{"title":"Fuse Switch Disconnectors","description":"\u003cp\u003eFuse switch disconnectors from Mersen, Schneider Electric and ABB cover ratings from 20 A to 1600 A in 1-pole to 4-pole versions. The range holds over 320 products, including Mersen MULTIBLOC, MULTIVERT and ProGrid, and Schneider Electric FuPacT. Stoklink ships worldwide from Turkey on EXW terms, and quotes for project volumes are available on request.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMULTIBLOC NH Size 00 devices, 160 A, 690 VAC, for bottom fitting.\u003c\/li\u003e\n\u003cli\u003eMULTIVERT and i-Xtensio devices for NH Size 3, 630 A, 690 VAC.\u003c\/li\u003e\n\u003cli\u003eProGrid Size 1, 2 and 3 for busbar systems, up to 630 A at 690 V.\u003c\/li\u003e\n\u003cli\u003eLINOCUR D02 switch disconnectors for 63 A.\u003c\/li\u003e\n\u003cli\u003eFuPacT ISFT and ISFL fuse switch disconnectors, 160 A to 1250 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/fuse-switch-disconnector-accessories\"\u003eFuse Switch Disconnector Accessories\u003c\/a\u003e - busbar supports, labels and fitting sets.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNH size: Size 00 to Size 4 sets the maximum fuse current.\u003c\/li\u003e\n\u003cli\u003eRated current and voltage: choose the device at or above the fuse rating, for example 690 VAC or 800 VAC.\u003c\/li\u003e\n\u003cli\u003ePoles: 3-pole, 4-pole, or 3 x 1-pole for busbar-mounted designs.\u003c\/li\u003e\n\u003cli\u003eMounting: bottom fitting, DIN rail, or busbar system with 60, 100 or 185 mm spacing.\u003c\/li\u003e\n\u003cli\u003eStandard: IEC 60947-3 for switch disconnectors with fuses.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eWhat does a fuse switch disconnector do?\u003c\/h3\u003e\u003cp\u003eIt combines a load-break switch and fuse holder in one device. You isolate the circuit and protect it against short circuit.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between 1-pole and 3-pole switching?\u003c\/h3\u003e\u003cp\u003eA 3-pole device switches all phases together. A 3 x 1-pole device switches each phase separately and is often mounted on a busbar system.\u003c\/p\u003e\u003ch3\u003eCan you quote project quantities?\u003c\/h3\u003e\u003cp\u003eYes. Stoklink ships worldwide from Turkey on EXW terms, with quotes for project volumes.\u003c\/p\u003e","products":[{"product_id":"abb-1sca022719r0250-os400d03p-400a-3p-switch-fuse","title":"ABB 1SCA022719R0250 OS400D03P 3-Pole 400A DIN Mount Switch Fuse","description":"\u003cp\u003eThe ABB OS400D03P (SKU: 1SCA022719R0250) is a 3-pole, 400 A DIN-mounted switch fuse from the ABB OS400 series, engineered for reliable circuit isolation and overcurrent protection in demanding industrial power distribution applications. Compact yet robust, the OS400D03P combines switching and fuse protection in a single unit, simplifying panel design and reducing installation footprint with its DIN rail mounting configuration.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOS400D03P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA022719R0250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOS400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (Main Circuit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255 mm × 230 mm × 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019230627\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with European Union low-voltage and electromagnetic compatibility directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from restricted materials per EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e Switches, disconnectors, switch-disconnectors and fuse-combination units for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP rating classification)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Electrical systems for stationary fuel cell power systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-distribution boards in industrial facilities\u003c\/li\u003e\n\u003cli\u003eMachine and control panel circuit isolation and protection\u003c\/li\u003e\n\u003cli\u003eMotor feeder and branch circuit switch-fuse combinations\u003c\/li\u003e\n\u003cli\u003eBuilding services electrical distribution panels\u003c\/li\u003e\n\u003cli\u003eMarine and offshore power distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229249311003,"sku":"1SCA022719R0250","price":395.73,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022719r0250-os400d03p-mount-switch-fuse_a765039e-4b56-4bc2-add8-a77f8a604488.webp?v=1777157360"},{"product_id":"abb-1sca022825r4880-os800d03p-800a-3p-switch-fuse","title":"ABB 1SCA022825R4880 OS800D03P 3-Pole 800A DIN Mount Switch Fuse","description":"\u003cp\u003eThe ABB OS800D03P (SKU: 1SCA022825R4880) is a heavy-duty 3-pole 800A DIN-mounted switch fuse engineered for demanding industrial power distribution and circuit isolation applications. Designed to IEC 60947-3 standards, the OS800D03P provides reliable switching and overcurrent protection in a robust enclosure measuring 343mm × 306mm × 233mm and weighing 14.89 kg, making it well suited for large control panels and motor protection systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOS800D03P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA022825R4880\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019283647\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (Main Circuit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e343 mm × 306 mm × 233 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.89 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e Low-voltage switchgear and controlgear — switches, disconnectors, switch-disconnectors and fuse-combination units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP Code)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in potentially explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL Standard for electrical systems for stationary engine generator assemblies\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU regulation compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant with EU recycling requirements\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIndustrial power distribution boards and main switchgear panels\u003c\/li\u003e\n\u003cli\u003eMotor branch circuit protection and isolation up to 800 A\u003c\/li\u003e\n\u003cli\u003eHazardous area installations requiring ATEX-rated switching devices\u003c\/li\u003e\n\u003cli\u003eHeavy industrial machinery and process plant electrical control panels\u003c\/li\u003e\n\u003cli\u003eGenerator and transformer feeder protection in commercial and industrial facilities\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229249376539,"sku":"1SCA022825R4880","price":783.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022825r4880-os800d03p-mount-switch-fuse_7fa5291c-9195-4f29-812d-d38a9699ce9b.webp?v=1777157446"},{"product_id":"abb-1sca022719r0090-os250d03p-250a-3p-switch-fuse","title":"ABB 1SCA022719R0090 OS250D03P 3-Pole 250A DIN Mount Switch Fuse","description":"\u003cp\u003eThe ABB OS250D03P switch fuse (SKU: 1SCA022719R0090) is a heavy-duty 3-pole, 250 A DIN-mounted switch fuse from ABB's OS250 series, engineered for safe isolation and overcurrent protection in industrial control panels and distribution boards. Combining switching and fuse protection in a single compact unit, the OS250D03P delivers reliable circuit isolation in demanding environments including hazardous areas rated for ATEX compliance.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOS250D03P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA022719R0090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOS250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (Main Circuit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208 mm × 193 mm × 154 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019230580\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e Compliant with the international standard for switches, disconnectors, switch-disconnectors and fuse combination units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Approved for use in explosive atmospheres — suitable for hazardous area installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Meets European Union safety, health, and environmental protection requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Listed under UL safety standard for electrical component assemblies\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for market access in China\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive — free from restricted materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-circuit isolation in industrial control panels and switchgear assemblies\u003c\/li\u003e\n\u003cli\u003eMotor feeder protection and disconnection in manufacturing and process automation\u003c\/li\u003e\n\u003cli\u003eDistribution board protection in commercial and heavy industrial facilities\u003c\/li\u003e\n\u003cli\u003eHazardous area installations requiring ATEX-rated switch fuse units\u003c\/li\u003e\n\u003cli\u003eOEM machine builders requiring DIN-rail mountable overcurrent and isolation devices rated to 250 A\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229249442075,"sku":"1SCA022719R0090","price":261.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022719r0090-os250d03p-mount-switch-fuse_01679b45-79ca-4261-a2e5-43d60451ac24.webp?v=1777157355"},{"product_id":"abb-1sca115643r1001-os160gd12p-160a-3p-switch-disconnector-fuse","title":"ABB 1SCA115643R1001 OS160GD12P 3-Pole 160A DIN Mount Switch-Disconnector Fuse","description":"\u003cp\u003eThe ABB OS160GD12P (SKU 1SCA115643R1001) is a 3-pole 160A switch-disconnector fuse from the ABB OS series, designed for DIN rail mounting in industrial control panels and power distribution assemblies. Combining the functions of a load-break switch and fuse holder in a single compact unit, the OS160GD12P provides reliable circuit isolation and overcurrent protection in one device — ideal for motor feeders, distribution boards, and machine control applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOS160GD12P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA115643R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-Disconnector Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e147 mm × 140 mm × 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019479811\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e International standard for switches, disconnectors, switch-disconnectors and fuse-combination units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with applicable European Union directives for market placement\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in potentially explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL certification applicable to this product\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e European RoHS directive compliance confirmed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e Compliant with the 2015 amendment extending RoHS substance restrictions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive — registered for proper end-of-life recycling\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor feeder circuits requiring combined switching and fuse protection\u003c\/li\u003e\n\u003cli\u003eIndustrial control panel power distribution up to 160A\u003c\/li\u003e\n\u003cli\u003eMachine tool and automation system main disconnects\u003c\/li\u003e\n\u003cli\u003eHazardous area installations (ATEX-rated environments)\u003c\/li\u003e\n\u003cli\u003eDIN rail-based switchgear assemblies and distribution boards\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229249507611,"sku":"1SCA115643R1001","price":174.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca115643r1001-os160gd12p-mount-switch-disconnector-fuse_a6ad67fe-2be3-48e4-a61c-baef37bab6e8.webp?v=1777157717"},{"product_id":"abb-1sca115641r1001-os125gd12p-125a-3p-switch-disconnector-fuse","title":"ABB 1SCA115641R1001 OS125GD12P 3-Pole 125A DIN Mount Switch-Disconnector Fuse","description":"\u003cp\u003eThe ABB OS125GD12P (SKU: 1SCA115641R1001) is a 3-pole, 125A switch-disconnector fuse from ABB's OS Series, designed for reliable isolation and overcurrent protection in industrial control panels and distribution boards. Featuring DIN rail mounting and compact dimensions of 147 mm × 140 mm × 130 mm, the OS125GD12P delivers safe disconnection of circuits in demanding industrial environments. Compliant with IEC 60947-3 and certified for ATEX hazardous-area applications, this unit suits a broad range of automation and power distribution installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOS125GD12P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA115641R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-Disconnector Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e147 mm × 140 mm × 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019479798\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e Low-voltage switchgear and controlgear — switches, disconnectors, switch-disconnectors and fuse-combination units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in potentially explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e EU Directive 2011\/65\/EU — restriction of hazardous substances in electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2015\/863:\u003c\/strong\u003e Amendment to RoHS Directive 2011\/65\/EU, extending the list of restricted substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL certification for electrical construction equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for market access in China\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e EU Directive on waste electrical and electronic equipment — compliant with end-of-life recycling requirements\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIsolation and protection of motor feeders and distribution circuits in industrial control panels\u003c\/li\u003e\n\u003cli\u003eSafe disconnection of equipment during maintenance in manufacturing and process plants\u003c\/li\u003e\n\u003cli\u003eHazardous-area installations requiring ATEX-rated switching devices\u003c\/li\u003e\n\u003cli\u003eMain or branch circuit switching in DIN-rail-based distribution boards\u003c\/li\u003e\n\u003cli\u003eIndustrial automation systems requiring IEC 60947-3 compliant switch-disconnectors\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229249802523,"sku":"1SCA115641R1001","price":154.69,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca115641r1001-os125gd12p-mount-switch-disconnector-fuse_659f5e1b-f8da-49b7-b800-cbb025151542.webp?v=1777157712"},{"product_id":"abb-1sca115227r1001-os63gd12p-63a-3p-fuse-switch-disconnector","title":"ABB 1SCA115227R1001 OS63GD12P 63A 3-Pole Base Mount Fuse Switch Disconnector","description":"\u003cp\u003eThe ABB OS63GD12P (SKU: 1SCA115227R1001) is a 63A 3-pole base-mounted fuse switch disconnector designed for safe isolation and overcurrent protection in industrial control panels and distribution boards. Combining the switching function of a disconnector with integrated fuse protection, the OS63GD12P provides reliable circuit isolation and short-circuit protection in a compact 112 × 125 × 121 mm footprint weighing just 1.3 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOS63GD12P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA115227R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse Switch Disconnector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e112 mm × 125 mm × 121 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019476520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e Compliant with the IEC standard for disconnectors, switch-disconnectors and fuse-combination units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Meets European conformity requirements for electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Approved for use in potentially explosive atmospheres\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL-listed for relevant safety standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Directive 2011\/65\/EU on restriction of hazardous substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e RoHS directive compliance for electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e Compliant with the 2015 RoHS amendment extending restricted substance requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment directive for proper end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMotor circuit isolation and protection in industrial machinery\u003c\/li\u003e\n\u003cli\u003eMain and sub-distribution boards in commercial and industrial facilities\u003c\/li\u003e\n\u003cli\u003eControl panel feeder circuits requiring fused disconnection\u003c\/li\u003e\n\u003cli\u003eHazardous area installations where ATEX compliance is mandatory\u003c\/li\u003e\n\u003cli\u003eMachine tool and automation system power distribution\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229249868059,"sku":"1SCA115227R1001","price":148.