\u003e\n\u003ctd\u003e-19 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Link Attenuation\u003c\/td\u003e\n\u003ctd\u003e0 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Range\u003c\/td\u003e\n\u003ctd\u003e0-10 km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Method\u003c\/td\u003e\n\u003ctd\u003e1000BASE-LX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation)\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Storage)\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Transport)\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Note\u003c\/td\u003e\n\u003ctd\u003e+85 deg C max permissible for up to 16 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (Max, 25 deg C)\u003c\/td\u003e\n\u003ctd\u003e95 percent, no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003eSFP Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D, per unit)\u003c\/td\u003e\n\u003ctd\u003e14 x 9 x 57 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (Module, per unit)\u003c\/td\u003e\n\u003ctd\u003e0.02 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (Pack)\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFastening Method\u003c\/td\u003e\n\u003ctd\u003eLatched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eMalaysia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e600 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFM Standard\u003c\/td\u003e\n\u003ctd\u003eFM3611: Class 1 Division 2 Group A,B,C,D T4; Class 1 Zone 2 Group IIC T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Zone Standard\u003c\/td\u003e\n\u003ctd\u003eEN 60079-0:2006, EN 60079-15:2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standard (CSA\/UL)\u003c\/td\u003e\n\u003ctd\u003eUL 62368-1, CAN\/CSA C22.2 No. 62368-1:19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmitted Interference Standard\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4:2007 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference Immunity Standard\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-2:2005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eC-Tick\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBuying the SFP992-1LD as this 10-piece pack cuts per-unit handling for projects that need to populate multiple SCALANCE X switches at once, since it ships and is ordered as a single line item instead of ten. Its 1000BASE-LX single-mode link reaches 10 km, the shortest-range option in the SFP992 single-mode family, so it is the right pick when switch cabinets sit within a plant or a single building and a longer-reach, higher-cost transceiver is not needed. For a single spare unit rather than a bulk fit-out, or for links beyond 10 km, a longer-range single-mode SFP is the better fit.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959461765403,"sku":"6GK5992-1AM00-8AC0","price":3339.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5992-1am00-8ac0-sfp992-1ld-transceiver-10-pack.png?v=1789825725"},{"product_id":"siemens-6gk5992-1am30-8aa0-sfp992-1ld-plus-transceiver","title":"Siemens 6GK5992-1AM30-8AA0 SCALANCE X SFP992-1LD+ 1000 Mbit\/s LC Single-Mode 30 km SFP Transceiver Module","description":"\u003cp\u003eThe Siemens 6GK5992-1AM30-8AA0 (SFP992-1LD+) is a plug-in SFP transceiver for the SCALANCE X media module slot, adding one 1000 Mbit\/s optical LC port. It runs single-mode fiber on the 1000BASE-LX link and covers a range of up to 30 km at 1310 nm. Operating temperature is -40 to +85 degrees C, and IP20 latched mounting keeps it fixed in the switch housing.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6GK5992-1AM30-8AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eSFP992-1LD+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622798768\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Interfaces\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 Mbit\/s LC Ports\u003c\/td\u003e\n\u003ctd\u003e1, single-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Interface Design\u003c\/td\u003e\n\u003ctd\u003eLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e1310 nm, single-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Output Power\u003c\/td\u003e\n\u003ctd\u003e-5 to 0 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Input Power (Max)\u003c\/td\u003e\n\u003ctd\u003e0 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Sensitivity (Min)\u003c\/td\u003e\n\u003ctd\u003e-24 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Link Attenuation\u003c\/td\u003e\n\u003ctd\u003e0 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Range\u003c\/td\u003e\n\u003ctd\u003e0-30 km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Method\u003c\/td\u003e\n\u003ctd\u003e1000BASE-LX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation)\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Storage)\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Transport)\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (Max, 25 deg C)\u003c\/td\u003e\n\u003ctd\u003e95 percent, no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003eSFP Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e14 x 9 x 57 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (Module)\u003c\/td\u003e\n\u003ctd\u003e0.02 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (Packaged)\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFastening Method\u003c\/td\u003e\n\u003ctd\u003eLatched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eTaiwan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e320 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Zone Standard\u003c\/td\u003e\n\u003ctd\u003eEN 60079-0:2006, EN 60079-15:2005, II 3 G Ex nA II T4, KEMA 07 ATEX 0145 X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standard (CSA\/UL)\u003c\/td\u003e\n\u003ctd\u003eUL 62368-1, CAN\/CSA C22.2 No. 62368-1:19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmitted Interference Standard\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4:2007 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference Immunity Standard\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-2:2005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Zone Marking (CCC)\u003c\/td\u003e\n\u003ctd\u003eGB3836.1, GB3836.8, Ex nA IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (Total)\u003c\/td\u003e\n\u003ctd\u003e18.06 kg CO2 eq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (Manufacturing)\u003c\/td\u003e\n\u003ctd\u003e1.7 kg CO2 eq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (Operation)\u003c\/td\u003e\n\u003ctd\u003e16.35 kg CO2 eq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlobal Warming Potential (End of Life)\u003c\/td\u003e\n\u003ctd\u003e0.01 kg CO2 eq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eC-Tick\u003c\/li\u003e\n\u003cli\u003eBV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe plus suffix on the SFP992-1LD+ extends the range to 30 km, three times the 10 km reach of the base SFP992-1LD in the same 1000BASE-LX family, at the cost of a lower minimum receiver sensitivity margin (-24 dB versus -19 dB). Use it when a SCALANCE X link has to bridge a distance the base single-mode SFP cannot cover, and step down to the shorter-range unit when the run is under 10 km, since the extra optical budget is not needed there. Beyond 30 km, a long-haul variant in the same SFP992 family is required instead.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959461896475,"sku":"6GK5992-1AM30-8AA0","price":679.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5992-1am30-8aa0-sfp992-1ld-plus-transceiver.png?v=1789825731"},{"product_id":"siemens-6xv1878-5he30-ie-tp-cord-m12-180-03m","title":"Siemens 6XV1878-5HE30 SIMATIC NET IE TP Cord M12-180\/M12-180 0.3m Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5HE30 is a preassembled IE TP Cord M12-180\/M12-180, a 0.3 m Industrial Ethernet patch cord with two X-coded M12 connectors for connecting stations such as SCALANCE W or XP-200. Rated 100 Ω impedance with IP65\/IP67 protection and PoE\/PoE+\/PoE++ support, it operates from -30 to +80 °C and meets Cat6A structured-cabling performance in a flexible PUR sheath.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5HE30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169856270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/M12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Description\u003c\/td\u003e\n\u003ctd\u003eFlexible plug-in cable (8-wire), prefabricated with two IE FC M12 connectors 4x2, X-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability\u003c\/td\u003e\n\u003ctd\u003eConnecting Industrial Ethernet stations with an M12 interface, e.g. SCALANCE W and XP-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Designation\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e0.3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Connections\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 10 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 100 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 300 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 600 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance (1-100 MHz)\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk per Length at 100 MHz\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk per Length at 300 MHz\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk per Length at 600 MHz\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoupling Loss at 30-100 MHz (min)\u003c\/td\u003e\n\u003ctd\u003e80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Resistance per Length (max)\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance Coefficient\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage (RMS)\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNVP Value\u003c\/td\u003e\n\u003ctd\u003e68 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Cores\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield Design\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil with braided tinned-copper shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Diameter (AWG26)\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Diameter\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner Sheath Diameter\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Diameter\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath Diameter Tolerance\u003c\/td\u003e\n\u003ctd\u003e0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Material\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Material\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Wire Colors\u003c\/td\u003e\n\u003ctd\u003eWhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBending Radius, Single Bend (min)\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBending Radius, Multiple Bends (min)\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Load\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight per Length\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.06 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Interlock\u003c\/td\u003e\n\u003ctd\u003eScrewed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug-In Connection Design\u003c\/td\u003e\n\u003ctd\u003eM12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Coding\u003c\/td\u003e\n\u003ctd\u003eM12, X-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Behavior\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Mineral Oil\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Grease\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Water\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUV Resistance\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP65, IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHalogen-Free\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE \/ PoE+ \/ PoE++ Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilicone-Free\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/ETL Listing (300 V)\u003c\/td\u003e\n\u003ctd\u003eAWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Suitability\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStructured Cabling Standard\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the 0.3 m cord for the shortest device-to-device hop — for example, linking two adjacent SCALANCE W access points on the same panel — where its 100 Ω impedance and 0.28 dB\/m attenuation at 100 MHz add negligible loss. All three M12-180\/M12-180 lengths in this family share the identical S\/FTP shield, IP65\/IP67 rating, and PoE++ support, so move to the 0.5 m or 1 m cord only when the physical mounting distance between the two M12 ports exceeds this reach.