{"title":"DC UPS \u0026 Buffer Modules","description":"\u003cp\u003eDC UPS and buffer modules from Siemens, with over 30 SITOP products that keep 24 V DC controls running when the mains fails. The range covers SITOP UPS1600, UPS500S and UPS1100 modules and BAT battery modules for currents from about 4 A to 40 A. Stoklink ships worldwide from Turkey and quotes project quantities on request.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSITOP UPS1600 DC UPS modules, for example 24 V DC at 20 A and 40 A, with USB or PROFINET.\u003c\/li\u003e\n\u003cli\u003eSITOP UPS500S and UPS501S compact modules.\u003c\/li\u003e\n\u003cli\u003eSITOP BAT battery modules, including LiFePO4 types such as 24 V at 7.5 Ah.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLoad current: the module must cover the full 24 V DC load.\u003c\/li\u003e\n\u003cli\u003eBuffer time: size the battery or storage module for the required ride-through.\u003c\/li\u003e\n\u003cli\u003eDiagnostics: USB or PROFINET lets the controller monitor battery status.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eWhat does a DC UPS do that a normal supply cannot?\u003c\/h3\u003e\u003cp\u003eIt switches to a battery when mains fails, so the 24 V DC load keeps running.\u003c\/p\u003e\u003ch3\u003eDo I need a separate battery module?\u003c\/h3\u003e\u003cp\u003eMost DC UPS modules need an external battery module. Check the datasheet for the exact type.\u003c\/p\u003e\u003ch3\u003eCan you ship to the Middle East or Africa?\u003c\/h3\u003e\u003cp\u003eYes. Stoklink ships worldwide from Turkey under EXW terms.\u003c\/p\u003e","products":[{"product_id":"siemens-6ep1931-2dc21-sitop-dc-ups-module","title":"Siemens 6EP1931-2DC21 SITOP DC UPS Module 24V\/6A DIN Rail No Interface","description":"\u003cp\u003eThe Siemens 6EP1931-2DC21 is a SITOP DC UPS module that buffers a 24 V DC bus at 6 A, drawing 24 V\/6.85 A on the input side to power the load and charge an external battery module at the same time. It has no communication interface, mounts on a 50 mm-wide DIN rail, and switches to battery backup at an adjustable 22-25.5 V threshold with a 1 s startup delay when the incoming supply drops.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrder Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP1931-2DC21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V rated (22...29 V range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A rated (plus approx. 0.6 A with empty battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffer Threshold (adjustable)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22...25.5 V in 0.5 V steps, preset 22.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC, normal and buffering mode (Vin minus approx. 0.5 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A rated (0...6 A, normal and buffering mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStartup Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 s typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% normal operation, 94.5% on battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 W typical (normal), 8 W typical (on battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupplied Active Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e144 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharging Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 A \/ 0.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReverse polarity (input and battery), output short-circuit proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 \/ Class III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...+60C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Dimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 x 125 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x7.5\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,085,776 h at 40C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eShipbuilding\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eWithout a communication interface, the 6EP1931-2DC21 handles buffering autonomously through its floating relay contacts (Bat\/OK and Alarm\/Bat) rather than reporting status over a serial link, so it suits installations where the 24 V OK \/ battery-in-use signal only needs to drive an indicator lamp or a digital input on a separate I\/O module. The buffer threshold is adjustable from 22 to 25.5 V in 0.5 V steps, letting the switchover point be set above the normal supply's minimum tolerance so the module engages before a marginal PLC power dip. At 6 A output it draws 6.85 A on the input to power the load and charge the battery at the same time, so the upstream 24 V supply needs headroom beyond the 6 A load current.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960761737499,"sku":"6EP1931-2DC21","price":221.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep1931-2dc21-sitop-dc-ups-module.png?v=1789779992"},{"product_id":"siemens-6ep1931-2dc31-sitop-dc-ups-module","title":"Siemens 6EP1931-2DC31 SITOP DC UPS Module 24V\/6A DIN Rail Serial Interface","description":"\u003cp\u003eThe Siemens 6EP1931-2DC31 is a SITOP DC UPS module that buffers a 24 V DC bus at 6 A and adds a serial PC interface for status monitoring, drawing 24 V\/6.85 A on the input side to power the load and charge an external battery module at the same time. It mounts on a 50 mm-wide DIN rail and switches to battery backup at an adjustable 22-25.5 V threshold with a 1 s startup delay when the incoming supply drops.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrder Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP1931-2DC31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V rated (22...29 V range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A rated (plus approx. 0.6 A with empty battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffer Threshold (adjustable)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22...25.5 V in 0.5 V steps, preset 22.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC, normal and buffering mode (Vin minus approx. 0.5 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A rated (0...6 A, normal and buffering mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStartup Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 s typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% normal operation, 94.5% on battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 W typical (normal), 8 W typical (on battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupplied Active Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e144 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharging Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 A \/ 0.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial, PC interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReverse polarity (input and battery), output short-circuit proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 \/ Class III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...+60C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Dimensions (WxHxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 x 125 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x7.5\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e966,183 h at 40C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eShipbuilding\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe serial PC interface is the difference from the no-interface model in the same SITOP DC UPS pair: it lets a PC or PLC read battery status and buffering state directly instead of relying only on the floating relay contacts (Bat\/OK and Alarm\/Bat) for a lamp or digital input. The buffer threshold is adjustable from 22 to 25.5 V in 0.5 V steps, letting the switchover point be set above the normal supply's minimum tolerance so the module engages before a marginal PLC power dip. At 6 A output it draws 6.85 A on the input to power the load and charge the battery at the same time, so the upstream 24 V supply needs headroom beyond the 6 A load current.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960761803035,"sku":"6EP1931-2DC31","price":283.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep1931-2dc31-sitop-dc-ups-module.png?v=1789779998"},{"product_id":"siemens-6ep1931-2dc42-sitop-dc-ups-24v-6a-usb","title":"Siemens 6EP1931-2DC42 SITOP DC UPS 24V\/6A USB Interface DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP1931-2DC42 is a SITOP DC UPS module rated 24 V DC \/ 6 A output, drawing 22...29 V DC \/ 6 A at the input, that bridges mains power cuts with a connected battery module. It reaches 95% efficiency at rated output and adds a USB interface for status and configuration on top of floating relay contacts.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP1931-2DC42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 ... 29 V DC (24 V DC rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current at 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A (+ approx. 0.6 A with empty battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage, Normal Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage, Buffering Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 ... 28.5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStartup Delay Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 s (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 ms (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency at Rated Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency on Battery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e94.5% (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss at Rated Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupplied Active Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e144 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Short-Circuit Proof\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput and battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 ... +60 degC (natural convection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 x 125 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x7.5\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF at 40 degC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e904159 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the 6 A member of the SITOP DC UPS family with a USB interface, which lets a PC log battery status and set the buffer response voltage instead of relying on the floating relay contacts alone. Pick the serial-interface variant if the downstream controller reads status over RS-232 rather than USB, or a higher-current variant in the same family when the load draws more than 6 A. The 1 s startup delay and 60 ms voltage rise time matter when sizing the module ahead of PLCs or drives that need a stable 24 V rail before they boot.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eBridges the 24 V DC control supply for PLCs, remote I\/O, and HMI panels through short mains interruptions until standby generators start or the supply recovers, using a separately ordered battery module for energy storage.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960761835803,"sku":"6EP1931-2DC42","price":283.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep1931-2dc42-sitop-dc-ups-24v-6a-usb.png?v=1789780005"},{"product_id":"siemens-6ep1931-2ec21-sitop-dc-ups-module","title":"Siemens 6EP1931-2EC21 SITOP DC UPS Module 24 V DC\/15 A DC UPS Module","description":"\u003cp\u003eThe Siemens SITOP 6EP1931-2EC21 is a 24 V DC uninterruptible power supply module rated for 15 A output current, drawing a 24 V\/16 A DC input and bridging the connected load through an external battery module during a mains interruption. It reaches 96.2% efficiency at rated output and switches from mains to battery automatically once the input voltage falls below its adjustable 22-25.5 V threshold.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP1931-2EC21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (22...29 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A rated (+approx. 1 A with empty battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (normal and buffering mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A rated, 0...15 A range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffer Connection Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22...25.5 V, adjustable in 0.5 V steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency (rated output)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96.2% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency (battery operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStartup Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 s typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20, Class III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...