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca115227r1001-os63gd12p-fuse-switch-disconnector_a41e8b68-0847-49d1-af05-9b41ee81d968.webp?v=1777157706"},{"product_id":"abb-1sca022825r2830-os630d03p-630a-3p-switch-fuse","title":"ABB 1SCA022825R2830 OS630D03P 3-Pole 630A DIN Mount Switch Fuse","description":"\u003cp\u003eThe ABB OS630D03P (SKU: 1SCA022825R2830) is a 3-pole, 630 A DIN-mounted switch fuse from ABB's OS Series, engineered for reliable isolation and overcurrent protection in demanding industrial power distribution applications. Combining robust fuse-based protection with a load-break disconnect function, the OS630D03P delivers safe, code-compliant switching for main incomer panels, sub-distribution boards, and industrial control systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOS630D03P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA022825R2830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (Main Circuit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e343 mm × 306 mm × 233 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019283432\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with applicable European Union directives for electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e Meets the international standard for low-voltage switchgear and controlgear — switches, disconnectors, switch-disconnectors and fuse-combination units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Verified ingress protection rating per international standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant — free from restricted substances per EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC) No 1907\/2006 on chemical substance safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Approved for use in potentially explosive atmospheres per ATEX directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification — approved for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Listed to UL standard for electrical systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive for responsible end-of-life recycling\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain incomer and sub-distribution boards in industrial facilities\u003c\/li\u003e\n\u003cli\u003eMotor feeders and machine control panels requiring fuse-protected isolation\u003c\/li\u003e\u0026lt; li\u0026gt;Power distribution in hazardous (ATEX-rated) environments\u003cli\u003eBuilding services, data centres, and process plants requiring 630 A fused switching\u003c\/li\u003e\n\u003cli\u003eApplications demanding full IEC 60947-3 compliance with DIN-rail installation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229249933595,"sku":"1SCA022825R2830","price":609.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca022825r2830-os630d03p-mount-switch-fuse_e32445dd-8561-44fd-ac06-3b340a634841.webp?v=1777157441"},{"product_id":"abb-1sep101890r0002-xlp00-6bc-160a-3p-fuse-switch-disconnector","title":"ABB 1SEP101890R0002 XLP00-6BC EasyLine 3-Pole 160A Baseplate Fuse Switch Disconnector","description":"\u003cp\u003eThe ABB XLP00-6BC (SKU: 1SEP101890R0002) is a 3-pole 160A fuse switch disconnector from the EasyLine series, designed for reliable circuit isolation and overcurrent protection in industrial control panels and distribution boards. Mounted via baseplate, the XLP00-6BC provides safe, code-compliant disconnection in demanding industrial environments, combining switching and fusing functions in a compact 105mm × 187mm × 90mm footprint weighing just 0.57 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXLP00-6BC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SEP101890R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse Switch Disconnector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBaseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 mm × 187 mm × 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.57 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7025840013402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive, ensuring the product is free from restricted materials.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on the registration, evaluation and authorisation of chemicals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3 \/ GB\/T 14048.3:\u003c\/strong\u003e Designed and tested in accordance with the international and Chinese national standard for disconnectors, switch-disconnectors and fuse-combination units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Meets the broader IEC 60947 series of standards for low-voltage switchgear and controlgear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555-94:\u003c\/strong\u003e Conforms to the general methods for the assessment of the ability of electrical and electronic products to be repaired, reused and recycled.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal and recycling.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIndustrial control panels requiring safe, visible isolation of circuits up to 160A.\u003c\/li\u003e\n\u003cli\u003eDistribution boards in manufacturing, process automation, and building services installations.\u003c\/li\u003e\n\u003cli\u003eMotor feeder protection where combined switching and fusing in a single device is required.\u003c\/li\u003e\n\u003cli\u003eMachine builder panels where compact, baseplate-mounted fuse switch disconnectors are specified.\u003c\/li\u003e\n\u003cli\u003eAny application demanding IEC 60947-3 compliant switch-disconnector performance with integrated fuse protection.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229250162971,"sku":"1SEP101890R0002","price":45.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sep101890r0002-xlp00-6bc-fuse-switch-disconnector_097807ca-e80f-437e-9f60-c3423559ca38.webp?v=1777159468"},{"product_id":"abb-1sep201428r0002-xlp000-6cc-in-carton-fuse-switch-disconnector","title":"ABB 1SEP201428R0002 XLP000-6CC in carton 3P 100A Fuse Switch Disconnector EasyLine Baseplate Mount","description":"\u003cp\u003eThe ABB XLP000-6CC in carton (SKU 1SEP201428R0002) is a 3-pole, 100 A EasyLine series Fuse Switch Disconnector designed for reliable isolation and overcurrent protection in industrial control panels and power distribution systems. Featuring a compact baseplate mounting design measuring 95 × 82 × 160 mm and weighing only 0.49 kg, this unit combines safe disconnection with fuse protection in a single, space-saving device fully compliant with IEC 60947-3 and IEC 60947 standards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXLP000-6CC in carton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SEP201428R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXLP000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse Switch Disconnector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBaseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 × 82 × 160 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.49 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7025840014584\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the EU Restriction of Hazardous Substances Directive, confirming the product is free from prohibited substances.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (Registration, Evaluation, Authorisation and Restriction of Chemicals), ensuring safe material composition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3 \/ GB\/T 14048.3:\u003c\/strong\u003e Meets the international and Chinese national standard for low-voltage switchgear — disconnectors, switch-disconnectors, and fuse-combination units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Designed and tested in accordance with the IEC 60947 series of low-voltage switchgear and controlgear standards.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and branch circuit isolation in industrial control panels and motor control centres (MCCs)\u003c\/li\u003e\n\u003cli\u003eOvercurrent and short-circuit protection combined with safe disconnection in manufacturing and process automation equipment\u003c\/li\u003e\n\u003cli\u003ePower distribution boards requiring compact, baseplate-mounted fuse switch disconnectors rated up to 100 A\u003c\/li\u003e\n\u003cli\u003eMachine tool, HVAC, and pump drive panels requiring IEC 60947-3 compliant isolation devices\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229250228507,"sku":"1SEP201428R0002","price":39.83,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sep201428r0002-xlp000-6cc-in-carton-easyline-baseplate-mount_01426dda-ee39-4ddb-8a52-6a35e05c0885.jpg?v=1777159486"},{"product_id":"abb-1sca105475r1001-os1250d03p-1250a-3p-switch-disconnector-fuse","title":"ABB 1SCA105475R1001 OS1250D03P 3-Pole 1250A Base Mount Switch-Disconnector Fuse","description":"\u003cp\u003eThe ABB OS1250D03P (SKU: 1SCA105475R1001) is a heavy-duty 3-pole, 1250A switch-disconnector fuse from ABB's OS series, designed for safe isolation and fuse protection of power distribution circuits in industrial installations. Engineered for base mounting and compliant with IEC 60947-3, the OS1250D03P provides reliable load isolation and overcurrent protection in demanding control panel and switchgear environments. With a robust steel enclosure rated at 27.86 kg and overall dimensions of 429 × 356 × 366 mm, this unit is built for high-current industrial applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOS1250D03P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA105475R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-Disconnector Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e429 mm × 356 mm × 366 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.86 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019394206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3:\u003c\/strong\u003e International standard for switch-disconnectors, disconnectors, switch-fuse combinations and fuse-combination units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60529:\u003c\/strong\u003e Degrees of protection provided by enclosures (IP Code)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Certified for use in potentially explosive atmospheres (EU Directive 2014\/34\/EU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCCC:\u003c\/strong\u003e China Compulsory Certification for the Chinese market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e UL standard compliance for electrical systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain switch isolation in industrial power distribution panels and switchgear assemblies\u003c\/li\u003e\n\u003cli\u003eFused disconnection of high-current feeders supplying motors, transformers, and distribution busbars\u003c\/li\u003e\n\u003cli\u003eSafe maintenance isolation in manufacturing plants, process industries, and utility substations\u003c\/li\u003e\n\u003cli\u003eApplications requiring ATEX certification in hazardous area installations\u003c\/li\u003e\n\u003cli\u003eHeavy-duty industrial automation and control panel builds requiring IEC 60947-3 compliant disconnection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229250752795,"sku":"1SCA105475R1001","price":1570.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca105475r1001-os1250d03p-mount-switch-disconnector-fuse_f3cbf2d5-c0e8-4b29-8b27-30287b1c2018.webp?v=1777157659"},{"product_id":"abb-1sep101892r0002-xlp2-6bc-400a-fuse-switch-disconnector","title":"ABB 1SEP101892R0002 XLP2-6BC 3-Pole 400A Baseplate Mount EasyLine Fuse Switch Disconnector","description":"\u003cp\u003eThe ABB XLP2-6BC (SKU: 1SEP101892R0002) is a 3-pole, 400A fuse switch disconnector from the ABB EasyLine series, designed for safe isolation and overcurrent protection in industrial power distribution panels. Baseplate-mounted and compliant with IEC 60947-3 and GB\/T14048.3 standards, the XLP2-6BC delivers reliable circuit isolation for demanding industrial environments. With compact dimensions of 210 mm × 290 mm × 130 mm and a weight of just 3.02 kg, it is well-suited for space-constrained control panel installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXLP2-6BC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SEP101892R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse Switch Disconnector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBaseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm × 290 mm × 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.02 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7025840016878\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with EU safety, health, and environmental protection requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — EU Directive 2011\/65\/EU compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e RoHS2 directive compliance for restricted hazardous substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover resources from electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3 \/ GB\/T14048.3:\u003c\/strong\u003e International and Chinese national standard for switches, disconnectors, switch-disconnectors, and fuse-combination units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear — international compliance standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — product registered for proper end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIndustrial power distribution boards and motor control centres (MCCs)\u003c\/li\u003e\n\u003cli\u003eSafe isolation of downstream circuits during maintenance operations\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection in combination with fuse elements in 3-phase systems up to 400 A\u003c\/li\u003e\n\u003cli\u003eControl panel installations requiring baseplate-mounted disconnectors\u003c\/li\u003e\n\u003cli\u003eManufacturing, process automation, and building services electrical infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229250916635,"sku":"1SEP101892R0002","price":195.88,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sep101892r0002-xlp2-6bc-fuse-switch-disconnector_d9581801-658a-4c56-a150-2b4a7da3d33b.jpg?v=1777159478"},{"product_id":"abb-1sep101891r0002-xlp1-6bc-250a-3p-fuse-switch-disconnector","title":"ABB 1SEP101891R0002 XLP1-6BC 3-Pole 250A Baseplate Mount EasyLine XLP Fuse Switch Disconnector","description":"\u003cp\u003eThe ABB XLP1-6BC (SKU: 1SEP101891R0002) is a 3-pole, 250A fuse switch