{"title":"Automatic Transfer Switches (ATS)","description":"\u003cp\u003eAutomatic transfer switches (ATS) from ABB and Schneider Electric, rated from 32 A up to 1600 A in 2P to 4P versions. Stoklink lists over 280 items, including Schneider Electric TransferPacT and TruONE and ABB OXB and OTM units. We ship worldwide from Turkey and quote project volumes on request.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSchneider Electric TransferPacT in rotary controller and remotely operated versions.\u003c\/li\u003e\n\u003cli\u003eSchneider Electric TruONE and Compact ATS units.\u003c\/li\u003e\n\u003cli\u003eABB OXB automatic transfer switches with Level 2 (DIP) and Level 3 (LCD) controllers.\u003c\/li\u003e\n\u003cli\u003eABB OTM open transition units for motorized transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/ats-accessories\"\u003eATS Accessories\u003c\/a\u003e – auxiliary contacts, I\/O modules, control units and terminal shrouds.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRated current. Size for the full load on the emergency bus.\u003c\/li\u003e\n\u003cli\u003ePoles. Select 4P when the neutral must be switched.\u003c\/li\u003e\n\u003cli\u003eController level. Basic DIP-setting controllers suit simple mains-generator duty. LCD controllers add settings and display.\u003c\/li\u003e\n\u003cli\u003eTransition type. Open transition breaks before make. Check the load can tolerate the gap.\u003c\/li\u003e\n\u003cli\u003eVoltage and short-circuit rating. Match to the system and fault level.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eCan an ATS start a generator?\u003c\/h3\u003e\u003cp\u003eMost ATS controllers provide a start signal contact for the generator. Confirm the controller model and its contact rating on the datasheet.\u003c\/p\u003e\u003ch3\u003eWhat does open transition mean?\u003c\/h3\u003e\u003cp\u003eThe switch disconnects from the first source before connecting to the second. There is a short break in supply, but the two sources are never paralleled.\u003c\/p\u003e\u003ch3\u003eDo you ship outside Turkey?\u003c\/h3\u003e\u003cp\u003eYes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, and we quote project quantities on request.\u003c\/p\u003e","products":[{"product_id":"abb-1sda065523r1-ats021-automatic-transfer-switch-mutli-voltage","title":"ABB 1SDA065523R1 ATS021 Automatic Transfer Switch Mutli Voltage Automatic Transfer Switch","description":"\u003cp\u003eThe ABB 1SDA065523R1, catalog number \u003cstrong\u003eATS021 Automatic Transfer Switch Mutli Voltage\u003c\/strong\u003e, is an automatic transfer switch designed to manage seamless power source changeover in industrial and commercial electrical installations. Part of ABB's Emax series, this ATS021 Automatic Transfer Switch Mutli Voltage unit ensures continuity of supply by automatically switching between available power sources, making it essential for critical load protection and power reliability applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS021 Automatic Transfer Switch Mutli Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA065523R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic Transfer Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 × 110 × 240 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.248 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644682033\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with European Union directives for electrical equipment safety and electromagnetic compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from restricted hazardous materials per EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substance safety (EC No 1907\/2006)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAutomatic source changeover in industrial control panels and distribution boards\u003c\/li\u003e\n\u003cli\u003eCritical load protection in data centres, hospitals, and manufacturing facilities\u003c\/li\u003eBackup power switching between mains supply and generator sets\u003cli\u003eMulti-voltage network integration in commercial and industrial automation systems\u003c\/li\u003e\n\u003cli\u003eIntegration with ABB Emax air circuit breakers for complete power management solutions\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228991099163,"sku":"1SDA065523R1","price":868.1,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda065523r1-ats021-automatic-transfer-switch-mutli-voltage-auto-tran-switch-multi-voltage_a2ad5067-fa1f-4da8-b009-c40cd0f9b8b7.webp?v=1777184394"},{"product_id":"abb-1sda065524r1-ats022-auto-tran-switch-advanced-control","title":"ABB 1SDA065524R1 ATS022 AUTO.TRAN.SWITCH ADVANCED CONTROL Automatic Transfer Switch","description":"\u003cp\u003eThe ABB \u003cstrong\u003eATS022 AUTO.TRAN.SWITCH ADVANCED CONTROL\u003c\/strong\u003e (SKU: 1SDA065524R1) is an automatic transfer switch designed to ensure seamless power source changeover in critical electrical installations. Engineered for advanced control applications, this ABB ATS022 unit delivers reliable, automated switching between primary and backup supplies, protecting sensitive loads from power interruptions. Compact at 160 × 110 × 240 mm and weighing 1.803 kg, it is well-suited for integration into control panels and distribution boards.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS022 AUTO.TRAN.SWITCH ADVANCED CONTROL\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SDA065524R1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATS022\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic Transfer Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 × 110 × 240 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.803 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8015644682040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to European Union safety, health, and environmental protection requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with the Restriction of Hazardous Substances Directive, restricting use of harmful materials in electrical equipment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on the registration, evaluation, and restriction of chemical substances.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with the Waste Electrical and Electronic Equipment Directive for responsible end-of-life disposal and recycling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eAutomated power source changeover in commercial and industrial facilities\u003c\/li\u003e\n  \u003cli\u003eBackup power management for critical loads and essential circuits\u003c\/li\u003e\n  \u003cli\u003eIntegration with generators and UPS systems for uninterrupted power supply\u003c\/li\u003e\n  \u003cli\u003eControl panel and distribution board installations requiring advanced transfer switching logic\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation systems where continuous operation is essential\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50228991164699,"sku":"1SDA065524R1","price":1042.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sda065524r1-ats022-auto-tran-switch-advanced-control-auto-tran-switch-advanced-control_face0eb6-4241-405d-9f24-3b9b9074ccaa.webp?v=1777184398"},{"product_id":"abb-1sca153457r1001-oxb250e3s2qt-4p-ats","title":"ABB 1SCA153457R1001 OXB250E3S2QT TruONE 4P 200-480VAC Open Style Automatic Transfer Switch","description":"\u003cp\u003eThe ABB OXB250E3S2QT automatic transfer switch (SKU 1SCA153457R1001) is a 4-pole, open-style ATS from the TruONE series, rated for 200–480 VAC and engineered for seamless source switching in critical power infrastructure. Designed to meet the demands of industrial and commercial applications, the OXB250E3S2QT ensures reliable changeover between primary and backup power supplies, minimising downtime in control panels and distribution systems.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXB250E3S2QT\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA153457R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTruONE\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic Transfer Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200–480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen Style\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019844831\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-6-1:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear — automatic transfer switching equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-6:\u003c\/strong\u003e Low-voltage switchgear and controlgear — multiple function equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the lifetime of networked equipment and measures to improve the resource efficiency of networked equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances compliant — free from restricted substances per EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e CE marked in accordance with applicable EU directives for market access in the European Economic Area\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eCritical power backup switching in data centres, hospitals, and industrial facilities\u003c\/li\u003e\n  \u003cli\u003eGenerator-to-mains changeover in commercial buildings and infrastructure projects\u003c\/li\u003e\n  \u003cli\u003eMain distribution boards and MCC panels requiring automatic source transfer\u003c\/li\u003e\n  \u003cli\u003eIndustrial automation systems where uninterrupted power is essential\u003c\/li\u003e\n  \u003cli\u003eUtility and renewable energy installations requiring dual-source management\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229234270491,"sku":"1SCA153457R1001","price":1935.46,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca153457r1001-oxb250e3s2qt-automatic-transfer-switch_497dd88d-0b01-40ff-b516-91e40cdb4ab3.webp?v=1777157778"},{"product_id":"abb-1sca153623r1001-oxb1600e3s2qt-1600a-ats","title":"ABB 1SCA153623R1001 OXB1600E3S2QT 1600A 3-Pole 200-480VAC Open Style TruONE Automatic Transfer Switch","description":"\u003cp\u003eThe ABB OXB1600E3S2QT (SKU: 1SCA153623R1001) is a 1600A, 3-pole automatic transfer switch from the ABB TruONE series, designed for reliable source changeover in critical power applications. Rated for 200–480 VAC, this open-style ATS ensures seamless transfer between primary and backup power sources, safeguarding industrial installations, data centres, and commercial facilities against supply interruptions. The OXB1600E3S2QT delivers robust performance in demanding environments and meets the highest international electrical standards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXB1600E3S2QT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA153623R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTruONE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic Transfer Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200–480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen Style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e57.11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019846491\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-6-1:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear — transfer switching equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-6:\u003c\/strong\u003e Low-voltage switchgear and controlgear — multiple function equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the ability to recover resources from electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU Regulation (EC) No 1907\/2006 on the registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Directive 2011\/65\/EU on the restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to applicable European Union directives for the CE marking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Directive 2012\/19\/EU on waste electrical and electronic equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCritical power backup and source changeover in data centres and server rooms\u003c\/li\u003e\n\u003cli\u003eEmergency power supply systems in hospitals, healthcare facilities, and life-safety installations\u003c\/li\u003e\n\u003cli\u003eIndustrial automation panels requiring uninterrupted power continuity\u003c\/li\u003e  \u003cli\u003eCommercial buildings with standby generator integration\u003c\/li\u003e\n\u003cli\u003eInfrastructure projects including utilities, water treatment, and transportation hubs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229234663707,"sku":"1SCA153623R1001","price":5866.05,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca153623r1001-oxb1600e3s2qt-automatic-transfer-switch_2cd56cc5-c02c-4087-a210-d1ee40ea7ae9.webp?v=1777157785"},{"product_id":"abb-1sca150935r1001-oxb800e3s2qt-800a-3p-ats","title":"ABB 1SCA150935R1001 OXB800E3S2QT TruONE 800A 3-Pole 200-480VAC Open Style Automatic Transfer Switch","description":"\u003cp\u003eThe ABB OXB800E3S2QT automatic transfer switch (SKU: 1SCA150935R1001) is a 800A, 3-pole open-style ATS from the TruONE series, rated for 200–480 VAC systems. Designed for critical power continuity applications, this unit ensures seamless switchover between primary and backup power sources in industrial and commercial installations. Weighing 22.23 kg, the OXB800E3S2QT delivers robust, reliable transfer switching performance in compliance with IEC 60947-6-1 standards.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXB800E3S2QT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA150935R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTruONE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200–480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen Style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019811710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-6-1:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear — automatic transfer switching equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-6:\u003c\/strong\u003e IEC standard for low-voltage switchgear and controlgear — multiple function equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e European standard for general methods for the assessment of the ability of electrical and electronic products to be repaired, reused, or recycled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on Registration, Evaluation, Authorisation and Restriction of Chemicals — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances Directive — free from restricted hazardous materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to applicable European Union safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant for proper end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCritical power backup switching in data centres and server rooms\u003c\/li\u003e\n\u003cli\u003eAutomatic source changeover in hospitals and healthcare facilities\u003c\/li\u003e\u0026gt;\u003cli\u003eGenerator-to-mains transfer in industrial plants and manufacturing facilities\u003c\/li\u003e\n\u003cli\u003eCommercial building standby power systems\u003c\/li\u003e\n\u003cli\u003eEmergency power supply (EPS) and uninterruptible power system (UPS) integration\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\u003cdl\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat voltage range does the OXB800E3S2QT support?