{"title":"ABB Basic M MCBs","description":"\u003cp\u003eABB Basic M MCBs are entry-level DIN-rail miniature circuit breakers with a 3 kA breaking capacity. The range covers 6 A to 63 A in 1, 2, 3 and 4 poles, with more than 80 products. Stoklink ships worldwide from Turkey and quotes volumes on request.\u003c\/p\u003e\u003ch2\u003eWhat's in this range\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBMS311, BMS313 and BMS314 types for 1P, 3P and 4P circuits.\u003c\/li\u003e\n\u003cli\u003eB and C curve versions at 230 V and 400 V AC.\u003c\/li\u003e\n\u003cli\u003eFor higher fault levels see \u003ca href=\"\/collections\/abb-s200-mcb\"\u003eABB System pro M compact S200 MCBs\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e3 kA breaking capacity suits only installations with a low prospective short-circuit current. Check it first.\u003c\/li\u003e\n\u003cli\u003eSelect the curve from the load: B for resistive circuits, C for general loads.\u003c\/li\u003e\n\u003cli\u003eSelect the rating from the cable and the pole count from the supply system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003ch3\u003eWhere is a 3 kA MCB acceptable?\u003c\/h3\u003e\u003cp\u003eIn small installations where the calculated fault current at the board is below 3 kA. Higher fault levels need a 6 kA or 10 kA breaker.\u003c\/p\u003e\u003ch3\u003eWhat do the letters in BMS311C32 mean?\u003c\/h3\u003e\u003cp\u003eBMS311 is the series and pole count, C is the curve and 32 is the rated current in amperes.\u003c\/p\u003e\u003ch3\u003eCan I order Basic M breakers in bulk?\u003c\/h3\u003e\u003cp\u003eStoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so request a quote with your part numbers and quantities.\u003c\/p\u003e","products":[{"product_id":"abb-2cds631031r0105-bms311b10-1p-10a-mcb","title":"ABB 2CDS631031R0105 BMS311B10 1P 10A B-Curve 3kA 230V DIN Rail Miniature Circuit Breaker (MCB)","description":"\u003cp\u003eThe ABB BMS311B10 miniature circuit breaker (SKU: 2CDS631031R0105) is a 1-pole, 10A, B-curve MCB from the Basic M BMS series, rated at 230V AC per IEC 60898-1 and designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panels. With a breaking capacity of 3 kA at 230\/400V AC and compact DIN rail mounting dimensions of 17.5mm wide, the BMS311B10 delivers dependable protection in space-constrained enclosures.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311B10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 230\/400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers (industrial applications)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European adoption of insulation coordination requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General standard series for circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e General standard series for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant — restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant — registration, evaluation, authorisation and restriction of chemicals (EU regulation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant — waste electrical and electronic equipment directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical panels and sub-distribution boards\u003c\/li\u003e\n\u003cli\u003eLight industrial control panels and machinery protection\u003c\/li\u003e\n\u003cli\u003eProtection of lighting circuits, socket outlet circuits, and small motor loads (B-curve)\u003c\/li\u003e\n\u003cli\u003eDIN rail installations requiring compact 17.5mm single-pole breakers\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFAQ\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat does the B-curve mean for the BMS311B10?\u003c\/strong\u003e The B-curve trips the breaker at 3–5× the rated current for instantaneous protection, making it ideal for resistive and lightly inductive loads such as lighting and socket circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs the ABB BMS311B10 compliant with IEC 60898-1?\u003c\/strong\u003e Yes. The BMS311B10 is fully certified to IEC 60898-1 for household and similar installations, as well as IEC 60947-2 for industrial applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan the BMS311B10 be used on a 400V system?\u003c\/strong\u003e Per IEC 60947-2, the rated voltage extends to 440V, giving it flexibility for industrial 3-phase distribution systems when used as a single-pole device.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229167161627,"sku":"2CDS631031R0105","price":4.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0105-bms311b10-circuit-breaker-mcb_24b0fd56-1b38-4f99-854b-ba9671b49719.webp?v=1777162297"},{"product_id":"abb-2cds631031r0165-bms311b16-1p-16a-3ka-mcb","title":"ABB 2CDS631031R0165 BMS311B16 1P 16A 3kA B-Curve Miniature Circuit Breaker MCB 230V AC","description":"\u003cp\u003eThe ABB BMS311B16 (SKU: 2CDS631031R0165) is a 1-pole 16A miniature circuit breaker (MCB) from the Basic M BMS series, designed for reliable overcurrent and short-circuit protection in residential and light commercial installations. Rated at 230V AC per IEC 60898-1 and 440V per IEC 60947-2, the BMS311B16 delivers a breaking capacity of 3 kA at 230\/400V AC, making it a dependable choice for standard distribution boards and control panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311B16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0165\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC (IEC 60898-1) \/ 440 V (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu\/Ics)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043328\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e General insulation coordination standard for low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General series standard for circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e General series standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH chemical safety regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eLight commercial and industrial control panel protection\u003c\/li\u003e\n\u003cli\u003eSingle-phase circuit protection in building installations\u003c\/li\u003e\n\u003cli\u003eDIN rail mounted branch circuit protection up to 16A\u003c\/li\u003e\n\u003cli\u003eFinal circuit protection in automation and control cabinets\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229167358235,"sku":"2CDS631031R0165","price":4.