disconnector from the EasyLine XLP series, designed for reliable circuit isolation and overcurrent protection in industrial control panels. Combining switching and fuse protection in a single compact unit, the XLP1-6BC offers baseplate mounting and a robust build measuring 185 mm × 270 mm × 116 mm at just 1.83 kg, making it well-suited for high-density switchgear installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXLP1-6BC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SEP101891R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLine XLP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXLP1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse Switch Disconnector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBaseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185 mm × 270 mm × 116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.83 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7025840013730\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive, ensuring environmentally responsible material composition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation for chemical substance safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3 \/ GB\/T 14048.3:\u003c\/strong\u003e Meets international and Chinese national standards for disconnectors, switch-disconnectors, and fuse-combination units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Compliant with the broader IEC low-voltage switchgear and controlgear standard series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain or sub-circuit isolation in industrial control panels and switchboards\u003c\/li\u003e\n\u003cli\u003eOvercurrent and short-circuit protection with integrated fuse functionality in motor feeders\u003c\/li\u003e\n\u003cli\u003eBaseplate-mounted installations in manufacturing, utilities, and infrastructure facilities\u003c\/li\u003e\n\u003cli\u003eDistribution board protection where combined switching and fusing in a compact footprint is required\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229251211547,"sku":"1SEP101891R0002","price":110.74,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sep101891r0002-xlp1-6bc-fuse-switch-disconnector_3e27d623-7283-4d22-a3ed-e7edd1044e39.webp?v=1777159474"},{"product_id":"abb-1sep600113r0002-xlp00-1p-2bc-160a-fuse-switch-disconnector","title":"ABB 1SEP600113R0002 XLP00-1P-2BC 1P 160A EasyLine Fuse Switch Disconnector Baseplate Mount","description":"\u003cp\u003eThe ABB XLP00-1P-2BC (SKU: 1SEP600113R0002) is a 1-pole 160A fuse switch disconnector from the EasyLine XLP series, designed for safe isolation and overcurrent protection in industrial control panels. The XLP00-1P-2BC features a compact baseplate-mounting design measuring 40 × 88 × 185 mm, making it ideal for space-constrained enclosures. Compliant with IEC 60947-3 and CE certified, this unit delivers reliable fusegear performance for industrial automation and power distribution applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXLP00-1P-2BC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SEP600113R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLine XLP\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7025840086499\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse Switch Disconnector\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBaseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 × 88 × 185 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU low-voltage and electromagnetic compatibility directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU REACH regulation compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-3 \/ GB\/T 14048.3:\u003c\/strong\u003e International and Chinese national standard for switches, disconnectors, and fuse-combination units\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear international standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — correctly classified for end-of-life recycling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIndustrial control panels requiring safe fused isolation of single-phase circuits up to 160 A\u003c\/li\u003e\n  \u003cli\u003eMotor branch circuit protection in manufacturing and process automation environments\u003c\/li\u003e\n  \u003cli\u003ePower distribution boards where compact baseplate-mounted fusegear is required\u003c\/li\u003e\n  \u003cli\u003eMachine building applications demanding IEC 60947-3 compliant disconnection means\u003c\/li\u003e\n  \u003cli\u003eMaintenance isolation points in industrial automation and control systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229251277083,"sku":"1SEP600113R0002","price":26.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sep600113r0002-xlp00-1p-2bc-disconnector-baseplate-mount_e4e7238b-f7da-4cca-ac0b-797191b43550.webp?v=1777159491"},{"product_id":"abb-1sep101975r0002-xlp3-6bc-630a-3p-fuse-switch-disconnector","title":"ABB 1SEP101975R0002 XLP3-6BC 3-Pole 630A Baseplate Mount EasyLine Fuse Switch Disconnector","description":"\u003cp\u003eThe ABB XLP3-6BC fuse switch disconnector (SKU: 1SEP101975R0002) is a heavy-duty 3-pole, 630 A EasyLine series unit designed for reliable isolation and overcurrent protection in industrial power distribution panels. Engineered for baseplate mounting, the XLP3-6BC combines fuse protection and switching function in a single compact device measuring 250 mm × 330 mm × 142 mm — ideal for motor control centres, main distribution boards, and industrial automation installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXLP3-6BC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SEP101975R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse Switch Disconnector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBaseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 mm × 330 mm × 142 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7025840016991\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with European Union directives for electrical safety and electromagnetic compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from restricted materials per EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances (EC No 1907\/2006)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3 \/ GB\/T 14048.3:\u003c\/strong\u003e Meets international and Chinese national standards for switches, disconnectors, and fuse-combination units for low-voltage switchgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Designed and tested to the full IEC 60947 series for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMain and sub-main distribution boards in industrial facilities\u003c\/li\u003e\n\u003cli\u003eMotor control centres (MCC) requiring fused isolation up to 630 A\u003c\/li\u003e\n\u003cli\u003ePower distribution panels in manufacturing, process, and infrastructure applications\u003c\/li\u003e\n\u003cli\u003eIsolation and overcurrent protection in control panels for industrial automation systems\u003c\/li\u003e\n\u003cli\u003eIncoming protection for large machinery and HVAC equipment\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229251342619,"sku":"1SEP101975R0002","price":271.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sep101975r0002-xlp3-6bc-fuse-switch-disconnector_28e5b1ff-a6d2-449d-9b5f-5f1da0463054.jpg?v=1777159482"},{"product_id":"abb-1sep600115r0002-xlp00-4p-8bc-160a-4p-fuse-switch-disconnector","title":"ABB 1SEP600115R0002 XLP00-4P-8BC 4-Pole 160A Baseplate EasyLine XLP Fuse Switch Disconnector","description":"\u003cp\u003eThe ABB XLP00-4P-8BC fuse switch disconnector (SKU 1SEP600115R0002) is a 4-pole, 160 A baseplate-mount switching and isolation device from the EasyLine XLP series, engineered for reliable circuit protection and safe isolation in industrial control panels and distribution boards. Rated at 3.5 W at full load, it combines fuse protection with a disconnector function in a compact 145 × 185 × 88 mm (W × D × H) form factor weighing just 0.99 kg — making XLP00-4P-8BC an efficient choice for space-constrained installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXLP00-4P-8BC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SEP600115R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEasyLine XLP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse Switch Disconnector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBaseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower at Rated Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × D × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e145 × 185 × 88 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.99 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7025840086550\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with REACH chemical safety regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863:\u003c\/strong\u003e Fully compliant with EU RoHS legislation and its amendment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-3 \/ GB\/T 14048.3:\u003c\/strong\u003e Tested and rated to international standard for switches, disconnectors, switch-disconnectors and fuse-combination units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Compliant with the IEC low-voltage switchgear and controlgear standard series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Meets European conformity requirements for the EU market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive for responsible end-of-life recycling\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229251604763,"sku":"1SEP600115R0002","price":66.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sep600115r0002-xlp00-4p-8bc-fuse-switch-disconnector_23d91d57-2b79-4a69-a740-52cf8dc2946e.webp?v=1777159496"},{"product_id":"schneider-electric-lv480750-isft100n-fuse-switch","title":"Schneider Electric LV480750 Fupact ISFT100N 3P 100 A NH000 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV480750 is a three-pole Fupact ISFT100N fuse-switch disconnector rated 100 A at 690 V AC for AC-21B duty, sized for NH000 fuse links and built for backplate mounting with cable connectors, upstream and downstream, 2.5–50 mm². It carries a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses and a 3.6 kA for 1 s short-time withstand rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISFT100N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 fuse carriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A at 40 °C (9 W per fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20); 440 V DC (800 V DC DC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] \/ [Uimp] insulation \/ impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC \/ 1000 V DC \/ 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A, AC-21B and AC-22B, 220–690 V AC; 100 A, DC-21B and DC-22B, 220–440 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.6 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making\/breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.2 kA at 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse carriers handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ tightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable connectors, upstream and downstream, 2.5–50 mm² (4.5 N.m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D) \/ net weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e53 mm x 216 mm x 80 mm \/ 0.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP3x front face (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-1, IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LV480750 is a fixed, non-switchable ISFT100N disconnector rated 100 A, sized for NH000 fuse links and a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses installed. Pick the backplate version over the other ISFT100N mounting variants in this range when it matches the busbar or cable connection already used in the panel.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229766226203,"sku":"LV480750","price":79.09,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480750-isft100n-fuse-switch-disconnector.jpg?v=1790869167"},{"product_id":"schneider-electric-lv480751-isft100n-fuse-switch","title":"Schneider Electric LV480751 Fupact ISFT100N 3P 100 A NH000 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV480751 is a three-pole Fupact ISFT100N fuse-switch disconnector rated 100 A at 690 V AC for AC-21B duty, sized for NH000 fuse links and built for 60 mm busbar, upstream mounting with cable connectors, upstream only, 2.5–50 mm². It carries a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses and a 3.6 kA for 1 s short-time withstand rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480751\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISFT100N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 fuse carriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A at 40 °C (9 W per fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20); 440 V DC (800 V DC DC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] \/ [Uimp] insulation \/ impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC \/ 1000 V DC \/ 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A, AC-21B and AC-22B, 220–690 V AC; 100 A, DC-21B and DC-22B, 220–440 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.6 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making\/breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.2 kA at 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse carriers handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbars, 60 mm, top cable entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ tightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable connectors, upstream only, 2.5–50 mm² (4.5 N.m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D) \/ net weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e53 mm x 216 mm x 80 mm \/ 0.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP3x front face (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-1, IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LV480751 is a fixed, non-switchable ISFT100N disconnector rated 100 A, sized for NH000 fuse links and a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses installed. Pick the 60 mm busbar, upstream version over the other ISFT100N mounting variants in this range when it matches the busbar or cable connection already used in the panel.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229766652187,"sku":"LV480751","price":94.05,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480751-isft100n-fuse-switch-disconnector.jpg?v=1790869177"},{"product_id":"schneider-electric-lv480752-isft100n-fuse-switch","title":"Schneider Electric LV480752 Fupact ISFT100N 3P 100 A NH000 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV480752 is a three-pole Fupact ISFT100N fuse-switch disconnector rated 100 A at 690 V AC for AC-21B duty, sized for NH000 fuse links and built for 60 mm busbar, downstream mounting with cable connectors, downstream only, 2.5–50 mm². It carries a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses and a 3.6 kA for 1 s short-time withstand rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480752\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISFT100N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 fuse carriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A at 40 °C (9 W per fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20); 440 V DC (800 V DC DC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] \/ [Uimp] insulation \/ impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC \/ 1000 V DC \/ 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A, AC-21B and AC-22B, 220–690 V AC; 100 A, DC-21B and DC-22B, 220–440 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.6 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making\/breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.2 kA at 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse carriers handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbars, 60 mm, bottom cable entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ tightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable connectors, downstream only, 2.5–50 mm² (4.5 N.m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D) \/ net weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e53 mm x 216 mm x 80 mm \/ 0.