{"title":"Connectors, Plugs \u0026 Power Distribution","description":"\u003cp\u003eConnectors, plugs and power distribution components from Schneider Electric, Harting, Mersen and ABB, covering industrial plugs and sockets, heavy duty connectors, busbars, distribution blocks and fuse adapters. Rated currents run from 1 A signal contacts up to 400 A industrial sockets. Stoklink ships worldwide from Turkey and quotes project volumes on request.\u003c\/p\u003e\n\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/industrial-plugs-sockets\"\u003eIndustrial Plugs \u0026amp; Sockets\u003c\/a\u003e – Schneider Electric Mureva PK, PratiKa and Unika plugs and sockets for panel, wall and portable use.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/heavy-duty-connectors\"\u003eHeavy Duty Connectors\u003c\/a\u003e – Harting Han B, Han D, Han Q, Han A, Han-Modular housings, frames and crimp contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/busbars-distribution-blocks\"\u003eBusbars, Distribution Blocks \u0026amp; Enclosures\u003c\/a\u003e – ABB PS1 busbars and infeed blocks, Schneider Electric Linergy FT, Mersen MULTIFIX 60 mm adapters and fuse bases.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHow to choose\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRated current and voltage: match the plug or socket to the circuit, for example 16 A or 32 A at 200-250 V or 380-415 V.\u003c\/li\u003e\n\u003cli\u003ePole configuration: 2P+E, 3P+E or 3P+N+E for industrial sockets, and the number of contacts for heavy duty inserts.\u003c\/li\u003e\n\u003cli\u003eIngress protection: IP44 for splash-resistant indoor use, IP67 where water immersion is possible.\u003c\/li\u003e\n\u003cli\u003eMounting and wiring: panel, wall or portable, and the conductor cross-section the terminals accept.\u003c\/li\u003e\n\u003cli\u003eStandards: check the product datasheet for the IEC standard that applies to the device, such as IEC 60309 for industrial plugs and sockets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eCan I mix brands of plugs and sockets?\u003c\/h3\u003e\n\u003cp\u003ePlugs and sockets built to the same IEC standard share the same pole layout, voltage and current coding. Confirm the rating and key position on both sides before ordering.\u003c\/p\u003e\n\u003ch3\u003eWhat is the difference between an industrial socket and a heavy duty connector?\u003c\/h3\u003e\n\u003cp\u003eIndustrial plugs and sockets supply power to portable equipment on a standard coding. Heavy duty connectors such as Harting Han link machines and panels with modular power, signal and data contacts in one housing.\u003c\/p\u003e\n\u003ch3\u003eDo you ship these components outside Turkey?\u003c\/h3\u003e\n\u003cp\u003eYes. Stoklink ships worldwide from Turkey under EXW terms. Lead time depends on distributor stock, and bulk orders are quoted on request.\u003c\/p\u003e","products":[{"product_id":"abb-2cdl200001r0001-ps-end-phase-busbar-end-cap","title":"ABB 2CDL200001R0001 PS-END End Cap Phase Busbar Accessory 18mm CE RoHS","description":"\u003cp\u003eThe ABB PS-END (2CDL200001R0001) is a genuine ABB end cap designed to terminate and protect phase busbars in industrial control panel assemblies. The PS-END provides a secure, insulating closure at the end of busbar runs, preventing accidental contact and ensuring compliance with electrical safety standards. Compact at 18 mm × 17 mm × 8 mm and weighing just 1 g, it integrates seamlessly into ABB busbar systems.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePS-END\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDL200001R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779514729\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Busbar End Cap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to applicable European Union directives for electrical equipment safety and electromagnetic compatibility.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances directive — free from restricted hazardous materials.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Meets EU REACH regulation requirements regarding chemical substance safety in electrical components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment directive for responsible end-of-life disposal and recycling.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eTerminating exposed ends of ABB PS-series phase busbars in control panels and distribution boards\u003c\/li\u003e\n\u003cli\u003eProviding IP-rated insulation protection at busbar ends to prevent accidental live contact\u003c\/li\u003e\n\u003cli\u003eIndustrial automation and motor control centre (MCC) panel builds requiring tidy, compliant busbar installations\u003c\/li\u003e\n\u003cli\u003eOEM panel builders and system integrators working with ABB busbar distribution systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229021180187,"sku":"2CDL200001R0001","price":3.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cdl200001r0001-ps-end-18mm-ce-rohs_6456cdfc-a6e1-470b-89d8-bd654d487112.webp?v=1777160941"},{"product_id":"abb-1saz701901r0001-db16-single-mounting-kit","title":"ABB 1SAZ701901R0001 DB16 Single Mounting Kit 3P 16A 690V AC DIN Rail or Plate","description":"\u003cp\u003eThe ABB DB16 Single Mounting Kit (SKU: 1SAZ701901R0001) is a purpose-built mounting accessory designed for secure installation of DB16 series components on DIN rail or mounting plate configurations. Rated at 16 A and 690 V AC with a 3-pole configuration, the DB16 mounting kit ensures reliable mechanical fixing in control panels and industrial automation enclosures. Compact at 92 x 50 x 73 mm and weighing just 0.032 kg, it integrates effortlessly into existing panel layouts.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDB16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAZ701901R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDB16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Mounting Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail or mounting plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e92 x 50 x 73 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.032 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614407819\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European CE marking requirements for electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS II:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive (recast)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEU Declaration of Conformity:\u003c\/strong\u003e Full EU DoC issued by ABB for this product\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA 22.2 No.14:\u003c\/strong\u003e Certified to Canadian Standards Association industrial control equipment standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Complies with general rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Complies with contactors and motor starters standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing standard compliance for industrial components\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard for low-voltage switchgear (general rules)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e European harmonised standard for contactors and motor starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Listed to UL standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229121057051,"sku":"1SAZ701901R0001","price":10.67,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1saz701901r0001-db16-rail-or-plate_3ea61024-d4fb-4d42-970f-c2b073154950.webp?v=1777156408"},{"product_id":"abb-1saz701902r0001-db42-single-mounting-kit","title":"ABB 1SAZ701902R0001 DB42 Single Mounting Kit 3P 40A 690V AC DIN Rail","description":"\u003cp\u003eThe ABB DB42 Single Mounting Kit (SKU: 1SAZ701902R0001) is a purpose-built mounting accessory designed to securely install compatible ABB motor starters and switching devices on standard DIN rail or mounting plates. Supporting 3-pole configurations rated at 40 A and 690 V AC, the DB42 delivers reliable mechanical integration for industrial control panel assemblies, ensuring safe and compliant installations across automation and motor protection applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDB42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAZ701902R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDB42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle Mounting Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN rail or mounting plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 x 102 x 108 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.087 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614407826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with European Union directives for electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed mark for the Great Britain market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Listed per UL standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA 22.2 No. 14:\u003c\/strong\u003e Meets CSA standard for industrial control equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Low-voltage switchgear and controlgear — contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard for low-voltage switchgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e European harmonised standard for contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60068-2:\u003c\/strong\u003e Environmental testing for electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH chemical regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSecure single-unit mounting of ABB motor starters and switching devices in control panels\u003c\/li\u003e\n\u003cli\u003eDIN rail installation in industrial automation and motor protection enclosures\u003c\/li\u003e  \u003cli\u003eMounting plate installation for fixed industrial control assemblies\u003c\/li\u003e\n\u003cli\u003eIntegration within motor control centres (MCCs) and distribution boards\u003c\/li\u003e\n\u003cli\u003eUse alongside ABB contactors, thermal overload relays, and manual motor starters rated up to 40 A \/ 690 V AC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229158576411,"sku":"1SAZ701902R0001","price":12.45,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1saz701902r0001-db42-ac-din-rail_cfd1eb1c-e54b-4ae0-812a-ad78ff8b0970.webp?v=1777156413"},{"product_id":"abb-1sam201906r1102-ps1-2-0-65-phase-busbar","title":"ABB 1SAM201906R1102 PS1-2-0-65 3-Phase Busbar 2-Way 65A 690V AC for MS116\/MS132 Manual Motor Starters","description":"\u003cp\u003eThe ABB PS1-2-0-65 (SKU: 1SAM201906R1102) is a 3-phase busbar designed to connect two MS116 or MS132 manual motor starters side by side, rated at 65A and 690V AC \/ 250V DC. This compact busbar simplifies wiring in control panels by providing a reliable, low-resistance electrical connection between adjacent motor protection devices without additional cabling. With dimensions of just 86.5 × 32.3 × 13 mm and a weight of 34 g, the PS1-2-0-65 is engineered for space-efficient DIN rail assemblies in industrial automation and motor protection applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePS1-2-0-65\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAM201906R1102\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePS1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMS116, MS132 (2 units)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e86.5 × 32.3 × 13 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.034 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614400681\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard for low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947:\u003c\/strong\u003e Combined IEC and EN compliance for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947:\u003c\/strong\u003e European standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e European standard for electromechanical contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for North American markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation compliance — restriction of hazardous chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity marking — meets EU health, safety, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking — meets Great Britain market requirements post-Brexit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eConnecting two ABB MS116 or MS132 manual motor starters in a common busbar assembly\u003c\/li\u003e\n  \u003cli\u003eMotor protection panels in manufacturing, process automation, and HVAC control systems\u003c\/li\u003e\n  \u003cli\u003eSpace-optimised DIN rail switchboard assemblies where multiple motor starters are mounted side by side\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels requiring simplified, cable-free power distribution between adjacent devices\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229166145819,"sku":"1SAM201906R1102","price":7.54,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sam201906r1102-ps1-2-0-65-65a-phase-busbar_9be1e4de-ceb8-4487-af63-8d91d25f6753.webp?v=1777156027"},{"product_id":"abb-1sam201906r1104-ps1-4-0-65-phase-busbar","title":"ABB 1SAM201906R1104 PS1-4-0-65 3-Phase Busbar 65A for 4x MS116\/MS132 Manual Motor Starters","description":"\u003cp\u003eThe ABB PS1-4-0-65 (SKU: 1SAM201906R1104) is a 3-phase busbar rated at 65A, designed to connect up to four MS116 or MS132 manual motor starters in a compact, parallel-feed arrangement. Part of ABB's PS1 busbar series, this component simplifies wiring in control panels by eliminating individual phase cables between motor starter groups, reducing assembly time and improving installation reliability. Its compact dimensions of 176.5 mm × 32.3 mm × 13 mm and lightweight construction at just 77 g make it well-suited for space-constrained enclosures.