{"title":"ATS480","description":"","products":[{"product_id":"schneider-electric-ats480c11y-ats480","title":"ATS480C11Y, ATS480 Series Soft Starter, 55 kW, 110 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS480C11Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480C11Y is an ATS480-series soft starter rated for 110 A (normal duty) and designed for three-phase motor supplies from 208 V to 690 V AC. Depending on supply voltage it covers motors from approximately 30 kW up to 90 kW in-line (values vary with mains voltage and duty); heavy-duty rated current for the unit is 88 A. The ATS480C11Y uses Schneider’s torque control (TCS) algorithm to manage acceleration and deceleration, and includes functions for dynamic braking and DC injection for efficient stopping of high-inertia loads. Built for industrial process and infrastructure applications, this unit is intended where controlled, repeatable industrial motor starting and stopping is required while reducing mechanical stress and limiting inrush current. The product is supplied with a 110…230 V control supply and is designed to integrate with optional communication modules for fieldbus and Ethernet networks. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 110 A (normal duty); 88 A (heavy duty)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Typically 30 kW to 90 kW (depending on supply voltage and connection — see motor power table for 230 V \/ 400 V \/ 500–690 V ranges)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208…690 V AC (three-phase)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Supply:\u003c\/strong\u003e 110…230 V AC\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Torque control (TCS); ramp control plus dynamic braking and DC injection for stopping\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated motor protection features (including functions to manage acceleration\/deceleration, dynamic braking and DC injection)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Supports optional communication modules (PROFIBUS DP, PROFINET, Modbus TCP \/ EtherNet‑IP, CANopen variants)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the maximum supply voltage the ATS480C11Y supports?\u003c\/h4\u003e \u003cp\u003eThe ATS480C11Y supports three‑phase supply voltages from 208 V up to 690 V AC.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat rated current and motor sizes is this model suitable for?\u003c\/h4\u003e \u003cp\u003eThis model is rated 110 A (normal duty) — motor power compatibility depends on voltage (typical range about 30 kW up to 90 kW depending on mains voltage and connection).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS480C11Y provide torque-based starting control?\u003c\/h4\u003e \u003cp\u003eYes. The unit uses Schneider’s torque control (TCS) algorithm and also offers dynamic braking and DC injection for controlled stopping.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan the ATS480C11Y connect to industrial networks?\u003c\/h4\u003e \u003cp\u003eYes. It accepts optional communication modules for PROFIBUS DP, PROFINET, Modbus TCP \/ EtherNet‑IP and CANopen variants.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287073563,"sku":"ATS480C11Y","price":1135.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c11y-ats480-to-690v-ac_14d31808-4bbf-4dcd-b303-76e627356ad3.jpg?v=1777185424"},{"product_id":"schneider-electric-ats480c14y-ats480","title":"ATS480C14Y, ATS480 Series Soft Starter, 75 kW, 140 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS480C14Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480C14Y is a three-phase ATS480 soft starter rated for normal-duty operation at 140 A (at 40 °C) with a heavy‑duty rating of 110 A. It is designed for supply voltages from 208 V to 690 V AC (50–60 Hz), making it suitable across low- and medium-voltage three-phase systems. In practical terms the ATS480C14Y can control motors from about 37 kW at 230 V up to 75 kW at 400 V (normal duty), with higher ratings possible when connected to motor delta terminals as specified by Schneider — supporting a wide range of industrial motor sizes used on pumps, conveyors, fans and compressors. This model features Schneider’s torque-control soft-start algorithm and integrated motor overload protection, helping reduce mechanical stress and limit inrush current without an internal bypass contactor. The ATS480C14Y accepts optional communication modules (Modbus, Profibus, CANopen, PROFINET, etc.) to integrate into plant automation, and its IP00 enclosure is intended for panel-mounted installations where space and thermal management are considered. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 140 A (normal duty, at 40 °C); 110 A (heavy duty).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Examples (normal duty): 37 kW @ 230 V; 75 kW @ 400 V. (See manufacturer table for other voltages \/ delta wiring ratings.)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208–690 V AC, 50–60 Hz.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Torque control (soft-start voltage ramp with torque algorithm).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e No (internal bypass not provided).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated motor overload protection.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Optional communication modules available (Modbus TCP\/EtherNet‑IP, Profibus DP, CANopen, PROFINET) — module-based, not built-in.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP00 (panel-mounted installation required).\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the maximum rated current for the ATS480C14Y?\u003c\/h4\u003e \u003cp\u003eThe ATS480C14Y is rated 140 A for normal duty (at 40 °C) and 110 A for heavy-duty service.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich supply voltages does the ATS480C14Y support?\u003c\/h4\u003e \u003cp\u003eIt supports three-phase AC supplies from 208 V up to 690 V at 50–60 Hz.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes this model include an internal bypass contactor?\u003c\/h4\u003e \u003cp\u003eNo — the ATS480C14Y does not include an internal bypass; use an external bypass or wiring per application requirements.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan the ATS480C14Y communicate with PLCs or a plant network?\u003c\/h4\u003e \u003cp\u003eYes — communication is available via optional plug-in modules (for Modbus TCP\/EtherNet‑IP, Profibus DP, CANopen, PROFINET, etc.).\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287171867,"sku":"ATS480C14Y","price":2803.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c14y-ats480-to-690v-ac_88dcdeee-6c5c-405b-b4f7-f5d18341cbd3.jpg?v=1777185428"},{"product_id":"schneider-electric-ats480c17y-ats480","title":"ATS480C17Y, ATS480 Series Soft Starter, 90 kW, 170 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: Schneider Electric ATS480C17Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480C17Y is an ATS480-series soft starter rated for 170 A (normal duty) with a heavy-duty rating of 140 A at 40 °C. It is designed for three-phase supply voltages from 208 V to 690 V and covers a wide motor power range depending on connection and mains voltage — for example, typical inline ratings include 45 kW at 230 V and 90 kW at 400 V (normal duty), while inside-delta connection and higher voltage points extend the compatible motor size up to the higher kilowatt classes listed for the ATS480 family. The unit uses a torque-control starting algorithm (TCS) to manage acceleration and deceleration, provides embedded motor overload protection and diagnostic routines, and supports stopping methods including DC injection and dynamic braking where applicable. This model is supplied in an IP00 enclosure (open-style) and can be fitted with optional communication modules (PROFINET, Modbus TCP \/ EtherNet‑IP, Profibus DP, CANopen) to integrate with automation systems. The ATS480C17Y is suitable for process and infrastructure applications such as pumps, fans, compressors and conveyors where controlled starts, reduced mechanical stress and improved availability are required. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 170 A (normal duty); 140 A (heavy duty) at 40 °C\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Examples — 45 kW at 230 V (inline, normal duty); 90 kW at 400 V (inline, normal duty); higher ratings available when inside-delta or at higher supply voltages (see datasheet for full table)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208…690 V AC, 50\/60 Hz\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Torque control (TCS) \/ voltage ramp functions and configurable start\/stop profiles\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e No (external bypass \/ external contactor arrangements commonly used)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated motor overload protection and embedded diagnostic\/test routines\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Optional communication modules available — PROFINET, Modbus TCP \/ EtherNet‑IP, Profibus DP, CANopen\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP00 (open-panel mounting)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the maximum current rating for the ATS480C17Y?\u003c\/h4\u003e \u003cp\u003eThe ATS480C17Y is rated 170 A in normal duty and 140 A in heavy duty at 40 °C.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich supply voltages does the ATS480C17Y support?\u003c\/h4\u003e \u003cp\u003eIt supports three-phase supply voltages from 208 V up to 690 V AC at 50\/60 Hz.