{"title":"Industrial Ethernet Switches","description":"\u003cp\u003eIndustrial Ethernet switches from Siemens, Schneider Electric and Harting. The range has over 150 managed and modular switches, including SCALANCE XB, XC, XR and XM, and Modicon managed switches with SFP fiber ports. Stoklink ships worldwide from Turkey and quotes project volumes on request.\u003c\/p\u003e\n\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSCALANCE XB and XC compact switches, for example XC206 and XC208.\u003c\/li\u003e\n\u003cli\u003eSCALANCE XR rack switches from 24 ports, with 230 V AC or 24 V DC supply.\u003c\/li\u003e\n\u003cli\u003eSCALANCE XM modular switches with 10G options.\u003c\/li\u003e\n\u003cli\u003eRailway and PoE switches with M12 ports, such as XP216PoE EEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow to choose\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePort count: total copper and fiber ports, plus spares.\u003c\/li\u003e\n\u003cli\u003eManaged layer: Layer 2 for standard plants, Layer 3 where routing between VLANs is needed.\u003c\/li\u003e\n\u003cli\u003eUplink speed: Gigabit or 10G between switches.\u003c\/li\u003e\n\u003cli\u003eRedundancy: ring protocols such as MRP or RSTP for fault-tolerant topologies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhat does the RJ45 versus fiber port choice depend on?\u003c\/h3\u003e\n\u003cp\u003eCopper RJ45 reaches 100 m. Fiber is used for longer runs and electrically noisy areas, using SFP or built-in SC ports.\u003c\/p\u003e\n\u003ch3\u003eDo SCALANCE switches support PROFINET?\u003c\/h3\u003e\n\u003cp\u003eYes. Managed SCALANCE switches support PROFINET diagnostics, so the PLC can read switch status.\u003c\/p\u003e\n\u003ch3\u003eDo you ship switches outside Turkey?\u003c\/h3\u003e\n\u003cp\u003eStoklink ships worldwide from Turkey under EXW terms. Lead time depends on distributor stock, and project quantities are quoted on request.\u003c\/p\u003e","products":[{"product_id":"siemens-6gk5534-2tr00-2ar3-scalance-xr526-8-switch","title":"Siemens 6GK5534-2TR00-2AR3 SCALANCE XR526-8 Layer 3 Switch, 24V DC, 8x SFP+ 10G","description":"\u003cp\u003eThe Siemens SCALANCE XR526-8 (6GK5534-2TR00-2AR3) is a 19-inch rack, Layer 3 managed Ethernet switch with 24x 10\/100\/1000 Mbit\/s RJ45 ports, 2x combo 1G\/2.5G\/5G\/10G RJ45 ports, and 8x SFP+ ports for 1 or 10 Gbit\/s uplinks. It runs from a single 24V DC supply and integrates a redundancy manager for ring topologies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5534-2TR00-2AR3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622989517\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR526\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType Designation\u003c\/td\u003e\n\u003ctd\u003eXR526-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Config\u003c\/td\u003e\n\u003ctd\u003eSingle, 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 1 HU, metal enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e446 x 43.6 x 374.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eFanless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation, horizontal)\u003c\/td\u003e\n\u003ctd\u003e-40 ... +60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude (max)\u003c\/td\u003e\n\u003ctd\u003e4000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (max, at 25 C)\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 Ports (10\/100\/1000 Mbit\/s)\u003c\/td\u003e\n\u003ctd\u003e24, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombo RJ45 Ports (1G\/2.5G\/5G\/10G)\u003c\/td\u003e\n\u003ctd\u003e2, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP+ Ports (1000\/10000 Mbit\/s)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator Console\u003c\/td\u003e\n\u003ctd\u003e1x USB 2.0 Type B (USB-to-serial adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling Contact\u003c\/td\u003e\n\u003ctd\u003e1x 2-pole terminal block, 24V DC, 0.1A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e1x 24V DC, 2x 2-pole terminal block, range 19.2-31.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant Power Input\u003c\/td\u003e\n\u003ctd\u003eConnection for redundant voltage supply provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss (rated)\u003c\/td\u003e\n\u003ctd\u003e72W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current Consumption\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Protection\u003c\/td\u003e\n\u003ctd\u003eF 10A \/ 250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eCLP included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eB, network load class III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Telegram Length\u003c\/td\u003e\n\u003ctd\u003e9194 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLANs\u003c\/td\u003e\n\u003ctd\u003e257 (257 at ring redundancy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Learnable MAC Addresses\u003c\/td\u003e\n\u003ctd\u003e16382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQoS Queues per Port\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Protocols\u003c\/td\u003e\n\u003ctd\u003eMRP with redundancy manager, MRP-I, PROFINET system redundancy, HRP, HSR, PRP, STP, RSTP, RSTP+, MSTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRouting Protocols\u003c\/td\u003e\n\u003ctd\u003eStatic and dynamic IP routing, RIPv2, OSPFv2, VRRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Protocols\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, Telnet, TFTP, FTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP snooping\/querier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eUL HazLoc\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 2AR3 variant is the DC-only version: a single 24V DC input with a spare terminal block for a second, redundant 24V feed - the option to pick when the cabinet already runs on a 24V DC bus. Pick the 3AR3 sibling instead for AC mains supply, or 4AR3 for a factory-fitted redundant AC pair. With Layer 3 routing (RIPv2, OSPFv2, VRRP) and 8x SFP+ 10 Gbit\/s ports, the XR526-8 works as a distribution switch feeding multiple access-layer rings.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe 24-port RJ45 count plus 8x 10 Gbit\/s SFP+ uplinks suit machine-building panels that aggregate several PROFINET rings into a plant backbone, with MRP and HSR\/PRP available for loss-free ring and parallel-redundant topologies.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959424835867,"sku":"6GK5534-2TR00-2AR3","price":5080.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5534-2tr00-2ar3-scalance-xr526-8-industrial-ethernet-switch.png?v=1789825288"},{"product_id":"siemens-6gk5534-2tr00-3ar3-scalance-xr526-8-switch","title":"Siemens 6GK5534-2TR00-3AR3 SCALANCE XR526-8 Layer 3 Switch, 230V AC, 8x SFP+ 10G","description":"\u003cp\u003eThe Siemens SCALANCE XR526-8 (6GK5534-2TR00-3AR3) is a 19-inch rack, Layer 3 managed Ethernet switch with 24x 10\/100\/1000 Mbit\/s RJ45 ports, 2x combo 1G\/2.5G\/5G\/10G RJ45 ports, and 8x SFP+ ports for 1 or 10 Gbit\/s uplinks. It runs from a single 100-240V AC\/DC-rated supply on an IEC C14 inlet and integrates a redundancy manager for ring topologies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5534-2TR00-3AR3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622989524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR526\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType Designation\u003c\/td\u003e\n\u003ctd\u003eXR526-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Config\u003c\/td\u003e\n\u003ctd\u003eSingle, IEC C14, 100-240V AC or 100-250V DC rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 1 HU, metal enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e446 x 43.6 x 374.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e8.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eFanless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation, horizontal)\u003c\/td\u003e\n\u003ctd\u003e-25 ... +60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude (max)\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (max, at 25 C)\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 Ports (10\/100\/1000 Mbit\/s)\u003c\/td\u003e\n\u003ctd\u003e24, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombo RJ45 Ports (1G\/2.5G\/5G\/10G)\u003c\/td\u003e\n\u003ctd\u003e2, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP+ Ports (1000\/10000 Mbit\/s)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator Console\u003c\/td\u003e\n\u003ctd\u003e1x USB 2.0 Type B (USB-to-serial adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling Contact\u003c\/td\u003e\n\u003ctd\u003e1x 2-pole terminal block, 24V DC, 0.1A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply - AC Rating\u003c\/td\u003e\n\u003ctd\u003e100-240V AC, range 85-264V, IEC plug C14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply - DC Rating\u003c\/td\u003e\n\u003ctd\u003e100-250V DC, range 77-300V, 2-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss (rated)\u003c\/td\u003e\n\u003ctd\u003e99W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current Consumption\u003c\/td\u003e\n\u003ctd\u003e0.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Protection\u003c\/td\u003e\n\u003ctd\u003eF 4A \/ 250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eCLP included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eB, network load class III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Telegram Length\u003c\/td\u003e\n\u003ctd\u003e9194 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLANs\u003c\/td\u003e\n\u003ctd\u003e257 (257 at ring redundancy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Learnable MAC Addresses\u003c\/td\u003e\n\u003ctd\u003e16382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQoS Queues per Port\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Protocols\u003c\/td\u003e\n\u003ctd\u003eMRP with redundancy manager, MRP-I, PROFINET system redundancy, HRP, HSR, PRP, STP, RSTP, RSTP+, MSTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRouting Protocols\u003c\/td\u003e\n\u003ctd\u003eStatic and dynamic IP routing, RIPv2, OSPFv2, VRRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Protocols\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, Telnet, TFTP, FTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP snooping\/querier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 3AR3 variant takes a single AC mains feed on an IEC C14 inlet (the same terminal also accepts 100-250V DC) - the option to pick when the panel has mains AC available and a second supply isn't required. Pick the 2AR3 sibling for a 24V DC bus instead, or 4AR3 for a factory-fitted redundant pair of AC\/DC supplies. With Layer 3 routing (RIPv2, OSPFv2, VRRP) and 8x SFP+ 10 Gbit\/s ports, the XR526-8 works as a distribution switch feeding multiple access-layer rings.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe 24-port RJ45 count plus 8x 10 Gbit\/s SFP+ uplinks suit machine-building panels that aggregate several PROFINET rings into a plant backbone, with MRP and HSR\/PRP available for loss-free ring and parallel-redundant topologies.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959424934171,"sku":"6GK5534-2TR00-3AR3","price":5201.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5534-2tr00-3ar3-scalance-xr526-8-industrial-ethernet-switch.png?v=1789825294"},{"product_id":"siemens-6gk5534-2tr00-4ar3-scalance-xr526-8-switch","title":"Siemens 6GK5534-2TR00-4AR3 SCALANCE XR526-8 Layer 3 Switch, Redundant 230V AC PSU","description":"\u003cp\u003eThe Siemens SCALANCE XR526-8 (6GK5534-2TR00-4AR3) is a 19-inch rack, Layer 3 managed Ethernet switch with 24x 10\/100\/1000 Mbit\/s RJ45 ports, 2x combo 1G\/2.5G\/5G\/10G RJ45 ports, and 8x SFP+ ports for 1 or 10 Gbit\/s uplinks. Two independent 100-240V AC\/DC-rated supplies on IEC C14 inlets give power redundancy alongside the integrated redundancy manager for ring topologies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5534-2TR00-4AR3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622989531\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR526\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType Designation\u003c\/td\u003e\n\u003ctd\u003eXR526-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Config\u003c\/td\u003e\n\u003ctd\u003eRedundant, 2x IEC C14, 100-240V AC or 100-250V DC rated each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 1 HU, metal enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e446 x 43.6 x 374.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e8.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eFanless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation, horizontal)\u003c\/td\u003e\n\u003ctd\u003e-25 ... +60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude (max)\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (max, at 25 C)\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 Ports (10\/100\/1000 Mbit\/s)\u003c\/td\u003e\n\u003ctd\u003e24, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombo RJ45 Ports (1G\/2.5G\/5G\/10G)\u003c\/td\u003e\n\u003ctd\u003e2, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP+ Ports (1000\/10000 Mbit\/s)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator Console\u003c\/td\u003e\n\u003ctd\u003e1x USB 2.0 Type B (USB-to-serial adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling Contact\u003c\/td\u003e\n\u003ctd\u003e1x 2-pole terminal block, 24V DC, 0.1A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply - AC Rating (each)\u003c\/td\u003e\n\u003ctd\u003e100-240V AC, range 85-264V, IEC plug C14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply - DC Rating (each)\u003c\/td\u003e\n\u003ctd\u003e100-250V DC, range 77-300V, 2-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss (rated, each supply)\u003c\/td\u003e\n\u003ctd\u003e99W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current Consumption (each)\u003c\/td\u003e\n\u003ctd\u003e0.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Protection (each)\u003c\/td\u003e\n\u003ctd\u003eF 4A \/ 250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eCLP included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eB, network load class III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Telegram Length\u003c\/td\u003e\n\u003ctd\u003e9194 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLANs\u003c\/td\u003e\n\u003ctd\u003e257 (257 at ring redundancy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Learnable MAC Addresses\u003c\/td\u003e\n\u003ctd\u003e16382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQoS Queues per Port\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Protocols\u003c\/td\u003e\n\u003ctd\u003eMRP with redundancy manager, MRP-I, PROFINET system redundancy, HRP, HSR, PRP, STP, RSTP, RSTP+, MSTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRouting Protocols\u003c\/td\u003e\n\u003ctd\u003eStatic and dynamic IP routing, RIPv2, OSPFv2, VRRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Protocols\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, Telnet, TFTP, FTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP snooping\/querier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 4AR3 variant adds a second, independent AC\/DC-rated supply input for power redundancy - the option to pick when a single feed failure must not take the backbone switch down. Pick the 3AR3 sibling instead if a single mains feed is acceptable, or 2AR3 for a 24V DC-only bus. With Layer 3 routing (RIPv2, OSPFv2, VRRP) and 8x SFP+ 10 Gbit\/s ports, the XR526-8 works as a distribution switch feeding multiple access-layer rings, and dual power inputs pair naturally with dual-fed cabinets.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe redundant supply inputs suit critical plant backbones where the switch itself must not become a single point of failure, while the 24-port RJ45 count plus 8x 10 Gbit\/s SFP+ uplinks aggregate several PROFINET rings with MRP, HSR or PRP redundancy.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959427391771,"sku":"6GK5534-2TR00-4AR3","price":5322.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5534-2tr00-4ar3-scalance-xr526-8-industrial-ethernet-switch.png?v=1789825301"},{"product_id":"siemens-6gk5534-3tr00-2ar3-scalance-xr522-12-switch","title":"Siemens 6GK5534-3TR00-2AR3 SCALANCE XR522-12 Layer 3 Switch, 24V DC, 8x SFP+ 10G","description":"\u003cp\u003eThe Siemens SCALANCE XR522-12 (6GK5534-3TR00-2AR3) is a 19-inch rack, Layer 3 managed Ethernet switch with 20x 10\/100\/1000 Mbit\/s RJ45 ports, 2x combo 1G\/2.5G\/5G\/10G RJ45 ports, 4x SFP ports, and 8x SFP+ ports for 10 Gbit\/s uplinks. It runs from a single 24V DC supply and integrates a redundancy manager for ring topologies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5534-3TR00-2AR3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622989548\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR522\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType Designation\u003c\/td\u003e\n\u003ctd\u003eXR522-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Config\u003c\/td\u003e\n\u003ctd\u003eSingle, 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 1 HU, metal enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e446 x 43.6 x 374.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eFanless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation, horizontal)\u003c\/td\u003e\n\u003ctd\u003e-40 ... +60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude (max)\u003c\/td\u003e\n\u003ctd\u003e4000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (max, at 25 C)\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 Ports (10\/100\/1000 Mbit\/s)\u003c\/td\u003e\n\u003ctd\u003e20, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombo RJ45 Ports (1G\/2.5G\/5G\/10G)\u003c\/td\u003e\n\u003ctd\u003e2, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP Ports (100\/1000 Mbit\/s)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP+ Ports (1000\/10000 Mbit\/s)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator Console\u003c\/td\u003e\n\u003ctd\u003e1x USB 2.0 Type B (USB-to-serial adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling Contact\u003c\/td\u003e\n\u003ctd\u003e1x 2-pole terminal block, 24V DC, 0.1A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e1x 24V DC, 2x 2-pole terminal block, range 19.2-31.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant Power Input\u003c\/td\u003e\n\u003ctd\u003eConnection for redundant voltage supply provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss (rated)\u003c\/td\u003e\n\u003ctd\u003e72W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current Consumption\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Protection\u003c\/td\u003e\n\u003ctd\u003eF 10A \/ 250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eCLP included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eB, network load class III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Telegram Length\u003c\/td\u003e\n\u003ctd\u003e9194 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLANs\u003c\/td\u003e\n\u003ctd\u003e257 (257 at ring redundancy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Learnable MAC Addresses\u003c\/td\u003e\n\u003ctd\u003e16382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQoS Queues per Port\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Protocols\u003c\/td\u003e\n\u003ctd\u003eMRP with redundancy manager, MRP-I, PROFINET system redundancy, HRP, HSR, PRP, RSTP, RSTP+, MSTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRouting Protocols\u003c\/td\u003e\n\u003ctd\u003eStatic and dynamic IP routing, RIPv2, OSPFv2, VRRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Protocols\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, Telnet, TFTP, FTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP snooping\/querier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eUL HazLoc\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 2AR3 variant is the DC-only version: a single 24V DC input with a spare terminal block for a second, redundant 24V feed - the option to pick when the cabinet already runs on a 24V DC bus. Pick the 3AR3 sibling instead for AC mains supply, or 4AR3 for a factory-fitted redundant AC pair. Against the larger XR526-8, the XR522-12 trades 4 RJ45 ports for 4 extra SFP slots, which suits sites standardizing on fiber for a subset of access links.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe mixed RJ45\/SFP\/SFP+ port set fits distribution cabinets that combine copper drops to local PROFINET devices with fiber runs to remote panels, using MRP or HSR\/PRP for ring redundancy across the plant backbone.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959427522843,"sku":"6GK5534-3TR00-2AR3","price":5322.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5534-3tr00-2ar3-scalance-xr522-12-industrial-ethernet-switch.png?v=1789825308"},{"product_id":"siemens-6gk5534-3tr00-3ar3-scalance-xr522-12-switch","title":"Siemens 6GK5534-3TR00-3AR3 SCALANCE XR522-12 Layer 3 Switch, 230V AC, 8x SFP+ 10G","description":"\u003cp\u003eThe Siemens SCALANCE XR522-12 (6GK5534-3TR00-3AR3) is a 19-inch rack, Layer 3 managed Ethernet switch with 20x 10\/100\/1000 Mbit\/s RJ45 ports, 2x combo 1G\/2.5G\/5G\/10G RJ45 ports, 4x SFP ports, and 8x SFP+ ports for 10 Gbit\/s uplinks. It runs from a single 100-240V AC\/DC-rated supply on an IEC C14 inlet and integrates a redundancy manager for ring topologies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5534-3TR00-3AR3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622989555\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR522\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType Designation\u003c\/td\u003e\n\u003ctd\u003eXR522-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Config\u003c\/td\u003e\n\u003ctd\u003eSingle, IEC C14, 100-240V AC or 100-250V DC rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 1 HU, metal enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e446 x 43.6 x 374.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e8.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eFanless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation, horizontal)\u003c\/td\u003e\n\u003ctd\u003e-25 ... +60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude (max)\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (max, at 25 C)\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 Ports (10\/100\/1000 Mbit\/s)\u003c\/td\u003e\n\u003ctd\u003e20, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombo RJ45 Ports (1G\/2.5G\/5G\/10G)\u003c\/td\u003e\n\u003ctd\u003e2, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP Ports (100\/1000 Mbit\/s)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP+ Ports (1000\/10000 Mbit\/s)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator Console\u003c\/td\u003e\n\u003ctd\u003e1x USB 2.0 Type B (USB-to-serial adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling Contact\u003c\/td\u003e\n\u003ctd\u003e1x 2-pole terminal block, 24V DC, 0.1A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply - AC Rating\u003c\/td\u003e\n\u003ctd\u003e100-240V AC, range 85-264V, IEC plug C14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply - DC Rating\u003c\/td\u003e\n\u003ctd\u003e100-250V DC, range 77-300V, 2-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss (rated)\u003c\/td\u003e\n\u003ctd\u003e99W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current Consumption\u003c\/td\u003e\n\u003ctd\u003e0.