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP3x front face (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-1, IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LV480752 is a fixed, non-switchable ISFT100N disconnector rated 100 A, sized for NH000 fuse links and a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses installed. Pick the 60 mm busbar, downstream version over the other ISFT100N mounting variants in this range when it matches the busbar or cable connection already used in the panel.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229766979867,"sku":"LV480752","price":90.2,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480752-isft100n-fuse-switch-disconnector.jpg?v=1790869186"},{"product_id":"schneider-lv480800-isft160-3p-100a-fuse-switch-disconnector","title":"Schneider Electric LV480800 ISFT160 3-Pole 100A Fuse Switch Disconnector FUPACT ISFT100 Series","description":"\u003cp\u003eThe Schneider Electric LV480800 ISFT160 is a 3-pole 100A fuse switch disconnector from the FUPACT ISFT100 series, designed to provide reliable circuit isolation and overcurrent protection in industrial control panels and distribution boards. Combining switching and fusing functions in a single compact unit, the ISFT160 simplifies panel design and ensures safe maintenance isolation with backplate mounting for secure installation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISFT160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFUPACT ISFT100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse Switch Disconnector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplate mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229767307547,"sku":"LV480800","price":72.17,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480800-fupact-isft100-series_10393fa1-81e9-4091-be8a-b38685fedb66.jpg?v=1777166531"},{"product_id":"schneider-electric-lv480801-isft160-fuse-switch-disconnector","title":"Schneider Electric LV480801 Fupact ISFT160 3P 160 A NH00 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV480801 is a three-pole Fupact ISFT160 fuse-switch disconnector rated 160 A at 690 V AC for AC-21B duty, sized for NH00 fuse links and built for backplate mounting with m8 terminals. It carries a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses and a 5 kA for 1 s short-time withstand rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480801\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISFT160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 fuse carriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A at 40 °C (12 W per fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20); 440 V DC (800 V DC DC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] \/ [Uimp] insulation \/ impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC \/ 1000 V DC \/ 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A, AC-21B and AC-22B, 220–690 V AC; 160 A DC-21B at 220 V DC, 125 A DC-21B at 440 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making\/breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.65 kA at 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse carriers handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ tightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM8 terminals (5 N.m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D) \/ net weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e106 mm x 206 mm x 80 mm \/ 0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP3x front face (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-1, IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LV480801 is a fixed, non-switchable ISFT160 disconnector rated 160 A, sized for NH00 fuse links and a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses installed. Pick the backplate version over the other ISFT160 mounting variants in this range when it matches the busbar or cable connection already used in the panel.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229767667995,"sku":"LV480801","price":64.13,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480801-isft160-fuse-switch-disconnector.jpg?v=1790869196"},{"product_id":"schneider-lv480802-isft160-160a-3p-fuse-switch-disconnector","title":"Schneider Electric LV480802 ISFT160 3-Pole 160A Fupact Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV480802 ISFT160 is a 3-pole 160 A fuse switch disconnector from the Fupact ISFT160 series, designed for reliable circuit isolation and overcurrent protection in industrial control panels and distribution boards. Combining switching and fuse protection in a single compact unit, the LV480802 simplifies panel design while delivering robust performance for demanding industrial automation environments. Its backplate mounting configuration ensures straightforward installation in enclosures and switchgear assemblies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISFT160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFupact ISFT160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse Switch Disconnector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplate Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Control Panels:\u003c\/strong\u003e Provides combined fuse protection and disconnection for motor circuits, distribution panels, and machine control enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistribution Boards:\u003c\/strong\u003e Acts as a safe isolation point for downstream equipment during maintenance or fault conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Suitable for factory automation systems requiring reliable, compact overcurrent protection and load disconnection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFusegear Assemblies:\u003c\/strong\u003e Integrates into fusegear switchboards where space-saving, multi-function switching and protection is required.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229768028443,"sku":"LV480802","price":77.15,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480802-fuse-switch-disconnector_30a190d1-751e-40bd-85b3-e08ed7d67677.jpg?v=1777166535"},{"product_id":"schneider-electric-lv480803-isft160-fuse-switch-disconnector","title":"Schneider Electric LV480803 Fupact ISFT160 3P 160 A NH00 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV480803 is a three-pole Fupact ISFT160 fuse-switch disconnector rated 160 A at 690 V AC for AC-21B duty, sized for NH00 fuse links and built for 60 mm busbar, turnable hook mounting with m10 terminals. It carries a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses and a 5 kA for 1 s short-time withstand rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480803\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISFT160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 fuse carriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A at 40 °C (12 W per fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20); 440 V DC (800 V DC DC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] \/ [Uimp] insulation \/ impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC \/ 1000 V DC \/ 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A, AC-21B and AC-22B, 220–690 V AC; 160 A DC-21B at 220 V DC, 125 A DC-21B at 440 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making\/breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.65 kA at 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse carriers handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbars, 60 mm, turnable hook\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ tightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM10 terminals (6 N.m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D) \/ net weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e106 mm x 206 mm x 80 mm \/ 0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP3x front face (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-1, IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LV480803 is a fixed, non-switchable ISFT160 disconnector rated 160 A, sized for NH00 fuse links and a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses installed. Pick the 60 mm busbar, turnable hook version over the other ISFT160 mounting variants in this range when it matches the busbar or cable connection already used in the panel.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229768323355,"sku":"LV480803","price":129.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480803-isft160-fuse-switch-disconnector.jpg?v=1790869207"},{"product_id":"schneider-electric-lv480804-isft250-fuse-switch-disconnector","title":"Schneider Electric LV480804 Fupact ISFT250 3P 250 A NH1 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV480804 is a three-pole Fupact ISFT250 fuse-switch disconnector rated 250 A at 690 V AC for AC-21B duty, sized for NH1 fuse links and built for backplate mounting with m10 terminals. It carries a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses and a 8.6 kA for 1 s short-time withstand rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480804\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISFT250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 fuse carriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 40 °C (23 W per fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20); 440 V DC (800 V DC DC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] \/ [Uimp] insulation \/ impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC \/ 1000 V DC \/ 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A, AC-21B, 220–690 V AC; 250 A, AC-22B, up to 690 V AC; 250 A DC-21B\/DC-22B at 220–440 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.6 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making\/breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.6 kA at 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse carriers handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ tightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM10 terminals (12 N.m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D) \/ net weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e184 mm x 306 mm x 110 mm \/ 2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP3x front face (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-1, IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LV480804 is a fixed, non-switchable ISFT250 disconnector rated 250 A, sized for NH1 fuse links and a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses installed. Pick the backplate version over the other ISFT250 mounting variants in this range when it matches the busbar or cable connection already used in the panel.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229768651035,"sku":"LV480804","price":168.85,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480804-isft250-fuse-switch-disconnector.jpg?v=1790869215"},{"product_id":"schneider-electric-lv480805-isft250-fuse-switch-disconnector","title":"Schneider Electric LV480805 Fupact ISFT250 3P 250 A NH1 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV480805 is a three-pole Fupact ISFT250 fuse-switch disconnector rated 250 A at 690 V AC for AC-21B duty, sized for NH1 fuse links and built for 60 mm busbar, turnable hook mounting with m10 terminals. It carries a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses and a 8.6 kA for 1 s short-time withstand rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480805\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISFT250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 fuse carriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 40 °C (23 W per fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20); 440 V DC (800 V DC DC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] \/ [Uimp] insulation \/ impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC \/ 1000 V DC \/ 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A, AC-21B, 220–690 V AC; 250 A, AC-22B, up to 690 V AC; 250 A DC-21B\/DC-22B at 220–440 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.6 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making\/breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.6 kA at 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse carriers handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbars, 60 mm, turnable hook\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ tightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM10 terminals (6 N.m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D) \/ net weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e184 mm x 306 mm x 110 mm \/ 2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP3x front face (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-1, IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LV480805 is a fixed, non-switchable ISFT250 disconnector rated 250 A, sized for NH1 fuse links and a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses installed. Pick the 60 mm busbar, turnable hook version over the other ISFT250 mounting variants in this range when it matches the busbar or cable connection already used in the panel.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229768978715,"sku":"LV480805","price":288.2,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480805-isft250-fuse-switch-disconnector.jpg?v=1790869224"},{"product_id":"schneider-electric-lv480806-isft400-fuse-switch-disconnector","title":"Schneider Electric LV480806 Fupact ISFT400 3P 400 A NH2 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV480806 is a three-pole Fupact ISFT400 fuse-switch disconnector rated 400 A at 690 V AC for AC-21B duty, sized for NH2 fuse links and built for backplate mounting with m10 terminals. It carries a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses and a 15.2 kA for 1 s short-time withstand rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480806\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISFT400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 fuse carriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A at 40 °C (34 W per fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20); 440 V DC (800 V DC DC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] \/ [Uimp] insulation \/ impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC \/ 1000 V DC \/ 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A, AC-21B, 220–690 V AC; 400 A, AC-22B, up to 690 V AC; 400 A DC-21B\/DC-22B at 220–440 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.2 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making\/breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.4 kA at 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse carriers handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ tightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM10 terminals (20 N.m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D) \/ net weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm x 306 mm x 130 mm \/ 2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP3x front face (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-1, IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LV480806 is a fixed, non-switchable ISFT400 disconnector rated 400 A, sized for NH2 fuse links and a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses installed. Pick the backplate version over the other ISFT400 mounting variants in this range when it matches the busbar or cable connection already used in the panel.