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe ABB OXB800E3S2QT is rated for 200–480 VAC, making it compatible with a wide range of three-phase industrial supply voltages.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eHow many poles does this automatic transfer switch have?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThis unit is a 3-pole ATS, suitable for three-phase power distribution systems.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eWhat is the mounting style of the 1SCA150935R1001?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eThe OXB800E3S2QT uses an open-style mounting configuration, suitable for integration into enclosures or switchboard assemblies.\u003c\/dd\u003e\n\u003cdt\u003e\u003cstrong\u003eIs this product CE certified?\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd\u003eYes, the OXB800E3S2QT carries CE marking and complies with IEC 60947-6-1, RoHS, and REACH requirements.\u003c\/dd\u003e\n\u003c\/dl\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229234991387,"sku":"1SCA150935R1001","price":3872.38,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca150935r1001-oxb800e3s2qt-automatic-transfer-switch_dd87f782-4ab1-4d27-96c3-aae6144a95e2.webp?v=1777157760"},{"product_id":"abb-1sca153430r1001-oxb200e3s3qt-4p-automatic-transfer-switch","title":"ABB 1SCA153430R1001 OXB200E3S3QT 4P 200-480VAC Open Style TruONE Automatic Transfer Switch","description":"\u003cp\u003eThe ABB OXB200E3S3QT (SKU: 1SCA153430R1001) is a 4-pole open-style automatic transfer switch from the ABB TruONE series, rated for 200–480 VAC operation. Designed for reliable power source changeover in critical industrial and commercial applications, this ATS ensures seamless transition between primary and backup supplies, protecting connected loads from supply interruptions. Weighing 16.27 kg, the OXB200E3S3QT is built for panel integration in demanding control environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOXB200E3S3QT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1SCA153430R1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTruONE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200–480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen Style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6417019844565\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-6-1:\u003c\/strong\u003e Low-voltage switchgear and controlgear – transfer switching equipment for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-6:\u003c\/strong\u003e Low-voltage switchgear and controlgear – multiple function equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 45555:\u003c\/strong\u003e General methods for the assessment of the energy efficiency of networked standby-capable products\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conforms to applicable European health, safety, and environmental protection standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment directive for responsible disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCritical power changeover in data centres, hospitals, and industrial facilities\u003c\/li\u003e\n\u003cli\u003eAutomatic switchover between mains supply and generator or UPS backup\u003c\/li\u003e\n\u003cli\u003eIntegration into MCC panels and centralised power distribution boards\u003c\/li\u003e\n\u003cli\u003eIndustrial automation systems requiring uninterrupted power continuity\u003c\/li\u003e\n\u003cli\u003eCommercial buildings with standby generator infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229240267035,"sku":"1SCA153430R1001","price":2477.71,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-1sca153430r1001-oxb200e3s3qt-automatic-transfer-switch_d06c3a44-f0d0-4629-9ba0-19beb26fe8bc.webp?v=1777157767"},{"product_id":"schneider-electric-tpsiso30-transferpact","title":"Schneider Electric TPSISO30 TransferPacT Terminal Shield for Frame 100 A Transfer Switch Accessory","description":"\u003cp\u003eThe Schneider Electric TPSISO30 is a terminal shield insulation accessory for TransferPacT automatic transfer switches on the 100 A frame (TA10 switch size). Supplied as a set of 2 pieces, it fits over the connection terminals with an 18 mm pitch to guard against accidental contact with live parts.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTPSISO30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory \/ Separate Part Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P, 3P or 4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuantity per Set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 x 73 x 79 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eMatch the TPSISO30 to the switch frame it is listed for (100 A); insulation accessories in the TransferPacT range are sized per frame and are not interchangeable across frame sizes. It is fitted during panel build-out wherever the installation needs extra clearance between live terminals beyond the switch's own enclosure.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078638227739,"sku":"TPSISO30","price":33.06,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tpsiso30-transferpact-terminal-shield.jpg?v=1790904508"},{"product_id":"schneider-electric-tr25d4r2504tpe-transferpact","title":"Schneider Electric TR25D4R2504TPE TransferPacT Remotely Operated 4P 250 A 400 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR25D4R2504TPE is a 4-pole, 250 A TransferPacT automatic transfer switch built on the 250 A frame, rated for remote (motorised) operation at 400 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 30 kA making capacity and a 10 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR25D4R2504TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 800 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 8 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA as a switch-disconnector alone at 400 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA for 0.5 s (15 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for power ON, red LED for alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 35 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 370 x 185.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (running), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR25D4R2504TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The 4P version switches all three phases plus neutral, so it is the pick for installations that require neutral switching, such as TN-S systems with separate PE and N. On the 250 A frame, the 250 A rating covers industrial and commercial buildings, data centres, healthcare facilities and transportation sites that need a sized-for-load source-change device rather than a built-in controller. The 10 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078638260507,"sku":"TR25D4R2504TPE","price":1432.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr25d4r2504tpe-transferpact-automatic-transfer-switch.jpg?v=1790904508"},{"product_id":"schneider-electric-tpsiso31-transferpact","title":"Schneider Electric TPSISO31 TransferPacT Terminal Shield for Frame 160 A Transfer Switch Accessory","description":"\u003cp\u003eThe Schneider Electric TPSISO31 is a terminal shield insulation accessory for TransferPacT automatic transfer switches on the 160 A frame (TA16 switch size). Supplied as a set of 3 pieces with a 30 mm connection pitch, it covers the switch terminals to protect against accidental contact with live parts.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTPSISO31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory \/ Separate Part Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P or 4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuantity per Set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89.5 x 118 x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eMatch the TPSISO31 to the switch frame it is listed for (160 A); insulation accessories in the TransferPacT range are sized per frame and are not interchangeable across frame sizes. It is fitted during panel build-out wherever the installation needs extra clearance between live terminals beyond the switch's own enclosure.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078638326043,"sku":"TPSISO31","price":33.06,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tpsiso31-transferpact-terminal-shield.jpg?v=1790904522"},{"product_id":"schneider-electric-tr63d3r3204tpe-transferpact","title":"Schneider Electric TR63D3R3204TPE TransferPacT Remotely Operated 3P 320 A 400 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR63D3R3204TPE is a 3-pole, 320 A TransferPacT automatic transfer switch built on the 630 A frame, rated for remote (motorised) operation at 400 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 40 kA making capacity and a 20 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR63D3R3204TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 800 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 12 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kA as a switch-disconnector alone at 400 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kA for 0.5 s (25 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B, AC-33A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for power ON, red LED for alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 45 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 467 x 185.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (running), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR63D3R3204TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The 3P version switches the three phase conductors, so it is the lower-cost choice for 3-wire distribution. On the 630 A frame, the 320 A rating covers industrial and commercial buildings, data centres, healthcare facilities and transportation sites that need a sized-for-load source-change device rather than a built-in controller. The 20 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078638358811,"sku":"TR63D3R3204TPE","price":2091.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr63d3r3204tpe-transferpact-automatic-transfer-switch.jpg?v=1790904523"},{"product_id":"schneider-electric-tpsiso42-transferpact","title":"Schneider Electric TPSISO42 TransferPacT Long Terminal Shield for Frame 630 A Transfer Switch Accessory","description":"\u003cp\u003eThe Schneider Electric TPSISO42 is a long terminal shield insulation accessory for TransferPacT automatic transfer switches rated for the 630 A frame, 630 A. Fitted with a 45 mm connection pitch, it extends over the longer busbar run of this frame to guard the terminals against accidental contact.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTPSISO42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong terminal shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory \/ Separate Part Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P or 4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuantity per Set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eMatch the TPSISO42 to the switch frame it is listed for (630 A); insulation accessories in the TransferPacT range are sized per frame and are not interchangeable across frame sizes. It is fitted during panel build-out wherever the installation needs extra clearance between live terminals beyond the switch's own enclosure.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078638457115,"sku":"TPSISO42","price":39.88,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tpsiso42-transferpact-long-terminal-shield.jpg?v=1790904538"},{"product_id":"schneider-electric-tr63d3r4004tpe-transferpact","title":"Schneider Electric TR63D3R4004TPE TransferPacT Remotely Operated 3P 400 A 400 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR63D3R4004TPE is a 3-pole, 400 A TransferPacT automatic transfer switch built on the 630 A frame, rated for remote (motorised) operation at 400 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 40 kA making capacity and a 20 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR63D3R4004TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 800 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 12 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kA as a switch-disconnector alone at 400 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kA for 0.5 s (25 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B, AC-33A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for power ON, red LED for alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 45 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 467 x 185.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (running), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR63D3R4004TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The 3P version switches the three phase conductors, so it is the lower-cost choice for 3-wire distribution. On the 630 A frame, the 400 A rating covers industrial and commercial buildings, data centres, healthcare facilities and transportation sites that need a sized-for-load source-change device rather than a built-in controller. The 20 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078638489883,"sku":"TR63D3R4004TPE","price":2091.1,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr63d3r4004tpe-transferpact-automatic-transfer-switch.jpg?v=1790904539"},{"product_id":"schneider-electric-tpsiso65-transferpact","title":"Schneider Electric TPSISO65 TransferPacT Interphase Barrier for Frame 250-630 A Transfer Switch Accessory","description":"\u003cp\u003eThe Schneider Electric TPSISO65 is an interphase barrier insulation accessory for TransferPacT automatic transfer switches covering the 250 A and 630 A frames (250...630 A). Supplied as a set of 3 pieces, it separates adjacent phase connections inside the switch to increase the clearance between live conductors.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTPSISO65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterphase barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory \/ Separate Part Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P or 4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A and 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250...630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuantity per Set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eMatch the TPSISO65 to the switch frame it is listed for (250 A and 630 A); insulation accessories in the TransferPacT range are sized per frame and are not interchangeable across frame sizes. It is fitted during panel build-out wherever the installation needs extra clearance between live terminals beyond the switch's own enclosure.