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Protection\u003c\/td\u003e\n\u003ctd\u003eF 4A \/ 250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eCLP included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eB, network load class III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Telegram Length\u003c\/td\u003e\n\u003ctd\u003e9194 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLANs\u003c\/td\u003e\n\u003ctd\u003e257 (257 at ring redundancy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Learnable MAC Addresses\u003c\/td\u003e\n\u003ctd\u003e16382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQoS Queues per Port\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Protocols\u003c\/td\u003e\n\u003ctd\u003eMRP with redundancy manager, MRP-I, PROFINET system redundancy, HRP, HSR, PRP, STP, RSTP, RSTP+, MSTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRouting Protocols\u003c\/td\u003e\n\u003ctd\u003eStatic and dynamic IP routing, RIPv2, OSPFv2, VRRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Protocols\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, Telnet, TFTP, FTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP snooping\/querier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 3AR3 variant takes a single AC mains feed on an IEC C14 inlet (the same terminal also accepts 100-250V DC) - the option to pick when the panel has mains AC available and a second supply isn't required. Pick the 2AR3 sibling for a 24V DC bus instead, or 4AR3 for a factory-fitted redundant pair. Against the larger XR526-8, the XR522-12 trades 4 RJ45 ports for 4 extra SFP slots, which suits sites standardizing on fiber for part of the access layer.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe mixed RJ45\/SFP\/SFP+ port set fits distribution cabinets that combine copper drops to local PROFINET devices with fiber runs to remote panels, using MRP or HSR\/PRP for ring redundancy across the plant backbone.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959428047131,"sku":"6GK5534-3TR00-3AR3","price":5443.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5534-3tr00-3ar3-scalance-xr522-12-industrial-ethernet-switch.png?v=1789825314"},{"product_id":"siemens-6gk5534-3tr00-4ar3-scalance-xr522-12-switch","title":"Siemens 6GK5534-3TR00-4AR3 SCALANCE XR522-12 Layer 3 Switch, Redundant 230V AC PSU","description":"\u003cp\u003eThe Siemens SCALANCE XR522-12 (6GK5534-3TR00-4AR3) is a 19-inch rack, Layer 3 managed Ethernet switch with 20x 10\/100\/1000 Mbit\/s RJ45 ports, 2x combo 1G\/2.5G\/5G\/10G RJ45 ports, 4x SFP ports, and 8x SFP+ ports for 10 Gbit\/s uplinks. Two independent 100-240V AC\/DC-rated supplies on IEC C14 inlets give power redundancy alongside the integrated redundancy manager.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5534-3TR00-4AR3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622989562\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR522\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType Designation\u003c\/td\u003e\n\u003ctd\u003eXR522-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Config\u003c\/td\u003e\n\u003ctd\u003eRedundant, 2x IEC C14, 100-240V AC or 100-250V DC rated each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 1 HU, metal enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e446 x 43.6 x 374.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e8.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eFanless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation, horizontal)\u003c\/td\u003e\n\u003ctd\u003e-25 ... +60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude (max)\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (max, at 25 C)\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 Ports (10\/100\/1000 Mbit\/s)\u003c\/td\u003e\n\u003ctd\u003e20, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombo RJ45 Ports (1G\/2.5G\/5G\/10G)\u003c\/td\u003e\n\u003ctd\u003e2, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP Ports (100\/1000 Mbit\/s)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP+ Ports (1000\/10000 Mbit\/s)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator Console\u003c\/td\u003e\n\u003ctd\u003e1x USB 2.0 Type B (USB-to-serial adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling Contact\u003c\/td\u003e\n\u003ctd\u003e1x 2-pole terminal block, 24V DC, 0.1A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply - AC Rating (each)\u003c\/td\u003e\n\u003ctd\u003e100-240V AC, range 85-264V, IEC plug C14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply - DC Rating (each)\u003c\/td\u003e\n\u003ctd\u003e100-250V DC, range 77-300V, 2-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss (rated, each supply)\u003c\/td\u003e\n\u003ctd\u003e99W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current Consumption (each)\u003c\/td\u003e\n\u003ctd\u003e0.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Protection (each)\u003c\/td\u003e\n\u003ctd\u003eF 4A \/ 250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eCLP included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eB, network load class III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Telegram Length\u003c\/td\u003e\n\u003ctd\u003e9194 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLANs\u003c\/td\u003e\n\u003ctd\u003e257 (257 at ring redundancy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Learnable MAC Addresses\u003c\/td\u003e\n\u003ctd\u003e16382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQoS Queues per Port\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Protocols\u003c\/td\u003e\n\u003ctd\u003eMRP with redundancy manager, MRP-I, PROFINET system redundancy, HRP, HSR, PRP, STP, RSTP, RSTP+, MSTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRouting Protocols\u003c\/td\u003e\n\u003ctd\u003eStatic and dynamic IP routing, RIPv2, OSPFv2, VRRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Protocols\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, Telnet, TFTP, FTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP snooping\/querier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 4AR3 variant adds a second, independent AC\/DC-rated supply input for power redundancy - the option to pick when a single feed failure must not take the backbone switch down. Pick the 3AR3 sibling instead if a single mains feed is acceptable, or 2AR3 for a 24V DC-only bus. Against the larger XR526-8, the XR522-12 trades 4 RJ45 ports for 4 extra SFP slots, which suits sites standardizing on fiber for part of the access layer.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe redundant supply inputs suit critical distribution cabinets where the switch itself must not become a single point of failure, while the mixed RJ45\/SFP\/SFP+ port set combines copper drops with fiber runs across a PROFINET plant backbone.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959428407579,"sku":"6GK5534-3TR00-4AR3","price":5564.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5534-3tr00-4ar3-scalance-xr522-12-industrial-ethernet-switch.png?v=1789825320"},{"product_id":"siemens-6gk5534-5tr00-2ar3-scalance-xr502-32-switch","title":"Siemens 6GK5534-5TR00-2AR3 SCALANCE XR502-32 Layer 3 Switch, 24V DC, 8x SFP+ 10G","description":"\u003cp\u003eThe Siemens SCALANCE XR502-32 (6GK5534-5TR00-2AR3) is a 19-inch rack, Layer 3 managed Ethernet switch with 2x combo 1G\/2.5G\/5G\/10G RJ45 ports, 24x SFP ports, and 8x SFP+ ports for 10 Gbit\/s uplinks. It runs from a single 24V DC supply, supports installation up to 4000m altitude, and integrates a redundancy manager for ring topologies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5534-5TR00-2AR3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622989579\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR502\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType Designation\u003c\/td\u003e\n\u003ctd\u003eXR502-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Config\u003c\/td\u003e\n\u003ctd\u003eSingle, 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 1 HU, metal enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e446 x 43.6 x 374.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eFanless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation, horizontal)\u003c\/td\u003e\n\u003ctd\u003e-40 ... +55 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude (max)\u003c\/td\u003e\n\u003ctd\u003e4000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (max, at 25 C)\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombo RJ45 Ports (1G\/2.5G\/5G\/10G)\u003c\/td\u003e\n\u003ctd\u003e2, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP Ports (100\/1000 Mbit\/s)\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP+ Ports (1000\/10000 Mbit\/s)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator Console\u003c\/td\u003e\n\u003ctd\u003e1x USB 2.0 Type B (USB-to-serial adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling Contact\u003c\/td\u003e\n\u003ctd\u003e1x 2-pole terminal block, 24V DC, 0.1A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e1x 24V DC, 2x 2-pole terminal block, range 19.2-31.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant Power Input\u003c\/td\u003e\n\u003ctd\u003eConnection for redundant voltage supply provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss (rated)\u003c\/td\u003e\n\u003ctd\u003e72W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current Consumption\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Protection\u003c\/td\u003e\n\u003ctd\u003eF 10A \/ 250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eCLP included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eB, network load class III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Telegram Length\u003c\/td\u003e\n\u003ctd\u003e9194 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLANs\u003c\/td\u003e\n\u003ctd\u003e257 (257 at ring redundancy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Learnable MAC Addresses\u003c\/td\u003e\n\u003ctd\u003e16382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQoS Queues per Port\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Protocols\u003c\/td\u003e\n\u003ctd\u003eMRP with redundancy manager, MRP-I, PROFINET system redundancy, HRP, HSR, PRP, STP, RSTP, RSTP+, MSTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRouting Protocols\u003c\/td\u003e\n\u003ctd\u003eStatic and dynamic IP routing, RIPv2, OSPFv2, VRRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Protocols\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, Telnet, TFTP, FTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP snooping\/querier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eUL HazLoc\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 2AR3 variant is the DC-only version: a single 24V DC input with a spare terminal block for a second, redundant 24V feed - the option to pick when the cabinet already runs on a 24V DC bus. Pick the 3AR3 sibling instead for AC mains supply. With 24 SFP slots and only 2 RJ45 uplink ports, the XR502-32 is built for fiber-heavy access layers rather than copper-dense ones - use the XR526-8 or XR522-12 instead where most drops are RJ45.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe 24x SFP port count fits distribution cabinets aggregating long-haul fiber runs from multiple remote panels or rings, with the 8x SFP+ ports carrying the 10 Gbit\/s uplink back to the plant core.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959429030171,"sku":"6GK5534-5TR00-2AR3","price":4718.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5534-5tr00-2ar3-scalance-xr502-32-industrial-ethernet-switch.png?v=1789825325"},{"product_id":"siemens-6gk5534-5tr00-3ar3-scalance-xr502-32-switch","title":"Siemens 6GK5534-5TR00-3AR3 SCALANCE XR502-32 Layer 3 Switch, 230V AC, 8x SFP+ 10G","description":"\u003cp\u003eThe Siemens SCALANCE XR502-32 (6GK5534-5TR00-3AR3) is a 19-inch rack, Layer 3 managed Ethernet switch with 2x combo 1G\/2.5G\/5G\/10G RJ45 ports, 24x SFP ports, and 8x SFP+ ports for 10 Gbit\/s uplinks. It runs from a single 100-240V AC\/DC-rated supply on an IEC C14 inlet and integrates a redundancy manager for ring topologies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5534-5TR00-3AR3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622989586\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR502\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType Designation\u003c\/td\u003e\n\u003ctd\u003eXR502-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Config\u003c\/td\u003e\n\u003ctd\u003eSingle, IEC C14, 100-240V AC or 100-250V DC rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 1 HU, metal enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e446 x 43.6 x 374.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e8.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eFanless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation, horizontal)\u003c\/td\u003e\n\u003ctd\u003e-25 ... +55 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude (max)\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (max, at 25 C)\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombo RJ45 Ports (1G\/2.5G\/5G\/10G)\u003c\/td\u003e\n\u003ctd\u003e2, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP Ports (100\/1000 Mbit\/s)\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP+ Ports (1000\/10000 Mbit\/s)\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator Console\u003c\/td\u003e\n\u003ctd\u003e1x USB 2.0 Type B (USB-to-serial adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling Contact\u003c\/td\u003e\n\u003ctd\u003e1x 2-pole terminal block, 24V DC, 0.1A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply - AC Rating\u003c\/td\u003e\n\u003ctd\u003e100-240V AC, range 85-264V, IEC plug C14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply - DC Rating\u003c\/td\u003e\n\u003ctd\u003e100-250V DC, range 77-300V, 2-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss (rated)\u003c\/td\u003e\n\u003ctd\u003e99W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current Consumption\u003c\/td\u003e\n\u003ctd\u003e1.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Protection\u003c\/td\u003e\n\u003ctd\u003eF 4A \/ 250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eCLP included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eB, network load class III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Telegram Length\u003c\/td\u003e\n\u003ctd\u003e9194 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLANs\u003c\/td\u003e\n\u003ctd\u003e257 (257 at ring redundancy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Learnable MAC Addresses\u003c\/td\u003e\n\u003ctd\u003e16382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQoS Queues per Port\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Protocols\u003c\/td\u003e\n\u003ctd\u003eMRP with redundancy manager, MRP-I, PROFINET system redundancy, HRP, HSR, PRP, STP, RSTP, RSTP+, MSTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRouting Protocols\u003c\/td\u003e\n\u003ctd\u003eStatic and dynamic IP routing, RIPv2, OSPFv2, VRRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Protocols\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, Telnet, TFTP, FTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP snooping\/querier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 3AR3 variant takes a single AC mains feed on an IEC C14 inlet (the same terminal also accepts 100-250V DC) - the option to pick when the panel has mains AC available. Pick the 2AR3 sibling instead for a 24V DC bus. With 24 SFP slots and only 2 RJ45 uplink ports, the XR502-32 is built for fiber-heavy access layers rather than copper-dense ones - use the XR526-8 or XR522-12 instead where most drops are RJ45.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eThe 24x SFP port count fits distribution cabinets aggregating long-haul fiber runs from multiple remote panels or rings, with the 8x SFP+ ports carrying the 10 Gbit\/s uplink back to the plant core.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959429456155,"sku":"6GK5534-5TR00-3AR3","price":5927.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5534-5tr00-3ar3-scalance-xr502-32-industrial-ethernet-switch.png?v=1789825332"},{"product_id":"siemens-6gk5534-5tr00-4ar3-scalance-xr502-32-switch","title":"Siemens 6GK5534-5TR00-4AR3 SCALANCE XR502-32 34-Port Managed Layer 3 Industrial Ethernet Switch","description":"\u003cp\u003eThe Siemens SCALANCE XR502-32 (6GK5534-5TR00-4AR3) is a managed Layer 3 industrial Ethernet switch for 19-inch rack mounting, combining 2 electrical 10G RJ45 ports, 24 SFP ports, and 8 SFP+ ports in one chassis. It supports PROFINET IO device operation, an integrated redundancy manager, and dual 100-250 V DC \/ 100-240 V AC power inputs for redundant supply.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5534-5TR00-4AR3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR502\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047622989593\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXR502-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100, 1000 Mbit\/s electrical; 2.5, 5, 10 Gbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRJ45 Ports (1G\/2.5G\/5G\/10G)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSFP Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24, 100\/1000 Mbit\/s usable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSFP+ Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8, 1000\/10000 Mbit\/s usable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsole Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, USB 2.0 Type B (USB-to-serial adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignaling Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC \/ 0.1 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage 1 (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-250 V DC, range 77-300 V, 99 W, 1.2 A max., 2-pole terminal block, fuse F4A\/250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage 2 (AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-240 V AC (240 V rated), range 85-264 V, 99 W, 1.2 A max., IEC C14, fuse F4A\/250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundant Power Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, dual independent feeds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 ... +55 °C, horizontal mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Altitude, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% at 25 °C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e446 mm x 43.6 mm x 374.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. VLANs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Learnable MAC Addresses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Ethernet Telegram Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9194 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Conformity Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB, network load class III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSTP, RSTP, RSTP+, MSTP, MRP with redundancy manager, MRP-I, HRP with redundancy manager and standby, HSR, PRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRouting Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStatic and dynamic IP routing, RIPv2, OSPFv2, VRRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, MIB, Telnet, TFTP, FTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP snooping\/querier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePort diagnostics, packet size\/type statistics, error statistics, SysLog, I\u0026amp;M0\/I\u0026amp;M1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe XR502-32's dual AC\/DC power inputs, each independently fused, let it run from a DC UPS plus an AC mains feed at the same time, so a single supply failure does not interrupt switching. With 24 SFP and 8 SFP+ ports against only 2 electrical uplinks, it is built for a fiber-heavy backbone or aggregation layer rather than a copper access switch — pick it where most connected devices already terminate on fiber media modules. The integrated redundancy manager plus support for HRP, MRP, HSR and PRP in one unit covers both classic Siemens ring topologies and zero-recovery-time schemes without an external RM module. Static and dynamic IP routing (RIPv2, OSPFv2, VRRP) lets it segment Layer 3 subnets at the aggregation point instead of hauling all traffic to a central router.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003e19-inch rack backbone or aggregation switch for large PROFINET\/Ethernet installations needing Layer 3 routing between VLANs, dual power redundancy, and ring or PRP network redundancy — for example a plant-wide backbone linking multiple production cells.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959429816603,"sku":"6GK5534-5TR00-4AR3","price":6048.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5534-5tr00-4ar3-scalance-xr502-32-switch.png?v=1789825338"},{"product_id":"siemens-6gk5108-2qs00-3ar3","title":"Siemens 6GK5108-2QS00-3AR3 SCALANCE XR108-2PoE WG 19-Inch 8-Port PoE 2x10GE SFP+ Switch","description":"\u003cp\u003eThe Siemens SCALANCE XR108-2PoE WG 6GK5108-2QS00-3AR3 is an unmanaged 19-inch rack switch with 8x Gigabit RJ45 PoE ports and 2x SFP+ ports for 1 or 10 Gbit\/s uplinks. PoE output reaches 60 W per port and 200 W total under a single 240 V AC supply (85-264 V range). At 1U height and IP30, it's built for enclosed rack rooms rather than field cabinets.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5108-2QS00-3AR3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622727409\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eXR108-2PoE WG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Ports\u003c\/td\u003e\n\u003ctd\u003e8x RJ45, 10\/100\/1000 Mbit\/s, PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUplink Ports\u003c\/td\u003e\n\u003ctd\u003e2x SFP+, 10 Gbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE\u003c\/td\u003e\n\u003ctd\u003e8 ports, 60 W per port max, 200 W total max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Input\u003c\/td\u003e\n\u003ctd\u003e1, IEC C14 plug, redundant capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e240 V AC, range 85-264 V, 4 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Fuse Protection\u003c\/td\u003e\n\u003ctd\u003e4 A \/ 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 ... +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 ... +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eMetal, 19-inch rack, 1 height unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e482.6 x 43.6 x 133 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e2.