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229769339163,"sku":"LV480806","price":217.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480806-isft400-fuse-switch-disconnector.jpg?v=1790869235"},{"product_id":"schneider-electric-lv480807-isft400-fuse-switch-disconnector","title":"Schneider Electric LV480807 Fupact ISFT400 3P 400 A NH2 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV480807 is a three-pole Fupact ISFT400 fuse-switch disconnector rated 400 A at 690 V AC for AC-21B duty, sized for NH2 fuse links and built for 60 mm busbar, turnable hook mounting with m10 terminals. It carries a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses and a 15.2 kA for 1 s short-time withstand rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480807\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISFT400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 fuse carriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A at 40 °C (34 W per fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20); 440 V DC (800 V DC DC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] \/ [Uimp] insulation \/ impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC \/ 1000 V DC \/ 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A, AC-21B, 220–690 V AC; 400 A, AC-22B, up to 690 V AC; 400 A DC-21B\/DC-22B at 220–440 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.2 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making\/breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.4 kA at 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse carriers handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbars, 60 mm, turnable hook\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ tightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM10 terminals (8 N.m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D) \/ net weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm x 306 mm x 130 mm \/ 2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP3x front face (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-1, IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LV480807 is a fixed, non-switchable ISFT400 disconnector rated 400 A, sized for NH2 fuse links and a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses installed. Pick the 60 mm busbar, turnable hook version over the other ISFT400 mounting variants in this range when it matches the busbar or cable connection already used in the panel.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229769601307,"sku":"LV480807","price":402.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480807-isft400-fuse-switch-disconnector.jpg?v=1790869244"},{"product_id":"schneider-electric-lv480808-isft630-fuse-switch-disconnector","title":"Schneider Electric LV480808 Fupact ISFT630 3P 630 A NH3 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV480808 is a three-pole Fupact ISFT630 fuse-switch disconnector rated 630 A at 690 V AC for AC-21B duty, sized for NH3 fuse links and built for backplate mounting with m10 terminals. It carries a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses and a 20.4 kA for 1 s short-time withstand rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480808\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISFT630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P (3 fuse carriers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A at 40 °C (48 W per fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20); 440 V DC (800 V DC DC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] \/ [Uimp] insulation \/ impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC \/ 1000 V DC \/ 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A, AC-21B, 220–690 V AC; 630 A, AC-22B, up to 690 V AC; 630 A DC-21B\/DC-22B at 220–440 V DC (3 poles in series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making\/breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.4 kA at 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse carriers handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBackplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ tightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM10 terminals (20 N.m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D) \/ net weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 mm x 306 mm x 130 mm \/ 3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP3x front face (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-1, IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LV480808 is a fixed, non-switchable ISFT630 disconnector rated 630 A, sized for NH3 fuse links and a 80 kA at 415 V AC, 80 kA at 500 V AC, 25 kA at 690 V AC breaking capacity with fuses installed. Pick the backplate version over the other ISFT630 mounting variants in this range when it matches the busbar or cable connection already used in the panel.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229769961755,"sku":"LV480808","price":305.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480808-isft630-fuse-switch-disconnector.jpg?v=1790869253"},{"product_id":"schneider-electric-lv480850-isfl160-fuse-switch-disconnector","title":"Schneider Electric LV480850 Fupact ISFL160 3P 160 A NH000\/NH00 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV480850 is a three-pole Fupact ISFL160 fuse-switch disconnector rated 160 A at 690 V AC for AC-21B duty, sized for NH000\/NH00 fuse links and built for 60 mm busbar, hook-on mounting with m8 terminals. It carries a 100 kA at 415–690 V AC breaking capacity with fuses and a 5 kA for 1 s short-time withstand rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISFL160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, switchable as one 3-pole unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH000\/NH00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A at 40 °C (12 W per fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20); 800 V DC DC-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] \/ [Uimp] insulation \/ impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC \/ 1000 V DC \/ 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A, AC-21B\/AC-22B, 220–690 V AC (80 A at 800 V AC); 160 A, AC-23B, 220–415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 415–690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making\/breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.65 kA at 690 V (rated making\/breaking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse carriers handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbars, 60 mm, hook-on connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ tightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM8 terminals (14 N.m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D) \/ net weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mm x 405 mm x 123 mm \/ 1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-1, IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LV480850 switches all three poles together from a single handle, rated 160 A with a 100 kA at 415–690 V AC breaking capacity with fuses installed. Choose the 60 mm busbar, hook-on variant over the other ISFL160 mounting options when the busbar spacing and cable size in the panel match this connection type.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229770354971,"sku":"LV480850","price":129.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480850-isfl160-fuse-switch-disconnector.jpg?v=1790869262"},{"product_id":"schneider-electric-lv480851-isfl160-fuse-switch-disconnector","title":"Schneider Electric LV480851 Fupact ISFL160 3P 160 A NH00\/NH000 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV480851 is a three-pole Fupact ISFL160 fuse-switch disconnector rated 160 A at 690 V AC for AC-21B duty, sized for NH00\/NH000 fuse links and built for 60 mm busbar, cable connectors mounting with cable connectors, 95 mm². It carries a 100 kA at 415–690 V AC breaking capacity with fuses and a 5 kA for 1 s short-time withstand rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480851\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISFL160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, switchable as one 3-pole unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH00\/NH000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A at 40 °C (12 W per fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20); 800 V DC DC-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] \/ [Uimp] insulation \/ impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC \/ 1000 V DC \/ 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A, AC-21B\/AC-22B, 220–690 V AC (80 A at 800 V AC); 160 A, AC-23B, 220–415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 415–690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making\/breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.65 kA at 690 V (rated making\/breaking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse carriers handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbars, 60 mm, hook terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ tightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable connectors, 95 mm² (14 N.m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D) \/ net weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mm x 405 mm x 123 mm \/ 1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-1, IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LV480851 switches all three poles together from a single handle, rated 160 A with a 100 kA at 415–690 V AC breaking capacity with fuses installed. Choose the 60 mm busbar, cable connectors variant over the other ISFL160 mounting options when the busbar spacing and cable size in the panel match this connection type.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229770715419,"sku":"LV480851","price":129.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480851-isfl160-fuse-switch-disconnector.jpg?v=1790869271"},{"product_id":"schneider-electric-lv480852-isfl160-fuse-switch-disconnector","title":"Schneider Electric LV480852 Fupact ISFL160 3P 160 A NH000\/NH00 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV480852 is a three-pole Fupact ISFL160 fuse-switch disconnector rated 160 A at 690 V AC for AC-21B duty, sized for NH000\/NH00 fuse links and built for 100 mm busbar, direct mount mounting with m8 terminals. It carries a 100 kA at 415–690 V AC breaking capacity with fuses and a 5 kA for 1 s short-time withstand rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480852\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISFL160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, switchable as one 3-pole unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH000\/NH00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A at 40 °C (12 W per fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20); 800 V DC DC-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] \/ [Uimp] insulation \/ impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC \/ 1000 V DC \/ 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A, AC-21B\/AC-22B, 220–690 V AC (80 A at 800 V AC); 160 A, AC-23B, 220–415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 415–690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making\/breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.65 kA at 690 V (rated making\/breaking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse carriers handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbars, 100 mm, direct connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ tightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM8 terminals (14 N.m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D) \/ net weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mm x 405 mm x 123 mm \/ 1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-1, IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LV480852 switches all three poles together from a single handle, rated 160 A with a 100 kA at 415–690 V AC breaking capacity with fuses installed. Choose the 100 mm busbar, direct mount variant over the other ISFL160 mounting options when the busbar spacing and cable size in the panel match this connection type.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229771043099,"sku":"LV480852","price":116.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480852-isfl160-fuse-switch-disconnector.jpg?v=1790869280"},{"product_id":"schneider-electric-lv480856-isfl250-fuse-switch-disconnector","title":"Schneider Electric LV480856 Fupact ISFL250 3P 250 A NH1 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV480856 is a three-pole Fupact ISFL250 fuse-switch disconnector rated 250 A at 690 V AC for AC-21B duty, sized for NH1 fuse links and built for 185 mm busbar, direct mount mounting with screw connection downstream m12 250 a. It carries a 120 kA at 415–690 V AC breaking capacity with fuses and a 15 kA for 1 s short-time withstand rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480856\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISFL250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, switchable as one 3-pole unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 40 °C (23 W per fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20); 800 V DC DC-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] \/ [Uimp] insulation \/ impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC \/ 1000 V DC \/ 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A, AC-21B, 220–690 V AC (160 A at 800 V AC); 250 A, AC-22B, 220–500 V AC; 250 A, AC-23B, 220–415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 kA at 415–690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making\/breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 690 V (rated making\/breaking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse carriers handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbars, 185 mm, direct or hook-on connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ tightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew connection downstream M12 250 A; direct connection upstream 250 A, 185 mm (40 N.m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D) \/ net weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 741 mm x 190 mm \/ 4.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-1, IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LV480856 switches all three poles together from a single handle, rated 250 A with a 120 kA at 415–690 V AC breaking capacity with fuses installed. Choose the 185 mm busbar, direct mount variant over the other ISFL250 mounting options when the busbar spacing and cable size in the panel match this connection type.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229771763995,"sku":"LV480856","price":289.