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan the ATS480C17Y protect the motor from overload?\u003c\/h4\u003e \u003cp\u003eYes — the model includes integrated motor overload protection and embedded diagnostic routines for commissioning and fault detection.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS480C17Y include an internal bypass contactor?\u003c\/h4\u003e \u003cp\u003eNo. The ATS480C17Y is supplied without an internal bypass; external bypass\/contactors are used where required.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287237403,"sku":"ATS480C17Y","price":3441.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c17y-ats480-to-690v-ac_18696890-e87a-4f2b-bf14-fdc819426276.jpg?v=1777185432"},{"product_id":"schneider-electric-ats480c21y-ats480","title":"ATS480C21Y, ATS480 Series Soft Starter, 110 kW, 210 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: Schneider Electric ATS480C21Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480C21Y is an ATS480-series soft starter rated for 210 A (normal duty) designed for three-phase supply voltages from 208 V to 690 V. Depending on mains voltage and connection method (inline or inside-delta), the ATS480C21Y supports motor power from approximately 55 kW up to 200 kW (examples: 55 kW at 230 V inline normal duty; 110 kW at 400 V inline normal duty; up to 200 kW at 690 V inline normal duty). The unit implements Schneider’s torque control algorithm for managed acceleration and deceleration and includes integrated motor protection functions (thermal overload, phase loss, phase imbalance, locked-rotor and excessive starting time). The ATS480C21Y is intended for process and infrastructure applications — pumps, fans, compressors, conveyors and other industrial machinery — where controlled starts, reduced mechanical stress and clear diagnostic information improve uptime. Communication option cards (Modbus TCP \/ EtherNet‑IP, PROFINET, Profibus DP V1, CANopen variants) are available to integrate the starter into automation networks. The starter is supplied without an internal bypass (external bypass arrangements are used where required) and is delivered in an IP00 mounting format for panel installation. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 210 A (normal duty); 170 A (heavy duty at 40 °C).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Approx. 55 kW to 200 kW depending on supply voltage and connection (examples: 55 kW @230 V inline normal duty; 110 kW @400 V inline normal duty; up to 200 kW @690 V inline normal duty).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208…690 V AC, 3-phase, 50\/60 Hz.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Torque control (TCS) with managed voltage ramp for start\/stop.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e No (external bypass arrangements where required).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated thermal protection, current overload, phase loss\/phase failure detection, motor phase loss, locked-rotor protection, excessive starting time, underload detection.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Optional communication modules available: Modbus TCP \/ EtherNet‑IP, PROFINET, Profibus DP V1, CANopen (various form factors).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP00 (panel-mounted starter; suitable for enclosure integration).\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the maximum rated current for the ATS480C21Y?\u003c\/h4\u003e \u003cp\u003eThe ATS480C21Y is rated 210 A in normal duty and 170 A in heavy-duty operation at 40 °C.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich supply voltages and motor sizes can I use with this model?\u003c\/h4\u003e \u003cp\u003eIt supports 208–690 V AC (3-phase). Motor compatibility ranges roughly from 55 kW up to 200 kW depending on voltage and whether the starter is wired inline or inside the motor delta.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS480C21Y include an internal bypass contactor?\u003c\/h4\u003e \u003cp\u003eNo — the ATS480C21Y is supplied without an internal bypass; external bypass solutions are used when continuous run bypass is required.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan the ATS480C21Y be networked into an industrial control system?\u003c\/h4\u003e \u003cp\u003eYes. Communication option cards are available (Modbus TCP \/ EtherNet‑IP, PROFINET, Profibus DP V1, CANopen variants) to integrate the starter into automation networks.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287302939,"sku":"ATS480C21Y","price":3866.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c21y-ats480-to-690v-ac_48043e01-59c3-4ce1-b9f7-d2e295c4e7ae.jpg?v=1777185435"},{"product_id":"schneider-electric-ats480c25y-ats480","title":"ATS480C25Y, ATS480 Series Soft Starter, 132 kW, 250 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS480C25Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480C25Y is an ATS480-series motor soft starter rated for 250 A (normal duty) with a heavy-duty rating of 210 A at 40 °C. It is designed for three-phase supply voltages from 208 to 690 V AC and supports motor power ranges up to approximately 132 kW (400 V, inline) in normal duty conditions (with lower heavy-duty values specified). The ATS480C25Y features torque-based control for smoother torque ramping during industrial motor starting and includes built-in motor overload protection. This model is suitable for demanding process and infrastructure applications — pumps, large fans, compressors and conveyors — where reduced mechanical stress and inrush current limitation improve reliability and reduce maintenance. The unit is delivered in an IP00 enclosure and supports optional communication option cards (Modbus TCP\/EtherNet‑IP, PROFINET, Profibus DP, CANopen) when fitted, enabling integration into automation networks. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 250 A (normal duty); 210 A (heavy duty at 40 °C)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Up to 132 kW at 400 V (normal duty); lower heavy-duty kW ratings apply (e.g., 110 kW at 400 V heavy duty)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208…690 V AC (50\/60 Hz)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Torque control (soft starting with torque ramping)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e No (internal bypass not provided)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated motor overload protection\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Optional communication modules available (Modbus TCP\/EtherNet‑IP, PROFINET, Profibus DP, CANopen)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP00\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the maximum continuous current rating of the ATS480C25Y?\u003c\/h4\u003e \u003cp\u003eThe ATS480C25Y is rated 250 A for normal duty operation and 210 A for heavy-duty operation at 40 °C.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich supply voltages does the ATS480C25Y support?\u003c\/h4\u003e \u003cp\u003eIt supports three-phase supply voltages from 208 V up to 690 V AC (50\/60 Hz).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan the ATS480C25Y replace a direct-on-line starter for large pumps and conveyors?\u003c\/h4\u003e \u003cp\u003eYes — with torque control and inrush-current limitation, the ATS480C25Y is suitable for large pumps, fans, compressors and conveyors to reduce mechanical stress and electrical peak currents compared with direct-on-line starting.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS480C25Y include an internal bypass contactor?\u003c\/h4\u003e \u003cp\u003eNo. The ATS480C25Y does not include an internal bypass; an external bypass or contactor arrangement is required if continuous bypass is needed.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287401243,"sku":"ATS480C25Y","price":4151.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c25y-ats480-to-690v-ac_a660d34b-21d9-4298-b9d4-599cdcf97614.jpg?v=1777185440"},{"product_id":"schneider-electric-ats480c32y-ats480","title":"ATS480C32Y, ATS480 Series Soft Starter, 160 kW, 320 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: Schneider Electric ATS480C32Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480C32Y is an ATS480-series soft starter rated for 320 A (normal duty) and designed for 3-phase supplies from 208 to 690 V AC at 50\/60 Hz. It uses Schneider’s torque control algorithm (TCS) to manage acceleration and deceleration, reduce mechanical stress and limit inrush current on heavy industrial motors. Depending on supply voltage and wiring (line or delta), the ATS480C32Y supports a broad motor power range — for example, typical normal-duty ratings include up to 160 kW at 400 V and up to 315 kW at 690 V — with lower heavy-duty values specified for continuous or severe applications. The unit is supplied with IP00 degree (open frame) and is intended for process and infrastructure applications such as pumps, fans, compressors and conveyors. The model can be used with external bypass arrangements and supports optional communication modules (Modbus TCP\/EtherNet‑IP, Profibus, CANopen variants) and integrated motor protection and diagnostic functions as specified by Schneider Electric. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e Normal duty 320 A; Heavy duty 250 A.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Examples by supply (normal duty): up to 90 kW at 230 V; 160 kW at 400 V; 220 kW at 500–525 V; 250 kW at 660 V; 315 kW at 690 V. (Heavy duty values are lower as specified by Schneider Electric.)