+60 degrees C, natural convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x7.5\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 x 125 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF (40 degrees C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e791,139 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eShipbuilding\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the 15 A-class module in the SITOP DC UPS line, sized for continuous loads up to 15 A, with the extra 1 A of input headroom reserved for battery charging rather than the load. It has no communication interface (design of interface: without), so status is read only through the floating relay contacts for OK, Alarm, and Bat\u0026gt;85% rather than over a network — choose the Ethernet\/PROFINET SITOP UPS1600 instead when remote diagnostics are required. The 22-25.5 V adjustable buffer threshold, set in 0.5 V steps, lets the switch-to-battery point be tuned ahead of a downstream PLC's own undervoltage cutoff.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003ePLC and control-rack power backup for critical loops, short mains-dropout ride-through on production lines, and bridging power during automatic transfer switch operation.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960761868571,"sku":"6EP1931-2EC21","price":267.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep1931-2ec21-sitop-dc-ups-module.png?v=1789681008"},{"product_id":"siemens-6ep1931-2ec31-sitop-dc-ups-24v-15a-serial","title":"Siemens 6EP1931-2EC31 SITOP DC UPS 24V\/15A Serial Interface DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP1931-2EC31 is a SITOP DC UPS module rated 24 V DC \/ 15 A output, drawing 22...29 V DC \/ 16 A at the input, that bridges mains power cuts with a connected battery module. It reaches 96.2% efficiency at rated output and adds a serial interface for status and configuration on top of floating relay contacts.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP1931-2EC31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 ... 29 V DC (24 V DC rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current at 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A (+ approx. 1 A with empty battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage, Normal Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage, Buffering Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 ... 28.5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStartup Delay Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 s (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 ms (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency at Rated Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96.2% (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency on Battery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96% (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss at Rated Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupplied Active Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e360 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Short-Circuit Proof\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput and battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 ... +60 degC (natural convection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 x 125 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x7.5\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF at 40 degC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e725689 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the 15 A member of the SITOP DC UPS family with a serial interface, useful where the supervising controller already polls status over RS-232\/RS-485 instead of USB. Choose the USB-interface 15 A variant if the host is a PC, or the 6 A or 40 A variants in the same family when the load current differs. The 96.2% efficiency and 14 W power loss at rated output keep enclosure heat load low compared to the 6 A module scaled up, and the 1 s startup delay should be accounted for when sequencing downstream 24 V loads.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eBridges the 24 V DC control supply for PLCs, remote I\/O, and HMI panels through short mains interruptions until standby generators start or the supply recovers, using a separately ordered battery module for energy storage.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960761901339,"sku":"6EP1931-2EC31","price":334.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep1931-2ec31-sitop-dc-ups-24v-15a-serial.png?v=1789780010"},{"product_id":"siemens-6ep1931-2ec42-sitop-dc-ups-24v-15a-usb","title":"Siemens 6EP1931-2EC42 SITOP DC UPS 24V\/15A USB Interface DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP1931-2EC42 is a SITOP DC UPS module rated 24 V DC \/ 15 A output, drawing 22...29 V DC \/ 16 A at the input, that bridges mains power cuts with a connected battery module. It reaches 96.2% efficiency at rated output and adds a USB interface for status and configuration on top of floating relay contacts.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP1931-2EC42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 ... 29 V DC (24 V DC rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current at 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A (+ approx. 1 A with empty battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage, Normal Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage, Buffering Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 ... 28.5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStartup Delay Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 s (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 ms (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency at Rated Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96.2% (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency on Battery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96% (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss at Rated Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupplied Active Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e360 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Short-Circuit Proof\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput and battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 ... +60 degC (natural convection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 x 125 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x7.5\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF at 40 degC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690131 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the 15 A member of the SITOP DC UPS family with a USB interface, which lets a PC log battery status and set the buffer response voltage instead of relying on the floating relay contacts alone. Pick the serial-interface 15 A variant if the downstream controller reads status over RS-232 rather than USB, or the 6 A or 40 A variants in the same family when the load current differs. The 96.2% efficiency and 14 W power loss at rated output keep enclosure heat load low, and the 1 s startup delay should be accounted for when sequencing downstream 24 V loads.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eBridges the 24 V DC control supply for PLCs, remote I\/O, and HMI panels through short mains interruptions until standby generators start or the supply recovers, using a separately ordered battery module for energy storage.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960761934107,"sku":"6EP1931-2EC42","price":334.8,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep1931-2ec42-sitop-dc-ups-24v-15a-usb.png?v=1789780016"},{"product_id":"siemens-6ep1931-2fc21-sitop-dc-ups-24v-40a","title":"Siemens 6EP1931-2FC21 SITOP DC UPS 24V\/40A No Interface DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP1931-2FC21 is a SITOP DC UPS module rated 24 V DC \/ 40 A output, drawing 22...29 V DC \/ 43 A at the input, that bridges mains power cuts with a connected battery module. It has no PC interface and relies on LED status indicators and floating relay contacts, reaching 97.2% efficiency at rated output.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP1931-2FC21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 ... 29 V DC (24 V DC rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current at 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43 A (+ approx. 2.6 A with empty battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage, Normal Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage, Buffering Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 ... 28.5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStartup Delay Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 s (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e360 ms (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency at Rated Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97.2% (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency on Battery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96.9% (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss at Rated Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.6 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupplied Active Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e960 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput and battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 ... +60 degC (natural convection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e102 x 125 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x7.5\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF at 40 degC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e522739 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the 40 A member of the SITOP DC UPS family without a PC interface, sized for the wider enclosure (102 mm vs 50 mm) that the higher current demands. Choose the USB-interface 40 A variant instead when a PC needs to log battery status or set the buffer voltage, or the 6 A or 15 A variants in the same family for smaller loads. At 40 A the module draws 43 A at the input and dissipates 28.6 W at rated output, so enclosure ventilation and adjacent-module spacing matter more than on the smaller variants.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eBridges the 24 V DC control supply for PLCs, remote I\/O, and HMI panels through short mains interruptions until standby generators start or the supply recovers, using a separately ordered battery module for energy storage.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960761966875,"sku":"6EP1931-2FC21","price":483.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep1931-2fc21-sitop-dc-ups-24v-40a.png?v=1789780022"},{"product_id":"siemens-6ep1931-2fc42-sitop-dc-ups-24v-40a-usb","title":"Siemens 6EP1931-2FC42 SITOP DC UPS 24V\/40A USB Interface DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP1931-2FC42 is a SITOP DC UPS module rated 24 V DC \/ 40 A output, drawing 22...29 V DC \/ 42.6 A at the input, that bridges mains power cuts with a connected battery module. It reaches 97.2% efficiency at rated output and adds a USB interface for status and configuration on top of floating relay contacts.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP1931-2FC42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC UPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 ... 29 V DC (24 V DC rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current at 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A (+ approx. 2.6 A with empty battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage, Normal Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage, Buffering Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19 ... 28.5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStartup Delay Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 s (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e360 ms (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency at Rated Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97.2% (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency on Battery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96.9% (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss at Rated Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.6 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupplied Active Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e960 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput and battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 ... +60 degC (natural convection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e102 x 125 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x7.5\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF at 40 degC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e493340 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the 40 A member of the SITOP DC UPS family with a USB interface, which lets a PC log battery status and set the buffer response voltage instead of relying on the floating relay contacts alone. Choose the interface-free 40 A variant when no PC connection is needed, or the 6 A or 15 A variants in the same family for smaller loads. At 40 A the module draws 42.6 A at the input and dissipates 28.6 W at rated output, so enclosure ventilation and adjacent-module spacing matter more than on the smaller variants.