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePS1-4-0-65\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAM201906R1104\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePS1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Phases\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMS116, MS132 (up to 4 units)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L × W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e176.5 mm × 32.3 mm × 13 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.077 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614400704\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard equivalent to IEC 60947-1 for low-voltage switchgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947:\u003c\/strong\u003e Combined IEC and EN compliance covering low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947:\u003c\/strong\u003e European standard series for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e European standard for contactors and motor starters within the low-voltage switchgear series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for electrical equipment safety\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation compliance for restriction of hazardous chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marking indicating compliance with applicable EU directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for products placed on the Great Britain market\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eGrouping up to four MS116 or MS132 manual motor starters on a common 3-phase busbar in motor control centres\u003c\/li\u003e\n  \u003cli\u003eSimplifying multi-motor wiring in industrial control panels, machine tools, and conveyor systems\u003c\/li\u003e\n  \u003cli\u003eReducing panel wiring complexity and connection errors in factory automation and process control installations\u003c\/li\u003e\n  \u003cli\u003eSpace-saving distribution of 3-phase power across grouped motor starters in compact enclosures\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229166473499,"sku":"1SAM201906R1104","price":9.41,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sam201906r1104-ps1-4-0-65-65a-phase-busbar_f6a0bf09-ce1f-407e-8500-329dd8624dcd.webp?v=1777156037"},{"product_id":"abb-1sam201906r1103-ps1-3-0-65-3-phase-busbar-65a","title":"ABB 1SAM201906R1103 PS1-3-0-65 3-Phase Busbar 65A for MS116\/MS132 Manual Motor Starters","description":"\u003cp\u003eThe ABB PS1-3-0-65 (SKU: 1SAM201906R1103) is a 3-phase busbar designed to interconnect up to three MS116 or MS132 manual motor starters in a compact, rail-mounted assembly. Rated at 65 A and built to IEC\/EN 60947 standards, this phase busbar eliminates point-to-point wiring between adjacent motor protection devices, reducing panel build time and improving installation reliability. With dimensions of 131.5 mm × 32.3 mm × 13 mm and a weight of just 55 g, the PS1-3-0-65 is optimised for space-constrained control panels and motor control centres.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePS1-3-0-65\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAM201906R1103\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePS1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-Phase Busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Phases\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMS116, MS132 Manual Motor Starters (up to 3 units)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L × W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e131.5 mm × 32.3 mm × 13 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.055 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614400698\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947:\u003c\/strong\u003e Comprehensive IEC\/EN switchgear and controlgear compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947:\u003c\/strong\u003e EN suite compliance for low-voltage switchgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e Low-voltage switchgear — contactors and motor starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for North American market compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive — halogen and heavy-metal compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne marking — meets all applicable EU directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking — valid for Great Britain market\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eGrouping multiple MS116 or MS132 manual motor starters on a common DIN rail with shared busbar power distribution\u003c\/li\u003e\n  \u003cli\u003eMotor control centres (MCC) and distribution boards requiring compact, pre-wired phase connections\u003c\/li\u003e\n  \u003cli\u003eMachine building and OEM panel assemblies where wiring reduction and consistent torque connections are critical\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation systems with multiple small motor loads requiring coordinated protection\u003c\/li\u003e\n  \u003cli\u003eHVAC, pump, and conveyor control panels where three adjacent starters share a supply\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229166539035,"sku":"1SAM201906R1103","price":8.57,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sam201906r1103-ps1-3-0-65-65a-phase-busbar_3fd79c3c-4b06-4712-b60e-64711d56bd67.webp?v=1777156032"},{"product_id":"abb-1sam201906r1105-ps1-5-0-65-3phase-busbar-65a","title":"ABB 1SAM201906R1105 PS1-5-0-65 3-Phase Busbar 65A for 5 MS116\/MS132 Manual Motor Starters","description":"\u003cp\u003eThe ABB PS1-5-0-65 (SKU 1SAM201906R1105) is a 3-phase busbar designed to interconnect up to five MS116 or MS132 manual motor starters in a compact, rail-mounted assembly. Rated at 65 A, the PS1-5-0-65 eliminates individual wiring between adjacent starters, reducing panel build time and improving circuit reliability. Weighing just 98 g and measuring 221.5 mm × 32.3 mm × 13 mm, it integrates neatly into control panel layouts without consuming additional space.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePS1-5-0-65\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAM201906R1105\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePS1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase Busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Phases\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMS116, MS132 (up to 5 units)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L × W × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e221.5 mm × 32.3 mm × 13 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.098 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614400711\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard equivalent to IEC 60947-1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947:\u003c\/strong\u003e Combined IEC and EN compliance for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947:\u003c\/strong\u003e European standard series for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e Standard for contactors and motor-starters within the EN 60947 family\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for the North American market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation compliance confirming no restricted substances in the product\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance for responsible disposal\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marking confirming EU regulatory requirements are met\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for post-Brexit Great Britain market\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eGrouping multiple MS116 or MS132 manual motor starters on a single DIN rail for multi-motor control panels\u003c\/li\u003e\n  \u003cli\u003eSimplifying 3-phase power distribution across adjacent motor protection devices in industrial automation systems\u003c\/li\u003e\n  \u003cli\u003eReducing control panel wiring density and assembly time in OEM machine building\u003c\/li\u003e\n  \u003cli\u003eMotor feeder groups in pump stations, conveyor systems, and HVAC equipment rooms\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229166604571,"sku":"1SAM201906R1105","price":10.85,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sam201906r1105-ps1-5-0-65-65a-phase-busbar_8735d37b-c248-449f-9abc-6661ba4b43f4.webp?v=1777156042"},{"product_id":"abb-1sam201907r1101-s1-m1-25-3phase-power-infeed-block","title":"ABB 1SAM201907R1101 S1-M1-25 3-Phase Power Infeed Block Flat 65A 25mm² for MS116\/MS132","description":"\u003cp\u003eThe ABB S1-M1-25 (SKU: 1SAM201907R1101) is a 3-phase power infeed block designed for flat mounting and rated at 65 A with 25 mm² conductor capacity. Compatible with ABB MS116 and MS132 manual motor starters, the S1-M1-25 provides a reliable, space-efficient solution for supplying three-phase power to motor protection circuits in industrial control panels. Its compact dimensions of 44 mm × 38 mm × 25.5 mm and lightweight 0.038 kg construction make it easy to integrate into dense panel layouts.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS1-M1-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAM201907R1101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614400803\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-Phase Power Infeed Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Cross-Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMS116, MS132\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44 mm × 38 mm × 25.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.038 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-1:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard for low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947:\u003c\/strong\u003e Combined IEC and EN compliance for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947:\u003c\/strong\u003e European standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e European standard for contactors and motor-starters\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certification for North American market compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliance — lead-free and environmentally safe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance for responsible end-of-life disposal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne marking confirming compliance with EU health, safety, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market access post-Brexit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eThree-phase power distribution to MS116 and MS132 manual motor starters in industrial control panels\u003c\/li\u003e\n\u003cli\u003eMotor protection assemblies in manufacturing, process automation, and building services\u003c\/li\u003e\n\u003cli\u003eSpace-constrained panel builds requiring flat-mount infeed accessories\u003c\/li\u003e\n\u003cli\u003eOEM machine builder assemblies requiring standardised ABB motor starter accessories\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229166801179,"sku":"1SAM201907R1101","price":6.84,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sam201907r1101-s1-m1-25-line-branch-terminal_b1fb2817-4205-463d-9b8a-2f0ad7e2bb64.webp?v=1777156046"},{"product_id":"abb-1sam201911r1010-ib132-g-ip65-empty-enclosure","title":"ABB 1SAM201911R1010 IB132-G IP65 118×194×119mm 3x Lockable Empty Enclosure for Switchgear","description":"\u003cp\u003eThe ABB IB132-G (SKU 1SAM201911R1010) is an IP65-rated empty enclosure for switchgear, designed to house manual motor starters and associated components in demanding industrial environments. Finished in grey\/black (GY\/BK), this standard-version enclosure measures 118 mm (W) × 194 mm (H) × 119 mm (D), weighs just 0.37 kg, and supports up to three-point locking for enhanced security and tamper resistance.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIB132-G\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAM201911R1010\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIB132\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614421617\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmpty Enclosure for Switchgear\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrey \/ Black (GY\/BK)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLockable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 times lockable (standard version)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e118 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e194 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e119 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.37 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Contactors and motor-starters — low-voltage switchgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European harmonised standard — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e European harmonised standard — contactors and motor-starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e Industrial Control Equipment (UL Listed)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA 22.2 No.14:\u003c\/strong\u003e Industrial Control Equipment (Canadian Standards Association)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e CSA certified for Canadian and North American markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed — approved for Great Britain market\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive — compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eHousing ABB MS132 manual motor starters and associated switchgear in control panel installations\u003c\/li\u003e\n  \u003cli\u003eMachine and equipment builder enclosures requiring IP65 ingress protection against dust and water jets\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation panels in food processing, chemical, and outdoor environments\u003c\/li\u003e\n  \u003cli\u003eSecure switchgear installations requiring three-point locking for restricted access\u003c\/li\u003e\n  \u003cli\u003eMotor protection and control assemblies in manufacturing and process industries\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229167292699,"sku":"1SAM201911R1010","price":17.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sam201911r1010-ib132-g-3x-lockable-118x194x119mm_1cf3f288-312b-41b3-b11a-083f3aca7209.webp?v=1777156051"},{"product_id":"abb-1sam201911r1011-ib132-y-ip65-empty-enclosure","title":"ABB 1SAM201911R1011 IB132-Y IP65 Red\/Yellow Emergency-Stop Empty Enclosure for Switchgear 118×194×119mm","description":"\u003cp\u003eThe ABB IB132-Y (SKU 1SAM201911R1011) is an IP65-rated empty enclosure for switchgear designed to house emergency-stop devices and control components in demanding industrial environments. Featuring a distinctive red\/yellow color scheme for immediate visual identification, the IB132-Y is 3-times lockable, ensuring safety and compliance in control panel and automation applications. With compact dimensions of 118 mm (W) × 194 mm (H) × 119 mm (D) and a lightweight 0.37 kg, it is engineered for straightforward installation and robust protection.