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078638686491,"sku":"TPSISO65","price":74.91,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tpsiso65-transferpact-interphase-barrier.jpg?v=1790904549"},{"product_id":"schneider-electric-tr63d3r5004tpe-transferpact","title":"Schneider Electric TR63D3R5004TPE TransferPacT Remotely Operated 3P 500 A 400 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR63D3R5004TPE is a 3-pole, 500 A TransferPacT automatic transfer switch built on the 630 A frame, rated for remote (motorised) operation at 400 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 40 kA making capacity and a 20 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR63D3R5004TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 800 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 12 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kA as a switch-disconnector alone at 400 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kA for 0.5 s (25 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B, AC-33A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for power ON, red LED for alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 45 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 467 x 185.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (running), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR63D3R5004TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The 3P version switches the three phase conductors, so it is the lower-cost choice for 3-wire distribution. On the 630 A frame, the 500 A rating covers industrial and commercial buildings, data centres, healthcare facilities and transportation sites that need a sized-for-load source-change device rather than a built-in controller. The 20 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078638719259,"sku":"TR63D3R5004TPE","price":2163.7,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr63d3r5004tpe-transferpact-automatic-transfer-switch.jpg?v=1790904552"},{"product_id":"schneider-electric-tpsiso66-transferpact","title":"Schneider Electric TPSISO66 TransferPacT Insulation Screen for Frame 250 A Transfer Switch Accessory","description":"\u003cp\u003eThe Schneider Electric TPSISO66 is an insulation screen accessory for TransferPacT automatic transfer switches on the 250 A frame (100...250 A range). Supplied as a single piece, it fits on the rear side of source II only, shielding that connection from accidental contact.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTPSISO66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory \/ Separate Part Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P or 4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100...250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuantity per Set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eMatch the TPSISO66 to the switch frame it is listed for (250 A); insulation accessories in the TransferPacT range are sized per frame and are not interchangeable across frame sizes. It is fitted during panel build-out wherever the installation needs extra clearance between live terminals beyond the switch's own enclosure. Because it only covers source II, check which source connects where on the installed switch before ordering, rather than assuming it suits either side.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078638817563,"sku":"TPSISO66","price":26.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tpsiso66-transferpact-insulation-screen.jpg?v=1790904562"},{"product_id":"schneider-electric-tr63d3r6302tpe-transferpact","title":"Schneider Electric TR63D3R6302TPE TransferPacT Remotely Operated 3P 630 A 230 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR63D3R6302TPE is a 3-pole, 630 A TransferPacT automatic transfer switch built on the 630 A frame, rated for remote (motorised) operation at 230 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 40 kA making capacity and a 20 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR63D3R6302TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 800 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 8 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kA as a switch-disconnector alone at 230 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kA for 0.5 s (25 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B, AC-33A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for power ON, red LED for alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 35 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 467 x 186 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (running), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR63D3R6302TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The 3P version switches the three phase conductors, so it is the lower-cost choice for 3-wire distribution. On the 630 A frame, the 630 A rating covers industrial and commercial buildings, data centres, healthcare facilities and transportation sites that need a sized-for-load source-change device rather than a built-in controller. The 20 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078638883099,"sku":"TR63D3R6302TPE","price":2211.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr63d3r6302tpe-transferpact-automatic-transfer-switch.jpg?v=1790904566"},{"product_id":"schneider-electric-tpsiso67-transferpact","title":"Schneider Electric TPSISO67 TransferPacT Insulation Screen for Frame 630 A Transfer Switch Accessory","description":"\u003cp\u003eThe Schneider Electric TPSISO67 is an insulation screen accessory for TransferPacT automatic transfer switches on the 630 A frame (320...630 A range). Up to 3 pieces can be fitted across source I front side, source II rear side and the load front side of the same switch.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTPSISO67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory \/ Separate Part Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P or 4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320...630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuantity per Set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eMatch the TPSISO67 to the switch frame it is listed for (630 A); insulation accessories in the TransferPacT range are sized per frame and are not interchangeable across frame sizes. It is fitted during panel build-out wherever the installation needs extra clearance between live terminals beyond the switch's own enclosure. With three mounting positions available on the same switch, more than one TPSISO67 may be needed per device depending on how many sides require shielding.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078638915867,"sku":"TPSISO67","price":45.43,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tpsiso67-transferpact-insulation-screen.jpg?v=1790904574"},{"product_id":"schneider-electric-tr63d3r6304tpe-transferpact","title":"Schneider Electric TR63D3R6304TPE TransferPacT Remotely Operated 3P 630 A 400 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR63D3R6304TPE is a 3-pole, 630 A TransferPacT automatic transfer switch built on the 630 A frame, rated for remote (motorised) operation at 400 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 40 kA making capacity and a 20 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR63D3R6304TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 800 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 12 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kA as a switch-disconnector alone at 400 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kA for 0.5 s (25 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B, AC-33A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for power ON, red LED for alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 45 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 467 x 185.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (running), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR63D3R6304TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The 3P version switches the three phase conductors, so it is the lower-cost choice for 3-wire distribution. On the 630 A frame, the 630 A rating covers industrial and commercial buildings, data centres, healthcare facilities and transportation sites that need a sized-for-load source-change device rather than a built-in controller. The 20 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078639046939,"sku":"TR63D3R6304TPE","price":2211.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr63d3r6304tpe-transferpact-automatic-transfer-switch.jpg?v=1790904579"},{"product_id":"schneider-electric-tpsiso70-transferpact","title":"Schneider Electric TPSISO70 TransferPacT Interphase Barrier for Frame 800-1600 A Transfer Switch Accessory","description":"\u003cp\u003eThe Schneider Electric TPSISO70 is an interphase barrier insulation accessory for TransferPacT automatic transfer switches on the 800 A to 1600 A frames (800...1600 A range). Supplied as a set of 3 pieces with a 115 mm connection pitch, it separates adjacent phase connections to increase clearance between live conductors.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTPSISO70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterphase barrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory \/ Separate Part Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulation accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles Description\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P or 4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A to 1600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[In] Rated Current Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800...1600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuantity per Set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eMatch the TPSISO70 to the switch frame it is listed for (800 A to 1600 A); insulation accessories in the TransferPacT range are sized per frame and are not interchangeable across frame sizes. It is fitted during panel build-out wherever the installation needs extra clearance between live terminals beyond the switch's own enclosure.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078639112475,"sku":"TPSISO70","price":48.79,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tpsiso70-transferpact-interphase-barrier.jpg?v=1790904586"},{"product_id":"schneider-electric-tr63d4r3204tpe-transferpact","title":"Schneider Electric TR63D4R3204TPE TransferPacT Remotely Operated 4P 320 A 400 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR63D4R3204TPE is a 4-pole, 320 A TransferPacT automatic transfer switch built on the 630 A frame, rated for remote (motorised) operation at 400 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 40 kA making capacity and a 20 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR63D4R3204TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 800 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 12 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kA as a switch-disconnector alone at 400 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kA for 0.5 s (25 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B, AC-33A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for power ON, red LED for alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 45 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 467 x 185.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (running), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR63D4R3204TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The 4P version switches all three phases plus neutral, so it is the pick for installations that require neutral switching, such as TN-S systems with separate PE and N. On the 630 A frame, the 320 A rating covers industrial and commercial buildings, data centres, healthcare facilities and transportation sites that need a sized-for-load source-change device rather than a built-in controller. The 20 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078639210779,"sku":"TR63D4R3204TPE","price":2114.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr63d4r3204tpe-transferpact-automatic-transfer-switch.jpg?v=1790904592"},{"product_id":"schneider-electric-tpsoth69-transferpact","title":"Schneider Electric TPSOTH69 TransferPacT Operation Handle for Frame 250-630 A Transfer Switch Accessory","description":"\u003cp\u003eThe Schneider Electric TPSOTH69 is the manual operation handle spare part for TransferPacT automatic transfer switches on the 250 A and 630 A frames. It plugs onto the front face with IP20 protection and is used to drive the switch between positions by hand when the automatic controller is not in use.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTPSOTH69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpare part (operation handle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessory \/ Separate Part Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpare parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A and 630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuantity per Set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront face\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eKeep the TPSOTH69 on hand as a spare for any 250 A or 630 A frame TransferPacT switch: the plug-in fitting and IP20 front-face mounting mean it can be swapped in without opening the enclosure, restoring manual I-0-II control if the original handle is lost or damaged.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078639276315,"sku":"TPSOTH69","price":21.34,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tpsoth69-transferpact-operation-handle.jpg?v=1790904598"},{"product_id":"schneider-electric-tr63d4r4004tpe-transferpact","title":"Schneider Electric TR63D4R4004TPE TransferPacT Remotely Operated 4P 400 A 400 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR63D4R4004TPE is a 4-pole, 400 A TransferPacT automatic transfer switch built on the 630 A frame, rated for remote (motorised) operation at 400 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 40 kA making capacity and a 20 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR63D4R4004TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 800 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 12 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kA as a switch-disconnector alone at 400 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kA for 0.5 s (25 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B, AC-33A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for power ON, red LED for alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 45 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 467 x 185.