{"title":"Campaign","description":"\u003cp\u003eCampaign prices on selected industrial electrical parts. Prices shown are current; stock and dispatch time are shown per item.\u003c\/p\u003e","products":[{"product_id":"abb-1sda070861r1-e1-2b-1600-ekip-dip-li-3p-f-f","title":"ABB 1SDA070861R1 E1.2B 1600 Ekip Dip LI 3p F F 1600A 3P 42kA Fixed Power Circuit Breaker","description":"\u003cp\u003eThe ABB 1SDA070861R1 — catalog number \u003cstrong\u003eE1.2B 1600 Ekip Dip LI 3p F F\u003c\/strong\u003e — is a 1600A, 3-pole fixed-mount power circuit breaker from the SACE Emax2 E1.2 series, delivering a breaking capacity of 42 kA at 400 V AC. Engineered for transformer, generator, and installation protection in demanding industrial environments, this air circuit breaker combines advanced Ekip Dip LI trip unit technology with a compact fixed-frame design suited for switchboards and power distribution panels.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE1.2B 1600 Ekip Dip LI 3p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA070861R1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSACE Emax2 E1.2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eE1.2B\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644747114\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEkip Dip LI\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 mm × 296 mm × 183 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union safety, health, and environmental protection requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC:\u003c\/strong\u003e Designed and tested in accordance with IEC standards for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUL 2799:\u003c\/strong\u003e Certified to UL 2799 standard for electrical systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eATEX:\u003c\/strong\u003e Approved for use in potentially explosive atmospheres (ATEX directive compliance)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCSA:\u003c\/strong\u003e Canadian Standards Association certified for North American markets\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVDE:\u003c\/strong\u003e Tested and certified by Verband der Elektrotechnik (VDE) German electrical engineering standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Directive 2011\/65\/EU on restriction of hazardous substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC No 1907\/2006) on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU:\u003c\/strong\u003e Restriction of Hazardous Substances in electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e Compliant with EN 45555 general methods for assessing the ability of electrical and electronic equipment to be repaired, reused, and recycled\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eTransformer protection in main and sub-distribution switchboards\u003c\/li\u003e\n  \u003cli\u003eGenerator set protection and power feeder circuits\u003c\/li\u003e\n  \u003cli\u003eIndustrial installation protection in manufacturing plants and process industries\u003c\/li\u003e\n  \u003cli\u003ePower distribution panels in commercial buildings and infrastructure projects\u003c\/li\u003e\n  \u003cli\u003eApplications requiring ATEX-rated or CSA-certified breaker solutions\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228908523803,"sku":"1SDA070861R1","price":2073.24,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda070861r1-e1-2b-1600-ekip-dip-li-3p-f-f-air-circuit-breakers_07cae9d8-5056-4d5b-8c76-df097be90cff.webp?v=1777184473"},{"product_id":"siemens-s7-1200-cpu-1214c-6es7214-1ag40-0xb0","title":"Siemens S7-1200 CPU 1214C – 6ES7214-1AG40-0XB0","description":"\u003cp data-start=\"237\" data-end=\"718\"\u003eThe Siemens S7-1200 CPU 1214C is a compact and high-performance PLC designed for modern industrial automation applications. Offering reliable processing power, integrated PROFINET communication, and flexible I\/O capabilities, this CPU provides a scalable solution for machine control, factory automation, and small to mid-size process systems. With seamless integration into the TIA Portal software, it enables fast configuration, efficient programming, and simplified diagnostics.\u003c\/p\u003e\n\u003chr data-start=\"720\" data-end=\"723\"\u003e\n\u003ch2 data-start=\"725\" data-end=\"754\"\u003e\u003cstrong data-start=\"728\" data-end=\"754\"\u003eKey Technical Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"755\" data-end=\"1503\"\u003e\n\u003cli data-start=\"755\" data-end=\"779\"\u003e\n\u003cp data-start=\"757\" data-end=\"779\"\u003e\u003cstrong data-start=\"757\" data-end=\"767\"\u003eModel:\u003c\/strong\u003e CPU 1214C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"780\" data-end=\"819\"\u003e\n\u003cp data-start=\"782\" data-end=\"819\"\u003e\u003cstrong data-start=\"782\" data-end=\"798\"\u003ePart Number:\u003c\/strong\u003e 6ES7214-1AG40-0XB0\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"820\" data-end=\"901\"\u003e\n\u003cp data-start=\"822\" data-end=\"901\"\u003e\u003cstrong data-start=\"822\" data-end=\"848\"\u003eProcessor Performance:\u003c\/strong\u003e High-speed processing for machine-level automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"902\" data-end=\"1017\"\u003e\n\u003cp data-start=\"904\" data-end=\"926\"\u003e\u003cstrong data-start=\"904\" data-end=\"924\"\u003eIntegrated I\/Os:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"929\" data-end=\"1017\"\u003e\n\u003cli