{"title":"Heavy Duty Connectors","description":"\u003cp\u003eHeavy duty connectors from Harting, including Han B, Han D, Han Q, Han A, Han-Modular and Han HsB housings, frames and contacts. Contacts cover rated currents from 1 A to 40 A in the listed range. Stoklink ships worldwide from Turkey and quotes project volumes on request.\u003c\/p\u003e\n\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHan B surface bases and housings with single, central and double lever locking.\u003c\/li\u003e\n\u003cli\u003eHan-Modular hinged frames that hold several power, signal or pneumatic modules.\u003c\/li\u003e\n\u003cli\u003eHan D crimp contacts, male and female, in several conductor sizes.\u003c\/li\u003e\n\u003cli\u003eHan Q, Han A and Han HsB inserts and housings, plus D-Sub parts.\u003c\/li\u003e\n\u003cli\u003ePneumatic contacts with and without shut-off.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow to choose\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHousing size: choose by the number of contacts and modules, for example sizes 6B, 10B or 24B.\u003c\/li\u003e\n\u003cli\u003eContact type: crimp contacts need the right conductor cross-section and a matching crimp tool.\u003c\/li\u003e\n\u003cli\u003eLocking: single, central or double lever, set by the vibration and mating force.\u003c\/li\u003e\n\u003cli\u003eCable entry: PG or metric thread, for example PG29 or M32, to fit the gland.\u003c\/li\u003e\n\u003cli\u003eProtection degree: check the datasheet for the IP rating of the housing, such as IP65.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eCan I combine power, signal and data in one connector?\u003c\/h3\u003e\n\u003cp\u003eYes. Han-Modular frames take several module types side by side in one housing, so one connector can carry power, signal and pneumatic lines.\u003c\/p\u003e\n\u003ch3\u003eCan I fit any Han contact into any Han insert?\u003c\/h3\u003e\n\u003cp\u003eNo. Contact families are built for specific inserts. Check the insert and contact part numbers against the Harting datasheet.\u003c\/p\u003e\n\u003ch3\u003eDo you ship Harting parts internationally?\u003c\/h3\u003e\n\u003cp\u003eYes. Stoklink ships worldwide from Turkey under EXW terms. Lead time depends on availability, and bulk orders are quoted on request.\u003c\/p\u003e","products":[{"product_id":"harting-19200031440-han-a-hood-3a-m20","title":"Harting 19200031440 Han A Single-Lever Hood 3A Top Entry M20 Heavy Duty Connector Hood","description":"\u003cp\u003eThe Harting 19200031440 is a Han A hood in size 3 A, with a single locking lever and one top-entry M20 cable gland. The zinc die-cast shell is powder-coated RAL 7037 and rated IP44 as supplied, reaching IP65\/IP67 once the separate seal screw is fitted, for service from -40 to +125 °C.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArticle number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19200031440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArticle number (formatted)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 20 003 1440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHan A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5713140124585\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoods \/ Housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHood\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle locking lever\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTop entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of cable entries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable entry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x M20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNote\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeal screw ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of protection (IEC 60529)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP44 | IP65 with seal screw | IP67 with seal screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 50 \/ UL 50E type rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimiting temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +125 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial (housing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZinc die-cast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface finish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowder-coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRAL 7037 (dust grey)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61.4 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEuropean customs tariff number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85389099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL 1977\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eDNV GL\u003c\/li\u003e\n\u003cli\u003eEN 45545-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAs supplied this hood is only IP44 - order the seal screw separately if the installation needs the IP65\/IP67 rating, since it is not bundled with the hood. Top entry suits panels where the cable has to drop straight down into the gland rather than approach from the side, which is the main layout difference against the Han B hoods in this size range. Zinc die-cast construction is specific to the Han A series; it is lighter than the aluminium die-cast used on Han B but has the same -40 to +125 °C rating.\u003c\/p\u003e","brand":"Harting","offers":[{"title":"Default Title","offer_id":54090347872539,"sku":"19200031440","price":4.19,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/harting-19200031440-han-a-hood-3a-m20.jpg?v=1791033527"},{"product_id":"harting-19200031750-han-a-hood-coupler-3a-m20","title":"Harting 19200031750 Han A Single-Lever Hood Coupler 3A Top Entry M20 Heavy Duty Connector Hood","description":"\u003cp\u003eThe Harting 19200031750 is a Han A hood coupler, a cable-to-cable housing in size 3 A, with a single locking lever and one top-entry M20 cable gland. The zinc die-cast shell is powder-coated RAL 7037 and rated IP44 as supplied, reaching IP65\/IP67 once the separate seal screw is fitted.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArticle number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19200031750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArticle number (formatted)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 20 003 1750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHan A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5713140124639\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoods \/ Housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable to cable housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle locking lever\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTop entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of cable entries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable entry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x M20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNote\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeal screw ordered separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of protection (IEC 60529)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP44 | IP65 with seal screw | IP67 with seal screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 50 \/ UL 50E type rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimiting temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +125 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial (housing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZinc die-cast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface finish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowder-coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRAL 7037 (dust grey)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial (locking)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSteel, zinc plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL 1977\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eDNV GL\u003c\/li\u003e\n\u003cli\u003eEN 45545-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eA cable-to-cable housing couples two cable ends directly rather than mounting one side to a panel, which is what separates this part from the standard 3 A hood also offered in Han A. It still needs the same seal screw, ordered separately, to move past the as-supplied IP44 rating up to IP65\/IP67. The locking lever here is steel rather than the polycarbonate-and-stainless combination used on larger Han B hoods, matched to the smaller 3 A frame's lower mating force.