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959474053403,"sku":"6XV1878-5HE30","price":70.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5he30-ie-tp-cord-m12-180-0-3m.png?v=1790183341"},{"product_id":"siemens-6xv1878-5he50-ie-tp-cord-m12-180-05m","title":"Siemens 6XV1878-5HE50 SIMATIC NET IE TP Cord M12-180\/M12-180 0.5m Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5HE50 preassembled IE TP Cord M12-180\/M12-180 is a 0.5 m Industrial Ethernet patch cord terminated with two X-coded M12 connectors, built for stations such as SCALANCE W or XP-200. It carries 100 Ω impedance, IP65\/IP67 sealing, and PoE\/PoE+\/PoE++ support across a -30 to +80 °C range, with Cat6A performance in a flexible PUR-jacketed S\/FTP construction.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5HE50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169856287\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/M12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Description\u003c\/td\u003e\n\u003ctd\u003eFlexible plug-in cable (8-wire), prefabricated with two IE FC M12 connectors 4x2, X-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability\u003c\/td\u003e\n\u003ctd\u003eConnecting Industrial Ethernet stations with an M12 interface, e.g. SCALANCE W and XP-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Designation\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Connections\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 10 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 100 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 300 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 600 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance (1-100 MHz)\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk per Length at 100 MHz\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk per Length at 300 MHz\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk per Length at 600 MHz\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoupling Loss at 30-100 MHz (min)\u003c\/td\u003e\n\u003ctd\u003e80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Resistance per Length (max)\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance Coefficient\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage (RMS)\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNVP Value\u003c\/td\u003e\n\u003ctd\u003e68 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Cores\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield Design\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil with braided tinned-copper shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Diameter (AWG26)\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Diameter\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner Sheath Diameter\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Diameter\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath Diameter Tolerance\u003c\/td\u003e\n\u003ctd\u003e0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Material\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Material\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Wire Colors\u003c\/td\u003e\n\u003ctd\u003eWhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBending Radius, Single Bend (min)\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBending Radius, Multiple Bends (min)\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Load\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight per Length\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.065 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Interlock\u003c\/td\u003e\n\u003ctd\u003eScrewed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug-In Connection Design\u003c\/td\u003e\n\u003ctd\u003eM12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Coding\u003c\/td\u003e\n\u003ctd\u003eM12, X-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Behavior\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Mineral Oil\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Grease\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Water\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUV Resistance\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP65, IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHalogen-Free\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE \/ PoE+ \/ PoE++ Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilicone-Free\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/ETL Listing (300 V)\u003c\/td\u003e\n\u003ctd\u003eAWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Suitability\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStructured Cabling Standard\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 0.5 m cord bridges a slightly wider gap than the 0.3 m version — a typical use is linking a SCALANCE W unit to a nearby junction box or the next DIN-rail position — while adding only marginal attenuation, since 0.28 dB\/m at 100 MHz applies equally across the family. Because connector type, shield design, and IP rating are identical across the 0.3 m, 0.5 m, and 1 m variants, base the length choice solely on the measured distance between the two M12 ports rather than on any performance difference.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959474118939,"sku":"6XV1878-5HE50","price":74.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5he50-ie-tp-cord-m12-180-0-5m.png?v=1790183347"},{"product_id":"siemens-6xv1878-5hh10-ie-tp-cord-m12-180-1m","title":"Siemens 6XV1878-5HH10 SIMATIC NET IE TP Cord M12-180\/M12-180 1m Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5HH10 is a preassembled IE TP Cord M12-180\/M12-180, a 1 m Industrial Ethernet patch cord fitted with two X-coded M12 connectors for stations such as SCALANCE W or XP-200. It delivers 100 Ω impedance, IP65\/IP67 protection, and PoE\/PoE+\/PoE++ support over a -30 to +80 °C range, in a Cat6A-rated, PUR-jacketed S\/FTP cable.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5HH10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169856294\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/M12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Description\u003c\/td\u003e\n\u003ctd\u003eFlexible plug-in cable (8-wire), prefabricated with two IE FC M12 connectors 4x2, X-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability\u003c\/td\u003e\n\u003ctd\u003eConnecting Industrial Ethernet stations with an M12 interface, e.g. SCALANCE W and XP-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Designation\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Connections\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 10 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 100 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 300 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 600 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance (1-100 MHz)\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk per Length at 100 MHz\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk per Length at 300 MHz\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk per Length at 600 MHz\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoupling Loss at 30-100 MHz (min)\u003c\/td\u003e\n\u003ctd\u003e80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Resistance per Length (max)\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance Coefficient\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage (RMS)\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNVP Value\u003c\/td\u003e\n\u003ctd\u003e68 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Cores\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield Design\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil with braided tinned-copper shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Diameter (AWG26)\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Diameter\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner Sheath Diameter\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Diameter\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath Diameter Tolerance\u003c\/td\u003e\n\u003ctd\u003e0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Material\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Material\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Wire Colors\u003c\/td\u003e\n\u003ctd\u003eWhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBending Radius, Single Bend (min)\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBending Radius, Multiple Bends (min)\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Load\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight per Length\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.101 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Interlock\u003c\/td\u003e\n\u003ctd\u003eScrewed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug-In Connection Design\u003c\/td\u003e\n\u003ctd\u003eM12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Coding\u003c\/td\u003e\n\u003ctd\u003eM12, X-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Behavior\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Mineral Oil\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Grease\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Water\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUV Resistance\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP65, IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHalogen-Free\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE \/ PoE+ \/ PoE++ Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilicone-Free\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/ETL Listing (300 V)\u003c\/td\u003e\n\u003ctd\u003eAWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Suitability\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStructured Cabling Standard\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 1 m, this is the longest reach in the M12-180\/M12-180 cord family, suited to connections that span a full cabinet depth or reach a SCALANCE W unit mounted on an adjacent structure. Attenuation still totals under 0.3 dB at 100 MHz over the full length, so signal margin is not a practical constraint; choose the shorter 0.3 m or 0.5 m cords instead when the run is shorter, to reduce cable slack inside the enclosure.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959474151707,"sku":"6XV1878-5HH10","price":81.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5hh10-ie-tp-cord-m12-180-1m.png?v=1790183353"},{"product_id":"siemens-6xv1878-5hh15-ie-tp-cord-m12-180-m12-180-1-5m","title":"Siemens 6XV1878-5HH15 SIMATIC NET IE TP Cord M12-180\/M12-180 1.5 m Cat6A Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5HH15 is a SIMATIC NET IE TP Cord M12-180\/M12-180, a pre-assembled Industrial Ethernet patch cable with M12-180 X-coded connectors screwed onto both ends of a 1.5 m run. Built as an 8-core S\/FTP Cat6A cable rated IP65\/IP67, it carries PoE, PoE+, and PoE++ between two M12-equipped stations such as SCALANCE W or XP-200 without an in-line coupler.