data-start=\"929\" data-end=\"954\"\u003e\n\u003cp data-start=\"931\" data-end=\"954\"\u003e\u003cstrong data-start=\"931\" data-end=\"952\"\u003e14 Digital Inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"957\" data-end=\"991\"\u003e\n\u003cp data-start=\"959\" data-end=\"991\"\u003e\u003cstrong data-start=\"959\" data-end=\"981\"\u003e10 Digital Outputs\u003c\/strong\u003e (relay)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"994\" data-end=\"1017\"\u003e\n\u003cp data-start=\"996\" data-end=\"1017\"\u003e\u003cstrong data-start=\"996\" data-end=\"1015\"\u003e2 Analog Inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1018\" data-end=\"1156\"\u003e\n\u003cp data-start=\"1020\" data-end=\"1050\"\u003e\u003cstrong data-start=\"1020\" data-end=\"1048\"\u003eCommunication Interface:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1053\" data-end=\"1156\"\u003e\n\u003cli data-start=\"1053\" data-end=\"1104\"\u003e\n\u003cp data-start=\"1055\" data-end=\"1104\"\u003e\u003cstrong data-start=\"1055\" data-end=\"1070\"\u003e1× PROFINET\u003c\/strong\u003e (Integrated Ethernet interface)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1107\" data-end=\"1156\"\u003e\n\u003cp data-start=\"1109\" data-end=\"1156\"\u003eSupports HMI and networked automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1157\" data-end=\"1234\"\u003e\n\u003cp data-start=\"1159\" data-end=\"1172\"\u003e\u003cstrong data-start=\"1159\" data-end=\"1170\"\u003eMemory:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1175\" data-end=\"1234\"\u003e\n\u003cli data-start=\"1175\" data-end=\"1205\"\u003e\n\u003cp data-start=\"1177\" data-end=\"1205\"\u003e\u003cstrong data-start=\"1177\" data-end=\"1196\"\u003eProgram Memory:\u003c\/strong\u003e 100 KB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1208\" data-end=\"1234\"\u003e\n\u003cp data-start=\"1210\" data-end=\"1234\"\u003e\u003cstrong data-start=\"1210\" data-end=\"1226\"\u003eData Memory:\u003c\/strong\u003e 50 KB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1235\" data-end=\"1330\"\u003e\n\u003cp data-start=\"1237\" data-end=\"1330\"\u003e\u003cstrong data-start=\"1237\" data-end=\"1265\"\u003eSignal Module Expansion:\u003c\/strong\u003e Supports additional digital, analog, and communication modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1331\" data-end=\"1373\"\u003e\n\u003cp data-start=\"1333\" data-end=\"1373\"\u003e\u003cstrong data-start=\"1333\" data-end=\"1357\"\u003eHigh-Speed Counters:\u003c\/strong\u003e Up to 100 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1374\" data-end=\"1403\"\u003e\n\u003cp data-start=\"1376\" data-end=\"1403\"\u003e\u003cstrong data-start=\"1376\" data-end=\"1393\"\u003ePower Supply:\u003c\/strong\u003e 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1404\" data-end=\"1449\"\u003e\n\u003cp data-start=\"1406\" data-end=\"1449\"\u003e\u003cstrong data-start=\"1406\" data-end=\"1432\"\u003eOperating Temperature:\u003c\/strong\u003e –20°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1450\" data-end=\"1503\"\u003e\n\u003cp data-start=\"1452\" data-end=\"1503\"\u003e\u003cstrong data-start=\"1452\" data-end=\"1477\"\u003eProgramming Software:\u003c\/strong\u003e TIA Portal (STEP 7 Basic)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1505\" data-end=\"1508\"\u003e\n\u003ch2 data-start=\"1510\" data-end=\"1537\"\u003e\u003cstrong data-start=\"1513\" data-end=\"1537\"\u003eTypical Applications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1538\" data-end=\"1771\"\u003e\n\u003cli data-start=\"1538\" data-end=\"1578\"\u003e\n\u003cp data-start=\"1540\" data-end=\"1578\"\u003eMachine automation and OEM equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1579\" data-end=\"1621\"\u003e\n\u003cp data-start=\"1581\" data-end=\"1621\"\u003eConveyor and material-handling systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1622\" data-end=\"1645\"\u003e\n\u003cp data-start=\"1624\" data-end=\"1645\"\u003ePackaging machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1646\" data-end=\"1678\"\u003e\n\u003cp data-start=\"1648\" data-end=\"1678\"\u003eHVAC and building automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1679\" data-end=\"1731\"\u003e\n\u003cp data-start=\"1681\" data-end=\"1731\"\u003eProcess monitoring and small-scale SCADA systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1732\" data-end=\"1771\"\u003e\n\u003cp data-start=\"1734\" data-end=\"1771\"\u003eIndustrial panel and MCC integrations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1773\" data-end=\"1776\"\u003e\n\u003ch2 data-start=\"1778\" data-end=\"1803\"\u003e\u003cstrong data-start=\"1781\" data-end=\"1803\"\u003eProduct Advantages\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1804\" data-end=\"2156\"\u003e\n\u003cli data-start=\"1804\" data-end=\"1855\"\u003e\n\u003cp data-start=\"1806\" data-end=\"1855\"\u003eCompact design with high processing performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1856\" data-end=\"1913\"\u003e\n\u003cp data-start=\"1858\" data-end=\"1913\"\u003eSeamless integration with Siemens TIA Portal platform\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1914\" data-end=\"1980\"\u003e\n\u003cp data-start=\"1916\" data-end=\"1980\"\u003eIntegrated PROFINET for efficient communication and networking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1981\" data-end=\"2031\"\u003e\n\u003cp data-start=\"1983\" data-end=\"2031\"\u003eLong lifecycle and industry-proven reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2032\" data-end=\"2091\"\u003e\n\u003cp data-start=\"2034\" data-end=\"2091\"\u003eFlexible expansion with a wide range of S7-1200 modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2092\" data-end=\"2156\"\u003e\n\u003cp data-start=\"2094\" data-end=\"2156\"\u003eEasy diagnostics and maintenance through built-in web server\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":51420876898587,"sku":"6ES7214-1AG40-0XB0","price":350.