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480856-isfl250-fuse-switch-disconnector.jpg?v=1790869290"},{"product_id":"schneider-electric-lv480857-isfl400-fuse-switch-disconnector","title":"Schneider Electric LV480857 Fupact ISFL400 3P 400 A NH2 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV480857 is a three-pole Fupact ISFL400 fuse-switch disconnector rated 400 A at 690 V AC for AC-21B duty, sized for NH2 fuse links and built for 185 mm busbar, direct mount mounting with screw connection downstream m12 400 a. It carries a 120 kA at 415–690 V AC breaking capacity with fuses and a 15 kA for 1 s short-time withstand rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480857\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISFL400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, switchable as one 3-pole unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A at 40 °C (34 W per fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20); 800 V DC DC-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] \/ [Uimp] insulation \/ impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC \/ 1000 V DC \/ 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A, AC-21B, 220–690 V AC (250 A at 800 V AC); 400 A, AC-22B, 220–500 V AC; 400 A, AC-23B, 220–415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 kA at 415–690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making\/breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 690 V (rated making\/breaking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse carriers handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbars, 185 mm, direct or hook-on connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ tightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew connection downstream M12 400 A; direct connection upstream 400 A, 185 mm (40 N.m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D) \/ net weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 741 mm x 190 mm \/ 5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-1, IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LV480857 switches all three poles together from a single handle, rated 400 A with a 120 kA at 415–690 V AC breaking capacity with fuses installed. Choose the 185 mm busbar, direct mount variant over the other ISFL400 mounting options when the busbar spacing and cable size in the panel match this connection type.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229772091675,"sku":"LV480857","price":294.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480857-isfl400-fuse-switch-disconnector.jpg?v=1790869299"},{"product_id":"schneider-electric-lv480858-isfl630-fuse-switch-disconnector","title":"Schneider Electric LV480858 Fupact ISFL630 3P 630 A NH3 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV480858 is a three-pole Fupact ISFL630 fuse-switch disconnector rated 630 A at 690 V AC for AC-21B duty, sized for NH3 fuse links and built for 185 mm busbar, direct mount mounting with screw connection downstream m12 630 a. It carries a 120 kA at 415–690 V AC breaking capacity with fuses and a 25 kA for 1 s short-time withstand rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480858\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice short name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISFL630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P, switchable as one 3-pole unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A at 40 °C (48 W per fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20); 800 V DC DC-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] \/ [Uimp] insulation \/ impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC \/ 1000 V DC \/ 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A, AC-21B, 220–690 V AC (400 A at 800 V AC); 630 A, AC-22B, 220–500 V AC; 630 A, AC-23B, 220–415 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 kA at 415–690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated making\/breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 kA at 690 V (rated making\/breaking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse carriers handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBusbars, 185 mm, direct or hook-on connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections \/ tightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew connection downstream M12 630 A; direct connection upstream 630 A, 185 mm (40 N.m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D) \/ net weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 741 mm x 190 mm \/ 5.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-1, IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LV480858 switches all three poles together from a single handle, rated 630 A with a 120 kA at 415–690 V AC breaking capacity with fuses installed. Choose the 185 mm busbar, direct mount variant over the other ISFL630 mounting options when the busbar spacing and cable size in the panel match this connection type.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229772583195,"sku":"LV480858","price":363.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480858-isfl630-fuse-switch-disconnector.jpg?v=1790869309"},{"product_id":"schneider-electric-lv480902-fupact-isfl400","title":"Schneider Electric LV480902 FuPacT ISFL400 3 x 1P 400 A 120 kA Busbar-Mount Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV480902 FuPacT ISFL400 is a 3 x 1-pole vertical fuse switch disconnector rated 400 A at 690 V AC, built for direct mounting on 185 mm busbars. It takes NH2 fuses, delivers a 120 kA breaking capacity, and needs no extra clearance for current-transformer installation, since its compact 100 mm width keeps the panel footprint small for distribution and equipment-protection duty.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480902\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT ISFL400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse-switch disconnector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 x 1P switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of fuse carriers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20, 800 V DC DC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC \/ 1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A (AC-21B\/AC-22B up to 690 V, AC-23B up to 415 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 kA at 415 V, 500 V and 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Im] Rated making and breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA at 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVisible break\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical, fixed, on busbars, one above the other\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12 screw downstream 400 A; direct connection upstream to 185 mm busbars\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 x 741 x 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe ISFL400 is the 400 A vertical module in the FuPacT ISFL range, built around NH2 fuse carriers and direct connection to 185 mm busbars; projects needing a higher current or NH3 fuses on the same busbar centres use the 630 A ISFL630 instead. Three individually switchable 1-pole units stack one above the other to form a 3-pole assembly, so each phase keeps visible-break isolation per EN\/IEC 60947-3 and its own contact-position indicator. The 15 kA\/1 s short-time withstand and 120 kA breaking capacity let it serve as a sub-distribution disconnector ahead of downstream fused outgoing circuits, while the 3-padlock provision on the fuse-carrier handle supports lockout without extra hardware.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229774483739,"sku":"LV480902","price":337.15,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480902-fupact-isfl400-fuse-switch-disconnector.jpg?v=1790869400"},{"product_id":"schneider-electric-lv480903-fupact-isfl630","title":"Schneider Electric LV480903 FuPacT ISFL630 3 x 1P 630 A 120 kA Busbar-Mount Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV480903 FuPacT ISFL630 is a 3 x 1-pole vertical fuse switch disconnector rated 630 A at 690 V AC, built for direct mounting on 185 mm busbars. It takes NH3 fuses, delivers a 120 kA breaking capacity, and needs no extra clearance for current-transformer installation, since its compact 100 mm width keeps the panel footprint small for distribution and equipment-protection duty.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV480903\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT ISFL630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse-switch disconnector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 x 1P switchable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of fuse carriers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20, 800 V DC DC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC \/ 1000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A (AC-21B\/AC-22B up to 690 V, AC-23B up to 415 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 kA at 415 V, 500 V and 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kA for 1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Im] Rated making and breaking capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 kA at 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, conforming to EN\/IEC 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVisible break\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical, fixed, on busbars, one above the other\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM12 screw downstream 630 A; direct connection upstream to 185 mm busbars\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 x 741 x 190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIK07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe ISFL630 is the 630 A vertical module in the FuPacT ISFL range, built around NH3 fuse carriers on the same 185 mm busbar centres and 100 mm width as the 400 A ISFL400; pick it when the circuit load exceeds 400 A continuous. Three individually switchable 1-pole units stack one above the other to form a 3-pole assembly, so each phase keeps visible-break isolation per EN\/IEC 60947-3 and its own contact-position indicator. Its 25 kA\/1 s short-time withstand and 52.5 kA making\/breaking capacity at 690 V are higher than the 400 A variant's, which matters when selecting for selective coordination with downstream fused outgoing circuits, and the 3-padlock provision on the fuse-carrier handle supports lockout without extra hardware.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229774745883,"sku":"LV480903","price":355.85,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv480903-fupact-isfl630-fuse-switch-disconnector.jpg?v=1790869410"},{"product_id":"schneider-electric-lv481403-fupact-gsd63","title":"Schneider Electric LV481403 FuPacT GSD63 3P 63 A NH000 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV481403 FuPacT GSD63 is a 3-pole switch disconnector fuse rated 63 A at up to 690 V AC, built for front or right-side handle control. It takes DIN NH000 fuses and protects distribution circuits in buildings, infrastructure and industrial plants against short-circuits and overloads, with a 100 kA breaking capacity with fuses at 415 V.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV481403\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT GS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-disconnector-fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of fuse carriers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A at 220\/240-660\/690 V AC, AC-22A\/AC-23A\/AC-22B\/AC-23B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Iq] Breaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 415 V and 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kW at 380\/400 V; 55 kW at 660\/690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of operating handle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect frontal, external frontal, external right side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical, fixed, on backplate or DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower circuit: screw-clamp terminals 10-25 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e136 x 162 x 116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with terminal cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe GSD63 is the smallest frame in the FuPacT GS switch-disconnector-fuse range, sized for DIN NH000 fuses up to 63 A; larger loads step up through the NH00, NH1, NH2 and NH3 frame sizes in the same family. Its direct frontal handle option keeps the footprint compact for panels with front access, while the external front or right-side rotary handle (with 200, 320 or 400 mm extension shafts) suits enclosures where the device sits behind a door. The 100 kA breaking capacity with fuses at both 415 V and 690 V means the fuse, not the switch mechanism, carries the fault-interruption duty.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229775040795,"sku":"LV481403","price":159.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv481403-fupact-gsd63-fuse-switch-disconnector.jpg?v=1790869455"},{"product_id":"schneider-electric-lv481413-fupact-gsd125","title":"Schneider Electric LV481413 FuPacT GSD125 3P 125 A NH00 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV481413 FuPacT GSD125 is a 3-pole switch disconnector fuse rated 125 A at up to 690 V AC, built for front or right-side handle control. It takes DIN NH00 fuses and protects distribution circuits in buildings, infrastructure and industrial plants against short-circuits and overloads, with an 80 kA breaking capacity with fuses at 415 V.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV481413\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT GS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-disconnector-fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of fuse carriers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A at 220\/240-660\/690 V AC, AC-22A\/AC-23A\/AC-22B\/AC-23B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Iq] Breaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kA at 415 V; 50 kA at 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 kW at 380\/400 V; 110 kW at 660\/690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of operating handle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect frontal, external frontal, external right side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical, fixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower circuit: bare cable connectors 20 mm²; lugs-ring terminals 35-95 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e148 x 162 x 116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with terminal cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe GSD125 steps up from the GSD63 to DIN NH00 fuses and a 125 A rating while keeping the same direct and external rotary handle options; pick it over the smaller NH000 frame once the circuit load exceeds 63 A. Its 80 kA breaking capacity with fuses at 415 V drops to 50 kA at 690 V, a distinction worth checking against the upstream fault level on higher-voltage distribution. The bare-cable or lugs-ring terminal options (35-95 mm²) give more conductor flexibility than the GSD63's screw-clamp-only termination.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229775302939,"sku":"LV481413","price":189.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv481413-fupact-gsd125-fuse-switch-disconnector.jpg?v=1790869465"},{"product_id":"schneider-electric-lv481423-fupact-gsd160-3p","title":"Schneider Electric LV481423 FuPacT GSD160 3P 160 A NH00 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV481423 FuPacT GSD160 is a 3-pole switch disconnector fuse rated 160 A at up to 690 V AC, built for front or right-side handle control. It takes DIN NH00 fuses and protects distribution circuits in buildings, infrastructure and industrial plants against short-circuits and overloads, with an 80 kA breaking capacity with fuses at 415 V.