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5HH15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169856300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/M12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Cores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard for Structured Cabling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor connecting Industrial Ethernet stations with an M12 interface (e.g. SCALANCE W and XP-200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 10 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 100 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 300 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 600 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance (1-100 MHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 100 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 300 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 600 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoupling Loss (30-100 MHz, min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Resistance per Length (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage (RMS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNVP Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e68%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of Shield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil, sheathed in a protective braided shield of tinned copper wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Diameter (AWG26 insulated conductor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Inner Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTolerance of Outer Diameter (Cable Sheath)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Data Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ewhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Single Bend (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Multiple Bends (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Load (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight per Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlug Interlock Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of Plug-in Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Coding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM12 Circular Connector Coding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire Behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Mineral Oil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Grease\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Water\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV Radiation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65, IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHalogen-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE+ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE++ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSilicon-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL\/ETL Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, 300 V rating, AWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertificate of Suitability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85444210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 1.5 m this is the shortest length in the M12-180\/M12-180 line, suited for jumpers between two adjacent M12-equipped devices inside the same cabinet or drag-chain segment. The 32.5 mm minimum single-bend radius and 100 N tensile rating keep it workable in tight ducting; for runs between more distant field stations, choose one of the longer-length variants in the same M12-180\/M12-180 line.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959474184475,"sku":"6XV1878-5HH15","price":90.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5hh15-ie-tp-cord-m12-m12-network-cable.png?v=1790183359"},{"product_id":"siemens-6xv1878-5hh20-ie-tp-cord-m12-180-m12-180-2m","title":"Siemens 6XV1878-5HH20 SIMATIC NET IE TP Cord M12-180\/M12-180 2 m Cat6A Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5HH20 is a SIMATIC NET IE TP Cord M12-180\/M12-180, a pre-assembled Industrial Ethernet patch cable with M12-180 X-coded connectors on both ends of a 2 m run. Built as an 8-core S\/FTP Cat6A cable rated IP65\/IP67, it carries PoE, PoE+, and PoE++ between two M12-equipped stations such as SCALANCE W or XP-200 without needing an in-line coupler joint.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5HH20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169856317\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/M12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Cores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard for Structured Cabling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor connecting Industrial Ethernet stations with an M12 interface (e.g. SCALANCE W and XP-200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 10 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 100 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 300 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 600 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance (1-100 MHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 100 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 300 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 600 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoupling Loss (30-100 MHz, min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Resistance per Length (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage (RMS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNVP Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e68%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of Shield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil, sheathed in a protective braided shield of tinned copper wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Diameter (AWG26 insulated conductor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Inner Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTolerance of Outer Diameter (Cable Sheath)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Data Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ewhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Single Bend (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Multiple Bends (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Load (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight per Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlug Interlock Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of Plug-in Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Coding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM12 Circular Connector Coding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire Behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Mineral Oil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Grease\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Water\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV Radiation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65, IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHalogen-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE+ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE++ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSilicon-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL\/ETL Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, 300 V rating, AWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertificate of Suitability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85444210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 2 m length covers jumpers a bit longer than adjacent-panel runs, such as connecting two M12 stations across a machine base or through a short duct. The 65 mm multiple-bend radius applies once the cable is routed around corners rather than laid straight; for tighter or much longer runs, pick a shorter or longer variant in the same M12-180\/M12-180 line.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959474217243,"sku":"6XV1878-5HH20","price":98.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5hh20-ie-tp-cord-m12-m12-network-cable.png?v=1790183365"},{"product_id":"siemens-6xv1878-5hh30-ie-tp-cord-m12-180-m12-180-3m","title":"Siemens 6XV1878-5HH30 SIMATIC NET IE TP Cord M12-180\/M12-180 3 m Cat6A Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5HH30 is a SIMATIC NET IE TP Cord M12-180\/M12-180, a pre-assembled Industrial Ethernet patch cable with M12-180 X-coded connectors on both ends of a 3 m run. Built as an 8-core S\/FTP Cat6A cable rated IP65\/IP67, it carries PoE, PoE+, and PoE++ between two M12-equipped stations such as SCALANCE W or XP-200 across a full machine section.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5HH30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169856324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/M12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Cores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard for Structured Cabling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor connecting Industrial Ethernet stations with an M12 interface (e.g. SCALANCE W and XP-200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 10 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 100 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 300 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 600 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance (1-100 MHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 100 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 300 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 600 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoupling Loss (30-100 MHz, min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Resistance per Length (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage (RMS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNVP Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e68%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of Shield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil, sheathed in a protective braided shield of tinned copper wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Diameter (AWG26 insulated conductor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Inner Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTolerance of Outer Diameter (Cable Sheath)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Data Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ewhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Single Bend (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Multiple Bends (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Load (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight per Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlug Interlock Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of Plug-in Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Coding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM12 Circular Connector Coding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire Behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Mineral Oil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Grease\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Water\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV Radiation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65, IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHalogen-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE+ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE++ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSilicon-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL\/ETL Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, 300 V rating, AWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertificate of Suitability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85444210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 3 m this length reaches across a typical machine section, for example from an M12 field switch on one axis to a sensor node on the next. Keep the routed bend above the 65 mm multiple-bend radius when it passes through a drag chain, and check the 100 N tensile rating against chain travel; shorter or longer variants in the same M12-180\/M12-180 line cover other runs.