\u003c\/p\u003e","brand":"Harting","offers":[{"title":"Default Title","offer_id":54090348462363,"sku":"19200031750","price":6.79,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/harting-19200031750-han-a-hood-coupler-3a-m20.jpg?v=1791033540"},{"product_id":"harting-19300100272-han-b-surface-base-10b-m32","title":"Harting 19300100272 Han B Double-Lever Surface Base 10B HC 2x M32 Heavy Duty Connector Housing","description":"\u003cp\u003eThe Harting 19300100272 is a Han B surface mounted housing in size 10 B, high construction, with a double Han-Easy Lock locking lever. Two M32 side entries bring cables in, and the aluminium die-cast body is sealed to IP65 with an NBR gasket, rated for continuous service from -40 to +125 °C.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArticle number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19300100272\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHan B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5713140125308\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoods \/ Housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurface mounted housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble locking lever\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHan-Easy Lock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSide entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of cable entries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable entry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x M32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of protection (IEC 60529)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 50 \/ UL 50E type rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 | 4X | 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimiting temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +125 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMating cycles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial (housing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAluminium die-cast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial (locking)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate (PC) | Stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRAL 7037 (dust grey)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial (seal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUL 1977\u003c\/li\u003e\n\u003cli\u003eCSA-C22.2 No. 182.3\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eDNV GL\u003c\/li\u003e\n\u003cli\u003eEN 45545-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe double lever on this 10 B base matches the double-lever 10 B hoods in the line - check lever count before pairing, since a single-lever hood will not latch onto this base. Two M32 entries suit metric gland stock already used elsewhere on the panel; choose the Pg 29 sibling base instead where the cable assembly already terminates in Pg thread. Han-Easy Lock keeps mating repeatable without tooling, which matters on a base handling many connect\/disconnect cycles.\u003c\/p\u003e","brand":"Harting","offers":[{"title":"Default Title","offer_id":54090349019419,"sku":"19300100272","price":22.37,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/harting-19300100272-han-b-surface-base-10b-m32.jpg?v=1791033551"},{"product_id":"harting-19300240282-han-b-surface-base-24b-m32","title":"Harting 19300240282 Han B Central-Lever Surface Base 24B HC 2x M32 IP65 Heavy Duty Connector Housing","description":"\u003cp\u003eThe Harting 19300240282 is a Han B surface mounted housing in size 24 B, rated IP65 and built in high construction for pairing with a central-locking-lever hood. Two M32 cable entries come in from the side face, and the aluminium die-cast body with an NBR seal is rated for continuous service from -40 to +125 °C.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArticle number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19300240282\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHan B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5713140126633\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoods \/ Housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurface mounted housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCentral locking lever (on the hood)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSide entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of cable entries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable entry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x M32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of protection (IEC 60529)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL 50 \/ UL 50E type rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 | 4X | 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLimiting temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +125 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMating cycles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥ 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial (housing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAluminium die-cast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface finish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePowder-coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRAL 7037 (dust grey)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial (seal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e426 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEuropean customs tariff number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85389099\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eDNV GL\u003c\/li\u003e\n\u003cli\u003eEN 45545-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis base takes a size 24 B Han B insert frame and pairs only with a matching central-locking-lever hood - a double-lever hood will not latch onto this base, so lever type has to match across the two halves. The two M32 side entries route both cables out from the same face, which helps in panel layouts where entry depth above the connector is tight. IP65 covers washdown-adjacent panel mounting; the double-lever PG-entry hood in the same frame size reaches IP66\/IP67 when fully sealed cable glands are needed instead of M32 fittings.\u003c\/p\u003e","brand":"Harting","offers":[{"title":"Default Title","offer_id":54090349773083,"sku":"19300240282","price":36.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/harting-19300240282-han-b-surface-base-24b.jpg?v=1791033562"}],"url":"https:\/\/stoklink.com\/collections\/heavy-duty-connectors.oembed","provider":"Stoklink","version":"1.0","type":"link"}