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7214-1ag40-0xb0-cpu-1214c-dc-dc-dc-14di-10do-2ai-1214c-6es7214-1ag40-0xb0_470bc6cb-9758-4976-8f80-cbb055e7fc58.webp?v=1777185870"},{"product_id":"1sda073674r1-yo-e1-2-e6-2-xt7-xt7m-220-240-vac-dc","title":"1SDA073674R1 YO E1.2..E6.2-XT7-XT7M 220-240 VAC\/DC","description":"","brand":"ABB","offers":[{"title":"Default Title","offer_id":51876290822427,"sku":"1SDA073674R1","price":94.22,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/stoklink-e1-2-e6-2-xt7-xt7m-220-240-vac-dc_054a8d07-9a09-447f-a450-afd7511a714c.webp?v=1777185874"},{"product_id":"schneider-electric-atv630c11n4","title":"Schneider Electric ATV630C11N4 Altivar Process ATV630 110 kW 380-480 V 3-Phase IP00 Variable Frequency Drive","description":"\u003cp\u003eThe Schneider Electric ATV630C11N4 variable speed drive is an Altivar Process ATV630 unit rated 110 kW normal duty (90 kW heavy duty), delivering 211 A continuous output current at 2.5 kHz from a 380-480 V three-phase supply. It feeds 3-phase asynchronous and synchronous motors and mounts as an IP00 wall-mount unit for water and wastewater, mining and minerals, oil and gas, and food and beverage process applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATV630C11N4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAltivar Process ATV600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Short Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATV630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3606480796036\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVariable speed drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Supply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-480 V (-15\/+10%), 50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (normal duty)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 kW \/ 150 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Power (heavy duty)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 kW \/ 125 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Output Current (normal duty)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e211 A at 2.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Output Current (heavy duty)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e173 A at 2.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Current (normal duty)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e201 A at 380 V \/ 165 A at 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Transient Current (normal duty, 60 s)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e232.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApparent Power (normal duty, 480 V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e121.8 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProspective Line Isc\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1-500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kHz nominal, 2.5-8 kHz adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus TCP, Ethernet, Modbus serial (Profibus DP V1, PROFINET, DeviceNet, CANopen, EtherNet\/IP option cards)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eI\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 discrete inputs, 3 relay outputs, 3 analogue inputs, 2 analogue outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 x 852 x 390 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2026 W forced convection at 380 V, 2.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15...50 degC (derated to 60 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eTÜV\u003c\/li\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eUL 508C\u003c\/li\u003e\n\u003cli\u003eIEC 61800-3\u003c\/li\u003e\n\u003cli\u003eIEC 61800-5-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003ePick the normal-duty rating when the load is variable-torque (fan, pump, compressor) and only needs the standard 120% overload; the heavy-duty rating trades continuous current for the deeper 150% overload constant-torque loads such as conveyors and mixers need. It shares its mounting frame and IP rating with the adjacent kW steps in the ATV630 lineup, so the choice between them comes down to the motor's continuous current draw rather than the enclosure.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSchneider lists this Altivar Process ATV630 rating for water and wastewater pumps, screw and centrifugal compressors, conveyors and mixers, mining and minerals fans and pumps, oil and gas electro-submersible and jet-fuel pumps, and food and beverage pumps and fans.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":52367668347163,"sku":"ATV630C11N4","price":7020.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-atv630c11n4-atv630-vfd.jpg?v=1790304625"}],"url":"https:\/\/stoklink.com\/collections\/campaign.oembed","provider":"Stoklink","version":"1.0","type":"link"}