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208…690 V AC, 50\/60 Hz.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Torque Control System (TCS) \/ voltage ramp and torque-based start\/stop control.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e External bypass configuration supported (external bypass arrangement commonly used with this SKU).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated motor protection and diagnostic functions (as supplied by Schneider Electric for ATS480 range).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Supports optional communication modules (e.g., Modbus TCP\/EtherNet‑IP, Profibus DP V1, CANopen) via add-on cards.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP00 (open-frame unit).\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat supply voltages does the ATS480C32Y support?\u003c\/h4\u003e \u003cp\u003eThe ATS480C32Y supports three-phase supplies from 208 V up to 690 V AC at 50\/60 Hz.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the rated operational current and how does heavy duty differ?\u003c\/h4\u003e \u003cp\u003eRated operational current is 320 A in normal duty. Heavy-duty continuous rating is specified as 250 A (at 40 °C) by Schneider Electric.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich motor sizes can this soft starter handle?\u003c\/h4\u003e \u003cp\u003eMotor compatibility varies by voltage and wiring; examples (normal duty): up to ~160 kW at 400 V and up to 315 kW at 690 V. Use Schneider’s sizing tables for exact motor-match details.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan I add fieldbus or Ethernet communications to the ATS480C32Y?\u003c\/h4\u003e \u003cp\u003eYes — the ATS480 family accepts optional communication modules (Modbus TCP\/EtherNet‑IP, Profibus DP, CANopen variants) as specified by Schneider Electric.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287499547,"sku":"ATS480C32Y","price":5211.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c32y-ats480-to-690v-ac_85872efb-5c97-45f5-a044-aef9fd820d59.jpg?v=1777185443"},{"product_id":"schneider-electric-ats480c41y-ats480","title":"ATS480C41Y, ATS480 Series Soft Starter, 220 kW, 410 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: Schneider Electric ATS480C41Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480C41Y is a three-phase ATS480 soft starter rated for 410 A (normal duty) with a wide supply voltage range of 208–690 V AC and 50\/60 Hz operation. It supports torque (true torque) control and is suitable for large motors used in heavy industrial applications. Typical motor compatibility spans from about 110 kW at 230 V up to 400 kW at 690 V (normal duty values), with heavy-duty current rating published as 320 A at 40 °C. The unit accepts a control supply of 110–250 V AC and is designed for process and infrastructure applications such as large pumps, fans, compressors and conveyors where reduced mechanical stress and controlled current ramp-up are required. This model also supports multiple communication option cards (Profibus DP, PROFINET, Modbus TCP\/EtherNet‑IP, CANopen variants) for integration into automation systems and provides integrated motor overload protection and monitoring functions as documented in manufacturer and authorised distributor technical data. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 410 A (normal duty)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e examples — 110 kW at 230 V to 400 kW at 690 V (normal duty); heavy‑duty ratings lower (e.g., 320 A heavy duty).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208…690 V AC, 50\/60 Hz\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Torque control (true torque)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated motor overload protection and motor monitoring (as specified in product documentation)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Optional communication modules — Profibus DP, PROFINET, Modbus TCP \/ EtherNet‑IP, CANopen (option cards)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Supply Voltage:\u003c\/strong\u003e 110…250 V AC (control circuit)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP00 (unit chassis)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the rated operational current for the ATS480C41Y?\u003c\/h4\u003e \u003cp\u003eThe ATS480C41Y is rated at 410 A (normal duty). A heavy‑duty current rating of 320 A at 40 °C is also published by distributors.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich supply voltages and motor sizes does the ATS480C41Y support?\u003c\/h4\u003e \u003cp\u003eIt supports 208–690 V AC (50\/60 Hz). Documented motor power examples range from ~110 kW at 230 V up to 400 kW at 690 V in normal duty conditions.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan the ATS480C41Y connect to industrial networks?\u003c\/h4\u003e \u003cp\u003eYes. Communication option cards are available for Profibus DP, PROFINET, Modbus TCP\/EtherNet‑IP and CANopen (module options must be fitted as required).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS480C41Y provide motor protection and monitoring?\u003c\/h4\u003e \u003cp\u003eYes. Manufacturer and authorised distributor documentation list integrated motor overload protection and motor monitoring features in the ATS480C41Y.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287630619,"sku":"ATS480C41Y","price":6305.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c41y-ats480-to-690v-ac_aa756bab-12d8-4f3a-8ce4-a66317452143.jpg?v=1777185448"},{"product_id":"schneider-electric-ats480c48y-ats480","title":"ATS480C48Y, ATS480 Series Soft Starter, 250 kW, 480 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS480C48Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480C48Y is a three‑phase Altivar soft starter rated for 480 A (Ie) intended for industrial motor starting in the 208–690 V supply range. Verified manufacturer data show this model supports typical motor power up to approximately 250 kW at 400 V (inline) and up to 355 kW at 660 V (delta\/inside‑delta ratings vary by connection and duty). The unit provides torque control for smooth ramping, built‑in motor overload protection, and a control supply voltage option of 110–230 V AC. ATS480C48Y is suitable for heavy process and infrastructure applications—pumps, fans, compressors and conveyors—where controlled starting, reduced mechanical stress and repeatable starts are required. The model does not include an internal bypass and is supplied in an IP00 enclosure; communication options and accessories (Modbus, EtherNet\/IP, PROFINET and related modules) are available for integration into automation systems. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 480 A (normal duty at 40 °C).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e up to ~250 kW at 400 V (inline rating); up to ~355 kW at 660 V (model ratings vary by connection and duty).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208–690 V AC, 50\/60 Hz.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Supply Voltage:\u003c\/strong\u003e 110–230 V AC.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Torque control (soft starting with torque regulation).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e No (external bypass required if bypass function is needed).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated motor overload protection (manufacturer‑verified).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Support for common modules including Modbus, EtherNet\/IP, PROFINET (module-dependent).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP00 (unit body); field\/ panel or accessory options available per installation requirements.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the rated current of the ATS480C48Y?\u003c\/h4\u003e \u003cp\u003eThe ATS480C48Y is rated for 480 A (rated operational current, normal duty at 40 °C).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich supply voltages does this soft starter support?\u003c\/h4\u003e \u003cp\u003eIt supports line supply voltages from 208 V to 690 V AC at 50\/60 Hz.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS480C48Y include an internal bypass contactor?\u003c\/h4\u003e \u003cp\u003eNo — the ATS480C48Y is supplied without an internal bypass; an external bypass arrangement is required if bypass switching is needed.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat motor sizes can I control with this model?\u003c\/h4\u003e \u003cp\u003eVerified manufacturer ratings indicate motor power up to approximately 250 kW at 400 V (inline) and up to 355 kW at higher voltages depending on connection and duty; always check the nameplate and application duty when selecting.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287696155,"sku":"ATS480C48Y","price":7442.