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959474250011,"sku":"6XV1878-5HH30","price":114.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5hh30-ie-tp-cord-m12-m12-network-cable.png?v=1790183372"},{"product_id":"siemens-6xv1878-5hh50-ie-tp-cord-m12-180-m12-180-5m","title":"Siemens 6XV1878-5HH50 SIMATIC NET IE TP Cord M12-180\/M12-180 5 m Cat6A Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5HH50 is a SIMATIC NET IE TP Cord M12-180\/M12-180, a pre-assembled Industrial Ethernet patch cable with M12-180 X-coded connectors on both ends of a 5 m run. Built as an 8-core S\/FTP Cat6A cable rated IP65\/IP67, it carries PoE, PoE+, and PoE++ between two M12-equipped stations such as SCALANCE W or XP-200 spanning several machine bays.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5HH50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169856331\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/M12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Cores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard for Structured Cabling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor connecting Industrial Ethernet stations with an M12 interface (e.g. SCALANCE W and XP-200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 10 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 100 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 300 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 600 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance (1-100 MHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 100 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 300 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 600 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoupling Loss (30-100 MHz, min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Resistance per Length (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage (RMS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNVP Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e68%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of Shield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil, sheathed in a protective braided shield of tinned copper wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Diameter (AWG26 insulated conductor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Inner Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTolerance of Outer Diameter (Cable Sheath)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Data Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ewhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Single Bend (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Multiple Bends (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Load (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight per Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlug Interlock Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of Plug-in Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Coding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM12 Circular Connector Coding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire Behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Mineral Oil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Grease\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Water\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV Radiation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65, IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHalogen-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE+ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE++ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSilicon-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL\/ETL Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, 300 V rating, AWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertificate of Suitability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.39 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85444210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 5 m this length spans several machine bays or a longer conveyor run without a mid-cable coupler. Route it through a drag chain within the 65 mm multiple-bend radius and stay under the 100 N tensile rating on moving axes; for shorter jumpers or runs beyond 5 m, pick another length in the same M12-180\/M12-180 line.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959474282779,"sku":"6XV1878-5HH50","price":115.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5hh50-ie-tp-cord-m12-m12-network-cable.png?v=1790183378"},{"product_id":"siemens-6xv1878-5hn10-ie-tp-cord-m12-180-m12-180-10m","title":"Siemens 6XV1878-5HN10 SIMATIC NET IE TP Cord M12-180\/M12-180 10 m Cat6A Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5HN10 is a SIMATIC NET IE TP Cord M12-180\/M12-180, a pre-assembled Industrial Ethernet patch cable with M12-180 X-coded connectors on both ends of a 10 m run. Built as an 8-core S\/FTP Cat6A cable rated IP65\/IP67, it carries PoE, PoE+, and PoE++ between two distant M12-equipped stations such as SCALANCE W or XP-200 without an in-field splice.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5HN10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169856348\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/M12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Cores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard for Structured Cabling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor connecting Industrial Ethernet stations with an M12 interface (e.g. SCALANCE W and XP-200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 10 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 100 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 300 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 600 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance (1-100 MHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 100 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 300 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 600 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoupling Loss (30-100 MHz, min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Resistance per Length (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage (RMS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNVP Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e68%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of Shield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil, sheathed in a protective braided shield of tinned copper wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Diameter (AWG26 insulated conductor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Inner Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTolerance of Outer Diameter (Cable Sheath)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Data Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ewhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Single Bend (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Multiple Bends (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Load (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight per Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlug Interlock Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of Plug-in Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Coding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM12 Circular Connector Coding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire Behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Mineral Oil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Grease\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Water\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV Radiation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65, IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHalogen-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE+ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE++ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSilicon-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL\/ETL Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, 300 V rating, AWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertificate of Suitability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.74 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85444210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 10 m this length covers runs between M12 stations placed on separate machine lines, where a fixed pre-assembled cable avoids an in-field splice or coupler joint. Keep the routed slack within the 65 mm multiple-bend radius and below the 100 N tensile load if it travels through a drag chain; shorter variants in the same M12-180\/M12-180 line suit tighter enclosure jumpers.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959474315547,"sku":"6XV1878-5HN10","price":153.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5hn10-ie-tp-cord-m12-m12-network-cable.png?v=1790183384"},{"product_id":"siemens-6xv1878-5hn15-ie-tp-cord-m12-180-m12-180-15m","title":"Siemens 6XV1878-5HN15 SIMATIC NET IE TP Cord M12-180\/M12-180 15 m Cat6A Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5HN15 is a SIMATIC NET IE TP Cord M12-180\/M12-180, a pre-assembled Industrial Ethernet patch cable with M12-180 X-coded connectors on both ends of a 15 m run. Built as an 8-core S\/FTP Cat6A cable rated IP65\/IP67, it carries PoE, PoE+, and PoE++ between two M12-equipped stations such as SCALANCE W or XP-200 across a full production line.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5HN15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169856355\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/M12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Cores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard for Structured Cabling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor connecting Industrial Ethernet stations with an M12 interface (e.g. SCALANCE W and XP-200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 10 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 100 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 300 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 600 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance (1-100 MHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 100 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 300 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 600 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoupling Loss (30-100 MHz, min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Resistance per Length (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage (RMS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNVP Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e68%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of Shield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil, sheathed in a protective braided shield of tinned copper wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Diameter (AWG26 insulated conductor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Inner Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTolerance of Outer Diameter (Cable Sheath)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Data Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ewhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Single Bend (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Multiple Bends (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Load (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight per Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlug Interlock Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of Plug-in Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Coding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM12 Circular Connector Coding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire Behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Mineral Oil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Grease\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Water\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV Radiation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65, IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHalogen-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE+ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE++ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSilicon-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL\/ETL Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, 300 V rating, AWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertificate of Suitability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85444210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 15 m this is the longest length in the M12-180\/M12-180 line, suited for runs across a full production line where a fixed-length pre-assembled cable avoids an in-field splice. Watch the 65 mm multiple-bend radius and 100 N tensile rating when routing this length through cable trays or drag chains; shorter-length variants in the same line suit tighter enclosure-to-enclosure jumpers.