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (running), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR63D4R4004TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The 4P version switches all three phases plus neutral, so it is the pick for installations that require neutral switching, such as TN-S systems with separate PE and N. On the 630 A frame, the 400 A rating covers industrial and commercial buildings, data centres, healthcare facilities and transportation sites that need a sized-for-load source-change device rather than a built-in controller. The 20 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078639374619,"sku":"TR63D4R4004TPE","price":2140.05,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr63d4r4004tpe-transferpact-automatic-transfer-switch.jpg?v=1790904605"},{"product_id":"schneider-electric-tr25d3r1604tpe-transferpact","title":"Schneider Electric TR25D3R1604TPE TransferPacT Remotely Operated 3P 160 A 400 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR25D3R1604TPE is a 3-pole, 160 A TransferPacT automatic transfer switch built on the 250 A frame, rated for remote (motorised) operation at 400 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 30 kA making capacity and a 10 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR25D3R1604TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 800 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 8 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA as a switch-disconnector alone at 400 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA for 0.5 s (15 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B, AC-33A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for power ON, red LED for alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 35 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 370 x 185.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (running), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR25D3R1604TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The 3P version switches the three phase conductors, so it is the lower-cost choice for 3-wire distribution. On the 250 A frame, the 160 A rating covers industrial and commercial buildings, data centres, healthcare facilities and transportation sites that need a sized-for-load source-change device rather than a built-in controller. The 10 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078639472923,"sku":"TR25D3R1604TPE","price":1285.35,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr25d3r1604tpe-transferpact-automatic-transfer-switch.jpg?v=1790904612"},{"product_id":"schneider-electric-tr63d4r5004tpe-transferpact","title":"Schneider Electric TR63D4R5004TPE TransferPacT Remotely Operated 4P 500 A 400 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR63D4R5004TPE is a 4-pole, 500 A TransferPacT automatic transfer switch built on the 630 A frame, rated for remote (motorised) operation at 400 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 40 kA making capacity and a 20 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR63D4R5004TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 800 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 12 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kA as a switch-disconnector alone at 400 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kA for 0.5 s (25 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B, AC-33A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for power ON, red LED for alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 45 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 467 x 185.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (running), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR63D4R5004TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The 4P version switches all three phases plus neutral, so it is the pick for installations that require neutral switching, such as TN-S systems with separate PE and N. On the 630 A frame, the 500 A rating covers industrial and commercial buildings, data centres, healthcare facilities and transportation sites that need a sized-for-load source-change device rather than a built-in controller. The 20 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078639571227,"sku":"TR63D4R5004TPE","price":2187.9,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr63d4r5004tpe-transferpact-automatic-transfer-switch.jpg?v=1790904621"},{"product_id":"schneider-electric-tr25d3r2004tpe-transferpact","title":"Schneider Electric TR25D3R2004TPE TransferPacT Remotely Operated 3P 200 A 400 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR25D3R2004TPE is a 3-pole, 200 A TransferPacT automatic transfer switch built on the 250 A frame, rated for remote (motorised) operation at 400 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 30 kA making capacity and a 10 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR25D3R2004TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 800 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 8 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA as a switch-disconnector alone at 400 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA for 0.5 s (15 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B, AC-33A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for power ON, red LED for alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 35 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 370 x 185.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (running), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR25D3R2004TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The 3P version switches the three phase conductors, so it is the lower-cost choice for 3-wire distribution. On the 250 A frame, the 200 A rating covers industrial and commercial buildings, data centres, healthcare facilities and transportation sites that need a sized-for-load source-change device rather than a built-in controller. The 10 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078639735067,"sku":"TR25D3R2004TPE","price":1320.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr25d3r2004tpe-transferpact-automatic-transfer-switch.jpg?v=1790904627"},{"product_id":"schneider-electric-tr63d4r6302tpe-transferpact","title":"Schneider Electric TR63D4R6302TPE TransferPacT Remotely Operated 4P 630 A 230 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR63D4R6302TPE is a 4-pole, 630 A TransferPacT automatic transfer switch built on the 630 A frame, rated for remote (motorised) operation at 230 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 40 kA making capacity and a 20 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR63D4R6302TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 800 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 8 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kA as a switch-disconnector alone at 230 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kA for 0.5 s (25 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B, AC-33A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator, remote LCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for power ON, red LED for alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 35 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 467 x 186 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (running), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR63D4R6302TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The 4P version switches all three phases plus neutral, so it is the pick for installations that require neutral switching, such as TN-S systems with separate PE and N. On the 630 A frame, the 630 A rating covers industrial and commercial buildings, data centres, healthcare facilities and transportation sites that need a sized-for-load source-change device rather than a built-in controller. The 20 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078639800603,"sku":"TR63D4R6302TPE","price":2236.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr63d4r6302tpe-transferpact-automatic-transfer-switch.jpg?v=1790904633"},{"product_id":"schneider-electric-tr25d3r2502tpe-transferpact","title":"Schneider Electric TR25D3R2502TPE TransferPacT Remotely Operated 3P 250 A 230 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR25D3R2502TPE is a 3-pole, 250 A TransferPacT automatic transfer switch built on the 250 A frame, rated for remote (motorised) operation at 230 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 30 kA making capacity and a 10 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR25D3R2502TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 800 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 8 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA as a switch-disconnector alone at 230 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA for 0.5 s (15 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B, AC-33A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for power ON, red LED for alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 35 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 370 x 185.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (running), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR25D3R2502TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The 3P version switches the three phase conductors, so it is the lower-cost choice for 3-wire distribution. On the 250 A frame, the 250 A rating covers industrial and commercial buildings, data centres, healthcare facilities and transportation sites that need a sized-for-load source-change device rather than a built-in controller. The 10 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078639833371,"sku":"TR25D3R2502TPE","price":1386.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr25d3r2502tpe-transferpact-automatic-transfer-switch.jpg?v=1790904641"},{"product_id":"schneider-electric-tr63d4r6304tpe-transferpact","title":"Schneider Electric TR63D4R6304TPE TransferPacT Remotely Operated 4P 630 A 400 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR63D4R6304TPE is a 4-pole, 630 A TransferPacT automatic transfer switch built on the 630 A frame, rated for remote (motorised) operation at 400 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 40 kA making capacity and a 20 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR63D4R6304TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 800 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 12 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kA as a switch-disconnector alone at 400 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kA for 0.5 s (25 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e630 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B, AC-33A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for power ON, red LED for alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 45 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 467 x 185.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (running), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR63D4R6304TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The 4P version switches all three phases plus neutral, so it is the pick for installations that require neutral switching, such as TN-S systems with separate PE and N. On the 630 A frame, the 630 A rating covers industrial and commercial buildings, data centres, healthcare facilities and transportation sites that need a sized-for-load source-change device rather than a built-in controller. The 20 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078639931675,"sku":"TR63D4R6304TPE","price":2236.3,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr63d4r6304tpe-transferpact-automatic-transfer-switch.jpg?v=1790904646"},{"product_id":"schneider-electric-tr25d3r2504tpe-transferpact","title":"Schneider Electric TR25D3R2504TPE TransferPacT Remotely Operated 3P 250 A 400 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR25D3R2504TPE is a 3-pole, 250 A TransferPacT automatic transfer switch built on the 250 A frame, rated for remote (motorised) operation at 400 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 30 kA making capacity and a 10 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR25D3R2504TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 800 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 8 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA as a switch-disconnector alone at 400 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA for 0.5 s (15 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for power ON, red LED for alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 35 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 370 x 185.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (running), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR25D3R2504TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The 3P version switches the three phase conductors, so it is the lower-cost choice for 3-wire distribution. On the 250 A frame, the 250 A rating covers industrial and commercial buildings, data centres, healthcare facilities and transportation sites that need a sized-for-load source-change device rather than a built-in controller. The 10 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078639964443,"sku":"TR25D3R2504TPE","price":1386.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr25d3r2504tpe-transferpact-automatic-transfer-switch.jpg?v=1790904653"},{"product_id":"schneider-electric-tr80d3r8002tpe-transferpact","title":"Schneider Electric TR80D3R8002TPE TransferPacT Remotely Operated 3P 800 A 230 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR80D3R8002TPE is a 3-pole, 800 A TransferPacT automatic transfer switch built on the 800 A frame, rated for remote (motorised) operation at 230 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 40 kA making capacity and a 20 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR80D3R8002TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 1000 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 12 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kA as a switch-disconnector alone at 400 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kA for 0.5 s (25 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator, remote LCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 45 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 467 x 186 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (automatic mode), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR80D3R8002TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The front panel carries a rotary display module for local control and setting via a rotary\/dip switch, so commissioning does not depend on the remote controller being present. The 3P version switches the three phase conductors, so it is the lower-cost choice for 3-wire distribution. The 800 A rating on the 800 A frame suits life-safety loads such as fire-fighting equipment, smoke extract fans, sprinkler pumps and emergency lighting, where the switch must carry the full load current continuously after a transfer. The 20 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078640062747,"sku":"TR80D3R8002TPE","price":2544.85,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr80d3r8002tpe-transferpact-automatic-transfer-switch.jpg?v=1790904659"},{"product_id":"schneider-electric-tr25d4r1604tpe-transferpact","title":"Schneider Electric TR25D4R1604TPE TransferPacT Remotely Operated 4P 160 A 400 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR25D4R1604TPE is a 4-pole, 160 A TransferPacT automatic transfer switch built on the 250 A frame, rated for remote (motorised) operation at 400 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 30 kA making capacity and a 10 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR25D4R1604TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 800 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 8 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA as a switch-disconnector alone at 400 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA for 0.5 s (15 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B, AC-33A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for power ON, red LED for alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 35 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 370 x 185.