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformance Class\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Redundancy Protocol (PRP)\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e47 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the rack-mount, PoE, 10 Gbit\/s-uplink member of the SCALANCE X108 family, built for server-room or comms-closet installs where a 19-inch frame and 240 V AC mains are standard, unlike the DIN-rail XCM108PoE variants that run on 24\/54 V DC. The 200 W total PoE budget across 8 ports, versus 120 W on the DIN-rail siblings, suits denser PoE loads such as multiple PTZ cameras or wireless access points on one switch. Choose the 24 V DC rack switch instead if the installation only needs plain uplink ports without PoE and runs on a DC cabinet bus.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959765000475,"sku":"6GK5108-2QS00-3AR3","price":1499.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5108-2qs00-3ar3-scalance-xr108-2poe-rack-switch.png?v=1789824597"},{"product_id":"siemens-6gk5124-0ba00-2ar3","title":"Siemens 6GK5124-0BA00-2AR3 SCALANCE XR124WG 19-Inch 24-Port 24V DC Ethernet Switch","description":"\u003cp\u003eThe Siemens SCALANCE XR124WG 6GK5124-0BA00-2AR3 is an unmanaged 19-inch rack switch with 24x 10\/100 Mbit\/s RJ45 ports, powered from a redundant 24 V DC input over a 19.2-28.8 V range. At 1U height with a metal enclosure and IP30, it's built for a comms rack or control room rather than a DIN-rail field cabinet.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5124-0BA00-2AR3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622504734\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eXR124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e24x RJ45, 10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Input\u003c\/td\u003e\n\u003ctd\u003e1, redundant capable, 2-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC, range 19.2-28.8 V, 0.25 A max, 6 W power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Fuse Protection\u003c\/td\u003e\n\u003ctd\u003e5 A \/ min. 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 ... +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 ... +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003e19-inch rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e482.6 x 43.6 x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e2.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Redundancy Protocol (PRP)\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003cli\u003eCCC-Ex\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eChoose this 24 V DC rack switch over the 240 V AC XR124WG sibling when the rack already runs on a DC cabinet bus, common in telecom and outstation racks alongside DC-fed PLCs. It draws only 0.25 A at 24 V, a fraction of the AC variant's current draw, and weighs 0.6 kg less since it skips the internal AC power supply. Pick the DIN-rail XC124 instead if the installation doesn't have a 19-inch frame.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959765262619,"sku":"6GK5124-0BA00-2AR3","price":726.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5124-0ba00-2ar3-scalance-xr124wg-dc-switch.png?v=1789824631"},{"product_id":"siemens-6gk5124-0ba00-3ar3","title":"Siemens 6GK5124-0BA00-3AR3 SCALANCE XR124WG 19-Inch 24-Port 230V AC Ethernet Switch","description":"\u003cp\u003eThe Siemens SCALANCE XR124WG 6GK5124-0BA00-3AR3 is an unmanaged 19-inch rack switch with 24x 10\/100 Mbit\/s RJ45 ports, powered from a redundant 240 V AC input over an 85-264 V range. At 1U height with a metal enclosure and IP30, it suits server rooms and comms racks running standard mains power rather than a DC cabinet bus.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5124-0BA00-3AR3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622485392\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eXR124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e24x RJ45, 10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Input\u003c\/td\u003e\n\u003ctd\u003e1, redundant capable, 2-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e240 V AC, range 85-264 V, 0.075 A max, 7.5 W power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Fuse Protection\u003c\/td\u003e\n\u003ctd\u003e4 A \/ 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 ... +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 ... +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003e19-inch rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e482.6 x 43.6 x 177 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e3.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Redundancy Protocol (PRP)\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis 240 V AC variant plugs straight into standard mains in a server room or comms rack, unlike the 24 V DC XR124WG sibling that needs a cabinet DC bus already in place. The internal AC power supply adds 0.6 kg and 50 mm of depth over the DC version, so confirm rack clearance before ordering. No ATEX, UKEX, or IECEx hazardous-location approvals are listed for this AC variant, so pick the DC XR124WG or the DIN-rail XC124 for Ex-rated cabinets.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959765524763,"sku":"6GK5124-0BA00-3AR3","price":850.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5124-0ba00-3ar3-scalance-xr124wg-ac-switch.png?v=1789824638"},{"product_id":"siemens-6gk5204-2aa00-2bd2-scalance-xf204-2ba-irt-switch","title":"Siemens 6GK5204-2AA00-2BD2 SCALANCE XF204-2BA IRT 4-Port Managed PROFINET Industrial Ethernet Switch","description":"\u003cp\u003eThe Siemens SCALANCE 6GK5204-2AA00-2BD2 (XF204-2BA IRT) is a managed PROFINET IRT switch with four 10\/100 Mbit\/s ports and two bus adapter interfaces for fiber or copper media modules. It runs PROFINET conformity class C with network load class II and integrates a redundancy manager for MRP, HRP and PRP ring topologies, powered from a redundant 24 V DC supply.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order Number\u003c\/td\u003e\n\u003ctd\u003e6GK5204-2AA00-2BD2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XF204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eXF204-2BA IRT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e4x 10\/100 Mbit\/s + 2x bus adapter interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Rate\u003c\/td\u003e\n\u003ctd\u003e10, 100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling Contact\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC, 0.1 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eRedundant 24 V DC, 2-pole terminal block, 19.2-28.8 V range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e2.4 W rated, 0.1 A max current draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Fuse\u003c\/td\u003e\n\u003ctd\u003e2.5 A, not user-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eMax 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e100 x 117 x 74 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm top hat DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eC-PLUG, optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Load Class\u003c\/td\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, MRPD, HRP, PRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManaged Protocols\u003c\/td\u003e\n\u003ctd\u003eSNMP v1\/v2\/v3, Telnet, TFTP, FTP, DCP, LLDP, SSH, SNTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622474112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 6GK5204-2AA00-2BD2 is Siemens' compact 4-port PROFINET IRT switch for machine-level segments where isochronous real-time traffic needs conformity class C support - choose it over a standard RT switch (conformity class B) when the automation cell runs cyclic PROFINET IRT with a fixed communication cycle. The two bus adapter interfaces let the port media, copper or fiber, be selected per interface module instead of being fixed at the switch level, useful when mixing a fiber backbone with copper drops on the same unit. Redundant 24 V DC inputs and the integrated redundancy manager (MRP, HRP, PRP) support a fail-safe ring topology without an external controller.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMachine-level PROFINET IRT segments in motion-control cells, packaging lines and robotics cabinets where a compact 4-port switch with ring redundancy sits close to the drives.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959766114587,"sku":"6GK5204-2AA00-2BD2","price":1500.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5204-2aa00-2bd2-xf204-2ba-irt-switch.png?v=1789824644"},{"product_id":"siemens-6gk5205-3bb00-2ab2-scalance-xb205-3-st","title":"Siemens 6GK5205-3BB00-2AB2 SCALANCE XB205-3 5x RJ45 3x ST Fiber Managed Ethernet Switch","description":"\u003cp\u003eThe Siemens 6GK5205-3BB00-2AB2 SCALANCE XB205-3 is a managed Layer 2 Industrial Ethernet switch with five 10\/100 Mbit\/s RJ45 ports and three 100 Mbit\/s multimode fiber ports on ST (BFOC) connectors, certified to IEC 62443-4-2. It supports MRP and HRP ring redundancy, PROFINET conformity class B, and is rated for 0 ... +60 °C operation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5205-3BB00-2AB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622178386\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XB205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eXB205-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer rate\u003c\/td\u003e\n\u003ctd\u003e10, 100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 ports\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber ports\u003c\/td\u003e\n\u003ctd\u003e3x 100 Mbit\/s ST (BFOC), multimode (100BaseFX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (19.2 ... 28.8 V), redundant supply input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, rated\u003c\/td\u003e\n\u003ctd\u003e7.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. current consumption\u003c\/td\u003e\n\u003ctd\u003e0.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower connector\u003c\/td\u003e\n\u003ctd\u003e6-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eRJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement functions\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, SNMP v1\/v2\/v3, Telnet, SSH, SSL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, HRP, RSTP, RSTP+, STP, PRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. VLANs\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET conformity class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork load class\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e80 x 117 x 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, operation\u003c\/td\u003e\n\u003ctd\u003e0 ... +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e55 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eIEC 62443-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the ST-port 3BB00 variant over the SC-port 3BD00 sibling to match existing ST (BFOC) fiber terminations already installed in the plant — the electrical specification and management feature set are otherwise identical. Being managed, this switch adds MRP\/HRP ring redundancy, VLANs, and PROFINET IO diagnostics that the unmanaged XB004 series lacks, which matters where a ring topology needs sub-300 ms reconfiguration or where SNMP-based network monitoring is required.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eBackbone or ring-topology switching for PROFINET machine networks needing redundancy, VLAN segmentation, and remote diagnostics, with multimode ST fiber uplinks between panels or cells.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959766376731,"sku":"6GK5205-3BB00-2AB2","price":1016.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5205-3bb00-2ab2-scalance-xb205-3-st-switch.png?v=1789681230"},{"product_id":"siemens-6gk5205-3bd00-2ab2-scalance-xb205-3-sc","title":"Siemens 6GK5205-3BD00-2AB2 SCALANCE XB205-3 5x RJ45 3x SC Fiber Managed Ethernet Switch","description":"\u003cp\u003eThe Siemens 6GK5205-3BD00-2AB2 SCALANCE XB205-3 is a managed Layer 2 Industrial Ethernet switch with five 10\/100 Mbit\/s RJ45 ports and three 100 Mbit\/s multimode fiber ports on SC connectors, certified to IEC 62443-4-2. It supports MRP and HRP ring redundancy, PROFINET conformity class B, and is rated for 0 ... +60 °C operation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5205-3BD00-2AB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622178331\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XB205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eXB205-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer rate\u003c\/td\u003e\n\u003ctd\u003e10, 100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 ports\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber ports\u003c\/td\u003e\n\u003ctd\u003e3x 100 Mbit\/s SC, multimode (100BaseFX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (19.2 ... 28.8 V), redundant supply input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, rated\u003c\/td\u003e\n\u003ctd\u003e7.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. current consumption\u003c\/td\u003e\n\u003ctd\u003e0.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower connector\u003c\/td\u003e\n\u003ctd\u003e6-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eRJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement functions\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, SNMP v1\/v2\/v3, Telnet, SSH, SSL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, HRP, RSTP, RSTP+, STP, PRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. VLANs\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET conformity class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork load class\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e80 x 117 x 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, operation\u003c\/td\u003e\n\u003ctd\u003e0 ... +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e55 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eIEC 62443-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the SC-port 3BD00 variant over the ST-port 3BB00 sibling to match SC fiber terminations already installed in the plant — the electrical specification and management feature set are otherwise identical. Being managed, this switch adds MRP\/HRP ring redundancy, VLANs, and PROFINET IO diagnostics that the unmanaged XB004 series lacks, which matters where a ring topology needs sub-300 ms reconfiguration or where SNMP-based network monitoring is required.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eBackbone or ring-topology switching for PROFINET machine networks needing redundancy, VLAN segmentation, and remote diagnostics, with multimode SC fiber uplinks between panels or cells.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959766671643,"sku":"6GK5205-3BD00-2AB2","price":1016.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5205-3bd00-2ab2-scalance-xb205-3-sc-switch.png?v=1789681236"},{"product_id":"siemens-6gk5205-3bf00-2ab2-scalance-xb205-3ld-switch","title":"Siemens 6GK5205-3BF00-2AB2 SCALANCE XB205-3LD 5-Port Managed Layer 2 Fiber Ethernet Switch","description":"\u003cp\u003eThe Siemens SCALANCE 6GK5205-3BF00-2AB2 (XB205-3LD) is a managed Layer 2 PROFINET switch with five 10\/100 Mbit\/s RJ45 ports and three single-mode SC fiber ports (100BaseLX LD), certified to IEC 62443-4-2 for industrial cybersecurity. It runs on a redundant 24 V DC supply and supports PROFINET conformity class B with network load class III.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order Number\u003c\/td\u003e\n\u003ctd\u003e6GK5205-3BF00-2AB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XB205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eXB205-3LD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e5x 10\/100 Mbit\/s RJ45 + 3x single-mode SC fiber (100BaseLX LD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole Port\u003c\/td\u003e\n\u003ctd\u003e1x RJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eRedundant 24 V DC, 6-pole terminal block, 19.2-28.8 V range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e7 W rated, 0.29 A max current draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eMax 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate PC-GF10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e80 x 117 x 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm top hat DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Load Class\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLANs\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, HRP, PRP, STP, RSTP, RSTP+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManaged Protocols\u003c\/td\u003e\n\u003ctd\u003eSNMP v1\/v2\/v3, Telnet, TFTP, SFTP, BOOTP, DCP, LLDP, EtherNet\/IP, IGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x\/RADIUS, SSH, SSL, IEC 62443-4-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e50 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622178355\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 6GK5205-3BF00-2AB2 pairs its RJ45 edge ports with single-mode SC fiber uplinks, so it fits segments that need to bridge a longer fiber backbone run into a copper device group without an extra media converter. Its IEC 62443-4-2 certification and RADIUS\/802.1x support make it a candidate over an uncertified switch where network access control is part of the security concept. PROFINET conformity class B with network load class III positions it for standard cyclic traffic rather than the tighter isochronous timing of a class C switch, and the 257-VLAN ceiling covers most plant segmentation schemes without needing a chassis-class switch.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eControl-room to field-level fiber backbones, machine networks bridging single-mode fiber runs to RJ45 device groups, and PROFINET segments where IEC 62443-4-2 network access control is required.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959767064859,"sku":"6GK5205-3BF00-2AB2","price":1391.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5205-3bf00-2ab2-xb205-3ld-switch.png?v=1789824650"},{"product_id":"siemens-6gk5206-2bb00-2ac2-scalance-xc206-2-switch","title":"Siemens 6GK5206-2BB00-2AC2 SCALANCE XC206-2 6xRJ45 2xBFOC Managed Industrial Ethernet Switch","description":"\u003cp\u003eThe Siemens 6GK5206-2BB00-2AC2 SCALANCE XC206-2 is a managed Layer 2 industrial Ethernet switch with six 10\/100 Mbit\/s RJ45 ports and two 100 Mbit\/s BFOC multimode fiber ports, rated for -40...+70 °C operation at IP20 with redundant 24 V DC power inputs. It supports RSTP\/MRP\/HRP ring redundancy, PRP, VLANs, and PROFINET IO diagnostics at conformity class B.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5206-2BB00-2AC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XC206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047622314760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXC206-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, 100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRJ45 Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Ports (BFOC, Multimode)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Transmission\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100BaseFX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsole Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, RJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC, range 9.6 ... 31.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundant Power Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, 4-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 A \/ 125 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignaling Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC \/ 0.1 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\/Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% at 25 °C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 mm x 147 mm x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate (PC-GF10) \/ die-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail, wall, S7-300 rail, S7-1500 rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. VLANs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Conformity Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRSTP, RSTP+, MSTP, STP, MRP, HRP, PRP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTelnet, TFTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x (RADIUS), RADIUS client, SSH, SSL, broadcast\/multicast\/unicast limiter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULHazLoc\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eIEC 62443-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe XC206-2 adds managed Layer 2 functionality - RSTP\/MRP\/HRP ring redundancy, PRP, VLANs, and PROFINET IO diagnostics - on top of a 6-port RJ45 plus 2-port BFOC multimode fiber layout, so choose it when the segment needs ring topology, redundancy protocols, or SNMP-based diagnostics rather than a plain unmanaged link. It is IEC 62443-4-2 certified, relevant where the network falls under an IEC 62443 component security requirement, and the C-PLUG slot allows swapping a failed switch without reconfiguring it in the field.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eManaged Layer 2 switch for PROFINET and EtherNet\/IP automation networks that need ring redundancy (MRP\/HRP\/RSTP), VLAN segmentation, or centralized diagnostics - for example a plant backbone or machine network under an IEC 62443 security scope.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959767359771,"sku":"6GK5206-2BB00-2AC2","price":1306.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5206-2bb00-2ac2-scalance-xc206-2-switch.png?v=1789715053"},{"product_id":"siemens-6gk5206-2bd00-2ac2-scalance-xc206-2-sc","title":"Siemens 6GK5206-2BD00-2AC2 SCALANCE XC206-2 6x RJ45 2x SC Fiber Managed Ethernet Switch","description":"\u003cp\u003eThe Siemens 6GK5206-2BD00-2AC2 SCALANCE XC206-2 is a managed Layer 2 Industrial Ethernet switch with six 10\/100 Mbit\/s RJ45 ports and two 100 Mbit\/s multimode fiber ports on SC connectors, rated for -40 ... +70 °C operation and a C-PLUG slot for configuration transfer. It runs as a PROFINET IO device with MRP\/HRP ring redundancy and DHCP server functions.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5206-2BD00-2AC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622314807\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XC206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eXC206-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer rate\u003c\/td\u003e\n\u003ctd\u003e10, 100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 ports\u003c\/td\u003e\n\u003ctd\u003e6, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber ports\u003c\/td\u003e\n\u003ctd\u003e2x 100 Mbit\/s SC, multimode (100BaseFX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (9.6 ... 