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959474348315,"sku":"6XV1878-5HN15","price":195.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5hn15-ie-tp-cord-m12-m12-network-cable.png?v=1790183390"},{"product_id":"siemens-6xv1878-5te50-ie-tp-cord-m12-180-rj45-180-0-5m","title":"Siemens 6XV1878-5TE50 SIMATIC NET IE TP Cord M12-180\/RJ45-180 0.5 m Cat6A Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5TE50 is a SIMATIC NET IE TP Cord M12-180\/RJ45-180, a pre-assembled Industrial Ethernet patch cable with an M12-180 X-coded connector at one end and an RJ45 connector at the other, on a 0.5 m S\/FTP Cat6A run. It carries PoE, PoE+, and PoE++, connecting an IP65\/IP67 M12 field device such as SCALANCE W or X to a standard IP20 RJ45 port.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5TE50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169857758\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/RJ45-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Cores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard for Structured Cabling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor connecting Industrial Ethernet stations with an M12 interface (e.g. SCALANCE W and SCALANCE X)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 10 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 100 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 300 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 600 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance (1-100 MHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 100 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 300 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 600 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Resistance per Length (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage (RMS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNVP Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e68%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of Shield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil, sheathed in a protective braided shield of tinned copper wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Diameter (AWG26 insulated conductor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Inner Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTolerance of Outer Diameter (Cable Sheath)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Data Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ewhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Single Bend (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Multiple Bends (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Load (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight per Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire Behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Mineral Oil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Grease\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Water\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV Radiation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\/67 (M12), IP20 (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHalogen-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE+ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE++ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSilicon-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL\/ETL Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, 300 V rating, AWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertificate of Suitability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.052 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85444210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 0.5 m this is the shortest length in the M12-180\/RJ45-180 line, sized for mounting the RJ45 end directly at a switch or PLC port in the same enclosure as the M12 field connection. Because the RJ45 end is rated IP20 rather than IP65\/IP67, terminate it inside a cabinet; longer-length variants in the same line cover runs where the switch sits farther from the M12 entry point.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959474413851,"sku":"6XV1878-5TE50","price":62.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5te50-ie-tp-cord-m12-rj45-network-cable.png?v=1790183396"},{"product_id":"siemens-6xv1878-5th10-ie-tp-cord-m12-180-rj45-180-1m","title":"Siemens 6XV1878-5TH10 SIMATIC NET IE TP Cord M12-180\/RJ45-180 1 m Cat6A Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5TH10 is a SIMATIC NET IE TP Cord M12-180\/RJ45-180, a pre-assembled Industrial Ethernet patch cable with an M12-180 X-coded connector at one end and an RJ45 connector at the other, on a 1 m S\/FTP Cat6A run. It carries PoE, PoE+, and PoE++, connecting an IP65\/IP67 M12 field device such as SCALANCE W or X to a standard IP20 RJ45 switch port.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5TH10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169857765\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/RJ45-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Cores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard for Structured Cabling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor connecting Industrial Ethernet stations with an M12 interface (e.g. SCALANCE W and SCALANCE X)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 10 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 100 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 300 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 600 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance (1-100 MHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 100 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 300 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 600 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Resistance per Length (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage (RMS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNVP Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e68%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of Shield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil, sheathed in a protective braided shield of tinned copper wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Diameter (AWG26 insulated conductor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Inner Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTolerance of Outer Diameter (Cable Sheath)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Data Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ewhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Single Bend (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Multiple Bends (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Load (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight per Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire Behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Mineral Oil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Grease\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Water\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV Radiation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\/67 (M12), IP20 (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHalogen-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE+ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE++ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSilicon-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL\/ETL Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, 300 V rating, AWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertificate of Suitability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.076 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85444210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 1 m length gives enough slack to route from a nearby cabinet-mounted switch to an M12 gland entry without pulling the cable taut. Keep the IP20 RJ45 end inside the enclosure and the IP65\/IP67 M12 end in the field; for tighter same-cabinet jumpers or longer switch-to-panel runs, pick another length in the same M12-180\/RJ45-180 line.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959474512155,"sku":"6XV1878-5TH10","price":67.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5th10-ie-tp-cord-m12-rj45-network-cable.png?v=1790183403"},{"product_id":"siemens-6xv1878-5th15-ie-tp-cord-m12-180-rj45-180-1-5m","title":"Siemens 6XV1878-5TH15 SIMATIC NET IE TP Cord M12-180\/RJ45-180 1.5 m Cat6A Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5TH15 is a SIMATIC NET IE TP Cord M12-180\/RJ45-180, a pre-assembled Industrial Ethernet patch cable with an M12-180 X-coded connector at one end and an RJ45 connector at the other, on a 1.5 m S\/FTP Cat6A run. It carries PoE, PoE+, and PoE++, connecting an IP65\/IP67 M12 field device such as SCALANCE W or X to a standard IP20 RJ45 port.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5TH15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169857772\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/RJ45-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Cores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard for Structured Cabling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor connecting Industrial Ethernet stations with an M12 interface (e.g. SCALANCE W and SCALANCE X)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 10 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 100 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 300 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 600 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance (1-100 MHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 100 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 300 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 600 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Resistance per Length (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage (RMS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNVP Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e68%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of Shield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil, sheathed in a protective braided shield of tinned copper wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Diameter (AWG26 insulated conductor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Inner Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTolerance of Outer Diameter (Cable Sheath)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Data Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ewhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Single Bend (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Multiple Bends (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Load (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight per Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire Behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Mineral Oil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Grease\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Water\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV Radiation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\/67 (M12), IP20 (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHalogen-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE+ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE++ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSilicon-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL\/ETL Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, 300 V rating, AWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertificate of Suitability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.098 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85444210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 1.5 m this length reaches from an M12 gland entry to a switch mounted farther inside the same cabinet or an adjacent panel. Keep the IP20 RJ45 end inside the enclosure and check the 32.5 mm minimum single-bend radius where the cable turns into the gland; other lengths in the same M12-180\/RJ45-180 line cover shorter or longer switch-to-panel runs.