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIB132-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SAM201911R1011\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIB132\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4013614421624\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmpty Enclosure for Switchgear\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed \/ Yellow (RD\/YE)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmergency-STOP\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLockable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 times lockable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e118 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e194 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e119 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.37 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA 22.2 No.14:\u003c\/strong\u003e Canadian Standards Association — industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-4:\u003c\/strong\u003e Low-voltage switchgear and controlgear — contactors and motor-starters\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-1:\u003c\/strong\u003e European adoption of IEC 60947-1 general rules standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60947-4:\u003c\/strong\u003e European adoption of IEC 60947-4 contactors and motor-starters standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 508:\u003c\/strong\u003e UL standard for industrial control equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association product certification\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical safety regulation compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marking\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e UK Conformity Assessed marking for Great Britain market\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eHousing emergency-stop push buttons in machine control panels\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation cabinets requiring IP65 ingress protection\u003c\/li\u003e\n  \u003cli\u003eControl stations on production lines, conveyor systems, and processing equipment\u003c\/li\u003e\n  \u003cli\u003eSafety circuits where 3-times lockable enclosures are required for energy isolation\u003c\/li\u003e\n  \u003cli\u003ePendant control and pendant station assemblies\u003c\/li\u003e\n  \u003cli\u003eAny switchgear or pilot device installation demanding robust environmental sealing\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229168242971,"sku":"1SAM201911R1011","price":36.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sam201911r1011-ib132-y-emergency-stop-3x-lockable_664a2252-8661-4026-a5d6-02af6fa9fdea.webp?v=1777156056"},{"product_id":"schneider-rxze1m2c-rxz-7a-250v-relay-socket","title":"Schneider Electric RXZE1M2C RXZ Series 7A 250V Screw Clamp Relay Socket","description":"\u003cp\u003eThe Schneider Electric RXZE1M2C is an RXZ series relay socket rated at 7A and 250V, designed for secure screw clamp mounting in industrial control panels and automation systems. This compact socket — weighing just 53g — provides a reliable interface for RXZ series relays, simplifying installation and replacement in demanding industrial environments. RoHS compliant, the RXZE1M2C is a dependable choice for engineers and procurement professionals seeking quality relay accessories.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRXZE1M2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRXZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRXZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay Socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.053 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive, ensuring the product is free from restricted hazardous materials for safe use in industrial and commercial applications.\u003c\/li\u003e\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229833990427,"sku":"RXZE1M2C","price":8.37,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-rxze1m2c-clamp-relay-socket_cb19060f-b9f9-4427-b247-fd7caf59aa4b.jpg?v=1777166953"},{"product_id":"schneider-electric-ruzc3m-rxz-harmony-10a-relay-socket","title":"Schneider Electric RUZC3M RXZ Harmony Series 10A Relay Socket","description":"\u003cp\u003eThe Schneider Electric RUZC3M is a Harmony Series RXZ relay socket rated at 10A, designed for use with compatible plug-in relays in industrial control panel and automation applications. This compact socket provides a reliable, secure mounting interface for relay modules, simplifying wiring and enabling fast relay replacement without disturbing circuit connections. With a lightweight profile of just 51 g, the RUZC3M is well-suited for space-conscious panel layouts.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRUZC3M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHarmony RXZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRXZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay Socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.051 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eChina RoHS:\u003c\/strong\u003e Compliant with China's Restriction of Hazardous Substances regulations, confirming the product meets environmental material restrictions for the Chinese market.\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIndustrial control panels requiring plug-in relay mounting solutions\u003c\/li\u003e\n\u003cli\u003eFactory automation and machine control wiring systems\u003c\/li\u003e\n\u003cli\u003eBuilding automation and HVAC control circuits\u003c\/li\u003e\n\u003cli\u003eProcess control and instrumentation panels\u003c\/li\u003e\n\u003cli\u003eApplications where relay interchangeability and fast maintenance are required\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50229856600347,"sku":"RUZC3M","price":6.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ruzc3m-10a-relay-socket_dcd59828-1b4b-48e2-8e37-39123c430fde.jpg?v=1777166884"},{"product_id":"schneider-gv2g245-gv2g-3p-63a-comb-busbar","title":"Schneider Electric GV2G245 GV2G 3-Pole 63A Linergy FT Comb Busbar","description":"\u003cp\u003eThe Schneider Electric GV2G245 is a 3-pole 63A comb busbar from the Linergy FT series, designed to simplify and optimize power distribution across motor starters and protection devices in control panels. The GV2G245 enables efficient busbar interconnection, reducing wiring complexity while maintaining reliable electrical continuity in industrial automation applications. Weighing just 58 g, this compact component integrates seamlessly into Schneider Electric motor starter assemblies.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2G245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinergy FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComb Busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.058 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starter Panels:\u003c\/strong\u003e Interconnects GV2 series manual motor starters and protection circuit breakers on a common busbar for streamlined power distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Control Panels:\u003c\/strong\u003e Reduces point-to-point wiring in distribution boards and motor control centres, improving panel layout and reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomation Systems:\u003c\/strong\u003e Suitable for use in manufacturing, process, and building automation environments requiring compact and efficient busbar solutions.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230323446043,"sku":"GV2G245","price":14.26,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv2g245-ft-comb-busbar_ffac6196-5ed0-4f84-90bf-e0823da5b146.jpg?v=1777165260"},{"product_id":"schneider-gv2g254-gv2g-63a-3p-comb-busbar","title":"Schneider Electric GV2G254 GV2G 3P 63A Comb Busbar Linergy FT Series","description":"\u003cp\u003eThe Schneider Electric GV2G254 is a 63A 3-pole comb busbar from the Linergy FT series, designed to simplify power distribution wiring in compact motor starter and circuit breaker assemblies. Referenced as GV2G254 and part of the GV2G model family, this busbar enables efficient, tool-friendly interconnection of multiple devices on DIN rail, reducing wiring time and improving panel layout reliability in industrial control applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2G254\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinergy FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComb Busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.06 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starter Panels:\u003c\/strong\u003e Interconnects GV2 manual motor starters and contactors for compact multi-motor installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panel Wiring:\u003c\/strong\u003e Eliminates point-to-point wiring between adjacent devices, reducing assembly errors and panel build time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Suitable for DIN rail mounted assemblies in manufacturing, process control, and machine building environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e Distributes incoming supply across multiple 3-pole protection devices in a single busbar run.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230323544347,"sku":"GV2G254","price":14.26,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv2g254-linergy-ft-series_31ecd32b-506e-4373-b971-d0151be1810f.jpg?v=1777165264"},{"product_id":"schneider-gv2g345-gv2g-linergy-ft-63a-3p-comb-busbar","title":"Schneider Electric GV2G345 GV2G Linergy FT 3P 63A Comb Busbar","description":"\u003cp\u003eThe Schneider Electric GV2G345 is a Linergy FT series 3-pole comb busbar rated at 63A, designed to simplify power distribution wiring across multiple motor starters and protection devices in industrial control panels. The GV2G comb busbar eliminates the need for individual wire connections between adjacent devices, reducing assembly time and improving panel reliability. At just 85 g, it is a compact and lightweight solution suited for dense switchboard layouts.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2G345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinergy FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComb Busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.085 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starter Assemblies:\u003c\/strong\u003e Interconnects GV2 series manual motor starters and contactors without discrete wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Panel Wiring:\u003c\/strong\u003e Reduces wiring complexity and assembly errors in industrial switchboards and motor control centres.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Suitable for OEM machine builders and panel integrators requiring fast, reliable busbar connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e Distributes power evenly across multiple poles in compact DIN rail mounted configurations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230323708187,"sku":"GV2G345","price":11.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv2g345-63a-comb-busbar_2970ea5b-20af-47c9-b088-c1ba03988ae4.jpg?v=1777165268"},{"product_id":"schneider-gv2g445-gv2g-linergy-ft-3p-63a-comb-busbar","title":"Schneider Electric GV2G445 GV2G Linergy FT 3P 63A Comb Busbar","description":"\u003cp\u003eThe Schneider Electric GV2G445 is a Linergy FT series 3-pole 63A comb busbar designed to simplify power distribution wiring in motor starter and control panel assemblies. Reference GV2G445 connects multiple GV2 manual motor starters or similar devices along a common busbar, eliminating individual wiring runs and reducing installation time in industrial automation enclosures.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2G445\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinergy FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComb Busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starter Panels:\u003c\/strong\u003e Interconnects multiple GV2 series manual motor starters on a shared supply rail, reducing wiring complexity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Control Enclosures:\u003c\/strong\u003e Streamlines power distribution within switchgear and motor control center (MCC) assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomation Systems:\u003c\/strong\u003e Supports compact, organised panel layouts in manufacturing, HVAC, and process automation environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Machine Building:\u003c\/strong\u003e Ideal for original equipment manufacturers assembling standardised motor protection and control groups.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230323839259,"sku":"GV2G445","price":16.09,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv2g445-63a-comb-busbar_c2314eb7-ef8d-4782-b8f9-64f242d245c7.jpg?v=1777165273"},{"product_id":"schneider-gv2g454-gv3g-linergy-ft-3p-63a-comb-busbar","title":"Schneider Electric GV2G454 GV3G Linergy FT 3P 63A Comb Busbar","description":"\u003cp\u003eThe Schneider Electric GV2G454 is a GV3G Linergy FT series 3-pole 63A comb busbar designed for efficient power distribution across multiple motor starters and protective devices in industrial control panels. Engineered for seamless compatibility with Schneider Electric GV3G series components, this comb busbar simplifies wiring, reduces installation time, and improves panel reliability in demanding automation environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2G454\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV3G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinergy FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComb Busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Starter Panels:\u003c\/strong\u003e Connects multiple GV3G manual motor starters or circuit breakers via a single comb busbar, eliminating individual wiring between devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Control Panels:\u003c\/strong\u003e Ideal for factory automation and machine control cabinets requiring compact, reliable busbar power distribution up to 63A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Machine Building:\u003c\/strong\u003e Accelerates assembly in original equipment manufacturer applications where standardized Schneider Electric GV3G series components are used throughout the panel.