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eBridges the 24 V DC control supply for PLCs, remote I\/O, and HMI panels through short mains interruptions until standby generators start or the supply recovers, using a separately ordered battery module for energy storage.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960762032411,"sku":"6EP1931-2FC42","price":549.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep1931-2fc42-sitop-dc-ups-24v-40a-usb.png?v=1789780029"},{"product_id":"siemens-6ep1933-2ec41-sitop-ups500s-dc-ups-module","title":"Siemens 6EP1933-2EC41 SITOP UPS500S 24V DC\/15A 2.5kWs DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP1933-2EC41 SITOP UPS500S is a maintenance-free DC uninterruptible power supply module that bridges 24 V DC power interruptions using an internal capacitor energy store. Rated for 24 V DC input and 15 A output, it holds a 2.5 kWs energy reserve — enough to sustain full load for 3 seconds or a reduced load for up to 38 seconds — and reports status through a USB interface and floating relay contacts.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP1933-2EC41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS500S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4025515152392\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 ... 29 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC ± 3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnergy Content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kWs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBridging Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A for 3 s \/ 10 A for 6 s \/ 5 A for 15 s \/ 2 A for 38 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (Operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 x 125 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eShipbuilding\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 15 A bridging rating covers three distinct scenarios rather than a single number: full 15 A load for 3 s, a reduced 10 A draw for 6 s, or 5 A for 15 s — the actual ride-through time depends on how much of the 15 A output the connected load draws. Applications needing longer coverage than the onboard 2.5 kWs capacitor bank provides can add an extension module instead of stepping up to a larger UPS. The USB interface plus floating OK\/ALARM\/BAT\u0026gt;85% contacts let the module report buffering state to a PLC without extra I\/O wiring beyond the existing 24 V DC distribution.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eBridges short 24 V DC control-power interruptions for PLCs, remote I\/O stations, and network switches during mains transfer or brief supply dips, where a battery-based UPS would be oversized for a sub-minute ride-through requirement.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960762065179,"sku":"6EP1933-2EC41","price":445.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep1933-2ec41-sitop-ups500s-dc-ups-module.png?v=1789680477"},{"product_id":"siemens-6ep1933-2ec51-sitop-ups500s-24v-15a-5kws","title":"Siemens 6EP1933-2EC51 SITOP UPS500S 24V\/15A 5kWs USB DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP1933-2EC51 is a SITOP UPS500S basic unit, a maintenance-free capacitor-based DC UPS rated 24 V DC \/ 15 A output with a 5 kWs energy store, drawing 15.2 A at the 24 V DC input. It bridges 15 A for 9 s (or 5 A for 31 s) without a battery and adds a USB interface for status and configuration.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP1933-2EC51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS500S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUPS500S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnergy Storage Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapacitors (5 kW.s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMains Buffering Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A for 9 s \/ 10 A for 15 s \/ 5 A for 31 s \/ 2 A for 76 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 ... 29 V DC (24 V DC rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current at 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.2 A (+ approx. 2.3 A with empty capacitor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage, Normal Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage, Buffering Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 ... 24.7 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStartup Delay Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 s (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Rise Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 ms (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency at Rated Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97.5% (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss at Rated Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupplied Active Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e360 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Short-Circuit Proof\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput and energy storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... +60 degC (natural convection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 x 125 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x7.5\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF at 40 degC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e459137 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the basic UPS500S unit with a 5 kWs capacitor store, USB interface, and 15 A rated output, aimed at bridges measured in seconds rather than minutes: 15 A for 9 s or 5 A for 31 s. Because it uses capacitors, not a lead-acid battery module, there is no periodic battery replacement and the 97.5% efficiency exceeds the battery-based SITOP DC UPS modules. Add the SITOP UPS501S extension module when the application needs a longer buffering time than the basic unit alone provides.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eBridges brief 24 V DC dropouts for PLCs, drives, and remote I\/O during supply switchover or short interruptions, where a maintenance-free capacitor store is preferred over a lead-acid battery.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960762097947,"sku":"6EP1933-2EC51","price":567.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep1933-2ec51-sitop-ups500s-24v-15a-usb.png?v=1789780035"},{"product_id":"siemens-6ep1935-5pg01-sitop-ups501s-expansion-module","title":"Siemens 6EP1935-5PG01 SITOP UPS501S 5 kWs Capacitor Expansion Module DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP1935-5PG01 is a SITOP UPS501S expansion module that adds 5 kWs of capacitor-based energy storage to a SITOP UPS500S or UPS501S DC UPS system. It has no independent input or output rating of its own, mounts on a 35 mm DIN rail, and plugs directly into the UPS module via its output connection system, in an IP20, Class III enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU (MLFB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP1935-5PG01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS501S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUPS501, extension module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of Energy Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapacitors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnergy Content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kW.s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection at Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-in system to SITOP UPS500S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF at 40 degC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350,000 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 x 125 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSnaps onto DIN rail EN 60715 35x7.5\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...60 degC, natural convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage\/Transport Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis module only extends stored energy capacity for a SITOP UPS500S\/UPS501S front-end; it does not connect directly to line power or a load on its own, so it must be paired with a UPS500S or UPS501S base unit rated for it. Use it where the base UPS module's onboard buffering is not enough to ride through the required bridging time at full load.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eFits SITOP DC UPS installations protecting PLCs, drives, or control panels against short mains interruptions, where the standard UPS500S\/UPS501S buffering time needs to be extended without adding a battery-based module.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960762130715,"sku":"6EP1935-5PG01","price":384.3,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep1935-5pg01-sitop-ups501s-expansion-module.png?v=1789714123"},{"product_id":"siemens-6ep1935-6mc01-sitop-battery-module-24v-1-2ah","title":"Siemens 6EP1935-6MC01 SITOP Battery Module 24V\/1.2Ah Power Supply Buffer Module","description":"\u003cp\u003eThe Siemens 6EP1935-6MC01 is a SITOP battery module with a 1.2 Ah maintenance-free lead-acid battery pack rated 24 V DC, sized for the SITOP DC UPS 6 A module. It supplies up to 3.6 A in buffering mode and 7.5 A peak, and mounts on the same DIN rail as its host UPS module or onto a wall via keyhole mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP1935-6MC01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP battery module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery module 1.2 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free lead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 A.h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current, Buffering Mode (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharging Current (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery fuse 7.5 A \/ 32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eValve control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpring-loaded terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15 ... +50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Life at 20 degC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 years (typical, 80% capacity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96 x 106 x 108 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x7.5\/15 or wall mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecURus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eMatch this 1.2 Ah module to the SITOP DC UPS 6 A module: its 3.6 A buffering current and 7.5 A peak are sized for that load, not the 15 A or 40 A UPS modules in the family, which need the 3.2 Ah or larger battery modules for a comparable runtime. Because the cells are maintenance-free lead-acid rather than pure-lead, expect the typical 4-year service life at 20 degC to shorten to about 1 year at 40 degC, so battery replacement interval should track ambient temperature at the installation site, not a fixed calendar date.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960762163483,"sku":"6EP1935-6MC01","price":129.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep1935-6mc01-sitop-battery-module-24v-1-2ah.png?v=1789780041"},{"product_id":"siemens-6ep1935-6md11-sitop-battery-module-24v-3-2ah","title":"Siemens 6EP1935-6MD11 SITOP Battery Module 24V\/3.2Ah Power Supply Buffer Module","description":"\u003cp\u003eThe Siemens 6EP1935-6MD11 is a SITOP battery module with a 3.2 Ah maintenance-free lead-acid battery pack rated 24 V DC, sized for the SITOP DC UPS 6 A and 15 A modules. It supplies up to 9.6 A in buffering mode and 15 A peak, and mounts on the same DIN rail as its host UPS module or onto a wall via keyhole mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP1935-6MD11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP battery module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery module 3.2 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free lead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 A.h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current, Buffering Mode (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharging Current (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery fuse 15 A \/ 32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eValve control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpring-loaded terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15 ... +50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Life at 20 degC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 years (typical, 80% capacity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190 x 151 x 82 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x7.5\/15 or wall mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecURus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eMatch this 3.2 Ah module to the SITOP DC UPS 6 A or 15 A modules: its 9.6 A buffering current and 15 A peak cover both, whereas the 6 A-only 1.2 Ah module cannot support the 15 A UPS at full load. Step up to the 7 Ah module for the 40 A UPS module or where longer buffering time is required at 15 A. As with the other lead-acid modules in this family, the typical 4-year service life at 20 degC drops sharply at higher ambient temperature, so size the replacement interval to the installation's actual operating temperature.