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959474643227,"sku":"6XV1878-5TH15","price":72.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5th15-ie-tp-cord-m12-rj45-network-cable.png?v=1790183409"},{"product_id":"siemens-6xv1878-5th20-ie-tp-cord-m12-180-rj45-180-2m","title":"Siemens 6XV1878-5TH20 SIMATIC NET IE TP Cord M12-180\/RJ45-180 2 m Cat6A Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5TH20 is a SIMATIC NET IE TP Cord M12-180\/RJ45-180, a pre-assembled Industrial Ethernet patch cable with an M12-180 X-coded connector at one end and an RJ45 connector at the other, on a 2 m S\/FTP Cat6A run. It carries PoE, PoE+, and PoE++, connecting an IP65\/IP67 M12 field device such as SCALANCE W or X to a standard IP20 RJ45 switch port.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5TH20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169857789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/RJ45-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Cores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard for Structured Cabling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor connecting Industrial Ethernet stations with an M12 interface (e.g. SCALANCE W and SCALANCE X)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 10 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 100 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 300 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 600 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance (1-100 MHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 100 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 300 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 600 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Resistance per Length (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage (RMS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNVP Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e68%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of Shield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil, sheathed in a protective braided shield of tinned copper wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Diameter (AWG26 insulated conductor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Inner Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTolerance of Outer Diameter (Cable Sheath)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Data Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ewhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Single Bend (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Multiple Bends (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Load (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight per Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire Behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Mineral Oil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Grease\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Water\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV Radiation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\/67 (M12), IP20 (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHalogen-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE+ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE++ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSilicon-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL\/ETL Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, 300 V rating, AWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertificate of Suitability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.122 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85444210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 2 m this is the longest length in the M12-180\/RJ45-180 line, giving enough slack to route from a cabinet-mounted switch to an M12 gland entry across a larger panel without a mid-run coupler. As with the shorter-length variants, keep the IP20 RJ45 end inside the enclosure and check the 65 mm multiple-bend radius at any turn.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959474675995,"sku":"6XV1878-5TH20","price":78.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5th20-ie-tp-cord-m12-rj45-network-cable.png?v=1790183415"},{"product_id":"siemens-6xv1878-5th30-ie-tp-cord-m12-rj45-3m-cable","title":"Siemens 6XV1878-5TH30 SIMATIC NET IE TP Cord M12-180\/RJ45-180 3m Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5TH30 is a pre-assembled IE TP Cord from the SIMATIC NET family, fitted with one M12 plug (X-coded, 180-degree cable outlet) and one RJ45 plug (180-degree cable outlet), in a 3 m length. Built as an S\/FTP, Cat6A-rated cable with PoE++ support and IP65\/67 protection at the M12 end, it links Industrial Ethernet stations such as SCALANCE W and SCALANCE X.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog No \/ SKU\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5TH30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/RJ45-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169857796\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Length\u003c\/td\u003e\n\u003ctd\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Designation\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Connections\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 10 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 100 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 300 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 600 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance (1-100 MHz)\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk at 100 MHz\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk at 300 MHz\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk at 600 MHz\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Resistance (max)\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance Coefficient\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage (RMS)\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNVP Value\u003c\/td\u003e\n\u003ctd\u003e68 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Cores\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield Design\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil, braided tinned copper shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Diameter (AWG26 conductor)\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner Sheath Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Diameter Tolerance\u003c\/td\u003e\n\u003ctd\u003e0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Material\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Material\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Wire Insulation Colors\u003c\/td\u003e\n\u003ctd\u003ewhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Bending Radius (single bend)\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Bending Radius (multiple bends)\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Tensile Load\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight per Length\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (this length)\u003c\/td\u003e\n\u003ctd\u003e0.166 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Behavior\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Mineral Oil\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Grease\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Water\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUV Radiation Resistance\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class (IP)\u003c\/td\u003e\n\u003ctd\u003eIP65\/67 (M12), IP20 (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHalogen-Free\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE+ Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE++ Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilicon-Free\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/ETL Listing (300 V rating)\u003c\/td\u003e\n\u003ctd\u003eYes, AWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Suitability\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStructured Cabling Standard\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 3 m, this cord suits runs where the M12-to-RJ45 pairing needs to reach past the IP65\/67 M12 boundary into a standard IP20 RJ45 port without a field-terminated joint. The 100 N maximum tensile load and 32.5 mm single-bend radius set the routing limits for this length; for longer or shorter runs, pick the sibling cord length instead of extending or shortening this one. PoE++ support means the same cord can carry both data and device power over the run.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959474708763,"sku":"6XV1878-5TH30","price":89.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5th30-ie-tp-cord-m12-rj45-network-cable.png?v=1790183421"},{"product_id":"siemens-6xv1878-5th50-ie-tp-cord-m12-rj45-5m-cable","title":"Siemens 6XV1878-5TH50 SIMATIC NET IE TP Cord M12-180\/RJ45-180 5m Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5TH50 is a pre-assembled IE TP Cord from the SIMATIC NET family, fitted with one M12 plug (X-coded, 180-degree cable outlet) and one RJ45 plug (180-degree cable outlet), in a 5 m length. Built as an S\/FTP, Cat6A-rated cable with PoE++ support and IP65\/67 protection at the M12 end, it links Industrial Ethernet stations such as SCALANCE W and SCALANCE X.