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c48y-ats480-to-690v-ac_9867197c-53f7-4f48-a709-b8e0de3114ff.jpg?v=1777185452"},{"product_id":"schneider-electric-ats480c59y-ats480","title":"ATS480C59Y, ATS480 Series Soft Starter, 315 kW, 590 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: Schneider Electric ATS480C59Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480C59Y is an Altistart 480 soft starter rated for heavy industrial motor starting where high current and flexible control are required. It is specified for a normal-duty rated operational current of 590 A (with a heavy‑duty rating of 480 A at 40 °C) and supports a wide supply voltage class from 208 V up to 690 V AC (–15% \/ +10%), 50\/60 Hz. Typical motor size compatibility spans from medium-large motors up to approximately 315 kW at 400 V (normal duty) and up to 560 kW at 690 V (normal duty), with lower heavy‑duty ratings (for example ~250 kW heavy duty at 400 V). The ATS480C59Y provides torque-capable control and voltage ramp start\/stop strategies to reduce mechanical stress and limit inrush current, making it suitable for pumps, fans, compressors, conveyors and process-driven installations in infrastructure and industrial plants. The unit is designed for integration into control systems via optional communication modules (Profibus DP, PROFINET, Modbus TCP\/EtherNet‑IP, CANopen) and includes built-in motor overload protection (thermal class 10E). The product is supplied with a control power range of 110…250 V AC and is delivered in an IP00 main enclosure configuration for panel mounting; an external bypass arrangement is used for line continuity after start. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 590 A (normal duty); 480 A (heavy duty, at 40 °C)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Examples: 160 kW @ 230 V (normal duty); 315 kW @ 400 V (normal duty); up to 560 kW @ 690 V (normal duty). (Heavy-duty ratings are lower—for example ~250 kW @ 400 V heavy duty)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208…690 V AC (–15% \/ +10%), 50\/60 Hz\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Torque control and voltage‑ramp soft starting\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e External bypass (requires external bypass for full-line conduction)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated motor overload protection (thermal class 10E)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Optional communication modules available (Profibus DP, PROFINET, Modbus TCP \/ EtherNet‑IP, CANopen)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP00 (panel-mounted unit)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the maximum continuous current rating of the ATS480C59Y?\u003c\/h4\u003e \u003cp\u003eThe ATS480C59Y is rated 590 A in normal duty and 480 A in heavy duty (ratings quoted at 40 °C). \u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich supply voltages does this Schneider ATS480 soft starter support?\u003c\/h4\u003e \u003cp\u003eIt supports a wide AC supply range from 208 V to 690 V (–15% \/ +10%), 50\/60 Hz.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat motor power can I expect at 400 V?\u003c\/h4\u003e \u003cp\u003eAt 400 V the ATS480C59Y is specified around 315 kW in normal duty and about 250 kW in heavy duty (values depend on application and duty cycle).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS480C59Y include communication options for PLC integration?\u003c\/h4\u003e \u003cp\u003eYes — the model supports optional communication modules such as Profibus DP, PROFINET, Modbus TCP\/EtherNet‑IP and CANopen for system integration.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287892763,"sku":"ATS480C59Y","price":8647.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c59y-ats480-to-690v-ac_c956528b-e6f4-4db4-b8c1-0d98badc37f7.jpg?v=1777185456"},{"product_id":"schneider-electric-ats480c66y-ats480","title":"ATS480C66Y, ATS480 Series Soft Starter, 355 kW, 660 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS480C66Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480C66Y is a heavy‑duty Altivar ATS480 soft starter with a rated operational current of 660 A (normal duty) and 590 A (heavy duty at 40 °C). It accepts a wide supply voltage range of 208–690 V AC (50\/60 Hz) and is suitable for large asynchronous motors from approximately 160 kW up to 630 kW depending on the supply voltage and duty (examples: 355 kW @ 400 V normal duty; 315 kW @ 400 V heavy duty; 630 kW @ 660 V normal duty). Designed for process and infrastructure applications, the ATS480C66Y provides torque control (TCS) for managed acceleration\/deceleration and includes dynamic braking and DC injection functions for stopping high‑inertia loads. The unit is intended for in‑line or delta connection to reduce operational current and is built for industrial commissioning with embedded test routines and modular communication options for fieldbus and Ethernet networks. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e Normal duty: 660 A; Heavy duty: 590 A (at 40 °C)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Examples by voltage — 160 kW @ 230 V (heavy duty); 355 kW @ 400 V (normal duty) \/ 315 kW @ 400 V (heavy duty); 400 kW @ 440 V (normal duty); 630 kW @ 660 V (normal duty).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208…690 V AC, 50\/60 Hz\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Torque control (TCS) with adjustable current limiting; voltage ramp control modes available in ATS480 family (TCS verified for this model).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e (Not confirmed for this exact model — omitted)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Torque control, dynamic braking, DC injection (stop), embedded test routines for commissioning.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Compatible option cards: Profibus DP, Modbus TCP \/ EtherNet\/IP, CANopen (various form factors), PROFINET.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP00 (unit rating as supplied).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Supply Voltage (Uc):\u003c\/strong\u003e 110–230 V AC (control \/ supply).\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the maximum rated current of the ATS480C66Y?\u003c\/h4\u003e \u003cp\u003eThe ATS480C66Y is rated 660 A in normal duty and 590 A in heavy duty (at 40 °C).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich supply voltages and motor sizes are supported by this model?\u003c\/h4\u003e \u003cp\u003eIt supports 208–690 V AC (50\/60 Hz). Motor power examples: 355 kW @ 400 V (normal duty) and up to 630 kW at higher line voltages (normal duty), with specific ratings varying by supply voltage and duty class.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan the ATS480C66Y be integrated on an industrial network?\u003c\/h4\u003e \u003cp\u003eYes. The model supports optional communication modules — Profibus DP, Modbus TCP \/ EtherNet\/IP, CANopen and PROFINET options are available for integration.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eIs the ATS480C66Y suitable for high‑inertia or stopping applications?\u003c\/h4\u003e \u003cp\u003eYes. The unit includes torque control and verified functions such as dynamic braking and DC injection to stop high‑inertia loads safely.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230287958299,"sku":"ATS480C66Y","price":9850.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c66y-ats480-to-690v-ac_a8ff7b2f-19ce-4198-be0d-ecb964019a09.jpg?v=1777185460"},{"product_id":"schneider-electric-ats480c79y-ats480","title":"ATS480C79Y, ATS480 Series Soft Starter, 400 kW, 790 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS480C79Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480C79Y is a heavy‑duty Altivar Soft Starter configured for large industrial motors. It is rated for 790 A (normal duty) with a heavy‑duty rating of 660 A at 40 °C, and supports a wide supply voltage range from 208 V to 690 V AC (50–60 Hz), making it compatible with common line and delta motor connections across international voltage classes. Typical motor power compatibility ranges up to several hundred kilowatts depending on system voltage (examples from manufacturer data: 400 kW at 400 V normal duty, up to 710 kW at 690 V normal duty, with corresponding heavy‑duty values per Schneider documentation). The ATS480C79Y provides torque (true torque) control for precise ramping and reduced mechanical stress, integrated motor protection (overload, phase loss, locked rotor, excessive starting time, underload and thermal protection), and multiple programmable inputs\/outputs including three relay outputs and one analogue output. Control supply for the unit is 110–230 V AC. Communications and integration are supported via an RJ45 physical connector for Modbus\/RS‑485 and a range of optional communication modules (Modbus TCP\/EtherNet‑IP, PROFIBUS DP, PROFINET, CANopen options available as factory\/field options). With IP00 enclosure rating and a design intended for process and infrastructure applications, this model is targeted at engineers and procurement teams specifying soft starters for pumps, compressors, conveyors and other large rotating machinery where high inrush limitation and advanced motor protection are required. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 790 A (normal duty); 660 A (heavy duty at 40 °C).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Manufacturer-listed examples up to 710 kW (690 V normal duty); 400 kW (400 V normal duty); 220 kW (230 V normal duty). Exact motor power depends on connection and duty class.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208–690 V AC, 50–60 Hz.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e True torque control (torque regulation \/ voltage ramp functions supported).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e External bypass (unit intended for external bypass arrangements as specified for this configuration).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated thermal protection, current overload, phase loss detection (motor and line), locked rotor, excessive starting time, underload protection.