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230323937563,"sku":"GV2G454","price":16.09,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv2g454-63a-comb-busbar_9686773e-e75d-449e-9a2c-3519535e57bf.jpg?v=1777165277"},{"product_id":"schneider-gv2g554-la1-linergy-ft-63a-comb-busbar","title":"Schneider Electric GV2G554 LA1 Linergy FT 63A Comb Busbar","description":"\u003cp\u003eThe Schneider Electric GV2G554 is a Linergy FT series LA1 comb busbar rated at 63A, designed to simplify multi-device power distribution within control panels and motor starter assemblies. This comb busbar enables efficient, space-saving parallel connection of multiple devices on a common rail, reducing wiring time and improving panel reliability. Engineered for use with Schneider Electric GV2 series components, the GV2G554 is an essential accessory for streamlined industrial automation installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2G554\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinergy FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComb Busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230324134171,"sku":"GV2G554","price":18.28,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv2g554-63a-comb-busbar_b844f35c-8a95-4c39-8780-e48f938040e3.jpg?v=1777165281"},{"product_id":"schneider-electric-vz11-vz-1p-40a-neutral-block","title":"Schneider Electric VZ11 VZ 1P 40A Neutral Block TeSys Control","description":"\u003cp\u003eThe Schneider Electric VZ11 is a 1-pole 40A neutral block from the TeSys Control series, designed for reliable neutral conductor connection in industrial control panels and automation assemblies. Rated at 40A, this compact neutral block integrates seamlessly with TeSys control components, making it an ideal choice for structured panel wiring in manufacturing, motor control centers, and process automation environments. Weighing just 0.05 kg, the VZ11 is lightweight without compromising performance.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVZ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control Centers:\u003c\/strong\u003e Provides secure neutral conductor termination within TeSys-based motor starter assemblies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Control Panels:\u003c\/strong\u003e Ideal for structured neutral wiring in automation and process control enclosures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Building:\u003c\/strong\u003e Supports compact, organised panel layouts where neutral block integration alongside contactors and overloads is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturing \u0026amp; Process Automation:\u003c\/strong\u003e Suitable for any industrial environment requiring dependable neutral connection at up to 40A.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230556295451,"sku":"VZ11","price":14.33,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-vz11-block-tesys-control_0951bf6f-813a-49b8-a294-7f6f41aedb58.jpg?v=1777167018"},{"product_id":"schneider-electric-vz12-vz-1p-80a-neutral-block","title":"Schneider Electric VZ12 VZ 1P 80A Neutral Block TeSys Control","description":"\u003cp\u003eThe Schneider Electric VZ12 is a 1-pole 80A neutral block from the TeSys Control series, designed for reliable neutral connection in industrial control panel assemblies. Engineered for use alongside TeSys contactors and starters, the VZ12 provides a compact, secure terminal point rated at 80A, weighing just 0.1 kg for easy DIN rail integration in space-constrained enclosures.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVZ12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeutral Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Control Panels:\u003c\/strong\u003e Provides a dedicated neutral connection point within motor starter and contactor assemblies built on TeSys platforms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine Automation:\u003c\/strong\u003e Supports neutral distribution in automated machinery where TeSys contactors and overload relays are deployed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM Panel Builders:\u003c\/strong\u003e Lightweight at 0.1 kg and compact in form, the VZ12 is well-suited for high-density panel construction requiring reliable 80A neutral termination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Automation:\u003c\/strong\u003e Complements TeSys control components in manufacturing lines, conveyor systems, and process control equipment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230556360987,"sku":"VZ12","price":19.37,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-vz12-block-tesys-control_90a9172c-a92a-49a2-b0aa-d2e3f5a95815.jpg?v=1777167022"},{"product_id":"siemens-8us1216-0as00-8us1-fuse","title":"Siemens 8US1216-0AS00 8US1 Fuse","description":"\u003cp\u003eThe Siemens 8US1216-0AS00 is a device adapter from the SENTRON\/SIRIUS 8US1 series. Adapter standard for 3RM1 fuse module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8US1216-0AS00\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8US1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct brand name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSENTRON\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDevice adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of mounting rails\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth of the adapter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBusbar center-to-center spacing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.084 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 8US1216-0AS00 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 8US1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619884101915,"sku":"8US1216-0AS00","price":76.62,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-8us1216-0as00.webp?v=1784368351"},{"product_id":"siemens-8us1716-0rk00-8us1-fuse","title":"Siemens 8US1716-0RK00 8US1 Fuse","description":"\u003cp\u003eThe Siemens 8US1716-0RK00 is a device adapter from the SENTRON\/SIRIUS 8US1 series. Adapter DIN rail for 3RM1 fuse module. Supplied by Stoklink for industrial and commercial low-voltage applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8US1716-0RK00\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8US1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuse\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct brand name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSENTRON\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDevice adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of the product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth of the adapter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBusbar center-to-center spacing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e109 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.109 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 8US1716-0RK00 is used in industrial control panels, distribution boards and automation systems. As part of the Siemens 8US1 range it integrates with compatible SENTRON\/SIRIUS components for a coordinated low-voltage installation. Genuine Siemens product supplied by Stoklink with fast dispatch from Türkiye.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":52619884167451,"sku":"8US1716-0RK00","price":109.14,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-8us1716-0rk00.webp?v=1784368358"},{"product_id":"mersen-m1006399-1-002-602-din-d0-switch-disconnector-multifix®-size-d02-400vac-63a-3-pole-switching-width-27mm","title":"Mersen M1006399 1.002.602 DIN D0 Switch Disconnector MULTIFIX® Size D02 400VAC 63A 3-Pole switching , width 27mm","description":"\u003cp\u003eThe \u003cstrong\u003eMersen 1.002.602\u003c\/strong\u003e (M1006399) is a dIN D0 Switch Disconnector MULTIFIX® Size D02 400VAC 63A 3-Pole switching , width 27mm from the MULTIFIX® 60 , D02 Vertical Switch Fuse Disconnector 63A, 400VAC, Triple Pole range. Genuine Mersen product, supplied worldwide by Stoklink with export shipping from Turkey.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue No\u003c\/td\u003e\n\u003ctd\u003e1.002.602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage AC IEC\u003c\/td\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmpere Rating\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilization Category\u003c\/td\u003e\n\u003ctd\u003eAC 22 B @ Ue = AC 400 V; Ie = 25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitchability\u003c\/td\u003e\n\u003ctd\u003e3-pole switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eROHS Compliant\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC or DC\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current Rating (SCCR)\u003c\/td\u003e\n\u003ctd\u003e50 kA@Ue = AC 400 V; Ie = 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Size\u003c\/td\u003e\n\u003ctd\u003eD02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign Details\u003c\/td\u003e\n\u003ctd\u003eCage Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Pollution\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power dissipation of Fuse Links Pn\u003c\/td\u003e\n\u003ctd\u003e5.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Mounting\u003c\/td\u003e\n\u003ctd\u003eBus Bar Installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct group\u003c\/td\u003e\n\u003ctd\u003eBus Bar Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConventional Free Air thermal Current With Fuse-Links Ith\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Width\u003c\/td\u003e\n\u003ctd\u003e27 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Length\u003c\/td\u003e\n\u003ctd\u003e102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Height\u003c\/td\u003e\n\u003ctd\u003e226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Quantity\u003c\/td\u003e\n\u003ctd\u003e3 EA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Weight\u003c\/td\u003e\n\u003ctd\u003e1.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Width\u003c\/td\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Length\u003c\/td\u003e\n\u003ctd\u003e245 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Height\u003c\/td\u003e\n\u003ctd\u003e135 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\/UPC\u003c\/td\u003e\n\u003ctd\u003e9008567002247\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eREACH\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mersen","offers":[{"title":"Default Title","offer_id":52621710000411,"sku":"M1006399","price":198.18,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/1.002.602.jpg?v=1784454030"},{"product_id":"mersen-p1006401-1-002-603-din-d0-switch-disconnector-multifix®-size-d02-400vac-63a-3-pole-switching-with-neutral-conductor-width-27mm","title":"Mersen P1006401 1.002.603 DIN D0 Switch Disconnector MULTIFIX® Size D02 400VAC 63A 3-Pole switching with neutral conductor , width 27mm","description":"\u003cp\u003eThe \u003cstrong\u003eMersen 1.002.603\u003c\/strong\u003e (P1006401) is a dIN D0 Switch Disconnector MULTIFIX® Size D02 400VAC 63A 3-Pole switching with neutral conductor , width 27mm from the MULTIFIX® 60 , D02 Vertical Switch Fuse Disconnector 63A, 400VAC, Triple Pole range. Genuine Mersen product, supplied worldwide by Stoklink with export shipping from Turkey.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue No\u003c\/td\u003e\n\u003ctd\u003e1.002.603\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage AC IEC\u003c\/td\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmpere Rating\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilization Category\u003c\/td\u003e\n\u003ctd\u003eAC 22 B @ Ue = AC 400 V; Ie = 25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitchability\u003c\/td\u003e\n\u003ctd\u003e4-pole switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eROHS Compliant\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC or DC\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current Rating (SCCR)\u003c\/td\u003e\n\u003ctd\u003e50 kA@Ue = AC 400 V; Ie = 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Size\u003c\/td\u003e\n\u003ctd\u003eD02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign Details\u003c\/td\u003e\n\u003ctd\u003eCage Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3-Pole+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Pollution\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power dissipation of Fuse Links Pn\u003c\/td\u003e\n\u003ctd\u003e5.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Mounting\u003c\/td\u003e\n\u003ctd\u003eBus Bar Installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct group\u003c\/td\u003e\n\u003ctd\u003eBus Bar Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConventional Free Air thermal Current With Fuse-Links Ith\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Width\u003c\/td\u003e\n\u003ctd\u003e27 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Length\u003c\/td\u003e\n\u003ctd\u003e102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Height\u003c\/td\u003e\n\u003ctd\u003e262 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Quantity\u003c\/td\u003e\n\u003ctd\u003e3 EA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Weight\u003c\/td\u003e\n\u003ctd\u003e1.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Width\u003c\/td\u003e\n\u003ctd\u003e110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Length\u003c\/td\u003e\n\u003ctd\u003e285 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Height\u003c\/td\u003e\n\u003ctd\u003e105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.44 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\/UPC\u003c\/td\u003e\n\u003ctd\u003e9008567002254\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eREACH\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mersen","offers":[{"title":"Default Title","offer_id":52621798506779,"sku":"P1006401","price":279.56,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/1.002.603.jpg?v=1784454954"},{"product_id":"mersen-r1026620-1-002-604-din-d0-switch-disconnector-multifix®-size-d02-400vac-63a-3-pole-switching-with-auxiliary-switch-width-27mm","title":"Mersen R1026620 1.002.604 DIN D0 Switch Disconnector MULTIFIX® Size D02 400VAC 63A 3-Pole switching with auxiliary switch , width 27mm","description":"\u003cp\u003eThe \u003cstrong\u003eMersen 1.002.604\u003c\/strong\u003e (R1026620) is a dIN D0 Switch Disconnector MULTIFIX® Size D02 400VAC 63A 3-Pole switching with auxiliary switch , width 27mm from the MULTIFIX® 60 , D02 Vertical Switch Fuse Disconnector 63A, 400VAC, Triple Pole range. Genuine Mersen product, supplied worldwide by Stoklink with export shipping from Turkey.