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960762229019,"sku":"6EP1935-6MD11","price":134.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep1935-6md11-sitop-battery-module-24v-3-2ah.png?v=1789780047"},{"product_id":"siemens-6ep1935-6md31-sitop-pure-battery-module-24v-2-5ah","title":"Siemens 6EP1935-6MD31 SITOP Pure Battery Module 24V\/2.5Ah Buffer Module","description":"\u003cp\u003eThe Siemens 6EP1935-6MD31 is a SITOP pure lead-acid battery module rated 24 V DC \/ 2.5 Ah, sized for the SITOP DC UPS 6 A and 15 A modules. Unlike the standard lead-acid modules in the family, its pure-lead cells tolerate -40...+60 degC and supply up to 15 A in buffering mode and 15 A peak.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP1935-6MD31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP battery module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery module 2.5 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free pure lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 A.h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current, Buffering Mode (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharging Current (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery fuse 15 A \/ 32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eValve control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpring-loaded terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Life at 20 degC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 years (typical, 80% capacity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e265 x 151 x 91 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x15 or wall mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecURus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick this pure-lead 2.5 Ah module over the standard 3.2 Ah lead-acid module when ambient temperature swings beyond the -15...+50 degC range that standard lead-acid cells tolerate, since pure lead extends operation down to -40 degC and up to +60 degC. Its 5 A maximum charging current is also higher than the standard modules', which shortens recharge time after a discharge event. The typical service life reaches 10 years at 20 degC versus 4 years for the standard lead-acid modules, though it still falls to about 1 year at 60 degC, so replacement planning should follow the actual site temperature.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960762261787,"sku":"6EP1935-6MD31","price":360.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep1935-6md31-sitop-pure-battery-module-24v-2-5ah.png?v=1789780053"},{"product_id":"siemens-6ep1935-6me21-sitop-battery-module-24v-7ah","title":"Siemens 6EP1935-6ME21 SITOP Battery Module 24V\/7Ah Power Supply Buffer Module","description":"\u003cp\u003eThe Siemens 6EP1935-6ME21 is a SITOP battery module with a 7 Ah maintenance-free lead-acid battery pack rated 24 V DC, sized for the SITOP DC UPS 6 A, 15 A, and 40 A modules. It supplies up to 30 A in buffering mode and 30 A peak, and mounts on a wall via keyhole mounting rather than snapping onto a DIN rail.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP1935-6ME21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP battery module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery module 7 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free lead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 A.h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current, Buffering Mode (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharging Current (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.75 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery fuse 20 A \/ 32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eValve control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpring-loaded terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15 ... +50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Life at 20 degC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 years (typical, 80% capacity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 x 168 x 121 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastening Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall mount (keyhole for M4 screws)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecURus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the largest battery module in the SITOP family, covering the 6 A, 15 A, and 40 A DC UPS modules where the 3.2 Ah and 2.5 Ah modules only reach up to 15 A. Its 30 A buffering current and peak current are what make the 40 A UPS module usable at full load. Unlike the smaller battery modules, it is wall-mounted rather than DIN-rail snap-on, which should be accounted for in enclosure layout given its 6 kg weight and larger 186 x 168 x 121 mm footprint.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960762327323,"sku":"6EP1935-6ME21","price":167.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep1935-6me21-sitop-battery-module-24v-7ah.png?v=1789780059"},{"product_id":"siemens-6ep1935-6mf01-sitop-battery-module","title":"Siemens 6EP1935-6MF01 SITOP Battery Module 24V 12Ah Maintenance-Free DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP1935-6MF01 is a SITOP battery module with 24 V\/12 Ah maintenance-free sealed lead-acid batteries, built to extend runtime on the SITOP DC UPS modules rated 6 A, 15 A and 40 A. It delivers up to 30 A in buffering mode and up to 30 A peak current, with a 20 A\/32 V battery fuse for short-circuit protection and a maximum 3 A charging current.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number\u003c\/td\u003e\n\u003ctd\u003e6EP1935-6MF01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSITOP battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eBattery module 12 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free lead-acid batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Capacity\u003c\/td\u003e\n\u003ctd\u003e12 A.h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current in Buffering Mode (max)\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Current\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Current (max)\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnd-of-Charge Voltage at 20 degC\u003c\/td\u003e\n\u003ctd\u003e27.3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eBattery fuse 20 A\/32 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eValve control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Resource Protection Class\u003c\/td\u003e\n\u003ctd\u003eClass III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation)\u003c\/td\u003e\n\u003ctd\u003e-15 ... +50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Storage)\u003c\/td\u003e\n\u003ctd\u003e-20 ... +50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 20 degC (typical)\u003c\/td\u003e\n\u003ctd\u003e4 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 30 degC (typical)\u003c\/td\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Dimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e253 x 168 x 121 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFastening Method\u003c\/td\u003e\n\u003ctd\u003eWall mounting, keyhole for M4 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Cells\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eShipbuilding\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis 12 Ah battery pairs with SITOP DC UPS modules across the 6 A, 15 A and 40 A range - verify buffering runtime against the connected UPS module's load rather than this module's 30 A output-current ceiling, which is a maximum, not a guaranteed runtime figure. The 20 A\/32 V battery fuse and Class III protection rating fix the safety boundary for the pack itself, and wall or flat-surface keyhole mounting keeps the 9 kg pack out of the UPS module's own footprint. Service life drops from 4 years at 20 degC to 2 years at 30 degC, so ambient temperature at the installation site is the main variable to check before setting replacement intervals.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as the battery back-up stage in SITOP DC UPS installations protecting PLCs, drives and control panels through mains interruptions, where the 6 A, 15 A or 40 A UPS module handles power management and this module supplies the stored 24 V DC energy.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960762360091,"sku":"6EP1935-6MF01","price":219.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep1935-6mf01-sitop-battery-module-dc-ups.png?v=1789780185"},{"product_id":"siemens-6ep4132-0gb00-0ay0-ups1100-24v-2-5ah-battery","title":"Siemens 6EP4132-0GB00-0AY0 SITOP UPS1100 24V\/2.5Ah Pure Lead Battery Module","description":"\u003cp\u003eThe Siemens 6EP4132-0GB00-0AY0 is a SITOP UPS1100 battery module with a maintenance-free, sealed pure lead-acid cell rated 24 V DC at 2.5 Ah. It extends the buffering time of a SITOP DC UPS module and delivers a peak current of 60 A for 30 ms during load transients. It snaps onto a DIN rail or mounts to a wall and weighs 3.7 kg.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6EP4132-0GB00-0AY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eBattery module 2.5 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free pure lead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Capacity\u003c\/td\u003e\n\u003ctd\u003e2.5 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e20 A rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Current\u003c\/td\u003e\n\u003ctd\u003e60 A for 30 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Charging Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Cells\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003e25 A\/32 V battery fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation)\u003c\/td\u003e\n\u003ctd\u003e-40 to +60 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 20 degrees C\u003c\/td\u003e\n\u003ctd\u003e10 years typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e265 x 115 x 76 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x7.5\/15 or wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e3.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecURus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 2.5 Ah capacity and 20 A rated output current pair this module with lower-current SITOP DC UPS units rather than 40 A loads, where a higher-capacity battery module would be needed. Service life drops sharply with heat, from 10 years typical at 20 degrees C to 1 year at 60 degrees C, so mounting location and cabinet ventilation matter more than the buffering time spec alone. DIN-rail snap-on or keyhole wall mounting gives two installation options in the same footprint.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960770617627,"sku":"6EP4132-0GB00-0AY0","price":349.2,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4132-0gb00-0ay0-sitop-ups1100-battery-module.png?v=1789780423"},{"product_id":"siemens-6ep4132-0ja00-0ay0-bat1600-24v-2-5ah-battery","title":"Siemens 6EP4132-0JA00-0AY0 SITOP BAT1600 24V\/2.5Ah LiFePO4 Battery Module","description":"\u003cp\u003eThe Siemens 6EP4132-0JA00-0AY0 is a SITOP BAT1600 battery module with a maintenance-free LiFePO4 lithium cell rated 24 V DC at 2.5 Ah, built for the SITOP UPS1600 platform. It supplies a rated output current of 10 A and a peak current of 45 A for 30 ms during buffering, with a single cell inside a 2 kg enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6EP4132-0JA00-0AY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSITOP BAT1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003e2.5 Ah Li\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free LiFePO4 rechargeable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Capacity\u003c\/td\u003e\n\u003ctd\u003e2.5 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e10 A rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Current\u003c\/td\u003e\n\u003ctd\u003e45 A for 30 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Charging Current\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Cells\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003e25 A\/32 V Maxi flat fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation)\u003c\/td\u003e\n\u003ctd\u003e-10 to +50 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 20 degrees C\u003c\/td\u003e\n\u003ctd\u003e11 years typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e89 x 156 x 129 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x15 or wall mounting kit 6EP4990-0MK00-0XU0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe single-cell LiFePO4 pack gives an 11-year typical service life at 20 degrees C versus a lead-acid module's 10 years, and it holds that life better up to 40 degrees C (8 years) where lead-acid degrades faster. The 10 A rated output current sizes this module for the lower-current SITOP UPS1600 units rather than the higher-current variants, which need a higher-capacity battery. Not approved for air freight, which affects logistics planning for remote installations.