31.2 V), redundant supply input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, rated\u003c\/td\u003e\n\u003ctd\u003e6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. current consumption\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower connector\u003c\/td\u003e\n\u003ctd\u003e4-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling contact\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC \/ 0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eRJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable storage\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement functions\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, SNMP v1\/v2\/v3, Telnet, SSH, SSL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, HRP, RSTP, RSTP+, MSTP, STP, PRP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. VLANs\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET conformity class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail, S7-300\/S7-1500 rail, or wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e60 x 147 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, operation\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eIEC 62443-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe XC206-2's -40 ... +70 °C rating and die-cast aluminum\/PC-GF10 enclosure set it apart from the indoor-only XB205 series — specify it for outdoor cabinets, unheated switch rooms, or machinery exposed to temperature extremes. Choose the SC-port 2BD00 variant to match existing SC multimode fiber; the 2BS00 SFP variant instead accepts pluggable optics for mixed fiber types or gigabit uplinks. The C-PLUG slot lets a replacement unit take over the saved configuration without a PC, which matters for fast field swaps on machines with limited downtime tolerance.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eExtended-temperature PROFINET switching in outdoor enclosures, unheated switch cabinets, and machine-mounted panels needing ring redundancy and multimode SC fiber uplinks.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959767916827,"sku":"6GK5206-2BD00-2AC2","price":1306.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5206-2bd00-2ac2-scalance-xc206-2-sc-switch.png?v=1789681243"},{"product_id":"siemens-6gk5206-2bs00-2ac2-scalance-xc206-2sfp","title":"Siemens 6GK5206-2BS00-2AC2 SCALANCE XC206-2SFP 6x RJ45 2x SFP Managed Ethernet Switch","description":"\u003cp\u003eThe Siemens 6GK5206-2BS00-2AC2 SCALANCE XC206-2SFP is a managed Layer 2 Industrial Ethernet switch with six 10\/100 Mbit\/s RJ45 ports and two pluggable SFP slots supporting up to 1000 Mbit\/s, rated for -40 ... +70 °C operation. The SFP slots let the same base unit take multimode, single-mode, or copper transceivers depending on the uplink.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5206-2BS00-2AC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622314852\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XC206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eXC206-2SFP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer rate\u003c\/td\u003e\n\u003ctd\u003e10, 100, 1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 ports\u003c\/td\u003e\n\u003ctd\u003e6, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP slots\u003c\/td\u003e\n\u003ctd\u003e2, pluggable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (9.6 ... 31.2 V), redundant supply input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, rated\u003c\/td\u003e\n\u003ctd\u003e6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. current consumption\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower connector\u003c\/td\u003e\n\u003ctd\u003e4-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling contact\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC \/ 0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eRJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable storage\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement functions\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, SNMP v1\/v2\/v3, Telnet, SSH, SSL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, HRP, RSTP, RSTP+, MSTP, STP, PRP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. VLANs\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET conformity class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail, S7-300\/S7-1500 rail, or wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e60 x 147 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, operation\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eIEC 62443-4-2\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eChoose the 2BS00 SFP variant over the fixed-SC 2BD00 model when the uplink medium is not yet fixed or when a gigabit link is needed — the SFP cage takes any compatible Siemens transceiver, so the same switch part number covers multimode, single-mode, and copper uplinks by swapping the module instead of the switch. The -40 ... +70 °C rating and C-PLUG configuration slot carry over from the XC206-2, so it fits the same outdoor-cabinet and fast-swap use cases.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eExtended-temperature PROFINET switching where uplink media may change over the machine's life or where a gigabit backbone link is required, using pluggable SFP transceivers.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959768178971,"sku":"6GK5206-2BS00-2AC2","price":1016.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5206-2bs00-2ac2-scalance-xc206-2sfp-switch.png?v=1789681249"},{"product_id":"siemens-6gk5206-2gs00-2ac2-scalance-xc206-2sfp-g-switch","title":"Siemens 6GK5206-2GS00-2AC2 SCALANCE XC206-2SFP G 6-Port Gigabit Managed Layer 2 Ethernet Switch","description":"\u003cp\u003eThe Siemens SCALANCE 6GK5206-2GS00-2AC2 (XC206-2SFP G) is a managed Gigabit Layer 2 PROFINET switch with six 10\/100\/1000 Mbit\/s RJ45 ports and two 1000 Mbit\/s SFP slots, certified to IEC 62443-4-2. It supports PROFINET conformity class B with network load class III, IEEE 1588v2 PTP time sync, and mounts on DIN rail, S7-300\/S7-1500 rail, or wall from a redundant 24 V DC supply.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order Number\u003c\/td\u003e\n\u003ctd\u003e6GK5206-2GS00-2AC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XC206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eXC206-2SFP G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e6x 10\/100\/1000 Mbit\/s RJ45 + 2x SFP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole Port\u003c\/td\u003e\n\u003ctd\u003e1x RJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eRedundant 24 V DC, 4-pole terminal block, 9.6-31.2 V range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e6 W rated, 0.5 A max current draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Fuse\u003c\/td\u003e\n\u003ctd\u003e2.5 A \/ 125 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eMax 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate PC-GF10 \/ die-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e60 x 147 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail, S7-300\/S7-1500 rail, wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Load Class\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Telegram Length\u003c\/td\u003e\n\u003ctd\u003e10240 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLANs\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, H-Sync, PROFINET system redundancy, HRP, STP, RSTP, RSTP+, MSTP, PRP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManaged Protocols\u003c\/td\u003e\n\u003ctd\u003eSNMP v1\/v2\/v3, Telnet, TFTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, IGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x\/RADIUS, broadcast limiter, SSH, SSL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Sync\u003c\/td\u003e\n\u003ctd\u003eSICLOCK, NTP, SNTP, IEEE 1588v2 PTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622614273\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 6GK5206-2GS00-2AC2 steps up to full Gigabit on all six RJ45 ports plus two SFP slots, so pick it over a Fast Ethernet switch when the cell needs camera or high-rate diagnostic traffic rather than basic I\/O. IEEE 1588v2 PTP support distinguishes it from switches without hardware time sync, relevant when downstream drives or measurement devices need a common clock. The redundancy set (MRP, HRP, PRP, MSTP, LACP) and S7-300\/S7-1500 rail mounting make it a direct fit for a machine control cabinet already built around those rail profiles, without needing a separate mounting adapter.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eGigabit backbone segments inside a machine cabinet, camera and vision-system networks, and PROFINET cells needing PTP time synchronization between drives and controllers.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959769620763,"sku":"6GK5206-2GS00-2AC2","price":1126.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5206-2gs00-2ac2-xc206-2sfp-g-switch.png?v=1789824657"},{"product_id":"siemens-6gk5206-2rs00-2ac2-scalance-xc206-2g-poe-switch","title":"Siemens 6GK5206-2RS00-2AC2 SCALANCE XC206-2G PoE 6-Port Gigabit 120W PoE Managed Switch","description":"\u003cp\u003eThe Siemens SCALANCE 6GK5206-2RS00-2AC2 (XC206-2G PoE) is a managed Gigabit PROFINET switch with six 10\/100\/1000 Mbit\/s RJ45 PoE ports (four IEEE 802.3at 30 W, two 802.3bt 60 W) and two 10 Gbit\/s SFP+ slots. It delivers up to 120 W of PoE power distributed across all ports from a redundant 24 V DC supply, and is certified to IEC 62443-4-2.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order Number\u003c\/td\u003e\n\u003ctd\u003e6GK5206-2RS00-2AC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XC206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eXC206-2G PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e6x 10\/100\/1000 Mbit\/s RJ45 PoE (4x IEEE 802.3at 30 W, 2x IEEE 802.3bt 60 W) + 2x SFP+ (1000\/10000 Mbit\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole Port\u003c\/td\u003e\n\u003ctd\u003e1x RJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Power Budget\u003c\/td\u003e\n\u003ctd\u003e120 W distributed across all PoE ports, 144 W total PSE maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eRedundant 24 V DC infeed, 4-pole terminal block, 19.2-31.2 V range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e18 W rated, 6 A max current draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A \/ 125 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eMax 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate PC-GF10 \/ die-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e100 x 147 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.955 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail, S7-300\/S7-1500 rail, wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Load Class\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Telegram Length\u003c\/td\u003e\n\u003ctd\u003e10240 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLANs\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, H-Sync, PROFINET system redundancy, HRP, STP, RSTP, RSTP+, MSTP, PRP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManaged Protocols\u003c\/td\u003e\n\u003ctd\u003eSNMP v1\/v2\/v3, Telnet, TFTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, IGMP, DHCP server\/client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x\/RADIUS, broadcast limiter, SSH, SSL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Sync\u003c\/td\u003e\n\u003ctd\u003eSICLOCK, NTP, SNTP, IEEE 1588v2 PTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622706237\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eEN 50121-4\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 6GK5206-2RS00-2AC2 runs its PoE budget from a 24 V DC infeed and delivers 120 W across all six PoE ports, so it fits a cell already standardized on 24 V control power where the switch feeds cameras or wireless access points alongside the DIN-rail controller. Two 802.3bt ports at 60 W each cover high-draw PTZ cameras or PoE lighting that a 802.3at-only switch cannot power. Choose the 54 V variant instead when the plant runs a 54 V infeed or when the combined PoE draw needs the larger 240 W budget that voltage enables; both share the same port count, SFP+ uplinks and PROFINET conformity class B.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMachine-vision camera rings, PoE-powered access points, and mixed Gigabit\/PoE device groups on a 24 V DC control cabinet supply.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959771488539,"sku":"6GK5206-2RS00-2AC2","price":2117.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5206-2rs00-2ac2-xc206-2g-poe-switch.png?v=1789824663"},{"product_id":"siemens-6gk5206-2rs00-5ac2-scalance-xc206-2g-poe-54v-switch","title":"Siemens 6GK5206-2RS00-5AC2 SCALANCE XC206-2G PoE (DC 54V) 6-Port Gigabit 240W Managed Switch","description":"\u003cp\u003eThe Siemens SCALANCE 6GK5206-2RS00-5AC2 (XC206-2G PoE, DC 54 V) is a managed Gigabit PROFINET switch with six 10\/100\/1000 Mbit\/s RJ45 PoE ports (four IEEE 802.3at, two 802.3bt) and two 10 Gbit\/s SFP+ slots. Its 54 V DC infeed raises the total PoE budget to 240 W across all ports, versus 120 W on the 24 V version, and it is certified to IEC 62443-4-2.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order Number\u003c\/td\u003e\n\u003ctd\u003e6GK5206-2RS00-5AC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XC206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eXC206-2G PoE (DC 54 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e6x 10\/100\/1000 Mbit\/s RJ45 PoE (4x IEEE 802.3at, 2x IEEE 802.3bt) + 2x SFP+ (1000\/10000 Mbit\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole Port\u003c\/td\u003e\n\u003ctd\u003e1x RJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Power Budget\u003c\/td\u003e\n\u003ctd\u003e240 W distributed across all PoE ports, 260 W total PSE maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eRedundant 54 V DC infeed, 4-pole terminal block, 52-57 V range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e10 W rated, 5 A max current draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A \/ 125 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eMax 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate PC-GF10 \/ die-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e60 x 147 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail, S7-300\/S7-1500 rail, wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Load Class\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Telegram Length\u003c\/td\u003e\n\u003ctd\u003e10240 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLANs\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, H-Sync, PROFINET system redundancy, HRP, STP, RSTP, RSTP+, MSTP, PRP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManaged Protocols\u003c\/td\u003e\n\u003ctd\u003eSNMP v1\/v2\/v3, Telnet, TFTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, IGMP, DHCP server\/client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x\/RADIUS, broadcast limiter, SSH, SSL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Sync\u003c\/td\u003e\n\u003ctd\u003eSICLOCK, NTP, SNTP, IEEE 1588v2 PTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622840382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 6GK5206-2RS00-5AC2 is the 54 V infeed sibling of the XC206-2G PoE family: choose it when the plant standardizes on a 54 V DC bus, since the extra headroom raises the switchable PoE budget to 240 W against 120 W on the 24 V unit. Port count, SFP+ uplinks, PROFINET conformity class B and the redundancy protocol set are unchanged from the 24 V version, so the decision comes down to available supply voltage and PoE load, not switching performance.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003ePoE camera and access-point networks on plants running a 54 V DC control bus where the higher per-port PoE budget is needed.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959771554075,"sku":"6GK5206-2RS00-5AC2","price":1755.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5206-2rs00-5ac2-xc206-2g-poe-54v-switch.png?v=1789825188"},{"product_id":"siemens-6gk5206-2rs00-5fc2-scalance-xc206-2g-poe-eec-switch","title":"Siemens 6GK5206-2RS00-5FC2 SCALANCE XC206-2G PoE EEC 240W PoE Conformal-Coated Managed Switch","description":"\u003cp\u003eThe Siemens SCALANCE 6GK5206-2RS00-5FC2 (XC206-2G PoE EEC, DC 54 V) is a managed Gigabit PROFINET switch with six 10\/100\/1000 Mbit\/s RJ45 PoE ports and two 10 Gbit\/s SFP+ slots, built with conformal-coated boards for extended environmental duty. It shares the 240 W PoE budget of the standard 54 V unit but adds a 4000 m maximum installation altitude rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order Number\u003c\/td\u003e\n\u003ctd\u003e6GK5206-2RS00-5FC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XC206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eXC206-2G PoE EEC (DC 54 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e6x 10\/100\/1000 Mbit\/s RJ45 PoE (4x IEEE 802.3at, 2x IEEE 802.3bt) + 2x SFP+ (1000\/10000 Mbit\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole Port\u003c\/td\u003e\n\u003ctd\u003e1x RJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Power Budget\u003c\/td\u003e\n\u003ctd\u003e240 W distributed across all PoE ports, 260 W total PSE maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eRedundant 54 V DC infeed, 4-pole terminal block, 52-57 V range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e10 W rated, 5 A max current draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A \/ 125 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude\u003c\/td\u003e\n\u003ctd\u003eMax 4000 m above sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eMax 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate PC-GF10 \/ die-cast aluminum, conformal-coated boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e60 x 147 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail, S7-300\/S7-1500 rail, wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Load Class\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLANs\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, H-Sync, PROFINET system redundancy, HRP, STP, RSTP, RSTP+, MSTP, PRP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManaged Protocols\u003c\/td\u003e\n\u003ctd\u003eSNMP v1\/v2\/v3, Telnet, TFTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, IGMP, DHCP server\/client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x\/RADIUS, broadcast limiter, SSH, SSL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Sync\u003c\/td\u003e\n\u003ctd\u003eSICLOCK, NTP, SNTP, IEEE 1588v2 PTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622840399\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 6GK5206-2RS00-5FC2 adds conformal coating and a 4000 m installation altitude rating to the base XC206-2G PoE 54 V switch, so pick it when the cabinet sees condensing humidity, salt air or high-altitude installation that would shorten the life of an uncoated board. Port layout, PoE budget (240 W) and PROFINET conformity class B match the standard 54 V variant exactly, so the choice is purely about the environmental exposure of the install site, not switching capability.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003ePoE camera and access-point networks in high-altitude, humid or corrosive environments such as mining, marine and outdoor cabinets where board-level environmental protection matters.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959771816219,"sku":"6GK5206-2RS00-5FC2","price":1887.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5206-2rs00-5fc2-xc206-2g-poe-eec-switch.png?v=1789824670"},{"product_id":"siemens-6gk5208-0ba00-2ac2-scalance-xc208-switch","title":"Siemens 6GK5208-0BA00-2AC2 SCALANCE XC208 8-Port Managed Layer 2 Industrial Ethernet Switch","description":"\u003cp\u003eThe Siemens 6GK5208-0BA00-2AC2 SCALANCE XC208 is a managed Layer 2 Industrial Ethernet switch with 8x 10\/100 Mbit\/s RJ45 ports, a console port, and redundant 24 V DC power inputs, rated IP20 for -40 to +70 °C operation. It supports PROFINET IO device conformity class B, RSTP\/MRP ring redundancy, and IEC 62443-4-2 cybersecurity certification, with mounting on DIN rail, S7-300\/S7-1500 rail, or wall.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5208-0BA00-2AC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622314890\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XC208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eXC208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e8x 10\/100 Mbit\/s RJ45 (with securing collar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole Port\u003c\/td\u003e\n\u003ctd\u003e1x RJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling Contact\u003c\/td\u003e\n\u003ctd\u003e1x 2-pole terminal block, 24 V DC \/ 0.1 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n\u003ctd\u003e4-pole terminal block, redundant input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (9.6 ... 31.2 V range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss (Rated)\u003c\/td\u003e\n\u003ctd\u003e4.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current Consumption\u003c\/td\u003e\n\u003ctd\u003e0.35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Fuse Protection\u003c\/td\u003e\n\u003ctd\u003e2.5 A \/ 125 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eC-PLUG slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation)\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Storage\/Transport)\u003c\/td\u003e\n\u003ctd\u003e-40 ... +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (Max)\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e60 x 147 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate (PC-GF10) \/ pressure die-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail, wall, S7-300 rail, S7-1500 rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLANs\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Ethernet Telegram Length\u003c\/td\u003e\n\u003ctd\u003e1632 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eTelnet, TFTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP (snooping\/querier)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eMRP (with redundancy manager), MRP-I, HRP (manager and standby), STP, RSTP, RSTP+, MSTP, PRP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x (RADIUS), RADIUS client, broadcast\/multicast\/unicast limiter, SSH, SSL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Synchronization\u003c\/td\u003e\n\u003ctd\u003eSICLOCK support, NTP client, SNTP client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, MIB support, port mirroring, multiport mirroring, port diagnostics, SysLog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM registration\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe fixed 8-port RJ45 configuration and dual power inputs make the XC208 a fit for machine-level segments that need up to 8 Ethernet drops with power redundancy, not for larger cell-level backbones. PROFINET conformity class B plus MRP and HRP ring-redundancy support let it sit in a ring topology with sub-300 ms reconfiguration, and the -40 to +70 °C rating and IEC 62443-4-2 certification suit unheated cabinets in security-conscious plants. Where more than 8 ports or fiber uplinks are needed, a larger-port-count or SC-port SCALANCE variant is the better fit.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003ePROFINET machine networks needing redundant ring topology (MRP\/HRP), unheated or outdoor cabinets down to -40 °C, and DIN-rail or S7-1500 rail integration alongside SIMATIC controllers.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959772111131,"sku":"6GK5208-0BA00-2AC2","price":871.