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (running), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR25D4R1604TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The 4P version switches all three phases plus neutral, so it is the pick for installations that require neutral switching, such as TN-S systems with separate PE and N. On the 250 A frame, the 160 A rating covers industrial and commercial buildings, data centres, healthcare facilities and transportation sites that need a sized-for-load source-change device rather than a built-in controller. The 10 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078640095515,"sku":"TR25D4R1604TPE","price":1320.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr25d4r1604tpe-transferpact-automatic-transfer-switch.jpg?v=1790904667"},{"product_id":"schneider-electric-tr80d3r8004tpe-transferpact","title":"Schneider Electric TR80D3R8004TPE TransferPacT Remotely Operated 3P 800 A 400 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR80D3R8004TPE is a 3-pole, 800 A TransferPacT automatic transfer switch built on the 800 A frame, rated for remote (motorised) operation at 400 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 40 kA making capacity and a 20 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR80D3R8004TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 1000 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 12 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kA as a switch-disconnector alone at 400 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kA for 0.5 s (25 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator, remote LCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 45 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 467 x 186 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (automatic mode), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR80D3R8004TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The front panel carries a rotary display module for local control and setting via a rotary\/dip switch, so commissioning does not depend on the remote controller being present. The 3P version switches the three phase conductors, so it is the lower-cost choice for 3-wire distribution. The 800 A rating on the 800 A frame suits life-safety loads such as fire-fighting equipment, smoke extract fans, sprinkler pumps and emergency lighting, where the switch must carry the full load current continuously after a transfer. The 20 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078640128283,"sku":"TR80D3R8004TPE","price":2544.85,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr80d3r8004tpe-transferpact-automatic-transfer-switch.jpg?v=1790904672"},{"product_id":"schneider-electric-tr25d4r2004tpe-transferpact","title":"Schneider Electric TR25D4R2004TPE TransferPacT Remotely Operated 4P 200 A 400 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR25D4R2004TPE is a 4-pole, 200 A TransferPacT automatic transfer switch built on the 250 A frame, rated for remote (motorised) operation at 400 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 30 kA making capacity and a 10 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR25D4R2004TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 800 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 8 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA as a switch-disconnector alone at 400 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA for 0.5 s (15 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B, AC-33A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for power ON, red LED for alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 35 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 370 x 185.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (running), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR25D4R2004TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The 4P version switches all three phases plus neutral, so it is the pick for installations that require neutral switching, such as TN-S systems with separate PE and N. On the 250 A frame, the 200 A rating covers industrial and commercial buildings, data centres, healthcare facilities and transportation sites that need a sized-for-load source-change device rather than a built-in controller. The 10 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078640423195,"sku":"TR25D4R2004TPE","price":1355.2,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr25d4r2004tpe-transferpact-automatic-transfer-switch.jpg?v=1790904681"},{"product_id":"schneider-electric-tr80d4r8002tpe-transferpact","title":"Schneider Electric TR80D4R8002TPE TransferPacT Remotely Operated 4P 800 A 230 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR80D4R8002TPE is a 4-pole, 800 A TransferPacT automatic transfer switch built on the 800 A frame, rated for remote (motorised) operation at 230 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 40 kA making capacity and a 20 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR80D4R8002TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 1000 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 12 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kA as a switch-disconnector alone at 400 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kA for 0.5 s (25 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator, remote LCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 45 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 467 x 186 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (automatic mode), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR80D4R8002TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The front panel carries a rotary display module for local control and setting via a rotary\/dip switch, so commissioning does not depend on the remote controller being present. The 4P version switches all three phases plus neutral, so it is the pick for installations that require neutral switching, such as TN-S systems with separate PE and N. The 800 A rating on the 800 A frame suits life-safety loads such as fire-fighting equipment, smoke extract fans, sprinkler pumps and emergency lighting, where the switch must carry the full load current continuously after a transfer. The 20 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078640455963,"sku":"TR80D4R8002TPE","price":2700.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr80d4r8002tpe-transferpact-automatic-transfer-switch.jpg?v=1790904686"},{"product_id":"schneider-electric-tr25d4r2502tpe-transferpact","title":"Schneider Electric TR25D4R2502TPE TransferPacT Remotely Operated 4P 250 A 230 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR25D4R2502TPE is a 4-pole, 250 A TransferPacT automatic transfer switch built on the 250 A frame, rated for remote (motorised) operation at 230 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 30 kA making capacity and a 10 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR25D4R2502TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 800 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 8 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 kA as a switch-disconnector alone at 230 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA for 0.5 s (15 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B, AC-33A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocal Signalling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED for power ON, red LED for alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 35 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 370 x 185.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (running), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR25D4R2502TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The 4P version switches all three phases plus neutral, so it is the pick for installations that require neutral switching, such as TN-S systems with separate PE and N. On the 250 A frame, the 250 A rating covers industrial and commercial buildings, data centres, healthcare facilities and transportation sites that need a sized-for-load source-change device rather than a built-in controller. The 10 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078640587035,"sku":"TR25D4R2502TPE","price":1423.95,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr25d4r2502tpe-transferpact-automatic-transfer-switch.jpg?v=1790904694"},{"product_id":"schneider-electric-tr80d4r8004tpe-transferpact","title":"Schneider Electric TR80D4R8004TPE TransferPacT Remotely Operated 4P 800 A 400 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TR80D4R8004TPE is a 4-pole, 800 A TransferPacT automatic transfer switch built on the 800 A frame, rated for remote (motorised) operation at 400 V AC, 50\/60 Hz. Driven by an external controller rather than a built-in display, it switches the load between two power sources, carrying a 40 kA making capacity and a 20 kA\/0.5 s short-time withstand current for coordination with upstream protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTR80D4R8004TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or Component Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] Rated Operational Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] Rated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] Rated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 1000 V, controller 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] Rated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch 12 kV, controller 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] Rated Short-Circuit Making Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kA as a switch-disconnector alone at 400 V AC, 50 Hz, rising to 330 kA with an upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] Rated Short-Time Withstand Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kA for 0.5 s (25 kA for 0.1 s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] Conventional Free Air Thermal Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilisation Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Switch Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual or remote\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlarm indicator, remote LCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, fixed mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed upside and downside, 45 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e341 x 467 x 186 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP Degree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (automatic mode), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eBecause the TR80D4R8004TPE is the remote-operated (TR) version, it has no built-in TPC controller: the transfer logic and I\/O live in an external controller, so it suits installations that already standardise on one controller platform across several switches. The front panel carries a rotary display module for local control and setting via a rotary\/dip switch, so commissioning does not depend on the remote controller being present. The 4P version switches all three phases plus neutral, so it is the pick for installations that require neutral switching, such as TN-S systems with separate PE and N. The 800 A rating on the 800 A frame suits life-safety loads such as fire-fighting equipment, smoke extract fans, sprinkler pumps and emergency lighting, where the switch must carry the full load current continuously after a transfer. The 20 kA\/0.5 s short-time withstand current sets how long it can carry a downstream fault before the upstream breaker must clear it, which is the figure to check against the protection device's tripping curve.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078640619803,"sku":"TR80D4R8004TPE","price":2700.5,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-tr80d4r8004tpe-transferpact-automatic-transfer-switch.jpg?v=1790904699"},{"product_id":"schneider-electric-ta10d3s0324tpe-transferpact-ats","title":"Schneider Electric TA10D3S0324TPE TransferPacT 3P 32 A 400 V Rotary Controller Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TA10D3S0324TPE is a 3P TransferPacT automatic transfer switch rated for 32 A at 400 V AC, built on the 32-100 A TA10 frame. It switches a load between two AC supply sources through 3 contact positions with mechanical and electrical position indication, and its front rotary knob and selector switch give local manual control for automatic or manual operation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTA10D3S0324TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 800 V, Controller: 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 6 kV, Controller: 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] rated short-circuit making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA (switch-disconnector alone), 75 kA (with upstream protection circuit breaker), 400 V AC at 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kA during 0.1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer switch class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of contact positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRotary knob, selector switch (no display)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical interlocking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePadlock in OFF position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (front, automatic mode), IP20 (inside enclosure, manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310 x 147 x 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe rotary knob and selector switch give local manual control without a display, which keeps the front panel simpler than the LCD-controller version on the same TA10 frame; choose that LCD variant instead where remote status and alarm detail at the panel matter. The 32 A rating sits within the 32-100 A TA10 frame shared with the 40 A, 50 A, 63 A, 80 A siblings; pick a higher-current sibling if the connected load draws more than 32 A, since the enclosure and mounting dimensions stay identical across the frame. As a 3-pole switch it transfers the three phase conductors only, relying on a shared neutral between the two sources; the 4P version in the same frame switches the neutral as well.