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960770650395,"sku":"6EP4132-0JA00-0AY0","price":517.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4132-0ja00-0ay0-sitop-bat1600-battery-module.png?v=1789780429"},{"product_id":"siemens-6ep4133-0ga00-0ay0-sitop-bat1600-24v-3-2ah","title":"Siemens 6EP4133-0GA00-0AY0 SITOP BAT1600 24V 3.2Ah Lead-Acid DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP4133-0GA00-0AY0 SITOP BAT1600 is a 24 V DC, 3.2 Ah maintenance-free lead-acid battery module for the SITOP UPS1600 buffering system, rated 20 A continuous output with a 60 A \/ 30 ms peak. Charging draws up to 0.8 A, and a three-color LED reports buffer-ready, buffer-endangered, or buffer-not-possible status.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP4133-0GA00-0AY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBAT1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free lead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput current, rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 A (30 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharging current, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnd-of-charge voltage at 20°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A \/ 32 V Maxi flat fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life at 20°C, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService life at 30°C, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15…+50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x15 or wall mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure dimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89 × 156 × 169 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003e3.2 Ah is the smallest capacity step in the BAT1600 module range, sized to buffer the lower output-current SITOP UPS1600 configurations rather than deliver long-runtime backup — pick a higher-Ah BAT1600 module where ride-through time matters more than footprint. The 4-year typical service life at 20°C drops to 1 year at 40°C, so cabinet ambient temperature directly sets the replacement interval and should be checked against the installation site. The built-in 25 A \/ 32 V fuse and three-color status LED let it report buffer health locally without a separate battery-monitoring module.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003e24 V buffering for PLCs and controllers behind a SITOP UPS1600, and short ride-through power-loss protection in machine control cabinets.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960770683163,"sku":"6EP4133-0GA00-0AY0","price":161.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4133-0ga00-0ay0-sitop-bat1600-battery-module.png?v=1789681073"},{"product_id":"siemens-6ep4134-0gb00-0ay0-sitop-ups1100-battery-7ah","title":"Siemens 6EP4134-0GB00-0AY0 SITOP UPS1100 24V DC 7Ah Battery Module DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP4134-0GB00-0AY0 SITOP UPS1100 battery module supplies 7 Ah of maintenance-free sealed lead-acid backup capacity at 24 V DC for SITOP DC UPS modules. It delivers up to 40 A of buffering current, 120 A for 30 ms peak, and communicates battery status over its built-in interface, in an IP20, Class III enclosure rated for -15 to +50 degC operation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU (MLFB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP4134-0GB00-0AY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS1100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery module 7 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free sealed lead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A rated, 40 A max in buffering mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 A for 30 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Charging Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.75 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x 25 A\/32 V blade-type fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, battery status interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 x 186 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15...+50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService Life at 20 degC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 years typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecURus\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eService life drops sharply with ambient temperature: rated 4 years typical at 20 degC, but only 1 year at 40 degC and 0.5 years at 50 degC, so cabinet ventilation directly affects replacement interval. The 40 A output current and 120 A\/30 ms peak rating size this module for higher-current DC UPS loads rather than small single-PLC backup, where a lower-capacity battery module would be adequate. It connects to the SITOP UPS1100 host module via screw terminals (0.5-16 mm² for +BAT\/-BAT), not a plug-in system.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eProvides ride-through backup for 24 V DC control systems, PLCs, and drives during mains interruptions in SITOP UPS1100-based installations, sized for loads that need sustained 40 A buffering current rather than momentary support.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960770715931,"sku":"6EP4134-0GB00-0AY0","price":170.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4134-0gb00-0ay0-sitop-ups1100-battery-7ah.png?v=1789714137"},{"product_id":"siemens-6ep4134-0ja00-0ay0-bat1600-24v-7-5ah-battery","title":"Siemens 6EP4134-0JA00-0AY0 SITOP BAT1600 24V\/7.5Ah LiFePO4 Battery Module","description":"\u003cp\u003eThe Siemens 6EP4134-0JA00-0AY0 is a SITOP BAT1600 battery module with a maintenance-free LiFePO4 lithium cell rated 24 V DC at 7.5 Ah, built for the SITOP UPS1600 platform. It supplies a rated output current of 40 A and a peak current of 120 A for 30 ms during buffering, with three cells inside a 4 kg enclosure.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6EP4134-0JA00-0AY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSITOP BAT1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003e7.5 Ah Li\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free LiFePO4 rechargeable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Capacity\u003c\/td\u003e\n\u003ctd\u003e7.5 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e40 A rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Current\u003c\/td\u003e\n\u003ctd\u003e120 A for 30 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Charging Current\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Cells\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003e50 A\/32 V Maxi flat fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation)\u003c\/td\u003e\n\u003ctd\u003e-10 to +50 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 20 degrees C\u003c\/td\u003e\n\u003ctd\u003e11 years typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e238 x 156 x 129 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x15 or wall mounting kit 6EP4990-0MK00-0XU0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 40 A rated output and 120 A\/30 ms peak current make this the module for higher-draw SITOP UPS1600 units, well above the entry 2.5 Ah\/10 A variant in the same LiFePO4 line. Three lithium cells replace one on the smaller module, which is why net weight rises to 4 kg despite the shared chemistry. As with the smaller BAT1600, it is not approved for air freight. Charging current tops out at 3 A regardless of capacity, so a full recharge after a deep discharge takes longer on this larger pack than the runtime gain alone would suggest.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960772550939,"sku":"6EP4134-0JA00-0AY0","price":966.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4134-0ja00-0ay0-sitop-bat1600-battery-module.png?v=1789780436"},{"product_id":"siemens-6ep4134-3ab00-0ay0-sitop-ups1600-24v-10a","title":"Siemens 6EP4134-3AB00-0AY0 SITOP UPS1600 24V\/10A DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP4134-3AB00-0AY0 is a SITOP UPS1600 DC uninterruptible power supply rated 24V DC \/ 10A output, buffering a 24V DC input with an external battery module. It delivers up to 97.5% efficiency, a 60 millisecond output startup delay, and adjustable buffering time from 0.5 to 20 minutes via a rotary switch.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog No \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP4134-3AB00-0AY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUPS1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of current supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC UPS 24 V \/ 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput voltage, rated \/ range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC \/ 21 to 29 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput voltage, normal operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput voltage, buffering mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.5 to 27 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput current, rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput current range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupplied active power, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffering time, adjustable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 to 20 min (rotary switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput startup delay, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, self-protecting output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput and battery module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class \/ IP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass III \/ IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 x 139 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x7.5\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF at 40 degC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415,574 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus (UL 508)\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe adjustable buffering time, 0.5 to 20 minutes via rotary switch, lets the same UPS1600 module cover both a short ride-through for momentary dips and a longer bridge to controlled shutdown, depending on the connected battery module capacity — size the battery to the selected time, not the module itself. At 10 A rated output (30 A peak, short-circuit protected), it fits control cabinets where the 24V DC bus needs continuous power through brief mains interruptions without a full battery UPS redesign. Marine classification (ABS, DNV) makes this variant suitable for shipboard control panels where a standard industrial power supply lacks that approval.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eBuffers the 24V DC control bus for PLCs, HMIs, and I\/O in control cabinets against short power interruptions — process plants, machine tools, and marine or offshore panels needing ride-through before generator or utility power returns.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960772616475,"sku":"6EP4134-3AB00-0AY0","price":238.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4134-3ab00-0ay0-sitop-ups1600-24v-10a.png?v=1789679401"},{"product_id":"siemens-6ep4134-3ab00-1ay0-sitop-ups1600-24v-10a-usb","title":"Siemens 6EP4134-3AB00-1AY0 SITOP UPS1600 24V\/10A USB DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP4134-3AB00-1AY0 is a SITOP UPS1600 DC uninterruptible power supply module rated 24 V DC at 10 A with a USB interface. It buffers a 21-29 V DC input against short-circuits and delivers 97.5% efficiency in both normal and battery-buffered operation, with buffering time adjustable from 0.5 to 20 minutes via rotary switch.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6EP4134-3AB00-1AY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e21 - 29 V DC, rated 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (normal and buffering mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e10 A rated, 0 - 30 A normal\/buffering range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Current\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e97.