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue No\u003c\/td\u003e\n\u003ctd\u003e1.002.604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage AC IEC\u003c\/td\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmpere Rating\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilization Category\u003c\/td\u003e\n\u003ctd\u003eAC 22 B @ Ue = AC 400 V; Ie = 25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitchability\u003c\/td\u003e\n\u003ctd\u003e3-pole switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eROHS Compliant\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC or DC\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current Rating (SCCR)\u003c\/td\u003e\n\u003ctd\u003e50 kA@Ue = AC 400 V; Ie = 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Size\u003c\/td\u003e\n\u003ctd\u003eD02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign Details\u003c\/td\u003e\n\u003ctd\u003eCage Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Pollution\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power dissipation of Fuse Links Pn\u003c\/td\u003e\n\u003ctd\u003e5.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Mounting\u003c\/td\u003e\n\u003ctd\u003eBus Bar Installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct group\u003c\/td\u003e\n\u003ctd\u003eBus Bar Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConventional Free Air thermal Current With Fuse-Links Ith\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Width\u003c\/td\u003e\n\u003ctd\u003e27 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Length\u003c\/td\u003e\n\u003ctd\u003e102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Height\u003c\/td\u003e\n\u003ctd\u003e226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Quantity\u003c\/td\u003e\n\u003ctd\u003e3 EA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Weight\u003c\/td\u003e\n\u003ctd\u003e1.05 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Width\u003c\/td\u003e\n\u003ctd\u003e140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Length\u003c\/td\u003e\n\u003ctd\u003e250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Height\u003c\/td\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\/UPC\u003c\/td\u003e\n\u003ctd\u003e9008567002261\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eREACH\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mersen","offers":[{"title":"Default Title","offer_id":52621877182747,"sku":"R1026620","price":213.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/PHP-D0-Vertical-Switch-Fuse-Disconnector-TypeT.jpg?v=1784455386"},{"product_id":"mersen-s1026621-1-002-605-din-d0-switch-disconnector-multifix®-size-d02-400vac-63a-3-pole-switching-with-neutral-conductor-and-auxiliary-switch-width-27mm","title":"Mersen S1026621 1.002.605 DIN D0 Switch Disconnector MULTIFIX® Size D02 400VAC 63A 3-Pole switching with neutral conductor and auxiliary switch , width 27mm","description":"\u003cp\u003eThe \u003cstrong\u003eMersen 1.002.605\u003c\/strong\u003e (S1026621) is a dIN D0 Switch Disconnector MULTIFIX® Size D02 400VAC 63A 3-Pole switching with neutral conductor and auxiliary switch , width 27mm from the MULTIFIX® 60 , D02 Vertical Switch Fuse Disconnector 63A, 400VAC, Triple Pole range. Genuine Mersen product, supplied worldwide by Stoklink with export shipping from Turkey.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalogue No\u003c\/td\u003e\n\u003ctd\u003e1.002.605\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage AC IEC\u003c\/td\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmpere Rating\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilization Category\u003c\/td\u003e\n\u003ctd\u003eAC 22 B @ Ue = AC 400 V; Ie = 25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitchability\u003c\/td\u003e\n\u003ctd\u003e4-pole switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eROHS Compliant\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC or DC\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current Rating (SCCR)\u003c\/td\u003e\n\u003ctd\u003e50 kA@Ue = AC 400 V; Ie = 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Size\u003c\/td\u003e\n\u003ctd\u003eD02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign Details\u003c\/td\u003e\n\u003ctd\u003eCage Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3-Pole+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Pollution\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power dissipation of Fuse Links Pn\u003c\/td\u003e\n\u003ctd\u003e5.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Mounting\u003c\/td\u003e\n\u003ctd\u003eBus Bar Installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct group\u003c\/td\u003e\n\u003ctd\u003eBus Bar Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConventional Free Air thermal Current With Fuse-Links Ith\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Width\u003c\/td\u003e\n\u003ctd\u003e27 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Length\u003c\/td\u003e\n\u003ctd\u003e102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Height\u003c\/td\u003e\n\u003ctd\u003e262 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Quantity\u003c\/td\u003e\n\u003ctd\u003e3 EA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Weight\u003c\/td\u003e\n\u003ctd\u003e1.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Width\u003c\/td\u003e\n\u003ctd\u003e110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Length\u003c\/td\u003e\n\u003ctd\u003e290 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSell Pack Height\u003c\/td\u003e\n\u003ctd\u003e110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003e0.44 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\/UPC\u003c\/td\u003e\n\u003ctd\u003e9008567002278\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eREACH\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mersen","offers":[{"title":"Default Title","offer_id":52621901824283,"sku":"S1026621","price":275.66,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/1.002.605.jpg?v=1784455617"},{"product_id":"schneider-electric-gv2g2ea-linergy-ft-busbar","title":"Schneider Electric GV2G2EA Linergy FT Extension Busbar 63 A 2 Tap-offs for GV2ME Automation Component","description":"\u003cp\u003eThe Schneider Electric GV2G2EA is a Linergy FT extension busbar that adds 2 more tap-offs to an existing GV2ME busbar run, rated 63 A at 690 V Ui across 3 phases. It clips onto the same 35 mm DIN rail as the GV2ME motor circuit breakers it feeds and keeps the 45 mm connection pitch so the extension lines up without adapters.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2G2EA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinergy FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComb busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca \/ TeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2ME...A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Tap-offs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFixing Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail (clipped)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnits per Package\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eUse the GV2G2EA extension busbar when a GV2ME group is already running and needs more tap-off capacity — it carries no infeed of its own, so it only works downstream of a comb busbar (a left- or right-infeed GV2G) that supplies the 3-phase incomer.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54074773831963,"sku":"GV2G2EA","price":26.73,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv2g2ea-linergy-ft-busbar.jpg?v=1790850284"},{"product_id":"schneider-electric-gv2g2la-linergy-ft-busbar","title":"Schneider Electric GV2G2LA Linergy FT Comb Busbar 63 A 2 Tap-offs Left Infeed for GV2ME Automation Component","description":"\u003cp\u003eThe Schneider Electric GV2G2LA is a Linergy FT comb busbar with 2 tap-offs and a built-in infeed module on the left side, rated 63 A at 690 V Ui across 3 phases. It parallel-wires a group of GV2ME motor circuit breakers from a single 3-phase incomer, clipping onto the same 35 mm DIN rail and keeping the 45 mm connection pitch between tap-offs.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2G2LA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinergy FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComb busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca \/ TeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2ME...A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Tap-offs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFixing Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail (clipped)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - Terminals (Infeed)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush-in terminal, 1.5...25 mm² (solid\/flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e113 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.41 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnits per Package\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe infeed side decides the panel layout: pick the GV2G2LA (left-side infeed) to match where the incoming supply conductor enters the panel relative to the GV2ME row, so the busbar run does not cross back over itself. Add a GV2G extension busbar downstream if the group needs more than 2 tap-offs.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54074774552859,"sku":"GV2G2LA","price":37.13,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv2g2la-linergy-ft-busbar.jpg?v=1790850296"},{"product_id":"schneider-electric-gv2g2ra-linergy-ft-busbar","title":"Schneider Electric GV2G2RA Linergy FT Comb Busbar 63 A 2 Tap-offs Right Infeed for GV2ME Automation Component","description":"\u003cp\u003eThe Schneider Electric GV2G2RA is a Linergy FT comb busbar with 2 tap-offs and a built-in infeed module on the right side, rated 63 A at 690 V Ui across 3 phases. It parallel-wires a group of GV2ME motor circuit breakers from a single 3-phase incomer, clipping onto the same 35 mm DIN rail and keeping the 45 mm connection pitch between tap-offs.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2G2RA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinergy FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComb busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca \/ TeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2ME...A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Tap-offs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFixing Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail (clipped)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - Terminals (Infeed)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush-in terminal, 1.5...25 mm² (solid\/flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e113 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.41 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnits per Package\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe infeed side decides the panel layout: pick the GV2G2RA (right-side infeed) to match where the incoming supply conductor enters the panel relative to the GV2ME row, so the busbar run does not cross back over itself. Add a GV2G extension busbar downstream if the group needs more than 2 tap-offs.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54074775208219,"sku":"GV2G2RA","price":37.13,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv2g2ra-linergy-ft-busbar.jpg?v=1790850308"},{"product_id":"schneider-electric-gv2g3la-linergy-ft-busbar","title":"Schneider Electric GV2G3LA Linergy FT Comb Busbar 63 A 3 Tap-offs Left Infeed for GV2ME Automation Component","description":"\u003cp\u003eThe Schneider Electric GV2G3LA is a Linergy FT comb busbar with 3 tap-offs and a built-in infeed module on the left side, rated 63 A at 690 V Ui across 3 phases. It parallel-wires a group of GV2ME motor circuit breakers from a single 3-phase incomer, clipping onto the same 35 mm DIN rail and keeping the 45 mm connection pitch between tap-offs.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2G3LA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinergy FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComb busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca \/ TeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2ME...A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Tap-offs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFixing Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail (clipped)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - Terminals (Infeed)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush-in terminal, 1.5...25 mm² (solid\/flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e158 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnits per Package\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnits per Carton\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe infeed side decides the panel layout: pick the GV2G3LA (left-side infeed) to match where the incoming supply conductor enters the panel relative to the GV2ME row, so the busbar run does not cross back over itself. Add a GV2G extension busbar downstream if the group needs more than 3 tap-offs.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54074776092955,"sku":"GV2G3LA","price":46.92,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv2g3la-linergy-ft-busbar.jpg?v=1790850321"},{"product_id":"schneider-electric-gv2g3ra-linergy-ft-busbar","title":"Schneider Electric GV2G3RA Linergy FT Comb Busbar 63 A 3 Tap-offs Right Infeed for GV2ME Automation Component","description":"\u003cp\u003eThe Schneider Electric GV2G3RA is a Linergy FT comb busbar with 3 tap-offs and a built-in infeed module on the right side, rated 63 A at 690 V Ui across 3 phases. It parallel-wires a group of GV2ME motor circuit breakers from a single 3-phase incomer, clipping onto the same 35 mm DIN rail and keeping the 45 mm connection pitch between tap-offs.