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eTransferPacT automatic transfer switches of this frame are used to change the power source for life-safety and continuity-critical loads such as fire-fighting equipment, smoke extraction fans, sprinkler pumps and emergency lighting in industrial and commercial buildings, data centers, healthcare facilities and transportation infrastructure, mounted inside a power distribution cabinet on DIN rail or plate.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078640849179,"sku":"TA10D3S0324TPE","price":613.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ta10d3s0324tpe-transferpact-automatic-transfer-switch.jpg?v=1790904711"},{"product_id":"schneider-electric-ta10d3s0404tpe-transferpact-ats","title":"Schneider Electric TA10D3S0404TPE TransferPacT 3P 40 A 400 V Rotary Controller Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TA10D3S0404TPE is a 3P TransferPacT automatic transfer switch rated for 40 A at 400 V AC, built on the 32-100 A TA10 frame. It switches a load between two AC supply sources through 3 contact positions with mechanical and electrical position indication, and its front rotary knob and selector switch give local manual control for automatic or manual operation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTA10D3S0404TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 800 V, Controller: 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 6 kV, Controller: 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] rated short-circuit making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA (switch-disconnector alone), 75 kA (with upstream protection circuit breaker), 400 V AC at 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kA during 0.1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer switch class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of contact positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRotary knob, selector switch (no display)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical interlocking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePadlock in OFF position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (front, automatic mode), IP20 (inside enclosure, manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310 x 147 x 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe rotary knob and selector switch give local manual control without a display, which keeps the front panel simpler than the LCD-controller version on the same TA10 frame; choose that LCD variant instead where remote status and alarm detail at the panel matter. The 40 A rating sits within the 32-100 A TA10 frame shared with the 32 A, 50 A, 63 A, 80 A siblings; pick a higher-current sibling if the connected load draws more than 40 A, since the enclosure and mounting dimensions stay identical across the frame. As a 3-pole switch it transfers the three phase conductors only, relying on a shared neutral between the two sources; the 4P version in the same frame switches the neutral as well.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eTransferPacT automatic transfer switches of this frame are used to change the power source for life-safety and continuity-critical loads such as fire-fighting equipment, smoke extraction fans, sprinkler pumps and emergency lighting in industrial and commercial buildings, data centers, healthcare facilities and transportation infrastructure, mounted inside a power distribution cabinet on DIN rail or plate.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078641176859,"sku":"TA10D3S0404TPE","price":613.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ta10d3s0404tpe-transferpact-automatic-transfer-switch.jpg?v=1790904725"},{"product_id":"schneider-electric-ta10d2l0323tpe-transferpact-ats","title":"Schneider Electric TA10D2L0323TPE TransferPacT Active 2P 32 A 230 V LCD Controller Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TA10D2L0323TPE is a 2P TransferPacT Active automatic transfer switch rated for 32 A at 230 V AC, built on the 32-100 A TA10 frame. It switches a load between two AC supply sources through 3 contact positions with mechanical and electrical position indication, and its front-mounted LCD screen displays status and alarm settings for automatic or manual operation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTA10D2L0323TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 800 V, Controller: 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 6 kV, Controller: 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] rated short-circuit making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA (switch-disconnector alone), 75 kA (with upstream protection circuit breaker), 400 V AC at 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kA during 0.1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer switch class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of contact positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD screen, 4 push-button control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical interlocking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePadlock in OFF position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (front, automatic mode), IP20 (inside enclosure, manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310 x 147 x 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LCD controller displays status and alarm setting locally through its screen and is operated with 4 push-buttons, which gives more configuration and diagnostic detail than the rotary-knob version built on the same TA10 frame; choose that rotary variant instead where only basic manual override is needed. The 32 A rating sits within the 32-100 A TA10 frame shared with the 40 A, 50 A, 63 A, 80 A siblings; pick a higher-current sibling if the connected load draws more than 32 A, since the enclosure and mounting dimensions stay identical across the frame. Being a 2-pole switch, it is sized for single-phase change-of-source duty rather than 3-phase distribution, where the 3P or 4P versions in the same frame apply.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eTransferPacT automatic transfer switches of this frame are used to change the power source for life-safety and continuity-critical loads such as fire-fighting equipment, smoke extraction fans, sprinkler pumps and emergency lighting in industrial and commercial buildings, data centers, healthcare facilities and transportation infrastructure, mounted inside a power distribution cabinet on DIN rail or plate.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078641209627,"sku":"TA10D2L0323TPE","price":661.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ta10d2l0323tpe-transferpact-automatic-transfer-switch.jpg?v=1790904728"},{"product_id":"schneider-electric-ta10d3s0504tpe-transferpact-ats","title":"Schneider Electric TA10D3S0504TPE TransferPacT 3P 50 A 400 V Rotary Controller Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TA10D3S0504TPE is a 3P TransferPacT automatic transfer switch rated for 50 A at 400 V AC, built on the 32-100 A TA10 frame. It switches a load between two AC supply sources through 3 contact positions with mechanical and electrical position indication, and its front rotary knob and selector switch give local manual control for automatic or manual operation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTA10D3S0504TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 800 V, Controller: 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 6 kV, Controller: 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] rated short-circuit making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA (switch-disconnector alone), 75 kA (with upstream protection circuit breaker), 400 V AC at 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kA during 0.1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer switch class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of contact positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRotary knob, selector switch (no display)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical interlocking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePadlock in OFF position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (front, automatic mode), IP20 (inside enclosure, manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310 x 147 x 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe rotary knob and selector switch give local manual control without a display, which keeps the front panel simpler than the LCD-controller version on the same TA10 frame; choose that LCD variant instead where remote status and alarm detail at the panel matter. The 50 A rating sits within the 32-100 A TA10 frame shared with the 32 A, 40 A, 63 A, 80 A siblings; pick a higher-current sibling if the connected load draws more than 50 A, since the enclosure and mounting dimensions stay identical across the frame. As a 3-pole switch it transfers the three phase conductors only, relying on a shared neutral between the two sources; the 4P version in the same frame switches the neutral as well.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eTransferPacT automatic transfer switches of this frame are used to change the power source for life-safety and continuity-critical loads such as fire-fighting equipment, smoke extraction fans, sprinkler pumps and emergency lighting in industrial and commercial buildings, data centers, healthcare facilities and transportation infrastructure, mounted inside a power distribution cabinet on DIN rail or plate.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078641242395,"sku":"TA10D3S0504TPE","price":613.25,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ta10d3s0504tpe-transferpact-automatic-transfer-switch.jpg?v=1790904738"},{"product_id":"schneider-electric-ta10d2l0403tpe-transferpact-ats","title":"Schneider Electric TA10D2L0403TPE TransferPacT Active 2P 40 A 230 V LCD Controller Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TA10D2L0403TPE is a 2P TransferPacT Active automatic transfer switch rated for 40 A at 230 V AC, built on the 32-100 A TA10 frame. It switches a load between two AC supply sources through 3 contact positions with mechanical and electrical position indication, and its front-mounted LCD screen displays status and alarm settings for automatic or manual operation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTA10D2L0403TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 800 V, Controller: 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 6 kV, Controller: 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] rated short-circuit making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA (switch-disconnector alone), 75 kA (with upstream protection circuit breaker), 400 V AC at 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kA during 0.1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer switch class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of contact positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD screen, 4 push-button control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical interlocking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePadlock in OFF position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (front, automatic mode), IP20 (inside enclosure, manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310 x 147 x 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LCD controller displays status and alarm setting locally through its screen and is operated with 4 push-buttons, which gives more configuration and diagnostic detail than the rotary-knob version built on the same TA10 frame; choose that rotary variant instead where only basic manual override is needed. The 40 A rating sits within the 32-100 A TA10 frame shared with the 32 A, 50 A, 63 A, 80 A siblings; pick a higher-current sibling if the connected load draws more than 40 A, since the enclosure and mounting dimensions stay identical across the frame. Being a 2-pole switch, it is sized for single-phase change-of-source duty rather than 3-phase distribution, where the 3P or 4P versions in the same frame apply.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eTransferPacT automatic transfer switches of this frame are used to change the power source for life-safety and continuity-critical loads such as fire-fighting equipment, smoke extraction fans, sprinkler pumps and emergency lighting in industrial and commercial buildings, data centers, healthcare facilities and transportation infrastructure, mounted inside a power distribution cabinet on DIN rail or plate.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078641340699,"sku":"TA10D2L0403TPE","price":661.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ta10d2l0403tpe-transferpact-automatic-transfer-switch.jpg?v=1790904742"},{"product_id":"schneider-electric-ta10d3s0634tpe-transferpact-ats","title":"Schneider Electric TA10D3S0634TPE TransferPacT 3P 63 A 400 V Rotary Controller Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TA10D3S0634TPE is a 3P TransferPacT automatic transfer switch rated for 63 A at 400 V AC, built on the 32-100 A TA10 frame. It switches a load between two AC supply sources through 3 contact positions with mechanical and electrical position indication, and its front rotary knob and selector switch give local manual control for automatic or manual operation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTA10D3S0634TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 800 V, Controller: 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 6 kV, Controller: 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] rated short-circuit making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA (switch-disconnector alone), 75 kA (with upstream protection circuit breaker), 400 V AC at 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kA during 0.1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer switch class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of contact positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRotary knob, selector switch (no display)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical interlocking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePadlock in OFF position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (front, automatic mode), IP20 (inside enclosure, manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310 x 147 x 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe rotary knob and selector switch give local manual control without a display, which keeps the front panel simpler than the LCD-controller version on the same TA10 frame; choose that LCD variant instead where remote status and alarm detail at the panel matter. The 63 A rating sits within the 32-100 A TA10 frame shared with the 32 A, 40 A, 50 A, 80 A siblings; pick a higher-current sibling if the connected load draws more than 63 A, since the enclosure and mounting dimensions stay identical across the frame. As a 3-pole switch it transfers the three phase conductors only, relying on a shared neutral between the two sources; the 4P version in the same frame switches the neutral as well.