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e6 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied Power\u003c\/td\u003e\n\u003ctd\u003e240 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffering Time Setting\u003c\/td\u003e\n\u003ctd\u003e0.5 - 20 min adjustable via rotary switch or software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eShort-circuit proof, reverse polarity protected on input and battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF at 40 degrees C\u003c\/td\u003e\n\u003ctd\u003e364153 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation)\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e50 x 139 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x7.5\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 10 A rated output this is the entry current rating in the SITOP UPS1600 line, sized for smaller 24 V control loops rather than the 20 A or 40 A modules in the same family. The rotary-switch buffering window from 0.5 to 20 minutes lets the same hardware cover both a brief ride-through for PLC memory retention and a longer shutdown sequence for a controlled process stop. The USB interface differentiates it from the Ethernet\/PROFINET variant, favoring local configuration and diagnostics over networked monitoring.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960772649243,"sku":"6EP4134-3AB00-1AY0","price":295.2,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4134-3ab00-1ay0-sitop-ups1600-dc-ups-module.png?v=1789780442"},{"product_id":"siemens-6ep4134-3ab00-2ay0-sitop-ups1600-profinet","title":"Siemens 6EP4134-3AB00-2AY0 SITOP UPS1600 24 V\/10 A PROFINET DC UPS","description":"\u003cp\u003eThe Siemens SITOP UPS1600 6EP4134-3AB00-2AY0 is a 24 V DC uninterruptible power supply rated for 10 A output (30 A peak), with an integrated Ethernet\/PROFINET interface, OPC UA server, and web server for remote monitoring. Buffering time is adjustable from 0.5 to 20 minutes via rotary switch or software, and the unit reaches 97.3% efficiency at rated output.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP4134-3AB00-2AY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (21...29 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 A rated (for max. 3 A charging current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (normal and buffering mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A rated, 0...30 A range, 30 A peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffering Time (adjustable)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 \/ 1 \/ 2 \/ 5 \/ 10 \/ 20 min or via software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency (rated output)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97.3% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet \/ PROFINET, 2 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOPC UA server, web server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20, Class III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...+70 degrees C, natural convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 x 139 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.44 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF (40 degrees C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e349,874 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eShipbuilding\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe Ethernet\/PROFINET interface with OPC UA and web server is what separates the UPS1600 from the interface-less SITOP DC UPS module in the same catalog — pick it when battery state, remaining buffering time, or alarm status needs to be visible to a PLC over PROFINET or a browser dashboard rather than read only from panel LEDs and relay contacts. Its 30 A peak\/10 A rated output and buffering adjustable up to 20 minutes suit loads needing longer ride-through than a fixed-threshold DC UPS module, at the cost of a higher 14 A input draw reserved for battery charging.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003ePROFINET-networked control cabinets needing remote UPS diagnostics, critical process loads requiring extended ride-through, and OPC UA-integrated condition monitoring of backup power status.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960772682011,"sku":"6EP4134-3AB00-2AY0","price":371.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4134-3ab00-2ay0-sitop-ups1600-dc-ups.png?v=1789681080"},{"product_id":"siemens-6ep4135-0ge00-0ay0-sitop-bat1600-battery-module","title":"Siemens 6EP4135-0GE00-0AY0 SITOP BAT1600 24V DC 12Ah Lead-Acid Battery Module for UPS1600","description":"\u003cp\u003eSiemens 6EP4135-0GE00-0AY0 is a SITOP BAT1600 battery module for the SITOP UPS1600 system, containing a maintenance-free 24 V DC, 12 Ah sealed lead-acid battery. It delivers a rated output current of 40 A, a 120 A peak for 30 ms, and a maximum charging current of 3 A, with short-circuit protection via a 50 A\/32 V fuse.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder No. (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6EP4135-0GE00-0AY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eBAT1600, 12 Ah Pb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free lead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Capacity\u003c\/td\u003e\n\u003ctd\u003e12 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage, rated\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current, rated\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Current\u003c\/td\u003e\n\u003ctd\u003e120 A for 30 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Current, max.\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003e50 A \/ 32 V Maxi flat fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 20C, typ.\u003c\/td\u003e\n\u003ctd\u003e4 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 30C, typ.\u003c\/td\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 40C, typ.\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, operation\u003c\/td\u003e\n\u003ctd\u003e-15C to +50C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, storage\u003c\/td\u003e\n\u003ctd\u003e-20C to +40C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Cells\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFastening\u003c\/td\u003e\n\u003ctd\u003eWall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e225 mm x 156 mm x 138 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight (mechanical data)\u003c\/td\u003e\n\u003ctd\u003e10.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eShipbuilding\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 12 Ah capacity and 4-year typical service life at 20C set the buffering window for connected loads; that service life falls to 2 years at 30C and 1 year at 40C, so replacement intervals should follow actual cabinet ambient temperature rather than the nominal 4-year figure. The 120 A\/30 ms peak rating covers inrush current at UPS transfer, and the 50 A\/32 V fuse sets the practical output short-circuit protection level for the module.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eBattery backup for SITOP UPS1600-based 24 V DC bus supplies, bridging brief mains interruptions for PLC and controller loads, and marine or offshore 24 V UPS installations covered by ABS shipbuilding approval.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960772714779,"sku":"6EP4135-0GE00-0AY0","price":273.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4135-0ge00-0ay0-sitop-bat1600-battery-module.png?v=1789679937"},{"product_id":"siemens-6ep4136-3ab00-0ay0-sitop-ups1600-24vdc-20a-dc-ups","title":"Siemens 6EP4136-3AB00-0AY0 SITOP UPS1600 24V DC 20A Uninterruptible Supply","description":"\u003cp\u003eThe Siemens 6EP4136-3AB00-0AY0 is a SITOP UPS1600 DC uninterruptible power supply module rated 24 V DC at 20 A, providing 21-29 V input buffering with an adjustable cut-in threshold and a rotary-switch-selectable backup time from 0.5 to 20 minutes. It delivers up to 60 A peak, runs at 97.7% efficiency with 10 W typical power loss, and carries an IP20 rating in a compact 50 x 139 x 125 mm DIN-rail enclosure weighing 0.39 kg.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP4136-3AB00-0AY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21-29 V DC (24 V DC rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage, Normal \/ Buffering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC \/ 18.5-27 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current, Rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A, 0-60 A range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharging Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1-4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCut-in Threshold, Adjustable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21-25 V DC, 7 steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackup Time, Adjustable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5\/1\/2\/5\/10\/20 min or max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupplied Power, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e480 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 x 139 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.39 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF at 40 C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e408,654 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSelection Notes\u003c\/h2\u003e\n\u003cp\u003eThe rotary-coded backup-time switch (0.5 to 20 minutes, or maximum) sets how long the 24 V rail rides through a supply interruption before the connected battery module is exhausted, letting the same UPS1600 serve either a quick-ride-through role or a full shutdown-sequence role without reprogramming. The adjustable cut-in threshold (21-25 V in seven steps) lets it buffer only on a genuine dip rather than normal ripple from a lightly loaded 24 V supply. At 20 A rated and 60 A peak, it covers inrush from contactors and solenoids during the switchover without derating the connected battery module.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eUsed to bridge short mains interruptions for PLCs, I\/O, and drives on a 24 V DC bus in control cabinets where an orderly shutdown or ride-through is required instead of an immediate loss of power.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960772780315,"sku":"6EP4136-3AB00-0AY0","price":280.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4136-3ab00-0ay0-sitop-ups1600-24vdc-20a-dc-ups.png?v=1789678468"},{"product_id":"siemens-6ep4136-3ab00-1ay0-sitop-ups1600-24v-20a-usb","title":"Siemens 6EP4136-3AB00-1AY0 SITOP UPS1600 24V\/20A USB DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP4136-3AB00-1AY0 is a SITOP UPS1600 DC uninterruptible power supply module rated 24 V DC at 20 A with a USB interface. It buffers a 21-29 V DC input against short-circuits and delivers 97.7% efficiency in both normal and battery-buffered operation, with buffering time adjustable from 0.5 to 20 minutes via rotary switch.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6EP4136-3AB00-1AY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e21 - 29 V DC, rated 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (normal and buffering mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e20 A rated, 0 - 60 A normal\/buffering range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Current\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e97.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e10 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied Power\u003c\/td\u003e\n\u003ctd\u003e480 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffering Time Setting\u003c\/td\u003e\n\u003ctd\u003e0.5 - 20 min adjustable via rotary switch or software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eShort-circuit proof, reverse polarity protected on input and battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF at 40 degrees C\u003c\/td\u003e\n\u003ctd\u003e358897 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation)\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e50 x 139 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x7.5\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.41 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 20 A rating sits in the middle of the SITOP UPS1600 range, doubling the entry 10 A module's throughput in the same enclosure footprint while adding only 0.01 kg. The 60 A peak current and 0-60 A buffering range accommodate inrush-heavy loads that would trip the smaller module's 30 A limit. Like the 10 A variant, buffering time is field-adjustable from 0.5 to 20 minutes, and the USB interface handles local configuration rather than network-based monitoring.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960773370139,"sku":"6EP4136-3AB00-1AY0","price":337.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4136-3ab00-1ay0-sitop-ups1600-dc-ups-module.png?v=1789780449"},{"product_id":"siemens-6ep4136-3ab00-2ay0-sitop-ups1600-24v-20a-profinet","title":"Siemens 6EP4136-3AB00-2AY0 SITOP UPS1600 24V\/20A PROFINET DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP4136-3AB00-2AY0 is a SITOP UPS1600 DC uninterruptible power supply module rated 24 V DC at 20 A with an Ethernet\/PROFINET interface, an OPC UA server, and a built-in web server. It buffers a 21-29 V DC input and delivers 97.5% efficiency in normal and battery-buffered operation, with buffering time adjustable from 0.5 to 20 minutes.