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5208-0ba00-2ac2-scalance-xc208-switch.png?v=1789680724"},{"product_id":"siemens-6gk5208-0ga00-2ac2-scalance-xc208g","title":"Siemens 6GK5208-0GA00-2AC2 SCALANCE XC208G 8x RJ45 Gigabit PTP Managed Ethernet Switch","description":"\u003cp\u003eThe Siemens 6GK5208-0GA00-2AC2 SCALANCE XC208G is a managed Layer 2 Industrial Ethernet switch with eight 10\/100\/1000 Mbit\/s RJ45 ports, IEEE 1588v2 PTP time synchronization, and a -40 ... +70 °C operating range. All eight ports run at full gigabit speed, which the smaller XC206 series does not offer on its copper ports.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5208-0GA00-2AC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622614358\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XC208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eXC208G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer rate\u003c\/td\u003e\n\u003ctd\u003e10, 100, 1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 ports\u003c\/td\u003e\n\u003ctd\u003e8, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (9.6 ... 31.2 V), redundant supply input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, rated\u003c\/td\u003e\n\u003ctd\u003e4.3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. current consumption\u003c\/td\u003e\n\u003ctd\u003e0.36 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower connector\u003c\/td\u003e\n\u003ctd\u003e4-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling contact\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC \/ 0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eRJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable storage\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime synchronization\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588 PTP (default profile)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement functions\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, SNMP v1\/v2\/v3, Telnet, SSH, SSL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, HRP, RSTP, RSTP+, MSTP, STP, PRP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. VLANs\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET conformity class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork load class\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Ethernet telegram length\u003c\/td\u003e\n\u003ctd\u003e10240 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail, S7-300\/S7-1500 rail, or wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e60 x 147 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, operation\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eIEC 62443-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eSpecify the XC208G over the XC206 series when the segment needs more than six ports or when every port must run at full gigabit speed rather than 10\/100 Mbit\/s — motion-heavy PROFINET lines and applications combining PLC, drive, and camera traffic on one switch benefit most from the extra bandwidth and the 10240-byte jumbo frame support. IEEE 1588v2 PTP support is the other differentiator: pick this switch specifically where devices downstream need a synchronized time base, such as coordinated motion or event-correlated diagnostics across multiple controllers.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eGigabit backbone switching for PROFINET cells combining PLCs, drives, and vision or camera traffic, and networks requiring IEEE 1588v2 time synchronization across controllers.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959772602651,"sku":"6GK5208-0GA00-2AC2","price":1265.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5208-0ga00-2ac2-scalance-xc208g-switch.png?v=1789681256"},{"product_id":"siemens-6gk5208-0ha00-2as6-scalance-xp208-switch","title":"Siemens 6GK5208-0HA00-2AS6 SCALANCE XP208 8-Port M12 IP65 Managed PROFINET Switch","description":"\u003cp\u003eThe Siemens SCALANCE 6GK5208-0HA00-2AS6 (XP208) is a managed PROFINET switch with eight 10\/100 Mbit\/s M12 D-coded ports in an IP65 aluminum enclosure for direct field mounting without a cabinet. It runs PROFINET conformity class B with network load class III from a redundant 24 V DC supply through M12 power connectors, and supports MRP and HRP ring redundancy.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order Number\u003c\/td\u003e\n\u003ctd\u003e6GK5208-0HA00-2AS6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XP208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eXP208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e8x 10\/100 Mbit\/s M12 D-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole Port\u003c\/td\u003e\n\u003ctd\u003e5-pole M12 socket, A-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling Contact\u003c\/td\u003e\n\u003ctd\u003e5-pole M12 plug B-coded, 24 V DC, 0.1 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eRedundant 24 V DC, 2x 4-pole M12 plug A-coded, 19.2-28.8 V range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e5 W rated, 0.21 A max current draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Fuse\u003c\/td\u003e\n\u003ctd\u003e5 A \/ 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eMax 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eAluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e200 x 200 x 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eET 200pro module carrier, wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eC-PLUG, optional, device replacement supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Load Class\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Telegram Length\u003c\/td\u003e\n\u003ctd\u003e1518 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLANs\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, H-Sync, PROFINET system redundancy, HRP, STP, RSTP, RSTP+, MSTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManaged Protocols\u003c\/td\u003e\n\u003ctd\u003eSNMP v1\/v2\/v3, Telnet, TFTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, IGMP, DHCP server\/client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x\/RADIUS, broadcast limiter\/blocking, SSH, SSL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Sync\u003c\/td\u003e\n\u003ctd\u003eSICLOCK, NTP, SNTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622394182\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 6GK5208-0HA00-2AS6 mounts M12-coded connectors on all eight data ports plus the power and console interfaces, so it fits machine-level installations outside a cabinet where the IP65 rating removes the need for an enclosure. Choose it over the DIN-rail SCALANCE switches in this batch when the install point sees washdown, dust or vibration on the machine itself rather than inside a control panel. It fits the ET 200pro module-carrier mounting rail already used for ET 200pro I\/O, keeping the network drop on the same rail as the distributed I\/O it serves.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMachine-mounted PROFINET segments in washdown, dusty or outdoor zones where IP65 M12 connectors replace a cabinet-mounted DIN-rail switch, including ET 200pro-based distributed I\/O lines.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959772864795,"sku":"6GK5208-0HA00-2AS6","price":1337.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5208-0ha00-2as6-xp208-switch.png?v=1789824677"},{"product_id":"siemens-6gk5208-0ha00-2es6-scalance-xp208eec-switch","title":"Siemens 6GK5208-0HA00-2ES6 SCALANCE XP208EEC 8-Port M12 IP65 Railway Managed Switch","description":"\u003cp\u003eThe Siemens SCALANCE 6GK5208-0HA00-2ES6 (XP208EEC) is a managed PROFINET switch with eight 10\/100 Mbit\/s M12 D-coded ports in an IP65 aluminum enclosure, approved to railway standards EN 50155 and EN 45545. Conformal-coated boards let it withstand 10 minutes at -40 to +85 degC, and it runs from a redundant 24 V DC supply with PROFINET conformity class B.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order Number\u003c\/td\u003e\n\u003ctd\u003e6GK5208-0HA00-2ES6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XP208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eXP208EEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e8x 10\/100 Mbit\/s M12 D-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole Port\u003c\/td\u003e\n\u003ctd\u003e5-pole M12 socket, A-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling Contact\u003c\/td\u003e\n\u003ctd\u003e5-pole M12 plug B-coded, 24 V DC, 0.1 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eRedundant 24 V DC, 2x 4-pole M12 plug A-coded, 19.2-28.8 V range (16.8-30 V DC for EN 50155 duty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e5 W rated, 0.21 A max current draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Fuse\u003c\/td\u003e\n\u003ctd\u003e5 A \/ 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC (10 min at -40 to +85 degC under EN 50155)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eMax 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eAluminum, conformal-coated boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e200 x 200 x 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eET 200pro module carrier, wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eC-PLUG, optional, device replacement supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Load Class\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Telegram Length\u003c\/td\u003e\n\u003ctd\u003e1518 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLANs\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, H-Sync, PROFINET system redundancy, HRP, STP, RSTP, RSTP+, MSTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManaged Protocols\u003c\/td\u003e\n\u003ctd\u003eSNMP v1\/v2\/v3, Telnet, TFTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, IGMP, DHCP server\/client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x\/RADIUS, broadcast limiter\/blocking, SSH, SSL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Sync\u003c\/td\u003e\n\u003ctd\u003eSICLOCK, NTP, SNTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622294161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eEN 50155\u003c\/li\u003e\n\u003cli\u003eEN 45545\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 6GK5208-0HA00-2ES6 is the railway-rated sibling of the XP208: pick it over the base XP208 when the installation must meet EN 50155 rolling-stock electrical duty or EN 45545 fire-behavior requirements, since conformal coating and the extended 10-minute -40 to +85 degC rating are unique to this variant. Port count, M12 connector layout, IP65 rating and PROFINET conformity class B are identical to the base unit, so outside a railway application the standard XP208 covers the same networking job at lower cost.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eTrackside and onboard PROFINET networks, transit rolling stock, and other EN 50155\/EN 45545-regulated environments needing an IP65 M12 managed switch.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959773126939,"sku":"6GK5208-0HA00-2ES6","price":1947.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5208-0ha00-2es6-xp208eec-switch.png?v=1789824684"},{"product_id":"siemens-6gk5208-0ra00-2ac2-scalance-xc208g-poe-switch","title":"Siemens 6GK5208-0RA00-2AC2 SCALANCE XC208G PoE 8-Port Gigabit 120W PoE Managed Switch","description":"\u003cp\u003eThe Siemens SCALANCE 6GK5208-0RA00-2AC2 (XC208G PoE) is a managed Gigabit PROFINET switch with eight 10\/100\/1000 Mbit\/s RJ45 ports, six of them PoE (four IEEE 802.3at 30 W, two 802.3bt 60 W). It delivers up to 120 W of PoE power across those ports from a redundant 24 V DC infeed, and is certified to IEC 62443-4-2 with PROFINET conformity class B.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order Number\u003c\/td\u003e\n\u003ctd\u003e6GK5208-0RA00-2AC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XC208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eXC208G PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e8x 10\/100\/1000 Mbit\/s RJ45 (2 non-PoE, 4x IEEE 802.3at 30 W PoE, 2x IEEE 802.3bt 60 W PoE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole Port\u003c\/td\u003e\n\u003ctd\u003e1x RJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Power Budget\u003c\/td\u003e\n\u003ctd\u003e120 W distributed across the PoE ports, 144 W total PSE maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eRedundant 24 V DC infeed, 4-pole terminal block, 19.2-31.2 V range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss \/ Current Draw\u003c\/td\u003e\n\u003ctd\u003e6 A at rated supply voltage, 7.5 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A \/ 125 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eMax 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate PC-GF10 \/ die-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e100 x 147 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.955 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail, S7-300\/S7-1500 rail, wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Load Class\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Telegram Length\u003c\/td\u003e\n\u003ctd\u003e10240 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLANs\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, H-Sync, PROFINET system redundancy, HRP, STP, RSTP, RSTP+, MSTP, PRP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManaged Protocols\u003c\/td\u003e\n\u003ctd\u003eSNMP v1\/v2\/v3, Telnet, TFTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, IGMP, DHCP server\/client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x\/RADIUS, broadcast limiter\/blocking, SSH, SSL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Sync\u003c\/td\u003e\n\u003ctd\u003eSICLOCK, NTP, SNTP, IEEE 1588v2 PTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622706275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eEN 50121-4\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 6GK5208-0RA00-2AC2 puts eight Gigabit ports in one unit, two of them plain data-only, so it fits a cell that needs both PoE cameras or access points and a couple of standard controller or PC drops without a second switch. The 24 V DC infeed matches a cabinet already standardized on 24 V control power, and the 120 W PoE budget across six ports covers a typical mix of 802.3at and 802.3bt devices. Choose the 54 V variant instead when the plant runs a 54 V bus or when the combined PoE draw needs the larger 240 W budget that voltage provides.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eEight-port Gigabit cells mixing PoE cameras or access points with standard controller and HMI drops on a 24 V DC control cabinet supply.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959773159707,"sku":"6GK5208-0RA00-2AC2","price":2238.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5208-0ra00-2ac2-xc208g-poe-switch.png?v=1789824691"},{"product_id":"siemens-6gk5208-0ra00-5ac2-scalance-xc208g-poe-54v-switch","title":"Siemens 6GK5208-0RA00-5AC2 SCALANCE XC208G PoE (DC 54V) 8-Port Gigabit 240W Managed Switch","description":"\u003cp\u003eThe Siemens SCALANCE 6GK5208-0RA00-5AC2 (XC208G PoE, DC 54 V) is a managed Gigabit PROFINET switch with eight 10\/100\/1000 Mbit\/s RJ45 ports, six of them PoE (four IEEE 802.3at, two 802.3bt). Its 54 V DC infeed raises the total PoE budget to 240 W, versus 120 W on the 24 V version, and it is certified to IEC 62443-4-2 with PROFINET conformity class B.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU \/ Order Number\u003c\/td\u003e\n\u003ctd\u003e6GK5208-0RA00-5AC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XC208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eXC208G PoE (DC 54 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorts\u003c\/td\u003e\n\u003ctd\u003e8x 10\/100\/1000 Mbit\/s RJ45 (2 non-PoE, 4x IEEE 802.3at PoE, 2x IEEE 802.3bt PoE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole Port\u003c\/td\u003e\n\u003ctd\u003e1x RJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE Power Budget\u003c\/td\u003e\n\u003ctd\u003e240 W distributed across the PoE ports, 260 W total PSE maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eRedundant 54 V DC infeed, 4-pole terminal block, 52-57 V range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss \/ Current Draw\u003c\/td\u003e\n\u003ctd\u003e5 A at rated supply voltage, 5 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Fuse\u003c\/td\u003e\n\u003ctd\u003e15 A \/ 125 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Transport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eMax 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate PC-GF10 \/ die-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e60 x 147 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail, S7-300\/S7-1500 rail, wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable Storage\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Load Class\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Telegram Length\u003c\/td\u003e\n\u003ctd\u003e10240 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLANs\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, H-Sync, PROFINET system redundancy, HRP, STP, RSTP, RSTP+, MSTP, PRP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManaged Protocols\u003c\/td\u003e\n\u003ctd\u003eSNMP v1\/v2\/v3, Telnet, TFTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, IGMP, DHCP server\/client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x\/RADIUS, broadcast limiter\/blocking, SSH, SSL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Sync\u003c\/td\u003e\n\u003ctd\u003eSICLOCK, NTP, SNTP, IEEE 1588v2 PTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622840405\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 6GK5208-0RA00-5AC2 is the 54 V infeed sibling of the XC208G PoE family: choose it when the plant runs a 54 V DC bus, since the higher infeed voltage doubles the switchable PoE budget to 240 W against 120 W on the 24 V unit. Port count (eight, six PoE), SFP-free Gigabit copper layout and PROFINET conformity class B match the 24 V version, so the decision is about available supply voltage and PoE load rather than switching capability.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eEight-port PoE camera and access-point networks on plants running a 54 V DC control bus where the higher per-port PoE budget is needed.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959773454619,"sku":"6GK5208-0RA00-5AC2","price":1875.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5208-0ra00-5ac2-xc208g-poe-54v-switch.png?v=1789825194"},{"product_id":"siemens-6gk5208-0ua00-5es6-scalance-xp208poe-eec","title":"Siemens 6GK5208-0UA00-5ES6 SCALANCE XP208PoE EEC 8-Port M12 PoE IP65 Ethernet Switch","description":"\u003cp\u003eThe Siemens 6GK5208-0UA00-5ES6 SCALANCE XP208PoE EEC is a managed industrial Ethernet switch with 8 M12-coded 10\/100 Mbit\/s ports, 4 of which supply Power over Ethernet at up to 30 W per port and 120 W total. Rated IP65 for cabinet-free mounting and -40 to +70 degC operation, it runs PROFINET IO diagnostics at conformity class B with MRP and HRP ring redundancy.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5208-0UA00-5ES6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XP208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047622294208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXP208PoE EEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, 100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM12 Ports (10\/100 Mbit\/s, D-coded)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM12 Ports with PoE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Network Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8, M12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE Power, per Port \/ Total\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 W max. \/ 120 W max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsole Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, 5-pole M12 socket (A-coded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignaling Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-pole M12 plug (B-coded), 54 V DC \/ 0.1 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (PoE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54 V DC, range 46 ... 57 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x 4-pole M12 plug (A-coded), redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A \/ 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 degC (EEC: -40 ... +85 degC for 10 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% at 25 degC, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mm x 200 mm x 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAluminum, conformal coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eET200pro module carrier, wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. VLANs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Conformity Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, HRP, RSTP, RSTP+, MSTP, STP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTelnet, TFTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x (RADIUS), RADIUS client, SSH, SSL, broadcast\/multicast\/unicast limiter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe XP208PoE EEC packs its 8 ports into M12 connectors with an IP65 housing, so it mounts directly in the field without a control cabinet, unlike the RJ45-based XC\/XB series that need IP20 enclosures. The 4 PoE-capable ports (30 W per port, 120 W total budget) let it power M12-connected cameras or WLAN access points from the switch itself, removing separate injectors. Choose the EEC variant over the standard XP208 when the installation needs the extended -40 to +85 degC 10-minute transport rating on top of the normal -40 to +70 degC operating range.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eM12 field-mounted PROFINET switching for machine-level networks and outdoor\/vibration-exposed installations that need to power PoE devices such as IP cameras or WLAN access points directly at the switch.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959773782299,"sku":"6GK5208-0UA00-5ES6","price":1493.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5208-0ua00-5es6-scalance-xp208poe-eec-switch.png?v=1789824699"},{"product_id":"siemens-6gk5213-3bb00-2ab2-scalance-xb213-3","title":"Siemens 6GK5213-3BB00-2AB2 SCALANCE XB213-3 13xRJ45 3xST Multimode Ethernet Switch","description":"\u003cp\u003eThe Siemens 6GK5213-3BB00-2AB2 SCALANCE XB213-3 is a managed Layer 2 industrial Ethernet switch with 13 RJ45 10\/100 Mbit\/s ports plus 3 ST multimode fiber ports, a console port, and redundant power inputs. It is IEC 62443-4-2 certified and rated for 0 to +60 degC operation with DIN-rail mounting and default PROFINET support.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5213-3BB00-2AB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XB213\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047622178430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXB213-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, 100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRJ45 Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Ports (ST, Multimode)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3, 100BaseFX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsole Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, RJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC, range 19.2 ... 