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eTransferPacT automatic transfer switches of this frame are used to change the power source for life-safety and continuity-critical loads such as fire-fighting equipment, smoke extraction fans, sprinkler pumps and emergency lighting in industrial and commercial buildings, data centers, healthcare facilities and transportation infrastructure, mounted inside a power distribution cabinet on DIN rail or plate.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078641439003,"sku":"TA10D3S0634TPE","price":618.75,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ta10d3s0634tpe-transferpact-automatic-transfer-switch.jpg?v=1790904750"},{"product_id":"schneider-electric-ta10d2l0503tpe-transferpact-ats","title":"Schneider Electric TA10D2L0503TPE TransferPacT Active 2P 50 A 230 V LCD Controller Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TA10D2L0503TPE is a 2P TransferPacT Active automatic transfer switch rated for 50 A at 230 V AC, built on the 32-100 A TA10 frame. It switches a load between two AC supply sources through 3 contact positions with mechanical and electrical position indication, and its front-mounted LCD screen displays status and alarm settings for automatic or manual operation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTA10D2L0503TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 800 V, Controller: 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 6 kV, Controller: 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] rated short-circuit making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA (switch-disconnector alone), 75 kA (with upstream protection circuit breaker), 400 V AC at 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kA during 0.1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer switch class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of contact positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD screen, 4 push-button control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical interlocking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePadlock in OFF position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (front, automatic mode), IP20 (inside enclosure, manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310 x 147 x 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LCD controller displays status and alarm setting locally through its screen and is operated with 4 push-buttons, which gives more configuration and diagnostic detail than the rotary-knob version built on the same TA10 frame; choose that rotary variant instead where only basic manual override is needed. The 50 A rating sits within the 32-100 A TA10 frame shared with the 32 A, 40 A, 63 A, 80 A siblings; pick a higher-current sibling if the connected load draws more than 50 A, since the enclosure and mounting dimensions stay identical across the frame. Being a 2-pole switch, it is sized for single-phase change-of-source duty rather than 3-phase distribution, where the 3P or 4P versions in the same frame apply.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eTransferPacT automatic transfer switches of this frame are used to change the power source for life-safety and continuity-critical loads such as fire-fighting equipment, smoke extraction fans, sprinkler pumps and emergency lighting in industrial and commercial buildings, data centers, healthcare facilities and transportation infrastructure, mounted inside a power distribution cabinet on DIN rail or plate.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078641504539,"sku":"TA10D2L0503TPE","price":661.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ta10d2l0503tpe-transferpact-automatic-transfer-switch.jpg?v=1790904755"},{"product_id":"schneider-electric-ta10d3s0804tpe-transferpact-ats","title":"Schneider Electric TA10D3S0804TPE TransferPacT 3P 80 A 400 V Rotary Controller Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TA10D3S0804TPE is a 3P TransferPacT automatic transfer switch rated for 80 A at 400 V AC, built on the 32-100 A TA10 frame. It switches a load between two AC supply sources through 3 contact positions with mechanical and electrical position indication, and its front rotary knob and selector switch give local manual control for automatic or manual operation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTA10D3S0804TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 800 V, Controller: 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 6 kV, Controller: 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] rated short-circuit making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA (switch-disconnector alone), 75 kA (with upstream protection circuit breaker), 400 V AC at 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kA during 0.1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-32B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer switch class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of contact positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRotary knob, selector switch (no display)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical interlocking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePadlock in OFF position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (front, automatic mode), IP20 (inside enclosure, manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310 x 147 x 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe rotary knob and selector switch give local manual control without a display, which keeps the front panel simpler than the LCD-controller version on the same TA10 frame; choose that LCD variant instead where remote status and alarm detail at the panel matter. This 80 A switch carries utilization category AC-32B rather than the AC-33B used by the lower-current siblings in the same frame, reflecting the higher current duty point at the top of the 32-100 A range. The 80 A rating sits within the 32-100 A TA10 frame shared with the 32 A, 40 A, 50 A, 63 A siblings; pick a higher-current sibling if the connected load draws more than 80 A, since the enclosure and mounting dimensions stay identical across the frame. As a 3-pole switch it transfers the three phase conductors only, relying on a shared neutral between the two sources; the 4P version in the same frame switches the neutral as well.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eTransferPacT automatic transfer switches of this frame are used to change the power source for life-safety and continuity-critical loads such as fire-fighting equipment, smoke extraction fans, sprinkler pumps and emergency lighting in industrial and commercial buildings, data centers, healthcare facilities and transportation infrastructure, mounted inside a power distribution cabinet on DIN rail or plate.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078641602843,"sku":"TA10D3S0804TPE","price":673.2,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ta10d3s0804tpe-transferpact-automatic-transfer-switch.jpg?v=1790904763"},{"product_id":"schneider-electric-ta10d2l0633tpe-transferpact-ats","title":"Schneider Electric TA10D2L0633TPE TransferPacT Active 2P 63 A 230 V LCD Controller Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TA10D2L0633TPE is a 2P TransferPacT Active automatic transfer switch rated for 63 A at 230 V AC, built on the 32-100 A TA10 frame. It switches a load between two AC supply sources through 3 contact positions with mechanical and electrical position indication, and its front-mounted LCD screen displays status and alarm settings for automatic or manual operation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTA10D2L0633TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 800 V, Controller: 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 6 kV, Controller: 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] rated short-circuit making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA (switch-disconnector alone), 75 kA (with upstream protection circuit breaker), 400 V AC at 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kA during 0.1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer switch class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of contact positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD screen, 4 push-button control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical interlocking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePadlock in OFF position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (front, automatic mode), IP20 (inside enclosure, manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310 x 147 x 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LCD controller displays status and alarm setting locally through its screen and is operated with 4 push-buttons, which gives more configuration and diagnostic detail than the rotary-knob version built on the same TA10 frame; choose that rotary variant instead where only basic manual override is needed. The 63 A rating sits within the 32-100 A TA10 frame shared with the 32 A, 40 A, 50 A, 80 A siblings; pick a higher-current sibling if the connected load draws more than 63 A, since the enclosure and mounting dimensions stay identical across the frame. Being a 2-pole switch, it is sized for single-phase change-of-source duty rather than 3-phase distribution, where the 3P or 4P versions in the same frame apply.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eTransferPacT automatic transfer switches of this frame are used to change the power source for life-safety and continuity-critical loads such as fire-fighting equipment, smoke extraction fans, sprinkler pumps and emergency lighting in industrial and commercial buildings, data centers, healthcare facilities and transportation infrastructure, mounted inside a power distribution cabinet on DIN rail or plate.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078641733915,"sku":"TA10D2L0633TPE","price":675.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ta10d2l0633tpe-transferpact-automatic-transfer-switch.jpg?v=1790904769"},{"product_id":"schneider-electric-ta10d3s1004tpe-transferpact-ats","title":"Schneider Electric TA10D3S1004TPE TransferPacT 3P 100 A 400 V Rotary Controller Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TA10D3S1004TPE is a 3P TransferPacT automatic transfer switch rated for 100 A at 400 V AC, built on the 32-100 A TA10 frame. It switches a load between two AC supply sources through 3 contact positions with mechanical and electrical position indication, and its front rotary knob and selector switch give local manual control for automatic or manual operation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTA10D3S1004TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 800 V, Controller: 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 6 kV, Controller: 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] rated short-circuit making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA (switch-disconnector alone), 75 kA (with upstream protection circuit breaker), 400 V AC at 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kA during 0.1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-32B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer switch class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of contact positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRotary knob, selector switch (no display)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical interlocking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePadlock in OFF position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (front, automatic mode), IP20 (inside enclosure, manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310 x 147 x 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe rotary knob and selector switch give local manual control without a display, which keeps the front panel simpler than the LCD-controller version on the same TA10 frame; choose that LCD variant instead where remote status and alarm detail at the panel matter. This 100 A switch carries utilization category AC-32B rather than the AC-33B used by the lower-current siblings in the same frame, reflecting the higher current duty point at the top of the 32-100 A range. The 100 A rating sits within the 32-100 A TA10 frame shared with the 32 A, 40 A, 50 A, 63 A siblings; pick a higher-current sibling if the connected load draws more than 100 A, since the enclosure and mounting dimensions stay identical across the frame. As a 3-pole switch it transfers the three phase conductors only, relying on a shared neutral between the two sources; the 4P version in the same frame switches the neutral as well.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eTransferPacT automatic transfer switches of this frame are used to change the power source for life-safety and continuity-critical loads such as fire-fighting equipment, smoke extraction fans, sprinkler pumps and emergency lighting in industrial and commercial buildings, data centers, healthcare facilities and transportation infrastructure, mounted inside a power distribution cabinet on DIN rail or plate.