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6EP4136-3AB00-2AY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e21 - 29 V DC, rated 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (normal and buffering mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e20 A rated, 0 - 60 A normal\/buffering range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Current\u003c\/td\u003e\n\u003ctd\u003e60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e97.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e11 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied Power\u003c\/td\u003e\n\u003ctd\u003e480 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffering Time Setting\u003c\/td\u003e\n\u003ctd\u003e0.5 - 20 min adjustable via rotary switch or software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eEthernet\/PROFINET, 2 ports, OPC UA server, web server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eShort-circuit proof, reverse polarity protected on input and battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF at 40 degrees C\u003c\/td\u003e\n\u003ctd\u003e345056 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation)\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e50 x 139 x 125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x7.5\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eSame 20 A rating and 60 A peak current as the USB variant, but the two PROFINET ports plus OPC UA and web server let this module report battery status and buffering state to a PLC or SCADA system instead of requiring a local USB connection. That networking adds 0.04 kg and 1 W of power loss over the USB model, a reasonable trade for remote diagnostics on unmanned cabinets. Choose it over the 10 A or 40 A modules based on the connected load's current draw, not the interface.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960773599515,"sku":"6EP4136-3AB00-2AY0","price":414.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4136-3ab00-2ay0-sitop-ups1600-dc-ups-module.png?v=1789780455"},{"product_id":"siemens-6ep4137-0ge00-0ay0-sitop-bat1600-24v-38ah-battery","title":"Siemens 6EP4137-0GE00-0AY0 SITOP BAT1600 24V\/38Ah Lead-Acid Battery Module","description":"\u003cp\u003eThe Siemens 6EP4137-0GE00-0AY0 is a SITOP BAT1600 battery module with a maintenance-free, closed lead-acid cell rated 24 V DC at 38 Ah, sized for the SITOP UPS1600 platform. It supplies a rated output current of 40 A and a peak current of 120 A for 30 ms, and weighs 27.9 kg for floor mounting.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6EP4137-0GE00-0AY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSITOP BAT1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003e38 Ah Pb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free lead-acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Capacity\u003c\/td\u003e\n\u003ctd\u003e38 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e40 A rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Current\u003c\/td\u003e\n\u003ctd\u003e120 A for 30 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Charging Current\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Cells\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003e50 A\/32 V Maxi flat fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation)\u003c\/td\u003e\n\u003ctd\u003e-15 to +50 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 20 degrees C\u003c\/td\u003e\n\u003ctd\u003e10 years typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003ePlug-in terminals with screwed connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e394 x 212 x 165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFloor mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e27.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 38 Ah this is the largest battery in the BAT1600 line, more than five times the 7.5 Ah lithium module's capacity, and floor mounting rather than DIN rail or wall mounting reflects its 27.9 kg weight. The 40 A rated output matches the highest-current SITOP UPS1600 units, and the 9 A max charging current is the highest in the BAT1600 range, letting the battery recharge faster after a deep buffering event. Service life falls off faster with heat than the lithium variants: 10 years at 20 degrees C but only 1.25 years at 50 degrees C.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960773632283,"sku":"6EP4137-0GE00-0AY0","price":668.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4137-0ge00-0ay0-sitop-bat1600-battery-module.png?v=1789780461"},{"product_id":"siemens-6ep4137-3ab00-0ay0-sitop-ups1600-dc-ups-module","title":"Siemens 6EP4137-3AB00-0AY0 SITOP UPS1600 24V\/40A DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP4137-3AB00-0AY0 is a SITOP UPS1600 DC uninterruptible power supply module rated for a 24 V DC \/ 40 A output (120 A peak), buffering the load from an external battery when the 24 V input drops below the adjustable cut-in threshold (21-25 V). Buffering time is set from 0.5 to 20 minutes via a rotary switch, at a typical 98.5% efficiency and 15 W power loss.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6EP4137-3AB00-0AY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType of current supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC UPS 24 V \/ 40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21 ... 29 V, rated 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffer connection cut-in threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable 21 ... 25 V (21, 21.5, 22, 22.5, 23, 24, 25 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput current at rated 24 V\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e46 A (incl. 5 A max. charging current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput voltage, normal\/buffering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (18.5 ... 27 V in buffering mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A rated, 0 ... 120 A operating range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeak current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffering time, adjustable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5, 1, 2, 5, 10, 20 min (rotary switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, limited to 3x rated for 30 ms\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class \/ IP rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass III \/ IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTBF at 40 degrees C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e372,738 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient temperature, operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 ... +70 degrees C, natural convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure dimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 x 139 x 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.65 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUL 508\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eABS Marine\u003c\/li\u003e\n\u003cli\u003eDNV Marine\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 40 A rated \/ 120 A peak output sizes this UPS1600 for a 24 V DC bus feeding several PLCs, drives, or I\/O racks through a mains dip, not just a single small controller - check total connected load against the 40 A continuous rating before specifying a smaller SITOP UPS in the same family. The rotary-switch buffering time (0.5-20 min) lets the same module cover both a short ride-through for controlled shutdown and a longer bridge while a generator starts, without reprogramming. Marine classification (ABS, DNV) makes it a fit for shipboard 24 V DC control panels where that approval is a spec requirement.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eBridges short mains interruptions on 24 V DC control and automation buses: PLC racks, drive control electronics, and instrumentation that must ride through brief supply dips or complete a controlled shutdown before battery reserve runs out.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960773665051,"sku":"6EP4137-3AB00-0AY0","price":452.7,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4137-3ab00-0ay0-sitop-ups1600-dc-ups-module.png?v=1789678938"},{"product_id":"siemens-6ep4137-3ab00-1ay0-sitop-ups1600-24v-40a-usb","title":"Siemens 6EP4137-3AB00-1AY0 SITOP UPS1600 24V\/40A USB DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP4137-3AB00-1AY0 is a SITOP UPS1600 DC uninterruptible power supply module rated 24 V DC at 40 A with a USB interface. It buffers a 21-29 V DC input against short-circuits and delivers 98.5% efficiency in both normal and battery-buffered operation, with buffering time adjustable from 0.5 to 20 minutes via rotary switch.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6EP4137-3AB00-1AY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e21 - 29 V DC, rated 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (normal and buffering mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e40 A rated, 0 - 120 A normal\/buffering range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Current\u003c\/td\u003e\n\u003ctd\u003e120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e98.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e15 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied Power\u003c\/td\u003e\n\u003ctd\u003e960 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffering Time Setting\u003c\/td\u003e\n\u003ctd\u003e0.5 - 20 min adjustable via rotary switch or software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eShort-circuit proof, reverse polarity protected on input and battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF at 40 degrees C\u003c\/td\u003e\n\u003ctd\u003e330515 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature (Operation)\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e70 x 139 x 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x7.5\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.65 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 40 A rating is the top of the SITOP UPS1600 current range, four times the entry module's output in a housing only 20 mm wider. Efficiency climbs to 98.5% at this rating, the highest of the three current variants, which matters on continuously loaded 24 V buses where every watt of loss becomes cabinet heat. It needs the higher-capacity BAT1600 battery modules to reach its full 120 A peak buffering current, not the smaller lithium or lead-acid packs sized for the 10 A or 20 A units.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960773697819,"sku":"6EP4137-3AB00-1AY0","price":510.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4137-3ab00-1ay0-sitop-ups1600-dc-ups-module.png?v=1789780468"},{"product_id":"siemens-6ep4137-3ab00-2ay0-sitop-ups1600","title":"Siemens 6EP4137-3AB00-2AY0 SITOP UPS1600 24V\/40A Ethernet\/PROFINET Power Supply","description":"\u003cp\u003eThe Siemens 6EP4137-3AB00-2AY0 is a SITOP UPS1600 DC uninterruptible power supply module that buffers a 24 V DC bus at up to 40 A rated output current using an internal battery. It adds Ethernet\/PROFINET, an OPC UA server and a web server for remote monitoring, and accepts 21 ... 29 V DC at the input so it rides through moderate supply sag before switching to battery.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6EP4137-3AB00-2AY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS1600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4025515154266\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Current Supply\u003c\/td\u003e\n\u003ctd\u003eDC UPS 24 V\/40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e21 ... 29 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current at Rated Voltage\u003c\/td\u003e\n\u003ctd\u003e46 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffer Connection Response Voltage\u003c\/td\u003e\n\u003ctd\u003e21 ... 25 V, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage, Normal Operation\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage, Buffering Mode\u003c\/td\u003e\n\u003ctd\u003e18.5 ... 27 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current, Rated\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Range\u003c\/td\u003e\n\u003ctd\u003e0 ... 