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e RJ45 serial interface (Modbus RTU over RS‑485); optional communication modules available (Modbus TCP\/EtherNet‑IP, PROFIBUS DP, PROFINET, CANopen) as configured.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP00 (open panel mount).\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the rated current for the ATS480C79Y?\u003c\/h4\u003e \u003cp\u003eThe ATS480C79Y is rated 790 A in normal duty; the heavy‑duty continuous rating is 660 A at 40 °C, per Schneider Electric specifications.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich supply voltages does this soft starter support?\u003c\/h4\u003e \u003cp\u003eThis model supports a wide supply range of 208–690 V AC at 50–60 Hz, allowing use across common industrial voltage classes.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan the ATS480C79Y protect the motor from overload and phase loss?\u003c\/h4\u003e \u003cp\u003eYes — the unit includes integrated motor protection functions such as thermal protection, current overload, phase loss (motor and line), locked‑rotor and excessive start time detection.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat communications are available for integration with PLCs and SCADA?\u003c\/h4\u003e \u003cp\u003eThe starter provides an RJ45 serial interface for Modbus RTU\/RS‑485; Schneider offers optional communication modules (Modbus TCP\/EtherNet‑IP, PROFIBUS DP, PROFINET, CANopen) for networked integration.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230288056603,"sku":"ATS480C79Y","price":12869.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480c79y-ats480-to-690v-ac_35e7c8f1-1869-4223-900f-41a910c2a00a.jpg?v=1777185463"},{"product_id":"schneider-electric-ats480d17y-ats480","title":"ATS480D17Y, ATS480 Series Soft Starter, 7,5 kW, 17 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS480D17Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480D17Y is a three-phase Altivar ATS480 soft starter with a rated operational current of 17 A (normal duty) for motor supplies between 208 and 690 VAC. It supports torque control for controlled acceleration and deceleration and includes integrated motor overload protection. Depending on supply voltage and connection method (line or in-delta), the ATS480D17Y covers a practical motor power range from 4.0 kW (230 V, inline) up to 15.0 kW (690 V, inline) and can be used in delta wiring to extend motor power capacity (for example up to 15.0 kW at 400 V in delta). The unit is IP20 rated and intended for process and infrastructure applications such as pumps, fans, compressors and conveyors where reduced mechanical stress, managed inrush, and accurate stopping are required. This model is offered without an internal bypass and provides digital connectivity options used during commissioning and monitoring. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 17 A (normal duty); 12 A (heavy duty at 40 °C)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Inline: 4.0 kW (230 V) up to 15.0 kW (690 V); Delta configurations increase inline-equivalent ratings (examples: 7.5 kW at 400 V inline; 15.0 kW at 400 V in delta).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208…690 V AC (50–60 Hz)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Torque control (TCS) with managed voltage ramp for start\/stop\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e No (internal bypass not included)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated motor overload protection (thermal class and monitoring)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Modbus serial (RJ45) reported for configuration\/monitoring\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the maximum supply voltage the ATS480D17Y supports?\u003c\/h4\u003e \u003cp\u003eThe ATS480D17Y supports a motor supply voltage range from 208 V up to 690 V AC (50–60 Hz).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat motor sizes can this soft starter handle?\u003c\/h4\u003e \u003cp\u003eDepending on voltage and connection: inline ratings include 4.0 kW at 230 V and up to 15.0 kW at 690 V; delta wiring can increase the effective motor power capability (examples available in the product datasheet).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS480D17Y include an internal bypass contactor?\u003c\/h4\u003e \u003cp\u003eNo — this model is supplied without an internal bypass.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich control and protection features are built in?\u003c\/h4\u003e \u003cp\u003eThe unit provides torque control (TCS) for soft starting\/stopping and includes integrated motor overload protection and monitoring functions.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230288122139,"sku":"ATS480D17Y","price":990.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480d17y-ats480-to-690v-ac_dc7fb6ef-8ea1-4ccd-8799-b877961df24a.jpg?v=1777185467"},{"product_id":"schneider-electric-ats480d22y-ats480","title":"ATS480D22Y, ATS480 Series Soft Starter, 11 kW, 22 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: Schneider Electric ATS480D22Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480D22Y is an ATS480 series soft starter rated for 22 A (normal duty) and designed for three-phase asynchronous motors supplied from 208 V up to 690 V AC. Depending on mains voltage and duty class this unit covers typical motor ratings from about 5.5 kW up to 18.5 kW (examples: 11 kW at 400 V normal duty; 18.5 kW at 690 V normal duty). The starter provides true torque control and integrated motor protection (thermal\/overload, phase-loss and locked-rotor detection) and can be used in-line or connected to motor delta terminals where applicable. Control supply for the unit is 110–230 V AC and communications include a Modbus serial (RS‑485) RJ45 port; optional fieldbus cards (PROFINET, Modbus TCP\/EtherNet‑IP, PROFIBUS DP, CANopen variants) are supported. The ATS480D22Y is specified with IP20 protection and supports both normal and heavy duty ratings (heavy duty rated operational current 17 A at 40 °C). Typical application areas are pumps, fans, compressors and conveyor drives where reduced mechanical stress, current limiting and diagnostics are required. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 22 A (normal duty)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Up to 18.5 kW (690 V, normal duty); examples: 11 kW @ 400 V (normal duty), 5.5 kW @ 230 V (normal duty)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208…690 V AC (three-phase)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e True torque control (soft start \/ voltage ramp with torque algorithm)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e External bypass (device designed for external bypass configuration)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated motor overload\/thermal protection, phase-loss detection, locked-rotor and excessive starting time protection\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Modbus serial (RS‑485, RJ45); optional communication modules available (PROFINET, Modbus TCP\/EtherNet‑IP, PROFIBUS DP, CANopen variants)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Supply Voltage:\u003c\/strong\u003e 110…230 V AC\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eHeavy Duty Rated Current:\u003c\/strong\u003e 17 A (heavy duty, 40 °C)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat supply voltages does the ATS480D22Y support?\u003c\/h4\u003e \u003cp\u003eThe ATS480D22Y supports three-phase supply voltages from 208 V up to 690 V AC (50–60 Hz range).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the rated operational current and heavy‑duty current for this model?\u003c\/h4\u003e \u003cp\u003eRated operational current is 22 A (normal duty). The heavy‑duty rated current is specified as 17 A at 40 °C.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich motor sizes can I start with the ATS480D22Y?\u003c\/h4\u003e \u003cp\u003eDepending on mains voltage and duty: typical motor compatibility ranges from around 5.5 kW (230 V) up to 18.5 kW (690 V) in normal duty; refer to the motor-power table for exact values at each voltage.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS480D22Y offer communications and fieldbus options?\u003c\/h4\u003e \u003cp\u003eYes — it includes a Modbus serial (RS‑485, RJ45) port and supports optional communication modules such as PROFINET, Modbus TCP\/EtherNet‑IP, PROFIBUS DP and CANopen variants.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230288220443,"sku":"ATS480D22Y","price":1066.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480d22y-ats480-to-690v-ac_0fa16069-b424-40b4-888a-699299661e7b.jpg?v=1777185472"},{"product_id":"schneider-electric-ats480d32y-ats480","title":"ATS480D32Y, ATS480 Series Soft Starter, 15 kW, 32 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS480D32Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480D32Y is a compact three-phase soft starter rated for 32 A (normal duty) and designed for motor supply voltages from 208 V up to 690 V AC (50–60 Hz). In inline configuration it covers typical motor sizes from 7.5 kW (at 230 V) up to 15 kW (at 400 V) in normal duty; in heavy-duty applications the permissible motor power is reduced (for example 11 kW at 400 V heavy duty). The unit provides true torque control, integrated motor overload protection and an IP20 enclosure. ATS480D32Y is intended for process and infrastructure applications such as pumps, fans, conveyors and compressors where smooth industrial motor starting and controlled stopping reduce mechanical stress and inrush currents. Notable verified characteristics for this SKU include a 32 A rated operational current (normal duty), compatibility with ATS480\/ATS48 accessory and communication modules, and no internal bypass in the base configuration. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 32 A (normal duty, at ≤ 40 °C)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Inline: 7.5 kW at 230 V to 15 kW at 400 V (normal duty); reduced values for heavy duty (e.g., 11 kW at 400 V heavy duty)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208…690 V AC, 50–60 Hz\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e True torque control (soft start \/ soft stop)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e No (base unit)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated motor overload protection (thermal class and protection functions as per ATS480 family)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Compatible with ATS480 communication option modules (Modbus, Ethernet\/IP, ProfiNet, CANopen options available via modules)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the rated current of the ATS480D32Y?\u003c\/h4\u003e \u003cp\u003eThe ATS480D32Y is rated for 32 A (normal duty) at ambient temperature up to 40 °C.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich supply voltages does this model support?\u003c\/h4\u003e \u003cp\u003eIt supports a wide supply range from 208 V to 690 V AC at 50–60 Hz.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS480D32Y include an internal bypass contactor?\u003c\/h4\u003e \u003cp\u003eNo — the base ATS480D32Y is supplied without an internal bypass.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan I use communication protocols with this unit?\u003c\/h4\u003e \u003cp\u003eYes — ATS480D32Y is compatible with ATS480 option communication modules (Modbus, Ethernet\/IP, Profinet, CANopen available via sold-separately modules).\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230288285979,"sku":"ATS480D32Y","price":1142.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480d32y-ats480-to-690v-ac_642b4b79-ce08-4183-8b82-e91459121942.jpg?v=1777185475"},{"product_id":"schneider-electric-ats480d38y-ats480","title":"ATS480D38Y, ATS480 Series Soft Starter, 18,5 kW, 38 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS480D38Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480D38Y is a 3‑phase Altivar soft starter rated for 38 A (Ie) and designed for supply voltages from 208 V up to 690 V AC. It supports inline and delta connections and is sized to start motors from roughly 9 kW up to 30 kW depending on supply voltage and connection type (for example: inline ~9 kW at 230 V and ~18.5 kW at 400 V; in delta up to 30 kW at 400 V). The ATS480D38Y uses Schneider’s torque control (TCS) algorithm for controlled acceleration and deceleration, includes integrated motor overload protection, and is built to IEC standards with an IP20 enclosure. Typical applications are pumps, fans, compressors and conveyors where reduced mechanical stress, controlled stopping (including DC injection and dynamic braking capability of the series), and reliable motor protection are required. This model does not include an internal bypass and is intended for projects requiring a compact, digitally-ready soft starter with modular communication options and reinforced industrial certifications. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 38 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Inline: ~9 kW (230 V) to ~18.5 kW (400 V); Delta: up to 30 kW (400 V) (values depend on mains voltage and connection)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208 V – 690 V AC\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Torque control (TCS) \/ voltage ramp for start and stop\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e No\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated motor overload protection\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e RJ45 port (supports modular communication options available for ATS480 series)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat supply voltages does the ATS480D38Y support?\u003c\/h4\u003e \u003cp\u003eThe ATS480D38Y supports three‑phase supply voltages from 208 V up to 690 V AC.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat motor sizes can this soft starter handle?\u003c\/h4\u003e \u003cp\u003eMotor compatibility depends on voltage and connection: typical inline ratings include ~9 kW at 230 V and ~18.5 kW at 400 V; when connected to motor delta terminals it can be used up to 30 kW at 400 V.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS480D38Y include an internal bypass contactor?\u003c\/h4\u003e \u003cp\u003eNo. The ATS480D38Y is supplied without an internal bypass.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat protection and control features are built in?\u003c\/h4\u003e \u003cp\u003eIt provides torque control (TCS) for controlled acceleration\/deceleration and integrated motor overload protection; the unit is rated for operation up to a 40 °C ambient without derating.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230288417051,"sku":"ATS480D38Y","price":1260.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480d38y-ats480-to-690v-ac_5f19d865-92db-457b-88f4-dcc5917b42ae.jpg?v=1777185479"},{"product_id":"schneider-electric-ats480d47y-ats480","title":"ATS480D47Y, ATS480 Series Soft Starter, 22 kW, 47 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: Schneider Electric ATS480D47Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480D47Y is an ATS480-series soft starter rated for 47 A continuous (normal duty at ≤40 °C) with a heavy‑duty continuous rating of 38 A at 40 °C. It supports three‑phase supply voltages from 208 V up to 690 V AC (50\/60 Hz), and is specified for motor power up to 22 kW at 400–440 V (normal duty) with lower ratings at 230 V and higher voltage classes documented for this model. The unit provides torque-controlled soft‑start and soft‑stop with adjustable current limiting to reduce mechanical stress and limit inrush current during industrial motor starting. The ATS480D47Y includes integrated motor thermal overload protection and other motor protection functions, an IP20 panel-mount enclosure, and options for fieldbus communication via dedicated option cards (Profibus DP, PROFINET, Modbus TCP\/EtherNet‑IP, CANopen), enabling diagnostics and integration into control systems. Typical applications are pumps, fans, compressors and conveyors where controlled starting, reduced network disturbance and built‑in motor protection are required. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 47 A (normal duty at ≤40 °C); 38 A heavy duty at 40 °C.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Examples: 11 kW at 230 V (normal duty); 22 kW at 400–440 V (normal duty). Other voltage power ratings documented up to 37 kW at higher voltages.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208…690 V AC, 3‑phase, 50\/60 Hz.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Torque control with adjustable current limit (torque-controlled soft‑start\/soft‑stop).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e Built‑in bypass contactor (model fitted for reduced heating during run).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated motor thermal overload; overcurrent\/locked‑rotor detection; phase loss and overload\/underload monitoring; overtemperature protection (unit\/motor) as documented.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Optional communication modules available (Profibus DP, PROFINET, Modbus TCP \/ EtherNet‑IP, CANopen variants).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20 (panel mount).\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the continuous current rating of the ATS480D47Y?\u003c\/h4\u003e \u003cp\u003eThe ATS480D47Y is rated 47 A continuous in normal duty at ambient ≤40 °C; heavy‑duty continuous rating is 38 A at 40 °C.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich supply voltages does this ATS480 soft starter support?\u003c\/h4\u003e \u003cp\u003eIt supports 3‑phase supply voltages from 208 V up to 690 V AC at 50\/60 Hz.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat motor sizes can I run with the ATS480D47Y?\u003c\/h4\u003e \u003cp\u003eDocumented motor ratings include 11 kW at 230 V (normal duty) and 22 kW at 400–440 V (normal duty); other voltage‑specific ratings are published for this model.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan the ATS480D47Y be integrated into a PLC or industrial network?\u003c\/h4\u003e \u003cp\u003eYes — Schneider offers optional communication modules (Profibus DP, PROFINET, Modbus TCP\/EtherNet‑IP, and CANopen variants) to enable integration and diagnostics.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230288515355,"sku":"ATS480D47Y","price":1333.