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078641897755,"sku":"TA10D3S1004TPE","price":673.2,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ta10d3s1004tpe-transferpact-automatic-transfer-switch.jpg?v=1790904777"},{"product_id":"schneider-electric-ta10d2l0803tpe-transferpact-ats","title":"Schneider Electric TA10D2L0803TPE TransferPacT Active 2P 80 A 230 V LCD Controller Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TA10D2L0803TPE is a 2P TransferPacT Active automatic transfer switch rated for 80 A at 230 V AC, built on the 32-100 A TA10 frame. It switches a load between two AC supply sources through 3 contact positions with mechanical and electrical position indication, and its front-mounted LCD screen displays status and alarm settings for automatic or manual operation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTA10D2L0803TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 800 V, Controller: 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 6 kV, Controller: 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] rated short-circuit making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA (switch-disconnector alone), 75 kA (with upstream protection circuit breaker), 400 V AC at 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kA during 0.1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-32B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer switch class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of contact positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD screen, 4 push-button control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical interlocking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePadlock in OFF position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (front, automatic mode), IP20 (inside enclosure, manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310 x 147 x 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LCD controller displays status and alarm setting locally through its screen and is operated with 4 push-buttons, which gives more configuration and diagnostic detail than the rotary-knob version built on the same TA10 frame; choose that rotary variant instead where only basic manual override is needed. This 80 A switch carries utilization category AC-32B rather than the AC-33B used by the lower-current siblings in the same frame, reflecting the higher current duty point at the top of the 32-100 A range. The 80 A rating sits within the 32-100 A TA10 frame shared with the 32 A, 40 A, 50 A, 63 A siblings; pick a higher-current sibling if the connected load draws more than 80 A, since the enclosure and mounting dimensions stay identical across the frame. Being a 2-pole switch, it is sized for single-phase change-of-source duty rather than 3-phase distribution, where the 3P or 4P versions in the same frame apply.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eTransferPacT automatic transfer switches of this frame are used to change the power source for life-safety and continuity-critical loads such as fire-fighting equipment, smoke extraction fans, sprinkler pumps and emergency lighting in industrial and commercial buildings, data centers, healthcare facilities and transportation infrastructure, mounted inside a power distribution cabinet on DIN rail or plate.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078641930523,"sku":"TA10D2L0803TPE","price":708.4,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ta10d2l0803tpe-transferpact-automatic-transfer-switch.jpg?v=1790904781"},{"product_id":"schneider-electric-ta16d3l1254tpe","title":"Schneider Electric TA16D3L1254TPE TransferPacT 3P 125 A LCD 400 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TA16D3L1254TPE is a 3-pole TransferPacT automatic transfer switch rated 125 A at 400 V AC, built to change the source of supply between two AC networks without interrupting a standby or life-safety load. It carries a lcd screen on the front for local status and control, and it is intended for uninterrupted-duty changeover in industrial, commercial and healthcare installations within the 80-160 A frame.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTA16D3L1254TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 800 V | Controller: 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 8 kV | Controller: 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] rated short-circuit making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kA switch-disconnector alone 400 V AC at 50 Hz | 154 kA with upstream protection circuit breaker 400 V AC at 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA during 0.1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer switch class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of contact positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 (mechanically and electrically indicated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal contacts composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 2 NC, 1 NC + 2 NO, or 2 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 push-buttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate or DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside \/ downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical interlocking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith mechanical interlocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePadlock in OFF position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUninterrupted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (automatic mode), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature, operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature, storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e351 mm x 164 mm x 95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-6-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 3-pole TA16D3L1254TPE switches only the phase conductors, so the neutral stays solidly connected between the two sources; pick this execution where both the normal and the standby supply share a common neutral-to-earth bond. Its LCD controller displays source status, the active contact position and alarms locally and is operated from the front push-buttons, which is useful where staff need to read the changeover state without opening the panel. Within the 80-160 A frame, this 125 A setting shares its enclosure footprint with the other current ratings built on the same frame, so the panel cut-out does not change if a different rating from the same frame is specified instead. The 10 kA during 0.1 s short-time withstand current lets it be installed directly downstream of an upstream breaker sized to that let-through level, without extra current-limiting fuses, and the AC-33B utilization category confirms it for uninterrupted-duty source changeover.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078641996059,"sku":"TA16D3L1254TPE","price":771.65,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ta16d3l1254tpe-transferpact-automatic-transfer-switch.jpg?v=1790904789"},{"product_id":"schneider-electric-ta1ad4l16h4tpe","title":"Schneider Electric TA1AD4L16H4TPE TransferPacT TA1A 4P 1600 A LCD 400 V Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TA1AD4L16H4TPE is a 4-pole TransferPacT automatic transfer switch rated 1600 A at 400 V AC, built to change the source of supply between two AC networks without interrupting a standby or life-safety load. It carries a lcd screen on the front for local status and control, and it is intended for uninterrupted-duty changeover in industrial, commercial and healthcare installations within the TA1A frame (800-1600 A).\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTA1AD4L16H4TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange of product\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct or component type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChange source of supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1600 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 1000 V | Controller: 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 12 kV | Controller: 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] rated short-circuit making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 kA switch-disconnector alone | 154 kA with upstream protection circuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA during 0.5 s | 70 kA during 0.1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer switch class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of contact positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 (mechanically and electrically indicated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal contacts composition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 NO + 2 NC, 1 NC + 2 NO, or 2 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 push-buttons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (upside \/ downside)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrewed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical interlocking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWith mechanical interlocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePadlock in OFF position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated duty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUninterrupted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 front face (automatic mode), IP20 inside enclosure (manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature, operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25…70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient air temperature, storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40…85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e540 mm x 391 mm x 383.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-6-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 4-pole TA1AD4L16H4TPE also switches the neutral along with the three phases, which is the configuration to choose when the two sources are separately earthed (for example two independent TN-S supplies) and the neutral itself must be broken during changeover. Its LCD controller displays source status, the active contact position and alarms locally and is operated from the front push-buttons, which is useful where staff need to read the changeover state without opening the panel. At 1600 A this unit sits within the TA1A frame covering 800-1600 A, the top of the TransferPacT range, and carries the higher 1000 V (switch) insulation voltage and 50 kA during 0.5 s | 70 kA during 0.1 s short-time withstand rating that the smaller 160\/250\/630 A frames do not reach. The 50 kA during 0.5 s | 70 kA during 0.1 s short-time withstand current lets it be installed directly downstream of an upstream breaker sized to that let-through level, without extra current-limiting fuses, and the AC-33B utilization category confirms it for uninterrupted-duty source changeover.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078642028827,"sku":"TA1AD4L16H4TPE","price":7469.55,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ta1ad4l16h4tpe-transferpact-automatic-transfer-switch.jpg?v=1790904788"},{"product_id":"schneider-electric-ta10d4l0324tpe-transferpact-ats","title":"Schneider Electric TA10D4L0324TPE TransferPacT Active 4P 32 A 400 V LCD Controller Automatic Transfer Switch","description":"\u003cp\u003eThe Schneider Electric TA10D4L0324TPE is a 4P TransferPacT Active automatic transfer switch rated for 32 A at 400 V AC, built on the 32-100 A TA10 frame. It switches a load between two AC supply sources through 3 contact positions with mechanical and electrical position indication, and its front-mounted LCD screen displays status and alarm settings for automatic or manual operation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTA10D4L0324TPE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransferPacT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic transfer switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ie] rated operational current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ith] conventional free air thermal current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A at 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ue] rated operational voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Ui] rated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 800 V, Controller: 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Uimp] rated impulse withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch: 6 kV, Controller: 6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icm] rated short-circuit making capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA (switch-disconnector alone), 75 kA (with upstream protection circuit breaker), 400 V AC at 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e[Icw] rated short-time withstand current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kA during 0.1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUtilization category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC-33B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer switch class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of contact positions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLCD screen, 4 push-button control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlate, DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical interlocking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocking options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePadlock in OFF position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection pitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP degree of protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP40 (front, automatic mode), IP20 (inside enclosure, manual mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e310 x 147 x 94 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eCB\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eIEC 60947-6-1\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LCD controller displays status and alarm setting locally through its screen and is operated with 4 push-buttons, which gives more configuration and diagnostic detail than the rotary-knob version built on the same TA10 frame; choose that rotary variant instead where only basic manual override is needed. The 32 A rating sits within the 32-100 A TA10 frame shared with the 40 A, 50 A, 63 A, 80 A siblings; pick a higher-current sibling if the connected load draws more than 32 A, since the enclosure and mounting dimensions stay identical across the frame. The 4-pole version additionally switches the neutral conductor, which matters when the two incoming sources do not share a common, solidly bonded neutral.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eTransferPacT automatic transfer switches of this frame are used to change the power source for life-safety and continuity-critical loads such as fire-fighting equipment, smoke extraction fans, sprinkler pumps and emergency lighting in industrial and commercial buildings, data centers, healthcare facilities and transportation infrastructure, mounted inside a power distribution cabinet on DIN rail or plate.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":54078642094363,"sku":"TA10D4L0324TPE","price":1221.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ta10d4l0324tpe-transferpact-automatic-transfer-switch.jpg?v=1790904789"}],"url":"https:\/\/stoklink.com\/collections\/automatic-transfer-switches.oembed?page=4","provider":"Stoklink","version":"1.0","type":"link"}