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV481423\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT GS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-disconnector-fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of fuse carriers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A at 220\/240-690 V AC, AC-22A\/AC-23A\/AC-22B\/AC-23B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Iq] Breaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kA at 415 V; 50 kA at 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kW at 380\/400 V; 110 kW at 660\/690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of operating handle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect frontal, external frontal, external right side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical, fixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower circuit: bare cable connectors 20 mm²; lugs-ring terminals 50-95 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e148 x 162 x 116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with terminal cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe GSD160 shares the GSD125's DIN NH00 fuse size and 148 x 162 x 116 mm housing but is rated 160 A rather than 125 A, so it is the choice when the circuit load sits between the NH00 frame's upper limits before stepping up to the NH1-based GSD250. Its 80 kA breaking capacity with fuses at 415 V (50 kA at 690 V) matches the GSD125, since both share the same fuse-carrier design. The lugs-ring terminal range extends to 95 mm² to suit the higher continuous current.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229775597851,"sku":"LV481423","price":171.05,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv481423-fupact-gsd160-3p-fuse-switch-disconnector.jpg?v=1790869474"},{"product_id":"schneider-electric-lv481424-fupact-gsd160-4p","title":"Schneider Electric LV481424 FuPacT GSD160 4P 160 A NH00 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV481424 FuPacT GSD160 is a 4-pole switch disconnector fuse rated 160 A at up to 690 V AC, built for front or right-side handle control. It takes DIN NH00 fuses and protects distribution circuits in buildings, infrastructure and industrial plants against short-circuits and overloads, with an 80 kA breaking capacity with fuses at 415 V.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV481424\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT GS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-disconnector-fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of fuse carriers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A at 220\/240-690 V AC, AC-22A\/AC-23A\/AC-22B\/AC-23B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Iq] Breaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kA at 415 V; 50 kA at 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kW at 380\/400 V; 110 kW at 660\/690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of operating handle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect frontal, external frontal, external right side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical, fixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower circuit: bare cable connectors 20 mm²; lugs-ring terminals 50-95 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e184 x 162 x 116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with terminal cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe GSD160 4P adds a fourth switched pole and internal neutral links to the 3-pole GSD160, for circuits needing a switched neutral rather than a solid neutral bar; it is 36 mm wider than the 3-pole version but shares the same 160 A rating, NH00 fuse size and 80 kA\/415 V breaking capacity. Choose the 3-pole variant instead where the neutral does not need to be switched. The front or external right-side handle options carry over unchanged from the 3-pole frame.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229775925531,"sku":"LV481424","price":253.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv481424-fupact-gsd160-4p-fuse-switch-disconnector.jpg?v=1790869484"},{"product_id":"schneider-electric-lv481433-fupact-gsd250-3p","title":"Schneider Electric LV481433 FuPacT GSD250 3P 250 A NH1 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV481433 FuPacT GSD250 is a 3-pole switch disconnector fuse rated 250 A at up to 690 V AC, built for front or right-side handle control. It takes DIN NH1 fuses and protects distribution circuits in buildings, infrastructure and industrial plants against short-circuits and overloads, with an 80 kA breaking capacity with fuses at 415 V.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV481433\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT GS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-disconnector-fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of fuse carriers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 220\/240-660\/690 V AC, AC-22A\/AC-23A\/AC-22B\/AC-23B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Iq] Breaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kA at 415 V; 50 kA at 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e132 kW at 380\/400 V; 220 kW at 660\/690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of operating handle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect frontal, external frontal, external right side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical, fixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower circuit: bare cable connectors 32 mm²; lugs-ring terminals 95-240 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e234 x 195 x 146 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with terminal cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe GSD250 steps up to a DIN NH1 fuse carrier, the next frame above the NH00-based GSD160, for circuits rated above 160 A up to 250 A. Its 234 x 195 x 146 mm housing is larger than the NH00 frames and its lugs-ring terminal range extends to 240 mm² to carry the higher continuous current. The 80 kA\/415 V and 50 kA\/690 V breaking capacities with fuses match the GSD125\/GSD160, since fault-current interruption is carried by the fuse rather than the switch frame.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229776187675,"sku":"LV481433","price":317.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv481433-fupact-gsd250-3p-fuse-switch-disconnector.jpg?v=1790869400"},{"product_id":"schneider-electric-lv481443-fupact-gsd400-3p","title":"Schneider Electric LV481443 FuPacT GSD400 3P 400 A NH2 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV481443 FuPacT GSD400 is a 3-pole switch disconnector fuse rated 400 A at up to 690 V AC, built for front or right-side handle control. It takes DIN NH2 fuses and protects distribution circuits in buildings, infrastructure and industrial plants against short-circuits and overloads, with a 50 kA breaking capacity with fuses at 415 V and 690 V.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV481443\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT GS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-disconnector-fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of fuse carriers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A at 220\/240-660\/690 V AC, AC-22A\/AC-22B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Iq] Breaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 415 V and 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 kW at 380\/400 V; 295 kW at 660\/690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of operating handle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect frontal, external frontal, external right side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical, fixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower circuit: bare cable connectors 45 mm²; lugs-ring terminals 185-240 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e252 x 205 x 149 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with terminal cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe GSD400 steps up to a DIN NH2 fuse carrier, above the NH1-based GSD250, for circuits rated above 250 A up to 400 A. Its 50 kA breaking capacity with fuses is lower than the smaller frames' 80 kA at 415 V, but is now constant across both 415 V and 690 V rather than dropping at the higher voltage. Only AC-22A\/AC-22B utilisation categories are rated at this frame, so check the application is a switching duty rather than a frequent-operation AC-23 motor-type load before specifying it.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229776449819,"sku":"LV481443","price":495.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv481443-fupact-gsd400-3p-fuse-switch-disconnector.jpg?v=1790869411"},{"product_id":"schneider-electric-lv481444-fupact-gsd400-4p","title":"Schneider Electric LV481444 FuPacT GSD400 4P 400 A NH2 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV481444 FuPacT GSD400 is a 4-pole switch disconnector fuse rated 400 A at up to 690 V AC, built for front or right-side handle control. It takes DIN NH2 fuses and protects distribution circuits in buildings, infrastructure and industrial plants against short-circuits and overloads, with a 50 kA breaking capacity with fuses at 415 V and 690 V.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV481444\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT GS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-disconnector-fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of fuse carriers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A at 220\/240-660\/690 V AC, AC-22A\/AC-22B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Iq] Breaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA at 415 V and 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 kW at 380\/400 V; 295 kW at 660\/690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of operating handle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect frontal, external frontal, external right side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical, fixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower circuit: bare cable connectors 45 mm²; lugs-ring terminals 185-240 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e318 x 205 x 149 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with terminal cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe GSD400 4P adds a fourth switched pole and internal neutral links to the 3-pole GSD400, for circuits needing a switched rather than solid neutral; it shares the 3-pole version's 400 A rating, NH2 fuse size and 50 kA breaking capacity, in a 318 mm wide housing. Choose the 3-pole variant where the neutral does not need to be switched. Only AC-22A\/AC-22B utilisation categories are rated at this frame, so confirm the duty is switching rather than frequent AC-23 motor-type operation.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229776711963,"sku":"LV481444","price":758.45,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv481444-fupact-gsd400-4p-fuse-switch-disconnector.png?v=1790869420"},{"product_id":"schneider-electric-lv481453-fupact-gsd630-3p","title":"Schneider Electric LV481453 FuPacT GSD630 3P 630 A NH3 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV481453 FuPacT GSD630 is a 3-pole switch disconnector fuse rated 630 A at up to 690 V AC, built for external front or right-side handle control. It takes DIN NH3 fuses and protects distribution circuits in buildings, infrastructure and industrial plants against short-circuits and overloads, with a 100 kA breaking capacity with fuses at 415 V and 690 V.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV481453\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT GS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-disconnector-fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of fuse carriers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (1000 V AC AC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A at 220\/240-660\/690 V AC, AC-22A\/AC-22B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Iq] Breaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 415 V and 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e355 kW at 380\/400 V; 295 kW at 660\/690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of operating handle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal frontal, external right side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical, fixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower circuit: bare cable connectors 63 mm²; lugs-ring terminals 2 cables 150 mm² or 2 cables 300 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e364 x 300 x 250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with terminal cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe GSD630 moves to a DIN NH3 fuse carrier and a higher 1000 V insulation and 12 kV impulse withstand rating than the NH2-based GSD400, reflecting the larger frame's heavier-duty application. Unlike the smaller GSD63-GSD400 frames, it drops the direct frontal handle option in favour of external frontal or right-side rotary handles only, since the frame size no longer suits a direct-mount handle. Its dual-cable lugs-ring terminals (2 x 150 mm² or 2 x 300 mm²) are sized for the 630 A continuous rating, and the 100 kA breaking capacity with fuses holds constant at both 415 V and 690 V.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229776974107,"sku":"LV481453","price":969.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv481453-fupact-gsd630-3p-fuse-switch-disconnector.jpg?v=1790869430"},{"product_id":"schneider-electric-lv481454-fupact-gsd630-4p","title":"Schneider Electric LV481454 FuPacT GSD630 4P 630 A NH3 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV481454 FuPacT GSD630 is a 4-pole switch disconnector fuse rated 630 A at up to 690 V AC, built for external front or right-side handle control. It takes DIN NH3 fuses and protects distribution circuits in buildings, infrastructure and industrial plants against short-circuits and overloads, with a 100 kA breaking capacity with fuses at 415 V and 690 V.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV481454\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT GS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-disconnector-fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of fuse carriers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (1000 V AC AC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A at 220\/240-660\/690 V AC, AC-22A\/AC-22B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Iq] Breaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 415 V and 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e355 kW at 380\/400 V; 295 kW at 660\/690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of operating handle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal frontal, external right side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical, fixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower circuit: bare cable connectors 63 mm²; lugs-ring terminals 2 cables 150 mm² or 2 cables 300 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e458 x 300 x 250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with terminal cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe GSD630 4P adds a fourth switched pole and internal neutral links to the 3-pole GSD630, for circuits needing a switched rather than solid neutral; it keeps the 3-pole version's 630 A rating, NH3 fuse size and 100 kA breaking capacity in a wider 458 mm housing. Choose the 3-pole variant where the neutral does not need to be switched. As with the 3-pole frame, only external frontal or right-side rotary handles are offered at this size, not a direct-mount handle.