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog No \/ SKU\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5TH50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/RJ45-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169857802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Length\u003c\/td\u003e\n\u003ctd\u003e5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Designation\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Connections\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 10 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 100 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 300 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 600 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance (1-100 MHz)\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk at 100 MHz\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk at 300 MHz\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk at 600 MHz\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Resistance (max)\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance Coefficient\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage (RMS)\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNVP Value\u003c\/td\u003e\n\u003ctd\u003e68 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Cores\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield Design\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil, braided tinned copper shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Diameter (AWG26 conductor)\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner Sheath Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Diameter Tolerance\u003c\/td\u003e\n\u003ctd\u003e0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Material\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Material\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Wire Insulation Colors\u003c\/td\u003e\n\u003ctd\u003ewhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Bending Radius (single bend)\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Bending Radius (multiple bends)\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Tensile Load\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight per Length\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (this length)\u003c\/td\u003e\n\u003ctd\u003e0.026 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Behavior\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Mineral Oil\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Grease\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Water\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUV Radiation Resistance\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class (IP)\u003c\/td\u003e\n\u003ctd\u003eIP65\/67 (M12), IP20 (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHalogen-Free\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE+ Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE++ Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilicon-Free\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/ETL Listing (300 V rating)\u003c\/td\u003e\n\u003ctd\u003eYes, AWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Suitability\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStructured Cabling Standard\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 5 m, this cord suits runs where the M12-to-RJ45 pairing needs to reach past the IP65\/67 M12 boundary into a standard IP20 RJ45 port without a field-terminated joint. The 100 N maximum tensile load and 32.5 mm single-bend radius set the routing limits for this length; for longer or shorter runs, pick the sibling cord length instead of extending or shortening this one. PoE++ support means the same cord can carry both data and device power over the run.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959474741531,"sku":"6XV1878-5TH50","price":111.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5th50-ie-tp-cord-m12-rj45-network-cable.png?v=1790183428"},{"product_id":"siemens-6xv1878-5tn10-ie-tp-cord-m12-rj45-10m-cable","title":"Siemens 6XV1878-5TN10 SIMATIC NET IE TP Cord M12-180\/RJ45-180 10m Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5TN10 is a pre-assembled IE TP Cord from the SIMATIC NET family, fitted with one M12 plug (X-coded, 180-degree cable outlet) and one RJ45 plug (180-degree cable outlet), in a 10 m length. Built as an S\/FTP, Cat6A-rated cable with PoE++ support and IP65\/67 protection at the M12 end, it links Industrial Ethernet stations such as SCALANCE W and SCALANCE X.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog No \/ SKU\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5TN10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/RJ45-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169857819\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Length\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Designation\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Connections\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 10 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 100 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 300 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 600 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance (1-100 MHz)\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk at 100 MHz\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk at 300 MHz\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk at 600 MHz\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Resistance (max)\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance Coefficient\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage (RMS)\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNVP Value\u003c\/td\u003e\n\u003ctd\u003e68 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Cores\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield Design\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil, braided tinned copper shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Diameter (AWG26 conductor)\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner Sheath Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Diameter Tolerance\u003c\/td\u003e\n\u003ctd\u003e0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Material\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Material\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Wire Insulation Colors\u003c\/td\u003e\n\u003ctd\u003ewhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Bending Radius (single bend)\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Bending Radius (multiple bends)\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Tensile Load\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight per Length\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (this length)\u003c\/td\u003e\n\u003ctd\u003e0.49 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Behavior\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Mineral Oil\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Grease\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Water\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUV Radiation Resistance\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class (IP)\u003c\/td\u003e\n\u003ctd\u003eIP65\/67 (M12), IP20 (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHalogen-Free\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE+ Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE++ Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilicon-Free\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/ETL Listing (300 V rating)\u003c\/td\u003e\n\u003ctd\u003eYes, AWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Suitability\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStructured Cabling Standard\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 10 m, this cord suits runs where the M12-to-RJ45 pairing needs to reach past the IP65\/67 M12 boundary into a standard IP20 RJ45 port without a field-terminated joint. The 100 N maximum tensile load and 32.5 mm single-bend radius set the routing limits for this length; for longer or shorter runs, pick the sibling cord length instead of extending or shortening this one. PoE++ support means the same cord can carry both data and device power over the run.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959474807067,"sku":"6XV1878-5TN10","price":177.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5tn10-ie-tp-cord-m12-rj45-network-cable.png?v=1790183434"},{"product_id":"siemens-6xv1878-5tn15-ie-tp-cord-m12-rj45-15m-cable","title":"Siemens 6XV1878-5TN15 SIMATIC NET IE TP Cord M12-180\/RJ45-180 15m Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5TN15 is a pre-assembled IE TP Cord from the SIMATIC NET family, fitted with one M12 plug (X-coded, 180-degree cable outlet) and one RJ45 plug (180-degree cable outlet), in a 15 m length. Built as an S\/FTP, Cat6A-rated cable with PoE++ support and IP65\/67 protection at the M12 end, it links Industrial Ethernet stations such as SCALANCE W and SCALANCE X.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog No \/ SKU\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5TN15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/RJ45-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169857826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Length\u003c\/td\u003e\n\u003ctd\u003e15 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Designation\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Connections\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 10 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 100 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 300 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 600 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance (1-100 MHz)\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk at 100 MHz\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk at 300 MHz\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk at 600 MHz\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Resistance (max)\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance Coefficient\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage (RMS)\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNVP Value\u003c\/td\u003e\n\u003ctd\u003e68 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Cores\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield Design\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil, braided tinned copper shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Diameter (AWG26 conductor)\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner Sheath Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Diameter Tolerance\u003c\/td\u003e\n\u003ctd\u003e0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Material\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Material\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Wire Insulation Colors\u003c\/td\u003e\n\u003ctd\u003ewhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Bending Radius (single bend)\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Bending Radius (multiple bends)\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Tensile Load\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight per Length\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (this length)\u003c\/td\u003e\n\u003ctd\u003e0.738 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Behavior\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Mineral Oil\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Grease\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Water\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUV Radiation Resistance\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class (IP)\u003c\/td\u003e\n\u003ctd\u003eIP65\/67 (M12), IP20 (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHalogen-Free\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE+ Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE++ Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilicon-Free\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/ETL Listing (300 V rating)\u003c\/td\u003e\n\u003ctd\u003eYes, AWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Suitability\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStructured Cabling Standard\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 15 m, this cord suits runs where the M12-to-RJ45 pairing needs to reach past the IP65\/67 M12 boundary into a standard IP20 RJ45 port without a field-terminated joint. The 100 N maximum tensile load and 32.5 mm single-bend radius set the routing limits for this length; for longer or shorter runs, pick the sibling cord length instead of extending or shortening this one. PoE++ support means the same cord can carry both data and device power over the run.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959474839835,"sku":"6XV1878-5TN15","price":224.