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480d47y-ats480-to-690v-ac_880c62e2-0335-4dd0-93a9-221c193aee6d.jpg?v=1777185483"},{"product_id":"schneider-electric-ats480d62y-ats480","title":"ATS480D62Y, ATS480 Series Soft Starter, 30 kW, 62 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS480D62Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480D62Y is a 3‑phase Altivar ATS480 soft starter rated for 62 A (normal duty) and designed for supply voltages from 208 V up to 690 V AC. Depending on supply voltage and connection mode (inline or inside-delta), the ATS480D62Y covers typical motor power ranges up to approximately 15–45 kW (manufacturer distributor data lists 15 kW at low voltages and up to 45 kW at higher voltages for inline configuration; higher delta-configured ratings are supported per installation guidelines). The unit uses Schneider’s Torque Control System (TCS) to manage acceleration and deceleration, and provides integrated motor protection functions such as overload, locked-rotor and phase-loss detection. The model is intended for demanding industrial and infrastructure applications—pumps, fans, compressors, conveyors and other process machinery—where controlled starting, reduced mechanical stress and reliable stopping of high-inertia loads are required. ATS480D62Y is IP20 enclosure rated, supports Modbus RTU serial communication via RJ45 (with optional communication modules available for other networks), and is supplied as an external-bypass type soft starter in the documented product listings. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 62 A (normal duty).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Vendor listings show approximately 15–45 kW (depends on supply voltage and connection mode).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208 V to 690 V AC, 3-phase (50–60 Hz).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Torque Control System (TCS) – torque-based start\/stop control.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e External bypass type (product listings indicate external bypass configuration; internal bypass not indicated).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated thermal\/motor overload protection, locked rotor detection, phase loss\/phase sequence monitoring, excessive start time and underload protections (as listed by product documentation).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Modbus RTU serial (RJ45) standard; optional communication modules available for additional fieldbuses.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20.\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the rated current and voltage range for the ATS480D62Y?\u003c\/h4\u003e \u003cp\u003eThe ATS480D62Y is rated at 62 A (normal duty) and supports 3‑phase supply voltages from 208 V to 690 V AC (50–60 Hz).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat motor sizes can I run with this soft starter?\u003c\/h4\u003e \u003cp\u003eDistributor and product listings indicate motor power coverage of roughly 15–45 kW depending on supply voltage and whether the starter is wired inline or inside a delta connection; always verify installation wiring and nameplate ratings for final selection.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS480D62Y include a bypass contactor?\u003c\/h4\u003e \u003cp\u003eDocuments and vendor pages describe this model as an external-bypass type; internal bypass is not indicated on the product listings for ATS480D62Y.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich communications are available for system integration?\u003c\/h4\u003e \u003cp\u003eThe ATS480D62Y provides Modbus RTU serial communication via an RJ45 port as standard; additional Schneider communication modules are offered to add Profinet, EtherNet\/IP, Modbus TCP and other protocols where required.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230288580891,"sku":"ATS480D62Y","price":1525.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480d62y-ats480-to-690v-ac_323520bc-9a63-4bd8-8983-c3311166e9b0.jpg?v=1777185490"},{"product_id":"schneider-electric-ats480d75y-ats480","title":"ATS480D75Y, ATS480 Series Soft Starter, 37 kW, 75 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: Schneider Electric ATS480D75Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480D75Y is an ATS480-series soft starter rated for 75 A (normal duty) and designed for three-phase supply voltages from 208 V to 690 V. Depending on supply voltage and wiring (inline or delta), this model covers a wide motor power range — commonly specified as 18.5 kW at 230 V (inline normal duty) up to 55 kW at 400–690 V when connected in the motor delta (normal duty). The ATS480D75Y provides torque control (TCS) for controlled acceleration and deceleration, and includes motor overload protection. It supports dynamic braking and DC injection for stopping high-inertia loads and can be installed inline or wired to the motor delta to reduce operational current. With IP20 protection and conformity to IEC\/EN 60947-4-1, the ATS480D75Y is intended for process and infrastructure applications such as pumps, compressors, conveyors and other industrial motor loads that require reduced mechanical stress, limited inrush, and enhanced start\/stop control. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 75 A (normal duty); 62 A (heavy duty at 40 °C)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Typical: 18.5 kW at 230 V (inline normal duty) up to 55 kW (400–690 V, delta\/inline normal duty) — see model wiring and duty class for exact values\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208 V to 690 V AC, 50\/60 Hz\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Torque control (TCS) with soft start\/stop, dynamic braking and DC injection for stopping\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e No (internal bypass not included)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated motor overload protection\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Optional communication modules available (Modbus TCP\/EtherNet‑IP, Profibus DP, CANopen, PROFINET) as add‑on cards\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat supply voltages does the ATS480D75Y support?\u003c\/h4\u003e \u003cp\u003eThe ATS480D75Y supports 3-phase supply voltages from 208 V to 690 V AC at 50\/60 Hz.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the rated current and how does duty class affect it?\u003c\/h4\u003e \u003cp\u003eRated operational current is 75 A in normal duty. For heavy-duty applications the rated current is reduced (specified as 62 A at 40 °C for heavy duty).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan this model stop high-inertia loads?\u003c\/h4\u003e \u003cp\u003eYes — the ATS480D75Y supports dynamic braking and DC injection to efficiently stop high-inertia applications.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS480D75Y include an internal bypass or fieldbus connectivity?\u003c\/h4\u003e \u003cp\u003eThere is no internal bypass on this model. Communication modules (Profibus DP, Modbus TCP\/EtherNet‑IP, CANopen, PROFINET, etc.) are available as optional add-on cards.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230288646427,"sku":"ATS480D75Y","price":1600.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480d75y-ats480-to-690v-ac_3287cf37-dca7-4ce3-b82c-699d31102185.jpg?v=1777185494"},{"product_id":"schneider-electric-ats480d88y-ats480","title":"ATS480D88Y, ATS480 Series Soft Starter, 45 kW, 88 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: Schneider Electric ATS480D88Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480D88Y is an ATS480-series soft starter rated for 88 A normal-duty operation, designed for three-phase supply voltages from 208 V up to 690 V. It supports a wide motor power range depending on supply voltage and connection: typical inline ratings include 22 kW at 230 V and 45 kW at 400 V (normal duty), with higher ratings available up to 75 kW at the upper voltage classes (normal duty). The device uses Schneider’s true torque-control algorithm for controlled ramp-up and ramp-down to reduce mechanical stress and limit inrush current, and it includes integrated motor overload protection. The ATS480D88Y is IP20 and intended for process and infrastructure applications where reliable industrial motor starting is required — pumps, fans, compressors, conveyors and similar loads. Notable verified points for this model: 88 A rated operational current (normal duty), no internal bypass, torque control, and a range of optional communication modules (Profibus DP, PROFINET, Modbus TCP \/ EtherNet‑IP, CANopen) for integration into automation systems. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 88 A (normal duty)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Examples — 22 kW at 230 V (inline, normal duty); 45 kW at 400 V (inline, normal duty); up to 75 kW at 660–690 V (normal duty). Heavy-duty ratings are lower (see manufacturer tables).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208…690 V AC (3-phase)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e True torque control (electronic torque-based soft start)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e No (external bypass \/ external contactor arrangements required)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated motor overload protection\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Optional communication modules available — Profibus DP, PROFINET, Modbus TCP \/ EtherNet‑IP, CANopen variants\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP20\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the maximum supply voltage the ATS480D88Y supports?\u003c\/h4\u003e \u003cp\u003eThe ATS480D88Y supports three-phase supply voltages from 208 V up to 690 V AC.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat rated current and motor sizes does the ATS480D88Y cover?\u003c\/h4\u003e \u003cp\u003eRated operational current is 88 A (normal duty). Typical motor examples: 22 kW at 230 V and 45 kW at 400 V (normal duty); ratings up to 75 kW apply at higher voltage classes per the manufacturer tables.