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2G3RA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinergy FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComb busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca \/ TeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2ME...A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Tap-offs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFixing Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail (clipped)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - Terminals (Infeed)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush-in terminal, 1.5...25 mm² (solid\/flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e158 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.54 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnits per Package\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe infeed side decides the panel layout: pick the GV2G3RA (right-side infeed) to match where the incoming supply conductor enters the panel relative to the GV2ME row, so the busbar run does not cross back over itself. Add a GV2G extension busbar downstream if the group needs more than 3 tap-offs.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54074776813851,"sku":"GV2G3RA","price":46.92,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv2g3ra-linergy-ft-busbar.jpg?v=1790850333"},{"product_id":"schneider-electric-gv2g4ea-linergy-ft-busbar","title":"Schneider Electric GV2G4EA Linergy FT Extension Busbar 63 A 4 Tap-offs for GV2ME Automation Component","description":"\u003cp\u003eThe Schneider Electric GV2G4EA is a Linergy FT extension busbar that adds 4 more tap-offs to an existing GV2ME busbar run, rated 63 A at 690 V Ui across 3 phases. It clips onto the same 35 mm DIN rail as the GV2ME motor circuit breakers it feeds and keeps the 45 mm connection pitch so the extension lines up without adapters.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2G4EA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinergy FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComb busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca \/ TeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2ME...A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Tap-offs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFixing Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail (clipped)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e195 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnits per Package\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnits per Carton\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eUse the GV2G4EA extension busbar when a GV2ME group is already running and needs more tap-off capacity — it carries no infeed of its own, so it only works downstream of a comb busbar (a left- or right-infeed GV2G) that supplies the 3-phase incomer.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54074777567515,"sku":"GV2G4EA","price":44.44,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv2g4ea-linergy-ft-busbar.jpg?v=1790850347"},{"product_id":"schneider-electric-gv2g4la-linergy-ft-busbar","title":"Schneider Electric GV2G4LA Linergy FT Comb Busbar 63 A 4 Tap-offs Left Infeed for GV2ME Automation Component","description":"\u003cp\u003eThe Schneider Electric GV2G4LA is a Linergy FT comb busbar with 4 tap-offs and a built-in infeed module on the left side, rated 63 A at 690 V Ui across 3 phases. It parallel-wires a group of GV2ME motor circuit breakers from a single 3-phase incomer, clipping onto the same 35 mm DIN rail and keeping the 45 mm connection pitch between tap-offs.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2G4LA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinergy FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComb busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca \/ TeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2ME...A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Tap-offs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFixing Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail (clipped)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - Terminals (Infeed)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush-in terminal, 1.5...25 mm² (solid\/flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e203 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.66 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnits per Package\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnits per Carton\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe infeed side decides the panel layout: pick the GV2G4LA (left-side infeed) to match where the incoming supply conductor enters the panel relative to the GV2ME row, so the busbar run does not cross back over itself. Add a GV2G extension busbar downstream if the group needs more than 4 tap-offs.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54074778681627,"sku":"GV2G4LA","price":56.43,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv2g4la-linergy-ft-busbar.jpg?v=1790850358"},{"product_id":"schneider-electric-gv2g4ra-linergy-ft-busbar","title":"Schneider Electric GV2G4RA Linergy FT Comb Busbar 63 A 4 Tap-offs Right Infeed for GV2ME Automation Component","description":"\u003cp\u003eThe Schneider Electric GV2G4RA is a Linergy FT comb busbar with 4 tap-offs and a built-in infeed module on the right side, rated 63 A at 690 V Ui across 3 phases. It parallel-wires a group of GV2ME motor circuit breakers from a single 3-phase incomer, clipping onto the same 35 mm DIN rail and keeping the 45 mm connection pitch between tap-offs.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2G4RA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinergy FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eComb busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca \/ TeSys GV2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGV2ME...A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Tap-offs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFixing Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail (clipped)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections - Terminals (Infeed)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePush-in terminal, 1.5...25 mm² (solid\/flexible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e203 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.66 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnits per Package\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnits per Carton\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe infeed side decides the panel layout: pick the GV2G4RA (right-side infeed) to match where the incoming supply conductor enters the panel relative to the GV2ME row, so the busbar run does not cross back over itself. Add a GV2G extension busbar downstream if the group needs more than 4 tap-offs.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54074779402523,"sku":"GV2G4RA","price":56.43,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv2g4ra-linergy-ft-busbar.jpg?v=1790850371"},{"product_id":"schneider-electric-gv1g09-linergy-ft-terminal-block","title":"Schneider Electric GV1G09 Linergy FT Top Feed Terminal Block 3P 63 A 690 V Automation Component","description":"\u003cp\u003eThe Schneider Electric GV1G09 is a 3-pole top-feed terminal block from the Linergy FT range, rated 63 A at 690 V, used to supply busbar sets GV2G on TeSys GV2, TeSys Deca and TeSys U motor circuit breakers. It mounts directly onto the top terminals of the devices connected by the busbar set and connects to the supply cable through screw clamp terminals.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eGV1G09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3389110212570\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eLinergy FT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Short Name\u003c\/td\u003e\n\u003ctd\u003eGV1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTerminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange Compatibility\u003c\/td\u003e\n\u003ctd\u003eTeSys GV2, TeSys Deca, TeSys U, TeSys LS1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current (Ie)\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Location\u003c\/td\u003e\n\u003ctd\u003eTop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd\u003e690 V (IEC 60947-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections\u003c\/td\u003e\n\u003ctd\u003eScrew clamp terminals, 1.5-25 mm2 solid \/ 1.5-16 mm2 flexible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening Torque\u003c\/td\u003e\n\u003ctd\u003e1.7 N.m (screw clamp) \/ 2.2 N.m (connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePair the GV1G09 with a GV2G terminal block and a GV2 busbar set to feed a row of parallel-mounted motor starters from a single incoming cable; its IP20 rating and 690 V insulation voltage match the TeSys GV2\/Deca\/U frame it feeds.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54077010837787,"sku":"GV1G09","price":9.08,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv1g09-linergy-ft-terminal-block.jpg?v=1790874597"},{"product_id":"schneider-electric-gv3s-tesys-deca-comb-busbar","title":"Schneider Electric GV3S TeSys Deca S-Shape Comb Busbar 3P Automation Component","description":"\u003cp\u003eThe Schneider Electric GV3S is an S-shape comb busbar for the TeSys Deca range, a 3-pole connection accessory that links the power terminals of a GV3P or GV3L motor circuit breaker to an LC1D40A-D65A contactor. It replaces individual jumper wires between the two devices in a DIN-rail-mounted starter assembly, and weighs 0.104 kg per set.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eGV3S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGTIN\u003c\/td\u003e\n\u003ctd\u003e3389119410069\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eComb busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange Compatibility\u003c\/td\u003e\n\u003ctd\u003eTeSys Deca, TeSys GV3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Compatibility\u003c\/td\u003e\n\u003ctd\u003eGV3P, LC1D40A-D65A, GV3L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShape\u003c\/td\u003e\n\u003ctd\u003eS shape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.104 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits per Package\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eUse the GV3S to wire a GV3P or GV3L breaker directly to its matching LC1D40A-D65A contactor without cutting individual busbar links; its S shape accommodates the offset between the two device frames in the TeSys Deca and GV3 line, keeping the assembly compact on the DIN rail.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54077015130395,"sku":"GV3S","price":27.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-gv3s-tesys-deca-comb-busbar.jpg?v=1790874724"},{"product_id":"schneider-electric-pkf32f435-panel-mounted-angled-socket","title":"Schneider Electric PKF32F435 Mureva PK Panel-Mounted Angled 32 A 3P+N+E 380-415 V IP44 Industrial Socket","description":"\u003cp\u003eThe Schneider Electric PKF32F435 is a Mureva PK panel-mounted angled socket rated 32 A, 3P+N+E, for 380-415 V AC networks. It mounts into an equipment panel with its connector body angled away from the panel face, uses captive screw terminals, and carries an IP44 degree of protection with a 6 h ground-lug clock position. The grey (RAL 7035) housing uses red voltage-identification colour coding and a 850 °C fire-resistance rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePKF32F435\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMureva PK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShape\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAngled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P+N+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround lug clock position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCaptive screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable cross section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5-10 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP44 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIK08 (EN 62262)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850 °C (IEC 60695-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-extinguishing engineering polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage identification colour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase dimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 x 90 x 119 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.269 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60309-1\u003c\/li\u003e\n\u003cli\u003eIEC 60309-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the PKF32F435 where panel space forces the mating plug to approach at an angle rather than straight into the enclosure face — the angled body keeps the plug and cable clear of adjacent panel hardware. The IP44 rating covers general indoor use; the IP67 angled variant in the same 3P+N+E, 380-415 V configuration is the choice for outdoor or washdown locations.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080612892955,"sku":"PKF32F435","price":14.96,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-pkf32f435-mureva-pk-panel-mounted-angled-socket.jpg?v=1790935076"},{"product_id":"schneider-electric-pkf16g423-panel-mounted-socket","title":"Schneider Electric PKF16G423 Mureva PK Panel-Mounted 16 A 2P+E 200-250 V IP44 Industrial Socket","description":"\u003cp\u003eThe Schneider Electric PKF16G423 is a Mureva PK panel-mounted straight socket rated 16 A, 2P+E, for 200-250 V AC networks. It mounts flush into an equipment panel, uses captive screw terminals, and carries an IP44 degree of protection with a 6 h ground-lug clock position. The grey (RAL 7035) housing uses blue voltage-identification colour coding and a 850 °C fire-resistance rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePKF16G423\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMureva PK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShape\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround lug clock position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCaptive screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable cross section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP44 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIK08 (EN 62262)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850 °C (IEC 60695-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-extinguishing engineering polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage identification colour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase dimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 x 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 x 65 x 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.138 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60309-1\u003c\/li\u003e\n\u003cli\u003eIEC 60309-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the PKF16G423 when the socket has to sit flush in an equipment panel or enclosure door with a straight connector body behind the panel face. The IP44 rating covers general indoor industrial use; for outdoor or washdown areas the equivalent IP67 variant in the same 2P+E, 200-250 V configuration is the better fit.