120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Current\u003c\/td\u003e\n\u003ctd\u003e120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Short-Circuit Proof\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Storage\u003c\/td\u003e\n\u003ctd\u003eInternal battery, modularly expandable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffering Time, Adjustable\u003c\/td\u003e\n\u003ctd\u003e0.5, 1, 2, 5, 10, 20 min or via software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency, Rated Output\u003c\/td\u003e\n\u003ctd\u003e98.3 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e17 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied Active Power\u003c\/td\u003e\n\u003ctd\u003e960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStartup Delay Time\u003c\/td\u003e\n\u003ctd\u003e60 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eEthernet\/PROFINET, 2 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF at 40 C\u003c\/td\u003e\n\u003ctd\u003e318776 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/cULus Approval\u003c\/td\u003e\n\u003ctd\u003ecULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Resource Protection Class\u003c\/td\u003e\n\u003ctd\u003eClass III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-25 ... +70 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure W x H x D\u003c\/td\u003e\n\u003ctd\u003e70 x 139 x 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x7.5\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eShipbuilding\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 21 ... 29 V input range and adjustable 21 ... 25 V buffer-connection threshold let this module be tuned to the actual sag characteristics of the 24 V bus it protects, instead of triggering on every minor dip. Buffering time is set from 0.5 to 20 minutes by rotary switch or software, so the module can be configured for a brief ride-through on a UPS-backed line or a longer bridge on an unprotected feed. Because the battery, charger and PROFINET interface are integrated in one DIN-rail unit, it fits panels that need 24 V bus protection with remote status reporting but do not already run a SITOP PSU8600 rack.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960773730587,"sku":"6EP4137-3AB00-2AY0","price":588.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4137-3ab00-2ay0-sitop-ups1600-power-supply.png?v=1789780475"},{"product_id":"siemens-6ep4143-8jb00-0xy0-sitop-bat8600-lifepo4","title":"Siemens 6EP4143-8JB00-0XY0 SITOP BAT8600 LiFePO4 48V\/358Wh Battery DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP4143-8JB00-0XY0 is a SITOP BAT8600 LiFePO4 battery module that stores 358 W-h at 48 V DC for the SITOP UPS8600 uninterruptible power system, delivering 20 A rated output current. Its maintenance-free lithium iron phosphate cells bridge roughly 21 minutes at a 960 W system load, and up to five modules can be paralleled to extend backup time.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6EP4143-8JB00-0XY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSITOP BAT8600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4025515155096\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eBattery module 358 Wh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free LiFePO4 rechargeable battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Content\u003c\/td\u003e\n\u003ctd\u003e358 W-h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current, Rated\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBridging Time at 960 W Load\u003c\/td\u003e\n\u003ctd\u003etyp. 21 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBridging Time at 480 W Load\u003c\/td\u003e\n\u003ctd\u003etyp. 42 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Parallel Modules\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eBlade-type fuse 40 A, 58 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eValve control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e3-color LED for module operating state\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Resource Protection Class\u003c\/td\u003e\n\u003ctd\u003eClass III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/cULus Approval\u003c\/td\u003e\n\u003ctd\u003ecULus (UL 61010-1 3rd Ed., UL 61010-2-201 2nd Ed.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-10 ... +50 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 10 C\u003c\/td\u003e\n\u003ctd\u003etyp. 15 a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 20 C\u003c\/td\u003e\n\u003ctd\u003etyp. 13 a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 30 C\u003c\/td\u003e\n\u003ctd\u003etyp. 8 a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 40 C\u003c\/td\u003e\n\u003ctd\u003etyp. 4 a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 50 C\u003c\/td\u003e\n\u003ctd\u003etyp. 2 a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Batteries\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure W x H x D\u003c\/td\u003e\n\u003ctd\u003e322 x 187 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall mounting, keyhole for M4 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e7.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eShipbuilding\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eService life falls sharply with ambient temperature: 15 years at 10 C drops to 2 years at 50 C, so cabinet ventilation and mounting location drive the replacement interval more than the headline capacity rating does. At a 960 W system load the module bridges about 21 minutes; halving the load to 480 W nearly doubles that to 42 minutes, which matters when sizing a controlled-shutdown window against the actual downstream draw. Up to five BAT8600 modules can be paralleled on the same UPS8600 bus to extend runtime without changing the charger or communication wiring.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960773763355,"sku":"6EP4143-8JB00-0XY0","price":1592.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4143-8jb00-0xy0-sitop-bat8600-lifepo4-dc-ups-module.png?v=1789780482"},{"product_id":"siemens-6ep4145-8gb00-0xy0-sitop-bat8600-pb","title":"Siemens 6EP4145-8GB00-0XY0 SITOP BAT8600 Lead-Acid 48V\/380Wh Battery DC UPS Module","description":"\u003cp\u003eThe Siemens 6EP4145-8GB00-0XY0 is a SITOP BAT8600 lead-acid battery module that stores 380 W-h at 48 V DC for the SITOP UPS8600 uninterruptible power system, delivering 20 A rated output current. Its maintenance-free sealed lead-acid cells bridge about 10 minutes at a 960 W system load, and up to five modules can be paralleled to extend backup time.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6EP4145-8GB00-0XY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSITOP BAT8600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4025515155089\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eBattery module 380 Wh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eMaintenance-free lead-acid batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Content\u003c\/td\u003e\n\u003ctd\u003e380 W-h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current, Rated\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBridging Time at 960 W Load\u003c\/td\u003e\n\u003ctd\u003etyp. 10 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBridging Time at 480 W Load\u003c\/td\u003e\n\u003ctd\u003etyp. 25 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Parallel Modules\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eBlade-type fuse 40 A, 58 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eValve control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e3-color LED for module operating state\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Resource Protection Class\u003c\/td\u003e\n\u003ctd\u003eClass III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/cULus Approval\u003c\/td\u003e\n\u003ctd\u003ecULus (UL 61010-1 3rd Ed., UL 61010-2-201 2nd Ed.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-10 ... +50 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 10 C\u003c\/td\u003e\n\u003ctd\u003etyp. 8 a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 20 C\u003c\/td\u003e\n\u003ctd\u003etyp. 4 a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 30 C\u003c\/td\u003e\n\u003ctd\u003etyp. 2 a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 40 C\u003c\/td\u003e\n\u003ctd\u003etyp. 1 a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Life at 50 C\u003c\/td\u003e\n\u003ctd\u003etyp. 0.5 a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Batteries\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure W x H x D\u003c\/td\u003e\n\u003ctd\u003e322 x 187 x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eWall mounting, keyhole for M4 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e13.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eShipbuilding\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eService life on this chemistry drops off faster with heat than a typical DIN-rail accessory: 8 years at 10 C falls to just 6 months at 50 C, so placement away from heat-generating equipment is the main lever for reaching the rated life. At a 960 W system load the module bridges about 10 minutes; at 480 W that stretches to 25 minutes, a useful reference when matching bridging time to the actual downstream load rather than the full 40 A system rating. Up to five BAT8600 modules can be paralleled on the same UPS8600 bus to extend runtime without adding a separate charger.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960773796123,"sku":"6EP4145-8GB00-0XY0","price":423.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4145-8gb00-0xy0-sitop-bat8600-pb-dc-ups-module.png?v=1789780489"},{"product_id":"siemens-6ep4197-8ab00-0xy0-sitop-ups8600","title":"Siemens 6EP4197-8AB00-0XY0 SITOP UPS8600 48V\/960W PSU8600 UPS Power Supply Module","description":"\u003cp\u003eThe Siemens 6EP4197-8AB00-0XY0 is a SITOP UPS8600 UPS module that plugs into a SITOP PSU8600 power supply and buffers its 48 V DC output at up to 960 W using external BAT8600 battery modules. Its charger delivers up to 120 W to recharge the batteries, and buffer time is set from 1 to 88 minutes by DIP switch or until the batteries are discharged.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6EP4197-8AB00-0XY0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSITOP UPS8600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4025515155102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Current Supply\u003c\/td\u003e\n\u003ctd\u003e960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Storage\u003c\/td\u003e\n\u003ctd\u003eExternal battery module (BAT8600)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffer Time, Adjustable\u003c\/td\u003e\n\u003ctd\u003e1 ... 88 min via DIP switches, or until batteries discharged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage, Normal Operation\u003c\/td\u003e\n\u003ctd\u003e48 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Short-Circuit Proof\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Current\u003c\/td\u003e\n\u003ctd\u003e1.25 A, 2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eRelay contacts (NO, DC 60 V\/0.3 A) for buffer readiness, buffer mode, battery circuit fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency on Battery Operation\u003c\/td\u003e\n\u003ctd\u003etyp. 99 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss on Battery Operation\u003c\/td\u003e\n\u003ctd\u003etyp. 10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied Active Power\u003c\/td\u003e\n\u003ctd\u003etyp. 960 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eEthernet\/PROFINET via PSU8600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMTBF at 40 C\u003c\/td\u003e\n\u003ctd\u003e405763 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/cULus Approval\u003c\/td\u003e\n\u003ctd\u003ecULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Resource Protection Class\u003c\/td\u003e\n\u003ctd\u003eClass III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-25 ... +70 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Expansion Modules\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure W x H x D\u003c\/td\u003e\n\u003ctd\u003e60 x 125 x 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail EN 60715 35x15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eShipbuilding\u003c\/li\u003e\n\u003cli\u003eABS\u003c\/li\u003e\n\u003cli\u003eDNV\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBuffer time is set from 1 to 88 minutes by DIP switch, or the module can be left to run until the attached BAT8600 batteries are fully discharged, so the same hardware covers both a short controlled-shutdown bridge and an extended runtime application depending only on switch position and battery count. It draws power through the PSU8600's integrated connector rather than separate input terminals, and supports up to two expansion modules for additional output capacity, so it fits installations already built around the PSU8600 rack rather than a standalone 24 V bus.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960773828891,"sku":"6EP4197-8AB00-0XY0","price":414.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6ep4197-8ab00-0xy0-sitop-ups8600-power-supply.png?v=1789780495"}],"url":"https:\/\/stoklink.com\/collections\/dc-ups.oembed?page=2","provider":"Stoklink","version":"1.0","type":"link"}