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5tn15-ie-tp-cord-m12-rj45-network-cable.png?v=1790183439"},{"product_id":"siemens-6xv1878-5tn30-ie-tp-cord-m12-rj45-30m-cable","title":"Siemens 6XV1878-5TN30 SIMATIC NET IE TP Cord M12-180\/RJ45-180 30m Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5TN30 is a pre-assembled IE TP Cord from the SIMATIC NET family, fitted with one M12 plug (X-coded, 180-degree cable outlet) and one RJ45 plug (180-degree cable outlet), in a 30 m length. Built as an S\/FTP, Cat6A-rated cable with PoE++ support and IP65\/67 protection at the M12 end, it links Industrial Ethernet stations such as SCALANCE W and SCALANCE X.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog No \/ SKU\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5TN30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/RJ45-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169858069\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Length\u003c\/td\u003e\n\u003ctd\u003e30 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Designation\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Connections\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 10 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 100 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 300 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 600 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance (1-100 MHz)\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk at 100 MHz\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk at 300 MHz\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk at 600 MHz\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Resistance (max)\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance Coefficient\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage (RMS)\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNVP Value\u003c\/td\u003e\n\u003ctd\u003e68 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Cores\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield Design\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil, braided tinned copper shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Diameter (AWG26 conductor)\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner Sheath Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Diameter Tolerance\u003c\/td\u003e\n\u003ctd\u003e0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Material\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Material\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Wire Insulation Colors\u003c\/td\u003e\n\u003ctd\u003ewhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Bending Radius (single bend)\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Bending Radius (multiple bends)\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Tensile Load\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight per Length\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (this length)\u003c\/td\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Behavior\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Mineral Oil\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Grease\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Water\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUV Radiation Resistance\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class (IP)\u003c\/td\u003e\n\u003ctd\u003eIP65\/67 (M12), IP20 (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHalogen-Free\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE+ Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE++ Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilicon-Free\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/ETL Listing (300 V rating)\u003c\/td\u003e\n\u003ctd\u003eYes, AWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Suitability\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStructured Cabling Standard\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 30 m, this cord suits runs where the M12-to-RJ45 pairing needs to reach past the IP65\/67 M12 boundary into a standard IP20 RJ45 port without a field-terminated joint. The 100 N maximum tensile load and 32.5 mm single-bend radius set the routing limits for this length; for longer or shorter runs, pick the sibling cord length instead of extending or shortening this one. PoE++ support means the same cord can carry both data and device power over the run.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959475036443,"sku":"6XV1878-5TN30","price":319.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5tn30-ie-tp-cord-m12-rj45-network-cable.png?v=1790183445"},{"product_id":"siemens-6xv1878-5tn50-ie-tp-cord-m12-rj45-50m-cable","title":"Siemens 6XV1878-5TN50 SIMATIC NET IE TP Cord M12-180\/RJ45-180 50m Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5TN50 is a pre-assembled IE TP Cord from the SIMATIC NET family, fitted with one M12 plug (X-coded, 180-degree cable outlet) and one RJ45 plug (180-degree cable outlet), in a 50 m length. Built as an S\/FTP, Cat6A-rated cable with PoE++ support and IP65\/67 protection at the M12 end, it links Industrial Ethernet stations such as SCALANCE W and SCALANCE X.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog No \/ SKU\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5TN50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/RJ45-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169858076\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Length\u003c\/td\u003e\n\u003ctd\u003e50 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Designation\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Connections\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 10 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 100 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 300 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 600 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance (1-100 MHz)\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk at 100 MHz\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk at 300 MHz\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk at 600 MHz\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Resistance (max)\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance Coefficient\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage (RMS)\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNVP Value\u003c\/td\u003e\n\u003ctd\u003e68 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Cores\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield Design\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil, braided tinned copper shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Diameter (AWG26 conductor)\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner Sheath Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Diameter Tolerance\u003c\/td\u003e\n\u003ctd\u003e0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Material\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Material\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Wire Insulation Colors\u003c\/td\u003e\n\u003ctd\u003ewhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Bending Radius (single bend)\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin. Bending Radius (multiple bends)\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Tensile Load\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight per Length\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (this length)\u003c\/td\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Behavior\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Mineral Oil\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Grease\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Water\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUV Radiation Resistance\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class (IP)\u003c\/td\u003e\n\u003ctd\u003eIP65\/67 (M12), IP20 (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHalogen-Free\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE+ Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE++ Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilicon-Free\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/ETL Listing (300 V rating)\u003c\/td\u003e\n\u003ctd\u003eYes, AWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Suitability\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStructured Cabling Standard\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 50 m, this cord suits runs where the M12-to-RJ45 pairing needs to reach past the IP65\/67 M12 boundary into a standard IP20 RJ45 port without a field-terminated joint. The 100 N maximum tensile load and 32.5 mm single-bend radius set the routing limits for this length; for longer or shorter runs, pick the sibling cord length instead of extending or shortening this one. PoE++ support means the same cord can carry both data and device power over the run.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959475069211,"sku":"6XV1878-5TN50","price":472.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5tn50-ie-tp-cord-m12-rj45-network-cable.png?v=1790183451"},{"product_id":"siemens-6es7972-0ab01-0xa0-diagnostic-repeater-profibus","title":"Siemens 6ES7972-0AB01-0XA0 SIMATIC NET Diagnostic Repeater PROFIBUS DP 12 Mbit\/s IP20","description":"\u003cp\u003eThe Siemens 6ES7972-0AB01-0XA0 is a diagnostic repeater for PROFIBUS DP, running online diagnostics of the bus cable while it repeats the signal, in an IP20 housing with FastConnect terminals. It transmits from 9.6 kbit\/s up to 12 Mbit\/s and appears on the bus itself as a PROFIBUS DP standard slave, powered from 24 V DC.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6ES7972-0AB01-0XA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4025515069256\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eDiagnostic repeater for PROFIBUS DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Role\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP standard slave, up to 12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage, rated (DC)\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage, permissible range (DC)\u003c\/td\u003e\n\u003ctd\u003e20.4 V to 28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate, max.\u003c\/td\u003e\n\u003ctd\u003e12 Mbit\/s (9.6 kbit\/s to 12 Mbit\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection, Supply Voltage\u003c\/td\u003e\n\u003ctd\u003eTerminal module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection, PROFIBUS Cable\u003c\/td\u003e\n\u003ctd\u003eFastConnect insulation displacement, 10 clamping cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss, typ.\u003c\/td\u003e\n\u003ctd\u003e4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e0 °C to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Storage\/Transport\u003c\/td\u003e\n\u003ctd\u003e-40 °C to 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity, Operation, max.\u003c\/td\u003e\n\u003ctd\u003e95% at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e80 mm x 125 mm x 67.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAdd this repeater to a PROFIBUS DP trunk when the segment needs both signal regeneration and online cable diagnostics, for example a long run or one prone to connector faults; it reports cable status back to the master because it sits on the bus as its own DP slave, not as a passive line amplifier. FastConnect terminals cut installation time versus screw-clamp repeaters on the same PROFIBUS trunk.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959581434139,"sku":"6ES7972-0AB01-0XA0","price":1373.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7972-0ab01-0xa0-profibus-dp-diagnostic-repeater.png?v=1789799427"}],"url":"https:\/\/stoklink.com\/collections\/industrial-network-cables.oembed?page=10","provider":"Stoklink","version":"1.0","type":"link"}