28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.41 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6-pole terminal block, redundant supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\/Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% at 25 degC, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 mm x 117 mm x 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate (PC-GF10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. VLANs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Conformity Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, HRP, RSTP, RSTP+, PRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTelnet, TFTP, SFTP, BOOTP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x (RADIUS), RADIUS client, SSH, SSL, broadcast\/multicast\/unicast limiter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULHazLoc\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eIEC 62443-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe XB213-3 gives 13 copper ports plus 3 ST multimode fiber uplinks in one fixed configuration, so pick it when a cell needs more RJ45 device connections than the smaller XB205\/XB208 variants offer while still reaching a fiber backbone over multimode ST connectors. Its 0 to +60 degC rating targets indoor cabinets rather than outdoor or extended-temperature sites, where the XC series with -40 to +70 degC applies instead. IEC 62443-4-2 certification is relevant where the network segment falls under a component-level security requirement.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eManaged access-layer switching for PROFINET or EtherNet\/IP cells that combine many RJ45 field devices with a multimode fiber uplink to a plant backbone, under indoor ambient conditions.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959774306587,"sku":"6GK5213-3BB00-2AB2","price":1766.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5213-3bb00-2ab2-scalance-xb213-3-switch.png?v=1789824708"},{"product_id":"siemens-6gk5213-3bd00-2ab2-scalance-xb213-3-switch","title":"Siemens 6GK5213-3BD00-2AB2 SCALANCE XB213-3 13-Port Managed Layer 2 Ethernet Switch with SC Fiber","description":"\u003cp\u003eThe Siemens 6GK5213-3BD00-2AB2 SCALANCE XB213-3 is a managed Layer 2 Industrial Ethernet switch with 13x 10\/100 Mbit\/s RJ45 ports plus 3x SC multimode fiber ports (100BaseFX), redundant 24 V DC power, and IP20 protection for 0 to 60 °C operation. It is IEC 62443-4-2 certified and supports PROFINET conformity class B with MRP\/HRP ring redundancy.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5213-3BD00-2AB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622178416\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XB213\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eXB213-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Ports\u003c\/td\u003e\n\u003ctd\u003e13x 10\/100 Mbit\/s RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Ports\u003c\/td\u003e\n\u003ctd\u003e3x SC multimode, 100BaseFX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole Port\u003c\/td\u003e\n\u003ctd\u003e1x RJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement Port\u003c\/td\u003e\n\u003ctd\u003e1x RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n\u003ctd\u003e6-pole terminal block, redundant input, fused\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (19.2 ... 28.8 V range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss (Rated)\u003c\/td\u003e\n\u003ctd\u003e9.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current Consumption\u003c\/td\u003e\n\u003ctd\u003e0.41 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation)\u003c\/td\u003e\n\u003ctd\u003e0 ... 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Storage\/Transport)\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity (Max)\u003c\/td\u003e\n\u003ctd\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e120 x 117 x 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate (PC-GF10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax VLANs\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Conformity Class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Network Load Class\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Ethernet Telegram Length\u003c\/td\u003e\n\u003ctd\u003e1632 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eTelnet, TFTP, SFTP, BOOTP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP (snooping\/querier)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eMRP (with redundancy manager), MRP-I, HRP (manager and standby), STP, RSTP, RSTP+, PRP, passive listening\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x (RADIUS), RADIUS client, broadcast\/multicast\/unicast limiter, broadcast blocking, SSH, SSL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Synchronization\u003c\/td\u003e\n\u003ctd\u003eSICLOCK support, NTP client, SNTP client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, MIB support, port mirroring, multiport mirroring, port diagnostics, SysLog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e45 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM registration\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eIEC 62443-4-2:2019\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 3x SC multimode fiber ports separate this variant from a purely copper fixed switch: it fits segments that need a fiber uplink to a remote cabinet alongside 13 local RJ45 drops. The 0 to 60 °C operating range is narrower than a -40 °C-rated unit, so it suits indoor cabinets rather than unheated outdoor enclosures. MRP and HRP with redundancy-manager support let it act as a ring node, and PROFINET network load class III plus conformity class B fit larger PROFINET segments than a basic unmanaged switch.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003ePROFINET production cells needing a fiber-linked switch with 13 copper drops, ring-redundant topologies (MRP\/HRP) between cabinets, and IEC 62443-4-2-certified network segments in indoor industrial environments.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959775125787,"sku":"6GK5213-3BD00-2AB2","price":1766.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5213-3bd00-2ab2-scalance-xb213-3-switch.png?v=1789680731"},{"product_id":"siemens-6gk5213-3bf00-2ab2-scalance-xb213-3ld","title":"Siemens 6GK5213-3BF00-2AB2 SCALANCE XB213-3LD 13xRJ45 3xSC Single-Mode Ethernet Switch","description":"\u003cp\u003eThe Siemens 6GK5213-3BF00-2AB2 SCALANCE XB213-3LD is a managed Layer 2 industrial Ethernet switch with 13 RJ45 10\/100 Mbit\/s ports plus 3 SC single-mode long-distance fiber ports, a console port, and redundant power inputs. It is IEC 62443-4-2 certified and rated for 0 to +60 degC operation with DIN-rail mounting and default PROFINET support.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5213-3BF00-2AB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XB213\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047622178423\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXB213-3LD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, 100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRJ45 Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Ports (SC, Single-Mode LD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3, 100BaseLX LD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsole Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, RJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC, range 19.2 ... 28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6-pole terminal block, redundant supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\/Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% at 25 degC, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 mm x 117 mm x 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate (PC-GF10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. VLANs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Conformity Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, HRP, RSTP, RSTP+, PRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTelnet, TFTP, SFTP, BOOTP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x (RADIUS), RADIUS client, SSH, SSL, broadcast\/multicast\/unicast limiter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir Pollution Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANSI\/ISA-71.04 G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULHazLoc\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eIEC 62443-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe XB213-3LD swaps the XB213-3's multimode ST ports for 3 single-mode SC long-distance (LD) fiber ports, so choose it when a fiber run exceeds typical multimode distances and needs a long-haul optical budget instead. Otherwise it shares the XB213-3's 13-port RJ45 layout, indoor 0 to +60 degC rating, and IEC 62443-4-2 certification. Pick the multimode XB213-3 instead when the fiber backbone is already ST\/multimode and distance is not a constraint.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eManaged access-layer switching for PROFINET or EtherNet\/IP cells needing a single-mode fiber uplink over longer distances than multimode fiber supports, under indoor ambient conditions.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959775519003,"sku":"6GK5213-3BF00-2AB2","price":2202.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5213-3bf00-2ab2-scalance-xb213-3ld-switch.png?v=1789824716"},{"product_id":"siemens-6gk5216-0ba00-2ab2-scalance-xb216-ethernet-switch","title":"Siemens 6GK5216-0BA00-2AB2 SCALANCE XB216 16-Port 10\/100 Mbit\/s Managed Industrial Ethernet Switch","description":"\u003cp\u003eThe Siemens SCALANCE XB216 (6GK5216-0BA00-2AB2) is a managed Layer 2 Industrial Ethernet switch with 16x 10\/100 Mbit\/s RJ45 ports, IEC 62443-4-2 security certification, and PROFINET conformity class B diagnostics. It supports MRP and HRP ring redundancy with up to 257 VLANs, runs from a redundant 24 V DC supply, and is rated for 0 to +60C operation with IP20 protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrder Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5216-0BA00-2AB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XB216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePorts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16x RJ45, 10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, 100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsole Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x RJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.2 ... 28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundant Power Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.28 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 60 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage\/Transport Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% max, no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 x 117 x 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate (PC-GF10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax VLANs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Conformity Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Load Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Ethernet Telegram Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1632 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM registration\u003c\/li\u003e\n\u003cli\u003eIEC 62443-4-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eIEC 62443-4-2 certification and full management - CLI, web-based configuration, SNMPv3, RADIUS\/802.1x - separate the XB216 from the unmanaged XC-series switches, so choose it wherever the segment needs port-based VLANs, RSTP\/MRP ring redundancy, or SNMP-based network monitoring. PROFINET conformity class B with network load class III diagnostic reporting integrates the switch as a manageable network component in TIA Portal projects rather than a passive Ethernet distributor. Its 0 to +60C operating range is narrower than the compact XC-series' -40 to +70C, so an XC or XM unit fits unheated cabinets or outdoor enclosures better.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSuited to control-network backbones needing managed redundancy and diagnostics - machine-to-machine PROFINET segments in ring topology, and cabinets where SNMP-based monitoring and VLAN segmentation are part of the network design.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959775781147,"sku":"6GK5216-0BA00-2AB2","price":1319.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5216-0ba00-2ab2-scalance-xb216-ethernet-switch.png?v=1789714386"},{"product_id":"siemens-6gk5216-0ba00-2ac2-scalance-xc216","title":"Siemens 6GK5216-0BA00-2AC2 SCALANCE XC216 16-Port RJ45 Managed Ethernet Switch","description":"\u003cp\u003eThe Siemens 6GK5216-0BA00-2AC2 SCALANCE XC216 is a managed Layer 2 industrial Ethernet switch with 16 RJ45 10\/100 Mbit\/s ports, a console port, and redundant 24 V DC power inputs. Rated for -40 to +70 degC operation at IP20, it supports RSTP, MRP, and HRP ring redundancy with PROFINET IO diagnostics at conformity class B.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5216-0BA00-2AC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XC216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047622314869\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXC216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, 100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRJ45 Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsole Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, RJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignaling Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC \/ 0.1 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC, range 9.6 ... 31.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-pole terminal block, redundant supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 A \/ 125 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\/Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% at 25 degC, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 mm x 147 mm x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate (PC-GF10) \/ die-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail, wall, S7-300 rail, S7-1500 rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. VLANs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Conformity Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, HRP, RSTP, RSTP+, MSTP, STP, PRP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTelnet, TFTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x (RADIUS), RADIUS client, SSH, SSL, broadcast\/multicast\/unicast limiter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe XC216 gives 16 RJ45 ports in a single fixed-configuration switch, doubling the port count of the 8-port XC208 for cells with more field devices per segment. Its -40 to +70 degC rating and die-cast aluminum\/PC-GF10 enclosure suit outdoor cabinets or unheated switch rooms where the indoor-only XB series does not apply. Choose the fiber-uplink XC216-4C variants instead when the segment needs SFP or gigabit combo ports alongside the RJ45 count.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eManaged access-layer switching for larger PROFINET or EtherNet\/IP cells needing 16 RJ45 device connections with ring redundancy, in cabinets or machine panels exposed to wide temperature swings.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959776567579,"sku":"6GK5216-0BA00-2AC2","price":1597.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5216-0ba00-2ac2-scalance-xc216-switch.png?v=1789824723"},{"product_id":"siemens-6gk5216-0ha00-2as6-scalance-xp216","title":"Siemens 6GK5216-0HA00-2AS6 SCALANCE XP216 16-Port M12 IP65 Managed Ethernet Switch","description":"\u003cp\u003eThe Siemens 6GK5216-0HA00-2AS6 SCALANCE XP216 is a managed industrial Ethernet switch with 16 M12-coded ports: 12 at 10\/100 Mbit\/s and 4 at 10\/100\/1000 Mbit\/s. Rated IP65 for cabinet-free mounting and -40 to +70 degC operation, it runs PROFINET IO diagnostics at conformity class B with MRP and HRP ring redundancy.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5216-0HA00-2AS6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XP216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047622394199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXP216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, 100, 1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM12 Ports (10\/100 Mbit\/s, D-coded)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM12 Ports (10\/100\/1000 Mbit\/s, X-coded)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Network Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16, M12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsole Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, 5-pole M12 socket (A-coded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignaling Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-pole M12 plug (B-coded), 24 V DC \/ 0.1 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC, range 19.2 ... 28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x 4-pole M12 plug (A-coded), redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A \/ 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% at 25 degC, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm x 200 mm x 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eET200pro module carrier, wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. VLANs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Conformity Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, HRP, RSTP, RSTP+, MSTP, STP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTelnet, TFTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x (RADIUS), RADIUS client, SSH, SSL, broadcast\/multicast\/unicast limiter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe XP216 doubles the XP208's port count to 16 M12 connections, including 4 Gigabit-capable X-coded ports for a faster uplink or a mix of gigabit devices alongside 12 standard 10\/100 D-coded ports. Its IP65 aluminum housing and ET200pro carrier mounting let it sit directly on the machine without a control cabinet, unlike RJ45-based XC\/XB switches that need an IP20 enclosure. Choose the PoE variants of this series instead when field devices need to be powered directly from the switch.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eM12 field-mounted PROFINET switching for larger machine or plant networks that need both standard 10\/100 device ports and a Gigabit uplink, in vibration-exposed or outdoor installations.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959776796955,"sku":"6GK5216-0HA00-2AS6","price":2297.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5216-0ha00-2as6-scalance-xp216-switch.png?v=1789824730"},{"product_id":"siemens-6gk5216-0ha00-2es6-scalance-xp216eec","title":"Siemens 6GK5216-0HA00-2ES6 SCALANCE XP216EEC 16-Port M12 Railway Ethernet Switch","description":"\u003cp\u003eThe Siemens 6GK5216-0HA00-2ES6 SCALANCE XP216EEC is a managed industrial Ethernet switch with 16 M12-coded ports (12 at 10\/100 Mbit\/s, 4 at 10\/100\/1000 Mbit\/s) and railway approval to EN 50155 and EN 45545. Rated IP65 and -40 to +70 degC continuous (+85 degC for 10 minutes), it runs PROFINET IO diagnostics at conformity class B with MRP and HRP ring redundancy.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5216-0HA00-2ES6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XP216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047622310519\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXP216EEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, 100, 1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM12 Ports (10\/100 Mbit\/s, D-coded)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM12 Ports (10\/100\/1000 Mbit\/s, X-coded)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Network Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16, M12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsole Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, 5-pole M12 socket (A-coded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignaling Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-pole M12 plug (B-coded), 24 V DC \/ 0.1 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC, range 19.2 ... 28.8 V (EEC\/EN 50155: 16.8 ... 30 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x 4-pole M12 plug (A-coded), redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A \/ 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 degC (EEC: -40 ... +85 degC for 10 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% at 25 degC, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm x 200 mm x 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAluminum, conformal coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eET200pro module carrier, wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. VLANs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Conformity Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, HRP, RSTP, RSTP+, MSTP, STP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTelnet, TFTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x (RADIUS), RADIUS client, SSH, SSL, broadcast\/multicast\/unicast limiter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe EEC suffix marks the railway-approved build of the XP216: EN 50155 and EN 45545 compliance and a conformal-coated aluminum enclosure add rolling-stock qualification on top of the same 16-port M12 layout as the standard XP216. Its supply voltage range widens to 16.8...30 V DC for EN 50155 traction supply tolerances, and the -40 degC to +85 degC 10-minute rating covers rail cold-start and thermal-shock test profiles. Pick the standard XP216 instead for stationary industrial or outdoor machine applications that do not need railway type approval.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eM12 field-mounted PROFINET switching for rolling-stock and trackside networks requiring EN 50155\/EN 45545 railway approval alongside 10\/100 and Gigabit device connectivity.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959777124635,"sku":"6GK5216-0HA00-2ES6","price":2466.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5216-0ha00-2es6-scalance-xp216eec-switch.png?v=1789824737"},{"product_id":"siemens-6gk5216-0ua00-5es6-scalance-xp216poe-eec","title":"Siemens 6GK5216-0UA00-5ES6 SCALANCE XP216PoE EEC 16-Port M12 PoE Railway Switch","description":"\u003cp\u003eThe Siemens 6GK5216-0UA00-5ES6 SCALANCE XP216PoE EEC is a managed industrial Ethernet switch with 16 M12-coded ports, 8 of which supply Power over Ethernet at up to 30 W per port and 120 W total, plus railway approval to EN 50155 and EN 45545. Rated IP65 and -40 to +70 degC continuous, it runs PROFINET IO diagnostics at conformity class B with MRP and HRP redundancy.