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229777269019,"sku":"LV481454","price":1396.45,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv481454-fupact-gsd630-4p-fuse-switch-disconnector.jpg?v=1790869439"},{"product_id":"schneider-electric-lv481463-fupact-gsd800","title":"Schneider Electric LV481463 FuPacT GSD800 3P 800 A NH3 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV481463 FuPacT GSD800 is a 3-pole switch disconnector fuse rated 800 A at up to 690 V AC, built for external front or right-side handle control. It takes DIN NH3 fuses and protects distribution circuits in buildings, infrastructure and industrial plants against short-circuits and overloads, with a 100 kA breaking capacity with fuses at 415 V and 690 V.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV481463\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT GS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-disconnector-fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of fuse carriers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (1000 V AC AC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A at 220\/240-660\/690 V AC, AC-22A\/AC-22B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Iq] Breaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 415 V and 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 kW at 380\/400 V; 600 kW at 660\/690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of operating handle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal frontal, external right side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical, fixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower circuit: bare cable connectors 63 mm²; lugs-ring terminals 2 cables 150 mm² or 2 cables 300 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e364 x 300 x 250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with terminal cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe GSD800 shares the GSD630's 364 x 300 x 250 mm NH3 housing and 100 kA breaking capacity but is rated 800 A rather than 630 A, so it is the choice for heavier distribution feeders within the same physical footprint. Its rated operational power rises to 450 kW at 380\/400 V and 600 kW at 660\/690 V, well above the GSD630's figures, reflecting the higher continuous current. Only AC-22A\/AC-22B switching duty is rated at this frame, consistent with the larger GSD sizes above GSD250.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229777563931,"sku":"LV481463","price":1394.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv481463-fupact-gsd800-fuse-switch-disconnector.jpg?v=1790869448"},{"product_id":"schneider-electric-lv481473-fupact-gsd1250-3p","title":"Schneider Electric LV481473 FuPacT GSD1250 3P 1250 A NH4 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV481473 FuPacT GSD1250 is a 3-pole switch disconnector fuse rated 1250 A at up to 690 V AC, built for external front or right-side handle control. It takes DIN NH4 fuses and protects distribution circuits in buildings, infrastructure and industrial plants against short-circuits and overloads, with a 100 kA breaking capacity with fuses at 415 V and 690 V.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV481473\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT GS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-disconnector-fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of fuse carriers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (1000 V AC AC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1250 A at 220\/240-415 V AC, AC-22A\/AC-23A\/AC-22B\/AC-23B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Iq] Breaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 415 V and 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 kW at 380\/400 V; 900 kW at 660\/690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of operating handle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal frontal, external right side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical, fixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower circuit: bare cable connectors 80 mm²; lugs-ring terminals 4 cables 185 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e442 x 300 x 289 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with terminal cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe GSD1250 is the largest frame in the FuPacT GS range, carrying DIN NH4 fuses and a four-cable, 185 mm² lugs-ring terminal to handle the 1250 A continuous rating; the GSD800 covers the next size down on NH3 fuses. Its 442 x 300 x 289 mm housing and 25 kg weight are the largest in the switch-disconnector-fuse family, and it is the only GS frame above GSD250 that keeps AC-23A\/AC-23B motor-type utilisation categories rated, alongside AC-22A\/AC-22B switching duty. The 100 kA breaking capacity with fuses holds at both 415 V and 690 V.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229777858843,"sku":"LV481473","price":2242.35,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv481473-fupact-gsd1250-3p-fuse-switch-disconnector.jpg?v=1790869462"},{"product_id":"schneider-electric-lv481474-fupact-gsd1250-4p","title":"Schneider Electric LV481474 FuPacT GSD1250 4P 1250 A NH4 Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV481474 FuPacT GSD1250 is a 4-pole switch disconnector fuse rated 1250 A at up to 690 V AC, built for external front or right-side handle control. It takes DIN NH4 fuses and protects distribution circuits in buildings, infrastructure and industrial plants against short-circuits and overloads, with a 100 kA breaking capacity with fuses at 415 V and 690 V.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV481474\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT GS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-disconnector-fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of fuse carriers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN NH4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (1000 V AC AC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1250 A at 220\/240-415 V AC, AC-22A\/AC-23A\/AC-22B\/AC-23B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Iq] Breaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 kA at 415 V and 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 kW at 380\/400 V; 900 kW at 660\/690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of operating handle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExternal frontal, external right side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical, fixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower circuit: bare cable connectors 80 mm²; lugs-ring terminals 4 cables 185 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e562 x 300 x 289 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with terminal cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe GSD1250 4P adds a fourth switched pole and internal neutral links to the 3-pole GSD1250, for circuits needing a switched rather than solid neutral; it keeps the 3-pole version's 1250 A rating, NH4 fuse size and 100 kA breaking capacity in a wider 562 mm, 30 kg housing. Choose the 3-pole variant where the neutral does not need to be switched. Like the 3-pole frame, it is the largest GS size that still carries AC-23A\/AC-23B motor-type utilisation categories alongside AC-22A\/AC-22B switching duty.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229778120987,"sku":"LV481474","price":2669.15,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv481474-fupact-gsd1250-4p-fuse-switch-disconnector.jpg?v=1790869921"},{"product_id":"schneider-electric-lv481523-fupact-gsc125-3p","title":"Schneider Electric LV481523 FuPacT GSC125 3P 125 A NFC 22x58mm Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV481523 FuPacT GSC125 is a 3-pole switch disconnector fuse rated 125 A at up to 690 V AC, built for front or right-side handle control. It takes NFC cylindrical fuse links sized 22 x 58 mm and protects distribution circuits in buildings, infrastructure and industrial plants against short-circuits and overloads, with an 80 kA breaking capacity with fuses at 415 V.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV481523\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT GS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-disconnector-fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of fuse carriers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFC cylindrical 22 x 58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A at 220\/240-415 V AC; 100-125 A at 660\/690 V AC, AC-22A\/AC-23A\/AC-22B\/AC-23B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Iq] Breaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kA at 415 V; 100 kA at 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 kW at 380\/400 V; 110 kW at 660\/690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of operating handle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect frontal, external frontal, external right side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical, fixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower circuit: bare cable connectors 20 mm²; lugs-ring terminals 35-95 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e148 x 162 x 116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with terminal cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe GSC125 shares the GSD125's 125 A rating, 148 x 162 x 116 mm housing and handle options but is built for NFC cylindrical 22 x 58 mm fuse links rather than DIN NH00 blade fuses; pick the GSC125 where the installation standardises on cylindrical fuses, and the GSD125 where DIN blade fuses are the local stock item. Its breaking capacity with fuses is 80 kA at 415 V, rising to 100 kA at 690 V, the reverse pattern of the DIN-fuse GSD125, which reflects the different fuse link's interrupting characteristic.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229778481435,"sku":"LV481523","price":189.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv481523-fupact-gsc125-3p-fuse-switch-disconnector.jpg?v=1790869482"},{"product_id":"schneider-electric-lv481524-fupact-gsc125-4p","title":"Schneider Electric LV481524 FuPacT GSC125 4P 125 A NFC 22x58mm Fuse Switch Disconnector","description":"\u003cp\u003eThe Schneider Electric LV481524 FuPacT GSC125 is a 4-pole switch disconnector fuse rated 125 A at up to 690 V AC, built for front or right-side handle control. It takes NFC cylindrical fuse links sized 22 x 58 mm and protects distribution circuits in buildings, infrastructure and industrial plants against short-circuits and overloads, with an 80 kA breaking capacity with fuses at 415 V.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV481524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuPacT GS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch-disconnector-fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of fuse carriers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse type \/ size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNFC cylindrical 22 x 58 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC 50\/60 Hz (800 V AC AC-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A at 220\/240-415 V AC; 100-125 A at 660\/690 V AC, AC-22A\/AC-23A\/AC-22B\/AC-23B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Iq] Breaking capacity with fuses\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 kA at 415 V; 100 kA at 690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 kW at 380\/400 V; 110 kW at 660\/690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of operating handle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect frontal, external frontal, external right side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical, fixed, on backplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower circuit: bare cable connectors 20 mm²; lugs-ring terminals 35-95 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 N.m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e184 x 162 x 116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 (with terminal cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-1\u003c\/li\u003e\n\u003cli\u003eEN\/IEC 60947-3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe GSC125 4P adds a fourth switched pole and internal neutral links to the 3-pole GSC125, for circuits needing a switched rather than solid neutral; it keeps the same 125 A rating and NFC 22 x 58 mm cylindrical fuse carriers in a 184 mm wide housing. Choose the 3-pole variant where the neutral does not need to be switched, or the DIN-fuse GSD125 where blade fuses rather than cylindrical fuse links are the local standard.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229778841883,"sku":"LV481524","price":234.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-lv481524-fupact-gsc125-4p-fuse-switch-disconnector.png?v=1790869493"},{"product_id":"siemens-3np1123-1bc20-3np1-160a-3p-690v-fuse","title":"Siemens 3NP1123-1BC20 3NP1 160A 3P 690V Fuse","description":"\u003cp\u003eThe Siemens 3NP1123-1BC20 is a fuse switch disconnector from the SENTRON\/SIRIUS 3NP1 series. SENTRON, Fuse switch disconnector 3NP1, 3-pole, NH000, 160 A, for 8US busbar system 60 mm, box terminal, Cover level 32\/70 mm. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3NP1123-1BC20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3NP1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse switch disconnector\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBusbar design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ebusbar thickness 5 or 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the safety monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the load switch strip form\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of the driving mechanism motor drive\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor 60 mm 8US busbar system\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize of disconnecting link\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize of fuse link\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNH000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLet-through current with closed switch maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical service life (operating cycles) typical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI2t value with closed switch maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e223 kA²·s\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC-22 B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAt AC-23 B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWith capacitive load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-0.25\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuse system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLV HRC fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of pollution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.926 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3NP1123-1BC20 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 3NP1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619871256859,"sku":"3NP1123-1BC20","price":90.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-3np1123-1bc20.webp?v=1784367541"}],"url":"https:\/\/stoklink.com\/collections\/fuse-switch-disconnectors.oembed?page=12","provider":"Stoklink","version":"1.0","type":"link"}