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080612925723,"sku":"PKF16G423","price":7.92,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-pkf16g423-mureva-pk-panel-mounted-socket.jpg?v=1790935076"},{"product_id":"schneider-electric-pkf32f723-panel-mounted-angled-socket","title":"Schneider Electric PKF32F723 Mureva PK Panel-Mounted Angled 32 A 2P+E 200-250 V IP67 Industrial Socket","description":"\u003cp\u003eThe Schneider Electric PKF32F723 is a Mureva PK panel-mounted angled socket rated 32 A, 2P+E, for 200-250 V AC networks. It mounts into an equipment panel with its connector body angled away from the panel face, uses captive screw terminals, and carries an IP67 degree of protection with a 6 h ground-lug clock position. The grey (RAL 7035) housing uses blue voltage-identification colour coding and a 850 °C fire-resistance rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePKF32F723\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMureva PK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShape\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAngled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround lug clock position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCaptive screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable cross section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5-10 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIK08 (EN 62262)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850 °C (IEC 60695-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-extinguishing engineering polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage identification colour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase dimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 x 95 x 118 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.236 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60309-1\u003c\/li\u003e\n\u003cli\u003eIEC 60309-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the PKF32F723 where panel space forces the mating plug to approach at an angle rather than straight into the enclosure face — the angled body keeps the plug and cable clear of adjacent panel hardware. The IP67 rating covers general indoor use; the IP67 angled variant in the same 2P+E, 200-250 V configuration is the choice for outdoor or washdown locations.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080613679387,"sku":"PKF32F723","price":12.6,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-pkf32f723-mureva-pk-panel-mounted-angled-socket.jpg?v=1790935088"},{"product_id":"schneider-electric-pkf16g434-panel-mounted-socket","title":"Schneider Electric PKF16G434 Mureva PK Panel-Mounted 16 A 3P+E 380-415 V IP44 Industrial Socket","description":"\u003cp\u003eThe Schneider Electric PKF16G434 is a Mureva PK panel-mounted straight socket rated 16 A, 3P+E, for 380-415 V AC networks. It mounts flush into an equipment panel, uses captive screw terminals, and carries an IP44 degree of protection with a 6 h ground-lug clock position. The grey (RAL 7035) housing uses red voltage-identification colour coding and a 850 °C fire-resistance rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePKF16G434\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMureva PK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShape\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround lug clock position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCaptive screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable cross section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP44 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIK08 (EN 62262)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850 °C (IEC 60695-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-extinguishing engineering polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage identification colour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase dimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 x 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 x 68 x 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60309-1\u003c\/li\u003e\n\u003cli\u003eIEC 60309-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the PKF16G434 when the socket has to sit flush in an equipment panel or enclosure door with a straight connector body behind the panel face. The IP44 rating covers general indoor industrial use; for outdoor or washdown areas the equivalent IP67 variant in the same 3P+E, 380-415 V configuration is the better fit.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080613712155,"sku":"PKF16G434","price":8.97,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-pkf16g434-mureva-pk-panel-mounted-socket.jpg?v=1790935088"},{"product_id":"schneider-electric-pkf32f734-panel-mounted-angled-socket","title":"Schneider Electric PKF32F734 Mureva PK Panel-Mounted Angled 32 A 3P+E 380-415 V IP67 Industrial Socket","description":"\u003cp\u003eThe Schneider Electric PKF32F734 is a Mureva PK panel-mounted angled socket rated 32 A, 3P+E, for 380-415 V AC networks. It mounts into an equipment panel with its connector body angled away from the panel face, uses captive screw terminals, and carries an IP67 degree of protection with a 6 h ground-lug clock position. The grey (RAL 7035) housing uses red voltage-identification colour coding and a 850 °C fire-resistance rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePKF32F734\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMureva PK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShape\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAngled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround lug clock position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCaptive screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable cross section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5-10 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIK08 (EN 62262)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850 °C (IEC 60695-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-extinguishing engineering polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage identification colour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase dimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 x 95 x 118 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.242 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60309-1\u003c\/li\u003e\n\u003cli\u003eIEC 60309-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the PKF32F734 where panel space forces the mating plug to approach at an angle rather than straight into the enclosure face — the angled body keeps the plug and cable clear of adjacent panel hardware. The IP67 rating covers general indoor use; the IP67 angled variant in the same 3P+E, 380-415 V configuration is the choice for outdoor or washdown locations.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080614170907,"sku":"PKF32F734","price":14.08,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-pkf32f734-mureva-pk-panel-mounted-angled-socket.jpg?v=1790935101"},{"product_id":"schneider-electric-pkf16g435-panel-mounted-socket","title":"Schneider Electric PKF16G435 Mureva PK Panel-Mounted 16 A 3P+N+E 380-415 V IP44 Industrial Socket","description":"\u003cp\u003eThe Schneider Electric PKF16G435 is a Mureva PK panel-mounted straight socket rated 16 A, 3P+N+E, for 380-415 V AC networks. It mounts flush into an equipment panel, uses captive screw terminals, and carries an IP44 degree of protection with a 6 h ground-lug clock position. The grey (RAL 7035) housing uses red voltage-identification colour coding and a 850 °C fire-resistance rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePKF16G435\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMureva PK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShape\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P+N+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround lug clock position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCaptive screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable cross section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP44 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIK08 (EN 62262)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850 °C (IEC 60695-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-extinguishing engineering polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage identification colour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase dimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 x 90 x 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.195 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60309-1\u003c\/li\u003e\n\u003cli\u003eIEC 60309-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the PKF16G435 when the socket has to sit flush in an equipment panel or enclosure door with a straight connector body behind the panel face. The IP44 rating covers general indoor industrial use; for outdoor or washdown areas the equivalent IP67 variant in the same 3P+N+E, 380-415 V configuration is the better fit.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080614203675,"sku":"PKF16G435","price":12.76,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-pkf16g435-mureva-pk-panel-mounted-socket.jpg?v=1790935102"},{"product_id":"schneider-electric-pkf32f735-panel-mounted-angled-socket","title":"Schneider Electric PKF32F735 Mureva PK Panel-Mounted Angled 32 A 3P+N+E 380-415 V IP67 Industrial Socket","description":"\u003cp\u003eThe Schneider Electric PKF32F735 is a Mureva PK panel-mounted angled socket rated 32 A, 3P+N+E, for 380-415 V AC networks. It mounts into an equipment panel with its connector body angled away from the panel face, uses captive screw terminals, and carries an IP67 degree of protection with a 6 h ground-lug clock position. The grey (RAL 7035) housing uses red voltage-identification colour coding and a 850 °C fire-resistance rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePKF32F735\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMureva PK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShape\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAngled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P+N+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround lug clock position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCaptive screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable cross section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5-10 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIK08 (EN 62262)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850 °C (IEC 60695-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-extinguishing engineering polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage identification colour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase dimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 x 102 x 121 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60309-1\u003c\/li\u003e\n\u003cli\u003eIEC 60309-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the PKF32F735 where panel space forces the mating plug to approach at an angle rather than straight into the enclosure face — the angled body keeps the plug and cable clear of adjacent panel hardware. The IP67 rating covers general indoor use; the IP67 angled variant in the same 3P+N+E, 380-415 V configuration is the choice for outdoor or washdown locations.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080615481627,"sku":"PKF32F735","price":17.22,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-pkf32f735-mureva-pk-panel-mounted-angled-socket.jpg?v=1790935114"},{"product_id":"schneider-electric-pkf16g723-panel-mounted-socket","title":"Schneider Electric PKF16G723 Mureva PK Panel-Mounted 16 A 2P+E 200-250 V IP67 Industrial Socket","description":"\u003cp\u003eThe Schneider Electric PKF16G723 is a Mureva PK panel-mounted straight socket rated 16 A, 2P+E, for 200-250 V AC networks. It mounts flush into an equipment panel, uses captive screw terminals, and carries an IP67 degree of protection with a 6 h ground-lug clock position. The grey (RAL 7035) housing uses blue voltage-identification colour coding and a 850 °C fire-resistance rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePKF16G723\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMureva PK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShape\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround lug clock position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCaptive screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable cross section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIK08 (EN 62262)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850 °C (IEC 60695-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-extinguishing engineering polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage identification colour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase dimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 x 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.148 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60309-1\u003c\/li\u003e\n\u003cli\u003eIEC 60309-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the PKF16G723 when the socket has to sit flush in an equipment panel or enclosure door with a straight connector body behind the panel face. The IP67 rating covers general indoor industrial use; for outdoor or washdown areas the equivalent IP67 variant in the same 2P+E, 200-250 V configuration is the better fit.