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5216-0UA00-5ES6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XP216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047622310465\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXP216PoE EEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, 100, 1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM12 Ports (10\/100 Mbit\/s, D-coded)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM12 Ports (10\/100 Mbit\/s) with PoE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM12 Ports (10\/100\/1000 Mbit\/s, X-coded)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eM12 Ports (10\/100\/1000 Mbit\/s) with PoE\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Network Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16, M12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE Power, per Port \/ Total\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 W max. \/ 120 W max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsole Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, 5-pole M12 socket (A-coded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignaling Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-pole M12 plug (B-coded), 54 V DC \/ 0.1 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (PoE)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54 V DC, range 46 ... 57 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x 4-pole M12 plug (A-coded), redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A \/ 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 degC (EEC: -40 ... +85 degC for 10 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% at 25 degC, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 mm x 200 mm x 49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAluminum, conformal coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eET200pro module carrier, wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. VLANs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Conformity Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, HRP, RSTP, RSTP+, MSTP, STP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTelnet, TFTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x (RADIUS), RADIUS client, SSH, SSL, broadcast\/multicast\/unicast limiter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe XP216PoE EEC combines the 16-port M12 XP216 layout with 8 PoE-capable ports (6 at 10\/100 Mbit\/s, 2 Gigabit) and EN 50155\/EN 45545 railway approval, so specify it when rolling-stock or trackside equipment needs to power PoE devices such as cameras directly from the switch. Compared with the non-PoE XP216EEC, the higher 54 V PoE supply and 13 W rated power loss reflect the added PSE circuitry. Choose the standard XP216PoE (non-EEC) instead for stationary field installations that do not require railway type approval.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eM12 field-mounted PROFINET switching for rolling-stock or trackside networks that need to power PoE cameras or wireless access points directly, under EN 50155\/EN 45545 railway approval.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959777419547,"sku":"6GK5216-0UA00-5ES6","price":3076.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5216-0ua00-5es6-scalance-xp216poe-eec-switch.png?v=1789824744"},{"product_id":"siemens-6gk5216-4bs00-2ac2-scalance-xc216-4c","title":"Siemens 6GK5216-4BS00-2AC2 SCALANCE XC216-4C 12xRJ45 4xCombo Ethernet Switch","description":"\u003cp\u003eThe Siemens 6GK5216-4BS00-2AC2 SCALANCE XC216-4C is a managed Layer 2 industrial Ethernet switch with 12 RJ45 10\/100 Mbit\/s ports plus 4 Gigabit combo ports that accept either RJ45 or SFP fiber transceivers. Rated for -40 to +70 degC operation at IP20 with redundant 24 V DC supply, it supports RSTP, MRP, HRP, and PRP redundancy at PROFINET conformity class B.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5216-4BS00-2AC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XC216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047622642597\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXC216-4C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, 100, 1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRJ45 Ports (10\/100 Mbit\/s)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombo Ports (1000 Mbit\/s RJ45 or SFP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSFP Slots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsole Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, RJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignaling Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC, range 9.6 ... 31.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-pole terminal block, permanently installed, redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.15 A \/ 125 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\/Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% at 25 degC, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mm x 150 mm x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate (PC-GF10) \/ die-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail, wall, S7-300 rail, S7-1500 rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. VLANs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Conformity Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, HRP, RSTP, RSTP+, MSTP, STP, PRP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTelnet, TFTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x (RADIUS), RADIUS client, SSH, SSL, broadcast\/multicast\/unicast limiter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe XC216-4C adds 4 Gigabit combo ports (RJ45 or SFP, user-selectable) to the 12-port RJ45 XC216-4C layout, so choose it when the segment needs a fiber or copper Gigabit uplink alongside standard 10\/100 device ports without stepping up to the full-Gigabit XC216-4C G. It shares the XC216 family's -40 to +70 degC range and die-cast aluminum\/PC-GF10 enclosure for outdoor cabinets or unheated switch rooms. Pick the plain XC216 instead when no Gigabit uplink or SFP option is needed.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eManaged access-layer switching for PROFINET or EtherNet\/IP cells needing 10\/100 device ports plus a Gigabit fiber or copper uplink, in cabinets exposed to wide temperature ranges.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959777681691,"sku":"6GK5216-4BS00-2AC2","price":1948.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5216-4bs00-2ac2-scalance-xc216-4c-switch.png?v=1789824750"},{"product_id":"siemens-6gk5216-4gs00-2ac2-scalance-xc216-4c-g","title":"Siemens 6GK5216-4GS00-2AC2 SCALANCE XC216-4C G Full Gigabit 16xRJ45 4xSFP Switch","description":"\u003cp\u003eThe Siemens 6GK5216-4GS00-2AC2 SCALANCE XC216-4C G is a full-Gigabit managed Layer 2 switch with 16 10\/100\/1000 Mbit\/s RJ45 ports plus 4 Gigabit combo ports for RJ45 or SFP transceivers. Rated for -40 to +70 degC operation at IP20 with redundant 24 V DC supply, it adds IEEE 1588v2 PTP timing on top of RSTP, MRP, HRP, and PRP redundancy.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5216-4GS00-2AC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XC216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047622642542\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXC216-4C G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, 100, 1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRJ45 Ports (10\/100\/1000 Mbit\/s)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombo Ports (1000 Mbit\/s RJ45 or SFP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSFP Slots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsole Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, RJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignaling Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC, range 9.6 ... 31.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-pole terminal block, permanently installed, redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.15 A \/ 125 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\/Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% at 25 degC, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mm x 150 mm x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate (PC-GF10) \/ die-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail, wall, S7-300 rail, S7-1500 rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. VLANs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Conformity Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588v2 PTP, default profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, HRP, RSTP, RSTP+, MSTP, STP, PRP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTelnet, TFTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x (RADIUS), RADIUS client, SSH, SSL, broadcast\/multicast\/unicast limiter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe XC216-4C G upgrades all 16 fixed ports to 10\/100\/1000 Mbit\/s and adds IEEE 1588v2 PTP timing, so choose it over the mixed-speed XC216-4C when every connected device is Gigabit-capable or the application needs PTP time synchronization across the network. The 4 SFP-capable combo ports still allow a fiber uplink alongside the full-Gigabit copper ports. Pick the XC216-4C instead when most field devices are 10\/100 and full Gigabit throughput on every port is not required.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eFull-Gigabit managed switching for PROFINET or EtherNet\/IP networks needing IEEE 1588v2 time synchronization alongside a Gigabit fiber or copper uplink, in cabinets exposed to wide temperature ranges.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959777943835,"sku":"6GK5216-4GS00-2AC2","price":2287.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5216-4gs00-2ac2-scalance-xc216-4c-g-switch.png?v=1789824757"},{"product_id":"siemens-6gk5224-0ba00-2ac2-scalance-xc224-ethernet-switch","title":"Siemens 6GK5224-0BA00-2AC2 SCALANCE XC224 24-Port 10\/100 Mbit\/s Managed Industrial Ethernet Switch","description":"\u003cp\u003eThe Siemens SCALANCE XC224 (6GK5224-0BA00-2AC2) is a managed Layer 2 Industrial Ethernet switch with 24x 10\/100 Mbit\/s RJ45 ports, a C-PLUG slot for configuration transfer, and PROFINET conformity class B. It runs from a redundant 24 V DC supply, operates across -40 to +70C - wider than the XB-series' 0 to +60C - and carries IP20 protection with DIN rail, S7 rail, or wall mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrder Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5224-0BA00-2AC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XC224\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePorts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24x RJ45, 10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, 100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsole Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x RJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignaling Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC \/ 0.1 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eC-PLUG Slot\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.6 ... 31.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundant Power Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.75 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 A \/ 125 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage\/Transport Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +85 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% max, no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 x 147 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.88 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate (PC-GF10) \/ pressure die cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail, wall, S7-300 rail, S7-1500 rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax VLANs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Conformity Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET System Redundancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Ethernet Telegram Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1632 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM registration\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe XC224 extends the XC-series' -40 to +70C wide-temperature range to 24 managed ports, with a C-PLUG slot that lets a spare unit inherit a failed switch's configuration without a PC - useful where field replacement has to happen fast. PROFINET system redundancy and H-Sync forwarding support put it a step above the XB216 in redundant-controller topologies. Choose the 16-port XB216 instead when the segment stays indoors at 0 to +60C and doesn't need the extra 8 ports or the C-PLUG swap-out workflow.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eFits larger machine or line-level PROFINET segments needing managed redundancy - RSTP, MRP, system redundancy - across 24 ports, including outdoor or unheated-cabinet installations where the -40 to +70C rating matters.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959778664731,"sku":"6GK5224-0BA00-2AC2","price":2347.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5224-0ba00-2ac2-scalance-xc224-ethernet-switch.png?v=1789714393"},{"product_id":"siemens-6gk5224-4gs00-2ac2-scalance-xc224-4c-g","title":"Siemens 6GK5224-4GS00-2AC2 SCALANCE XC224-4C G Full Gigabit 24xRJ45 4xSFP Switch","description":"\u003cp\u003eThe Siemens 6GK5224-4GS00-2AC2 SCALANCE XC224-4C G is a full-Gigabit managed Layer 2 switch with 24 10\/100\/1000 Mbit\/s RJ45 ports plus 4 Gigabit combo ports for RJ45 or SFP transceivers. Rated for -40 to +70 degC operation at IP20 with redundant 24 V DC supply, it adds IEEE 1588v2 PTP timing on top of RSTP, MRP, HRP, and PRP redundancy.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5224-4GS00-2AC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XC224\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047622642566\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXC224-4C G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, 100, 1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRJ45 Ports (10\/100\/1000 Mbit\/s)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombo Ports (1000 Mbit\/s RJ45 or SFP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSFP Slots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsole Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, RJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignaling Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC, range 9.6 ... 31.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-pole terminal block, permanently installed, redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.15 A \/ 125 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\/Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% at 25 degC, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mm x 150 mm x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate (PC-GF10) \/ die-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail, wall, S7-300 rail, S7-1500 rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. VLANs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Conformity Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTiming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588v2 PTP, default profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, HRP, RSTP, RSTP+, MSTP, STP, PRP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTelnet, TFTP, SFTP, BOOTP, GMRP, DCP, LLDP, EtherNet\/IP, SNMP v1\/v2\/v3, IGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x (RADIUS), RADIUS client, SSH, SSL, broadcast\/multicast\/unicast limiter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe XC224-4C G steps up from the 16-port XC216-4C G to 24 full-Gigabit RJ45 ports plus 4 SFP-capable combo ports, so specify it for backbone or aggregation points that need more Gigabit device connections than the 216 family offers. IEEE 1588v2 PTP timing and the same -40 to +70 degC\/IP20 rating carry over from the 216-series, so choose this variant purely on port count. Pick the 216-series instead when 24 ports exceed the segment's actual device count.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eFull-Gigabit managed switching for larger PROFINET or EtherNet\/IP backbones needing IEEE 1588v2 time synchronization and a Gigabit fiber or copper uplink, in cabinets exposed to wide temperature ranges.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959778926875,"sku":"6GK5224-4GS00-2AC2","price":3061.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5224-4gs00-2ac2-scalance-xc224-4c-g-switch.png?v=1789824764"},{"product_id":"siemens-6gk5324-0ba00-2ar3-scalance-xr324wg","title":"Siemens 6GK5324-0BA00-2AR3 SCALANCE XR324WG 24x RJ45 DC24V 19-Inch Managed Switch","description":"\u003cp\u003eThe Siemens 6GK5324-0BA00-2AR3 SCALANCE XR324WG is a managed Layer 2 Industrial Ethernet switch built for 19-inch rack mounting, with 24 electrical 10\/100 Mbit\/s RJ45 ports on a 24 V DC supply. It carries IEC 62443-4-2 certification for its network management functions and supports MRP\/HRP ring redundancy with a redundancy manager, meeting PROFINET conformity class B and network load class II.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5324-0BA00-2AR3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622504659\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eXR324 WG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer rate\u003c\/td\u003e\n\u003ctd\u003e10, 100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 ports\u003c\/td\u003e\n\u003ctd\u003e24, electrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (19.2 ... 28.8 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, rated\u003c\/td\u003e\n\u003ctd\u003e7.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. current consumption\u003c\/td\u003e\n\u003ctd\u003e0.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower connector\u003c\/td\u003e\n\u003ctd\u003e2 x 2-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse protection\u003c\/td\u003e\n\u003ctd\u003eF 5 A \/ 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement functions\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, MIB support, SNMP v1\/v2\/v3, Telnet, TFTP, FTP, BOOTP, DCP, LLDP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, HRP, STP, RSTP, PRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. VLANs\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET conformity class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork load class\u003c\/td\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e483 x 44 x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e2.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, operation\u003c\/td\u003e\n\u003ctd\u003e0 ... +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e56 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003cli\u003eCCC-Ex\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the 24 V DC-supplied version, suited to 19-inch cabinets already carrying a 24 V DC power bus, which avoids running a separate mains feed to the rack; an AC 230 V sibling exists for cabinets that only distribute mains voltage. With 24 electrical 10\/100 Mbit\/s ports and no PoE or gigabit uplinks, this XR324WG is a straight Fast Ethernet aggregation switch — a PoE-capable, gigabit-ready XR324-4M variant exists where powered endpoints or fiber uplinks are needed.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003e19-inch rack-mounted aggregation for PROFINET networks that need MRP ring redundancy across 24 Fast Ethernet field devices, in cabinets built around a 24 V DC power bus.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959779189019,"sku":"6GK5324-0BA00-2AR3","price":1621.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5324-0ba00-2ar3-scalance-xr324wg-switch.png?v=1789824770"},{"product_id":"siemens-6gk5324-0ba00-3ar3-scalance-xr324wg","title":"Siemens 6GK5324-0BA00-3AR3 SCALANCE XR324WG 24x RJ45 AC230V 19-Inch Managed Switch","description":"\u003cp\u003eThe Siemens 6GK5324-0BA00-3AR3 SCALANCE XR324WG is a managed Layer 2 Industrial Ethernet switch for 19-inch rack mounting, with 24 electrical 10\/100 Mbit\/s RJ45 ports and a 230 V AC (85 ... 264 V) power input via IEC C14 inlet. It supports MRP\/HRP ring redundancy with a redundancy manager and meets PROFINET conformity class B and network load class II.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5324-0BA00-3AR3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622504666\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eXR324 WG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer rate\u003c\/td\u003e\n\u003ctd\u003e10, 100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 ports\u003c\/td\u003e\n\u003ctd\u003e24, electrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e240 V AC (85 ... 264 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, rated\u003c\/td\u003e\n\u003ctd\u003e9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. current consumption\u003c\/td\u003e\n\u003ctd\u003e0.09 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower connector\u003c\/td\u003e\n\u003ctd\u003eIEC plug C14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse protection\u003c\/td\u003e\n\u003ctd\u003eF 4 A \/ 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement functions\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, MIB support, SNMP v1\/v2\/v3, Telnet, TFTP, FTP, BOOTP, DCP, LLDP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, HRP, STP, RSTP, PRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. VLANs\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET conformity class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork load class\u003c\/td\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e483 x 44 x 177 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e3.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, operation\u003c\/td\u003e\n\u003ctd\u003e0 ... +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e50 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis 230 V AC (85 ... 264 V) supply variant fits 19-inch cabinets that only distribute mains power, drawing a maximum 0.09 A through an IEC C14 inlet instead of a terminal block — a 24 V DC-supplied sibling exists for cabinets built around a DC power bus. Port count, redundancy protocols, and PROFINET conformity class B are otherwise identical to that DC sibling, so the choice comes down to which power infrastructure the cabinet already carries.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003e19-inch rack-mounted aggregation for PROFINET networks needing MRP ring redundancy across 24 Fast Ethernet field devices, in cabinets fed from a mains AC supply.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959779680539,"sku":"6GK5324-0BA00-3AR3","price":1742.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5324-0ba00-3ar3-scalance-xr324wg-switch.png?v=1789824777"},{"product_id":"siemens-6gk5324-4qg10-1ar2-scalance-xr324-4m-poe","title":"Siemens 6GK5324-4QG10-1AR2 SCALANCE XR324-4M PoE DC24V Front-Port Managed Switch","description":"\u003cp\u003eThe Siemens 6GK5324-4QG10-1AR2 SCALANCE XR324-4M PoE is a managed Layer 2 Industrial Ethernet switch for 19-inch rack mounting, with 16 electrical 10\/100\/1000 Mbit\/s RJ45 ports (8 of them PoE-capable) plus four slots for 2-port media modules, all accessed from the front. It runs from a 24 V DC supply and supports MRP\/HRP ring redundancy with a redundancy manager, meeting PROFINET conformity class B.