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS480D88Y include a built-in bypass contactor?\u003c\/h4\u003e \u003cp\u003eNo. The ATS480D88Y is supplied without an internal bypass; an external bypass\/contact arrangement is required if bypassing is needed.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan the ATS480D88Y be integrated into an automation network?\u003c\/h4\u003e \u003cp\u003eYes. Communication option modules are available for Profibus DP, PROFINET, Modbus TCP \/ EtherNet‑IP and CANopen to integrate the soft starter into control systems.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230288777499,"sku":"ATS480D88Y","price":1952.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480d88y-ats480-to-690v-ac_195a6bf5-d025-462d-950e-29c3844f27ba.jpg?v=1777185498"},{"product_id":"schneider-electric-ats480m10y-ats480","title":"ATS480M10Y, ATS480 Series Soft Starter, 500 kW, 1000 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: ATS480M10Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480M10Y is a heavy‑duty ATS480 soft starter sized for large three‑phase motors. It is rated for 1000 A (normal duty) with a heavy‑duty rating of 790 A at 40 °C and supports supply voltages from 208 to 690 V AC (50\/60 Hz). Depending on system voltage and connection, motor power compatibility ranges from roughly 250 kW at low voltages up to 900 kW at 660–690 V (normal duty ratings), making this model suitable for large pumps, fans, compressors, conveyors and other process machinery in industrial installations. The unit provides true torque control, integrated motor overload protection and is supplied with a 110–250 V AC control circuit range. Communication and fieldbus flexibility are available via an RJ45 interface and optional communication modules (Modbus TCP\/EtherNet‑IP, PROFINET, Profibus, CANopen), and the product is supplied in an IP00 enclosure for panel mounting. The ATS480M10Y is designed for applications requiring controlled starting\/stopping of high‑power motors and where external bypass and panel integration are used for continuous operation. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 1000 A (normal duty); 790 A (heavy duty at 40 °C)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e Up to 900 kW (normal duty at 660–690 V); example values: 250 kW at 230 V (normal duty); 500 kW at 400 V (normal duty).\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208…690 V AC, 50\/60 Hz\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e True torque control (electronic torque control \/ voltage ramp capabilities)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e External bypass arrangement (external bypass \/ panel bypass typically used)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated motor overload protection (thermal\/overload functions)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e RJ45 port; optional communication modules available (Modbus TCP\/EtherNet‑IP, PROFINET, Profibus, CANopen as option cards)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP00 (panel mounting)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Circuit Voltage:\u003c\/strong\u003e 110…250 V AC (control supply)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the maximum continuous current for the ATS480M10Y?\u003c\/h4\u003e \u003cp\u003eThe ATS480M10Y is rated 1000 A for normal duty; its heavy‑duty (40 °C) continuous rating is 790 A.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhich supply voltages and motor power levels does this model support?\u003c\/h4\u003e \u003cp\u003eIt supports 208–690 V AC. Motor power examples (normal duty): ~250 kW at 230 V, ~500 kW at 400 V, up to 900 kW at 660–690 V (normal duty ratings).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS480M10Y include onboard communication for PLC integration?\u003c\/h4\u003e \u003cp\u003eThe unit includes an RJ45 interface and can accept optional communication modules for Modbus TCP\/EtherNet‑IP, PROFINET, Profibus or CANopen.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eIs a bypass contactor included with the starter?\u003c\/h4\u003e \u003cp\u003eThis model is supplied for use with an external bypass arrangement (external or panel bypass is used rather than an internal bypass).\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230289039643,"sku":"ATS480M10Y","price":14112.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480m10y-ats480-to-690v-ac_cfed3269-7f66-411f-b404-2e8aab8bb6de.jpg?v=1777185502"},{"product_id":"schneider-electric-ats480m12y-ats480","title":"ATS480M12Y, ATS480 Series Soft Starter, 630 kW, 1200 A, 208 to 690V AC","description":"\u003cdiv\u003e\n\u003csection id=\"series-overview\"\u003e \u003ch2\u003eSchneider Electric ATS480 Soft Starter Series – Overview\u003c\/h2\u003e \u003cp\u003e Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors. \u003c\/p\u003e \u003c\/section\u003e \u003chr\u003e \u003csection id=\"product-description\"\u003e \u003ch3\u003eProduct Description: Schneider Electric ATS480M12Y\u003c\/h3\u003e \u003cp\u003e The Schneider Electric ATS480M12Y is an ATS480-series soft starter with a rated operational current of 1200 A, designed for three-phase supply voltages from 208 V to 690 V AC. It supports large asynchronous motors and is specified to control motor power up to the hundreds of kilowatts range: typical verified ratings for this frame include standard connection motor powers of approximately 355 kW at 230 V and 630 kW at 400 V, with higher triangle\/delta-connection ratings reported (for example up to 500 kW in delta at 230 V and ~680 kW in delta at 400 V). The unit implements Schneider’s torque control (TCS) and standard soft-start voltage ramp strategies to manage acceleration and deceleration, and includes integrated motor overload protection. ATS480M12Y is built for heavy industrial uses — process lines, pumps, compressors, conveyors and large rotating equipment — where limiting inrush current, reducing mechanical stress, and providing controlled stopping (including dynamic braking and DC injection features reported for the series) are required. Communication options and modular interface support enable integration into industrial automation systems. \u003c\/p\u003e \u003c\/section\u003e \u003csection id=\"technical-attributes\"\u003e \u003ch3\u003eKey Soft Starter Attributes\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eRated Operational Current (Ie):\u003c\/strong\u003e 1200 A\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Power Range:\u003c\/strong\u003e standard ratings reported: ~355 kW @ 230 V; ~630 kW @ 400 V (triangle\/delta connection allows higher kW capability: e.g., ~500 kW @ 230 V delta; ~680 kW @ 400 V delta)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 208 – 690 V AC (three-phase)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Torque control (TCS) and voltage ramp soft-start\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eBuilt-in Bypass:\u003c\/strong\u003e No (internal bypass not included)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eMotor Protection Functions:\u003c\/strong\u003e Integrated motor overload protection\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Modular\/optional: Modbus RTU (serial), Modbus TCP, EtherNet\/IP, PROFINET, PROFIBUS DP, CANopen (fieldbus modules available)\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eEnclosure \/ Protection Class:\u003c\/strong\u003e IP00 (frame, varies by installation\/kit)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/section\u003e \u003csection id=\"technical-faq\"\u003e \u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat supply voltages does the ATS480M12Y accept?\u003c\/h4\u003e \u003cp\u003eThe ATS480M12Y is rated for three-phase supply voltages from 208 V up to 690 V AC.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eWhat is the rated current and what motor sizes can it handle?\u003c\/h4\u003e \u003cp\u003eThe unit is rated at 1200 A. Verified motor power examples include ~355 kW at 230 V (standard) and ~630 kW at 400 V (standard); delta\/triangle connections raise the usable kW range as shown in manufacturer distributor data.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eDoes the ATS480M12Y include an internal bypass contactor?\u003c\/h4\u003e \u003cp\u003eNo—this model is listed without an internal bypass; external bypass\/contactors are used where required.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eCan the ATS480M12Y communicate with a PLC or networked control system?\u003c\/h4\u003e \u003cp\u003eYes. The ATS480 platform supports communication modules (Modbus RTU, Modbus TCP, EtherNet\/IP, PROFINET, PROFIBUS DP, CANopen) via optional\/fieldbus modules for integration.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"faq-item\"\u003e \u003ch4\u003eIs torque control available for heavy inertia applications?\u003c\/h4\u003e \u003cp\u003eYes. The ATS480M12Y uses Schneider’s torque control (TCS) algorithm and the series provides dynamic braking and DC injection capabilities used for high-inertia stopping and controlled acceleration.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50230289301787,"sku":"ATS480M12Y","price":15016.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/schneider-electric-ats480m12y-ats480-to-690v-ac_a6940205-64fa-415e-94c9-2d19f89a48da.jpg?v=1777185506"}],"url":"https:\/\/stoklink.com\/collections\/ats480.oembed?page=2","provider":"Stoklink","version":"1.0","type":"link"}