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080615579931,"sku":"PKF16G723","price":10.29,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-pkf16g723-mureva-pk-panel-mounted-socket.jpg?v=1790935115"},{"product_id":"schneider-electric-pkf32g423-panel-mounted-socket","title":"Schneider Electric PKF32G423 Mureva PK Panel-Mounted 32 A 2P+E 200-250 V IP44 Industrial Socket","description":"\u003cp\u003eThe Schneider Electric PKF32G423 is a Mureva PK panel-mounted straight socket rated 32 A, 2P+E, for 200-250 V AC networks. It mounts flush into an equipment panel, uses captive screw terminals, and carries an IP44 degree of protection with a 6 h ground-lug clock position. The grey (RAL 7035) housing uses blue voltage-identification colour coding and a 850 °C fire-resistance rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePKF32G423\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMureva PK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShape\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround lug clock position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCaptive screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable cross section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5-10 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP44 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIK08 (EN 62262)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850 °C (IEC 60695-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-extinguishing engineering polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage identification colour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase dimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 x 90 x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.216 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60309-1\u003c\/li\u003e\n\u003cli\u003eIEC 60309-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the PKF32G423 when the socket has to sit flush in an equipment panel or enclosure door with a straight connector body behind the panel face. The IP44 rating covers general indoor industrial use; for outdoor or washdown areas the equivalent IP67 variant in the same 2P+E, 200-250 V configuration is the better fit.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080616595739,"sku":"PKF32G423","price":10.12,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-pkf32g423-mureva-pk-panel-mounted-socket.jpg?v=1790935127"},{"product_id":"schneider-electric-pkf16g734-panel-mounted-socket","title":"Schneider Electric PKF16G734 Mureva PK Panel-Mounted 16 A 3P+E 380-415 V IP67 Industrial Socket","description":"\u003cp\u003eThe Schneider Electric PKF16G734 is a Mureva PK panel-mounted straight socket rated 16 A, 3P+E, for 380-415 V AC networks. It mounts flush into an equipment panel, uses captive screw terminals, and carries an IP67 degree of protection with a 6 h ground-lug clock position. The grey (RAL 7035) housing uses red voltage-identification colour coding and a 850 °C fire-resistance rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePKF16G734\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMureva PK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShape\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround lug clock position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCaptive screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable cross section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIK08 (EN 62262)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850 °C (IEC 60695-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-extinguishing engineering polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage identification colour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase dimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 x 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 x 81 x 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.169 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60309-1\u003c\/li\u003e\n\u003cli\u003eIEC 60309-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the PKF16G734 when the socket has to sit flush in an equipment panel or enclosure door with a straight connector body behind the panel face. The IP67 rating covers general indoor industrial use; for outdoor or washdown areas the equivalent IP67 variant in the same 3P+E, 380-415 V configuration is the better fit.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080616628507,"sku":"PKF16G734","price":12.32,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-pkf16g734-mureva-pk-panel-mounted-socket.jpg?v=1790935129"},{"product_id":"schneider-electric-pkf32g434-panel-mounted-socket","title":"Schneider Electric PKF32G434 Mureva PK Panel-Mounted 32 A 3P+E 380-415 V IP44 Industrial Socket","description":"\u003cp\u003eThe Schneider Electric PKF32G434 is a Mureva PK panel-mounted straight socket rated 32 A, 3P+E, for 380-415 V AC networks. It mounts flush into an equipment panel, uses captive screw terminals, and carries an IP44 degree of protection with a 6 h ground-lug clock position. The grey (RAL 7035) housing uses red voltage-identification colour coding and a 850 °C fire-resistance rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePKF32G434\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMureva PK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShape\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround lug clock position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCaptive screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable cross section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5-10 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP44 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIK08 (EN 62262)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850 °C (IEC 60695-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-extinguishing engineering polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage identification colour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase dimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 x 90 x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.233 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60309-1\u003c\/li\u003e\n\u003cli\u003eIEC 60309-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the PKF32G434 when the socket has to sit flush in an equipment panel or enclosure door with a straight connector body behind the panel face. The IP44 rating covers general indoor industrial use; for outdoor or washdown areas the equivalent IP67 variant in the same 3P+E, 380-415 V configuration is the better fit.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080617283867,"sku":"PKF32G434","price":11.88,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-pkf32g434-mureva-pk-panel-mounted-socket.jpg?v=1790935140"},{"product_id":"schneider-electric-pkf16g735-panel-mounted-socket","title":"Schneider Electric PKF16G735 Mureva PK Panel-Mounted 16 A 3P+N+E 380-415 V IP67 Industrial Socket","description":"\u003cp\u003eThe Schneider Electric PKF16G735 is a Mureva PK panel-mounted straight socket rated 16 A, 3P+N+E, for 380-415 V AC networks. It mounts flush into an equipment panel, uses captive screw terminals, and carries an IP67 degree of protection with a 6 h ground-lug clock position. The grey (RAL 7035) housing uses red voltage-identification colour coding and a 850 °C fire-resistance rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePKF16G735\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMureva PK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShape\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P+N+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround lug clock position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCaptive screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable cross section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIK08 (EN 62262)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850 °C (IEC 60695-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-extinguishing engineering polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage identification colour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase dimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 x 90 x 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.212 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60309-1\u003c\/li\u003e\n\u003cli\u003eIEC 60309-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the PKF16G735 when the socket has to sit flush in an equipment panel or enclosure door with a straight connector body behind the panel face. The IP67 rating covers general indoor industrial use; for outdoor or washdown areas the equivalent IP67 variant in the same 3P+N+E, 380-415 V configuration is the better fit.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080617382171,"sku":"PKF16G735","price":14.08,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-pkf16g735-mureva-pk-panel-mounted-socket.jpg?v=1790935141"},{"product_id":"schneider-electric-pkf32g435-panel-mounted-socket","title":"Schneider Electric PKF32G435 Mureva PK Panel-Mounted 32 A 3P+N+E 380-415 V IP44 Industrial Socket","description":"\u003cp\u003eThe Schneider Electric PKF32G435 is a Mureva PK panel-mounted straight socket rated 32 A, 3P+N+E, for 380-415 V AC networks. It mounts flush into an equipment panel, uses captive screw terminals, and carries an IP44 degree of protection with a 6 h ground-lug clock position. The grey (RAL 7035) housing uses red voltage-identification colour coding and a 850 °C fire-resistance rating.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePKF32G435\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMureva PK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShape\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P+N+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround lug clock position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCaptive screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable cross section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5-10 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP44 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIK08 (EN 62262)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850 °C (IEC 60695-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-extinguishing engineering polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage identification colour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase dimension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 x 98 x 128 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.273 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60309-1\u003c\/li\u003e\n\u003cli\u003eIEC 60309-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the PKF32G435 when the socket has to sit flush in an equipment panel or enclosure door with a straight connector body behind the panel face. The IP44 rating covers general indoor industrial use; for outdoor or washdown areas the equivalent IP67 variant in the same 3P+N+E, 380-415 V configuration is the better fit.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080618692891,"sku":"PKF32G435","price":14.63,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-pkf32g435-mureva-pk-panel-mounted-socket.jpg?v=1790935152"},{"product_id":"schneider-electric-pkf16m423-wander-socket","title":"Schneider Electric PKF16M423 Mureva PK Wander 16 A 2P+E 200-250 V IP44 Industrial Socket","description":"\u003cp\u003eThe Schneider Electric PKF16M423 is a Mureva PK wander (extension) socket rated 16 A, 2P+E, for 200-250 V AC networks. It is an in-line (wander) connector fitted to the end of a flexible extension cable (Pg 21 cable gland entry), uses captive screw terminals, and carries an IP44 degree of protection with a 6 h ground-lug clock position. The grey (RAL 7035) housing uses blue voltage-identification colour coding.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePKF16M423\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMureva PK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWander socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWander (in-line, extension lead)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShape\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStraight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P+E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current (In)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage (Ue)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200-250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround lug clock position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCaptive screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable cross section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-4 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable outer diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8-15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable gland thread\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePg 21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable entry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFair lead \/ cable gland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP44 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIK degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIK08 (EN 62262)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850 °C (IEC 60695-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient operating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-extinguishing engineering polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBrass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGrey (RAL 7035)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage identification colour\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78 x 78 x 140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIEC 60309-1\u003c\/li\u003e\n\u003cli\u003eIEC 60309-2\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the PKF16M423 for a portable in-line connector on a flexible extension lead rather than a fixed panel or wall outlet — the Pg 21 cable gland lets it be fitted to the supply cable on site. At IP44 it tolerates damp or outdoor handling; the IP44 wander variant in the same 2P+E, 200-250 V configuration is for dry indoor extension leads.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54080618725659,"sku":"PKF16M423","price":8.2,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-pkf16m423-mureva-pk-wander-socket.jpg?v=1790935155"}],"url":"https:\/\/stoklink.com\/collections\/connectors-plugs-distribution.oembed?page=3","provider":"Stoklink","version":"1.0","type":"link"}