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5324-4QG10-1AR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622527252\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eXR324-4M PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort layout\u003c\/td\u003e\n\u003ctd\u003ePorts on front panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer rate\u003c\/td\u003e\n\u003ctd\u003e10, 100, 1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 ports\u003c\/td\u003e\n\u003ctd\u003e16 electrical, 8 with PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia module slots\u003c\/td\u003e\n\u003ctd\u003e4, 2-port each, electrical or optical (up to 8x 100 Mbit\/s ST\/SC fiber)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eRJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling contact\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC \/ 0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable storage\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (19.2 ... 28.8 V), redundant supply input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, rated\u003c\/td\u003e\n\u003ctd\u003e46 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. current consumption\u003c\/td\u003e\n\u003ctd\u003e4.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower connector\u003c\/td\u003e\n\u003ctd\u003e4-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse protection\u003c\/td\u003e\n\u003ctd\u003eF 5 A \/ 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement functions\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, MIB support, SNMP v1\/v2\/v3, Telnet, TFTP, FTP, BOOTP, GMRP, DCP, LLDP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, HRP, STP, RSTP, MSTP, PRP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. VLANs\u003c\/td\u003e\n\u003ctd\u003e255\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET conformity class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRing reconfiguration\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.3 s (ring of up to 100 switches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e449 x 43.6 x 305 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e6.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, operation\u003c\/td\u003e\n\u003ctd\u003e-40 ... +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003cli\u003eCCC-Ex\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eFront-facing ports suit cabinets that are only accessible from one side; a rear-port sibling routes the same 16 electrical + media-module ports to the back for cabinets wired from behind, and AC-supplied siblings exist for cabinets without a 24 V DC bus. All variants in this design share the eight PoE-capable ports and four modular media slots, so pick this one by mounting orientation and available power, not feature set.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMachine or process-cell aggregation switch feeding PoE-powered cameras or WLAN access points alongside conventional Gigabit Ethernet devices, with modular slots to add fiber uplinks as the plant's backbone grows.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959779942683,"sku":"6GK5324-4QG10-1AR2","price":6278.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5324-4qg10-1ar2-scalance-xr324-4m-poe-switch.png?v=1789824783"},{"product_id":"siemens-6gk5324-4qg10-1hr2-scalance-xr324-4m-poe","title":"Siemens 6GK5324-4QG10-1HR2 SCALANCE XR324-4M PoE DC24V Rear-Port Managed Switch","description":"\u003cp\u003eThe Siemens 6GK5324-4QG10-1HR2 SCALANCE XR324-4M PoE is a managed Layer 2 Industrial Ethernet switch for 19-inch rack mounting, with 16 electrical 10\/100\/1000 Mbit\/s RJ45 ports (8 of them PoE-capable) plus four slots for 2-port media modules, all accessed from the rear. It runs from a 24 V DC supply and supports MRP\/HRP ring redundancy with a redundancy manager, meeting PROFINET conformity class B.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5324-4QG10-1HR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622531907\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eXR324-4M PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort layout\u003c\/td\u003e\n\u003ctd\u003ePorts on rear panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer rate\u003c\/td\u003e\n\u003ctd\u003e10, 100, 1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 ports\u003c\/td\u003e\n\u003ctd\u003e16 electrical, 8 with PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia module slots\u003c\/td\u003e\n\u003ctd\u003e4, 2-port each, electrical or optical (up to 8x 100 Mbit\/s ST\/SC fiber)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eRJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling contact\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC \/ 0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable storage\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (19.2 ... 28.8 V), redundant supply input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, rated\u003c\/td\u003e\n\u003ctd\u003e46 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. current consumption\u003c\/td\u003e\n\u003ctd\u003e4.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower connector\u003c\/td\u003e\n\u003ctd\u003e4-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse protection\u003c\/td\u003e\n\u003ctd\u003eF 5 A \/ 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement functions\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, MIB support, SNMP v1\/v2\/v3, Telnet, TFTP, FTP, BOOTP, GMRP, DCP, LLDP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, HRP, STP, RSTP, MSTP, PRP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. VLANs\u003c\/td\u003e\n\u003ctd\u003e255\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET conformity class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRing reconfiguration\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.3 s (ring of up to 100 switches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e449 x 43.6 x 305 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e6.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, operation\u003c\/td\u003e\n\u003ctd\u003e-40 ... +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003cli\u003eCCC-Ex\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRear ports route cabling behind the rack instead of the front, matching cabinets wired from the back; a front-port sibling and AC-supplied siblings cover the other mounting\/power combinations in this design. The 24 V DC, 46 W supply and eight PoE-capable ports are unchanged from the front-port variant, so the choice here is purely about cable routing direction.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMachine or process-cell aggregation switch feeding PoE-powered cameras or WLAN access points alongside conventional Gigabit Ethernet devices, in cabinets wired from behind the rack.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959780237595,"sku":"6GK5324-4QG10-1HR2","price":6278.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5324-4qg10-1hr2-scalance-xr324-4m-poe-switch.png?v=1789824789"},{"product_id":"siemens-6gk5324-4qg10-3ar2-scalance-xr324-4m-poe","title":"Siemens 6GK5324-4QG10-3AR2 SCALANCE XR324-4M PoE AC230V Front-Port Managed Switch","description":"\u003cp\u003eThe Siemens 6GK5324-4QG10-3AR2 SCALANCE XR324-4M PoE is a managed Layer 2 Industrial Ethernet switch for 19-inch rack mounting, with 16 electrical 10\/100\/1000 Mbit\/s RJ45 ports (8 of them PoE-capable) plus four slots for 2-port media modules, all accessed from the front. It runs from a 230 V AC (85 ... 264 V) supply and supports MRP\/HRP ring redundancy with a redundancy manager, meeting PROFINET conformity class B.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5324-4QG10-3AR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622468531\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eXR324-4M PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort layout\u003c\/td\u003e\n\u003ctd\u003ePorts on front panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer rate\u003c\/td\u003e\n\u003ctd\u003e10, 100, 1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 ports\u003c\/td\u003e\n\u003ctd\u003e16 electrical, 8 with PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia module slots\u003c\/td\u003e\n\u003ctd\u003e4, 2-port each, electrical or optical (up to 8x 100 Mbit\/s ST\/SC fiber)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eRJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling contact\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC \/ 0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable storage\u003c\/td\u003e\n\u003ctd\u003eC-PLUG, included in scope of delivery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC (85 ... 264 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, rated\u003c\/td\u003e\n\u003ctd\u003e46 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. current consumption\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower connector\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement functions\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, MIB support, SNMP v1\/v2\/v3, Telnet, TFTP, FTP, BOOTP, GMRP, DCP, LLDP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, HRP, STP, RSTP, MSTP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. VLANs\u003c\/td\u003e\n\u003ctd\u003e255\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET conformity class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRing reconfiguration\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.3 s (ring of up to 100 switches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e449 x 43.6 x 305 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e6.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, operation\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eRINA\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 230 V AC (85 ... 264 V) supply removes the need for a separate 24 V DC feed to the rack, drawing a maximum of 1 A at rated voltage and carrying a wider -40 ... +70 °C ambient rating than the DC-supplied sibling's -40 ... +60 °C. This front-port, AC-supplied build also lists cULus and RINA marine classification, which the DC-supplied siblings in this family do not carry. Choose the DC-supplied siblings instead where the cabinet already runs a 24 V bus.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMachine or process-cell aggregation switch feeding PoE-powered cameras or WLAN access points alongside conventional Gigabit Ethernet devices, in mains-fed cabinets including marine and offshore installations covered by the RINA classification.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959780466971,"sku":"6GK5324-4QG10-3AR2","price":6278.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5324-4qg10-3ar2-scalance-xr324-4m-poe-switch.png?v=1789824795"},{"product_id":"siemens-6gk5324-4qg10-3hr2-scalance-xr324-4m-poe","title":"Siemens 6GK5324-4QG10-3HR2 SCALANCE XR324-4M PoE AC230V Rear-Port Managed Switch","description":"\u003cp\u003eThe Siemens 6GK5324-4QG10-3HR2 SCALANCE XR324-4M PoE is a managed Layer 2 Industrial Ethernet switch for 19-inch rack mounting, with 16 electrical 10\/100\/1000 Mbit\/s RJ45 ports (8 of them PoE-capable) plus four slots for 2-port media modules, all accessed from the rear. It runs from a 230 V AC (85 ... 264 V) supply and supports MRP\/HRP ring redundancy with a redundancy manager, meeting PROFINET conformity class B.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5324-4QG10-3HR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622545904\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eXR324-4M PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort layout\u003c\/td\u003e\n\u003ctd\u003ePorts on rear panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer rate\u003c\/td\u003e\n\u003ctd\u003e10, 100, 1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 ports\u003c\/td\u003e\n\u003ctd\u003e16 electrical, 8 with PoE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia module slots\u003c\/td\u003e\n\u003ctd\u003e4, 2-port each, electrical or optical (up to 8x 100 Mbit\/s ST\/SC fiber)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eRJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling contact\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC \/ 0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable storage\u003c\/td\u003e\n\u003ctd\u003eC-PLUG, included in scope of delivery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC (85 ... 264 V), redundant supply input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, rated\u003c\/td\u003e\n\u003ctd\u003e46 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. current consumption\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower connector\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement functions\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, MIB support, SNMP v1\/v2\/v3, Telnet, TFTP, FTP, BOOTP, GMRP, DCP, LLDP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, HRP, STP, RSTP, MSTP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. VLANs\u003c\/td\u003e\n\u003ctd\u003e255\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET conformity class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRing reconfiguration\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.3 s (ring of up to 100 switches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e449 x 43.6 x 305 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e6.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, operation\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eRINA\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eRear ports route cabling behind the rack instead of the front, matching cabinets wired from the back; a front-port AC sibling and DC-supplied siblings cover the other mounting\/power combinations. This build shares the front-port AC variant's 230 V (85 ... 264 V) supply, cULus listing, and -40 ... +70 °C ambient rating, plus a redundant power input this particular unit adds.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eMachine or process-cell aggregation switch feeding PoE-powered cameras or WLAN access points alongside conventional Gigabit Ethernet devices, in mains-fed cabinets wired from behind the rack.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959780761883,"sku":"6GK5324-4QG10-3HR2","price":6278.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5324-4qg10-3hr2-scalance-xr324-4m-poe-switch.png?v=1789824801"},{"product_id":"siemens-6gk5324-8ts00-2ac2-scalance-xc316-8","title":"Siemens 6GK5324-8TS00-2AC2 SCALANCE XC316-8 16x RJ45 8x SFP+ 10G Managed Switch","description":"\u003cp\u003eThe Siemens 6GK5324-8TS00-2AC2 SCALANCE XC316-8 is a managed Layer 2 Industrial Ethernet switch in a compact, fanless DIN-rail housing, with 16 electrical 10\/100\/1000 Mbit\/s RJ45 ports and 8 SFP+ slots supporting 1 or 10 Gbit\/s modules. It runs from a 24 V DC supply, supports MRP ring redundancy with PRP\/HSR network access redundancy, and meets PROFINET conformity class B.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5324-8TS00-2AC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622954775\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XC316\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eXC316-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer rate\u003c\/td\u003e\n\u003ctd\u003e10, 100, 1000 Mbit\/s; SFP+ up to 10 Gbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 ports\u003c\/td\u003e\n\u003ctd\u003e16, electrical, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP+ slots\u003c\/td\u003e\n\u003ctd\u003e8, 1000 Mbps and 10000 Mbps SFP usable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 Type B (USB-to-serial adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling contact\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC \/ 0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable storage\u003c\/td\u003e\n\u003ctd\u003eCLP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (19.2 ... 28.8 V), redundant supply input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, rated\u003c\/td\u003e\n\u003ctd\u003e43.2 W (25.92 W typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. current consumption\u003c\/td\u003e\n\u003ctd\u003e1.8 A (1.08 A typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower connector\u003c\/td\u003e\n\u003ctd\u003e2 x 2-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse protection\u003c\/td\u003e\n\u003ctd\u003eF 10 A \/ 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. telegram length\u003c\/td\u003e\n\u003ctd\u003e9194 byte (jumbo frames)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQoS queues\u003c\/td\u003e\n\u003ctd\u003e8 per port, IEEE 802.1Q\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. MAC addresses\u003c\/td\u003e\n\u003ctd\u003e16382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement functions\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, MIB support, SNMP v1\/v2\/v3, Telnet, TFTP, FTP, SFTP, EtherNet\/IP, DCP, LLDP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, MRP-I, HRP, STP, RSTP, RSTP+, MSTP, HSR, PRP (incl. RNA), eRSTP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. VLANs\u003c\/td\u003e\n\u003ctd\u003e257, incl. VXLAN (RFC 7348)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET conformity class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork load class\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail, wall, S7-300 or S7-1500 rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e210 x 147 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, operation\u003c\/td\u003e\n\u003ctd\u003e-40 ... +60 °C, fanless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003cli\u003eCCC-Ex\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the fixed Layer 2 model in the 16x RJ45 + 8x SFP+ compact-housing family; a Layer-3-upgradeable sibling with NETCONF automation exists for sites that need routing or infrastructure-as-code from the same physical unit. Choose this XC316-8 where VXLAN tunneling (RFC 7348), PRP\/HSR redundancy, and DHCP server functions cover the requirement, since the Layer 3 upgrade license adds cost this model doesn't carry. The 8 SFP+ slots take either 1 Gbit\/s or 10 Gbit\/s modules, so uplink speed is set by transceiver choice rather than switch variant.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eDIN-rail aggregation switch for machine networks needing a mix of gigabit copper and 1\/10G fiber uplinks, MRP or PRP\/HSR redundancy, and configuration-in-RUN (CiR) changes without a network outage.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959781024027,"sku":"6GK5324-8TS00-2AC2","price":3508.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5324-8ts00-2ac2-scalance-xc316-8-switch.png?v=1789824808"},{"product_id":"siemens-6gk5324-8ts01-2ac2-scalance-xcm324","title":"Siemens 6GK5324-8TS01-2AC2 SCALANCE XCM324 16x RJ45 8x SFP+ Layer-3 Managed Switch","description":"\u003cp\u003eThe Siemens 6GK5324-8TS01-2AC2 SCALANCE XCM324 is a managed Layer 2 Industrial Ethernet switch in a compact, fanless DIN-rail housing, with 16 electrical 10\/100\/1000 Mbit\/s RJ45 ports and 8 SFP+ slots supporting 1 or 10 Gbit\/s modules. It runs from a 24 V DC supply, is upgradeable to Layer 3 via license, and meets PROFINET conformity class B with NETCONF-based automation support.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6GK5324-8TS01-2AC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047622954744\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eXCM324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer rate\u003c\/td\u003e\n\u003ctd\u003e10, 100, 1000 Mbit\/s; SFP+ up to 10 Gbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRJ45 ports\u003c\/td\u003e\n\u003ctd\u003e16, electrical, with securing collar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSFP+ slots\u003c\/td\u003e\n\u003ctd\u003e8, 1000\/10000 Mbps SFP; 100 Mbps via SFP991-1(LD)A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsole port\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 Type B (USB-to-serial adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignaling contact\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC \/ 0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemovable storage\u003c\/td\u003e\n\u003ctd\u003eCLP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpgrade license\u003c\/td\u003e\n\u003ctd\u003eLayer 3 license available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (19.2 ... 28.8 V), redundant supply input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss, rated\u003c\/td\u003e\n\u003ctd\u003e43.2 W (25.92 W typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. current consumption\u003c\/td\u003e\n\u003ctd\u003e1.8 A (1.08 A typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower connector\u003c\/td\u003e\n\u003ctd\u003e2 x 2-pole terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse protection\u003c\/td\u003e\n\u003ctd\u003eF 10 A \/ 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. telegram length\u003c\/td\u003e\n\u003ctd\u003e9194 byte (jumbo frames)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame preemption\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1Qbu \/ 802.3br\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManagement functions\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, MIB support, SNMP v1\/v2\/v3, TFTP, FTP, SFTP, NETCONF, EtherNet\/IP, DCP, LLDP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy protocols\u003c\/td\u003e\n\u003ctd\u003eMRP, STP, RSTP, MSTP, eRSTP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. VLANs\u003c\/td\u003e\n\u003ctd\u003e2048\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET conformity class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork load class\u003c\/td\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime protocols\u003c\/td\u003e\n\u003ctd\u003eSICLOCK, NTP, IEEE 1588 v2 transparent forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail, wall, S7-300 or S7-1500 rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e210 x 147 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, operation\u003c\/td\u003e\n\u003ctd\u003e-40 ... +60 °C, fanless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULhazloc\u003c\/li\u003e\n\u003cli\u003eCCC-Ex\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis XCM324 variant is the Layer-3-upgradeable model in the same 16x RJ45 + 8x SFP+ compact housing as its fixed-Layer-2 sibling, adding a purchasable layer-3 license, NETCONF automation, RADIUS support, and IEEE 802.1Qbu\/802.3br frame preemption. It also carries railway approvals (EN 50121-4 and EN 50125-3, for use in areas not accessible to the public) that the fixed-Layer-2 sibling does not list, which matters for trackside or rolling-stock installations. The 2048-VLAN ceiling is eight times the sibling's 257, useful where the network is segmented more finely.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eDIN-rail aggregation switch for networks that may need Layer 3 routing later, automated configuration via NETCONF, or deterministic frame scheduling (802.1Qbu preemption) alongside gigabit copper and 1\/10G fiber uplinks.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959781318939,"sku":"6GK5324-8TS01-2AC2","price":3508.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5324-8ts01-2ac2-scalance-xcm324-switch.png?v=1789824815"}],"url":"https:\/\/stoklink.com\/collections\/industrial-ethernet-switches.oembed?page=2","provider":"Stoklink","version":"1.0","type":"link"}