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0165-bms311b16-mcb-230v-ac_fc592a50-db19-471b-8d86-d716056e3b1a.webp?v=1777162309"},{"product_id":"abb-2cds631031r0065-bms311b06-1p-6a-mcb","title":"ABB 2CDS631031R0065 BMS311B06 1P 6A B-Curve 3kA 230V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311B06 (SKU: 2CDS631031R0065) is a 1-pole, 6A, B-curve miniature circuit breaker (MCB) from the Basic M BMS series, designed for reliable overcurrent and short-circuit protection in residential and light commercial control panels. Rated at 230V AC per IEC 60898-1 and 440V AC per IEC 60947-2, the BMS311B06 delivers a breaking capacity of 3 kA and fits into compact installations with its slim 17.5mm wide DIN rail profile.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311B06\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0065\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779038010\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar installations — circuit breakers for overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination — general requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit breakers for overcurrent protection for household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS (EU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863):\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Toxic Substances Control Act compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste electrical and electronic equipment directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eControl panel protection in light commercial and industrial automation applications\u003c\/li\u003e\n  \u003cli\u003eBranch circuit protection for lighting and low-load circuits\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting in compact electrical enclosures\u003c\/li\u003e\n  \u003cli\u003eProtection of sensitive electrical components requiring B-curve characteristics\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229168079131,"sku":"2CDS631031R0065","price":5.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0065-bms311b06-miniature-circuit-breaker_50db70e7-8e00-4b05-9d75-c71733f8ab5c.webp?v=1777162285"},{"product_id":"abb-2cds631031r0255-bms311b25-1p-25a-3ka-mcb","title":"ABB 2CDS631031R0255 BMS311B25 1P 25A 3kA B-Curve 230V AC Miniature Circuit Breaker MCB","description":"\u003cp\u003eThe ABB BMS311B25 (SKU: 2CDS631031R0255) is a 1-pole 25A B-curve miniature circuit breaker (MCB) from the Basic M BMS series, rated at 230V AC per IEC 60898-1 and 440V per IEC 60947-2. Delivering a breaking capacity of 3 kA, this compact BMS311B25 unit is engineered for reliable overcurrent protection in residential, commercial, and light industrial control panel applications, housed in a slim 17.5mm wide DIN rail-mountable enclosure weighing just 93g.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311B25\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0255\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043489\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standards for low-voltage installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European adoption of insulation coordination standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General circuit breaker protection standard series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear standards series\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances (EC 1907\/2006)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Compliant with US Toxic Substances Control Act requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial building electrical panels and sub-distribution boards\u003c\/li\u003e\n  \u003cli\u003eLight industrial control panels and machinery protection\u003c\/li\u003e\n  \u003cli\u003eBranch circuit protection for lighting and socket circuits\u003c\/li\u003e\n  \u003cli\u003eDIN rail installations in compact enclosures where a slim 17.5mm profile is essential\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229168668955,"sku":"2CDS631031R0255","price":4.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0255-bms311b25-circuit-breaker-mcb_b51f9917-e69f-48f4-8a36-58149695cdde.webp?v=1777162333"},{"product_id":"abb-2cds631031r0205-bms311b20-1p-20a-3ka-mcb","title":"ABB 2CDS631031R0205 BMS311B20 1P 20A 3kA B-Curve Miniature Circuit Breaker Basic M BMS Series","description":"\u003cp\u003eThe ABB BMS311B20 miniature circuit breaker (MCB), catalog number BMS311B20, SKU 2CDS631031R0205, is a 1-pole, 20 A, B-curve device from the Basic M BMS series offering 3 kA breaking capacity at 230\/400 V AC. Rated to both IEC 60898-1 (domestic\/commercial) and IEC 60947-2 (industrial) standards, it delivers reliable overcurrent and short-circuit protection in a compact 17.5 mm wide DIN-rail-mount housing — ideal for control panels, distribution boards, and industrial automation enclosures.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311B20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0205\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043403\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu\/Ics)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear — circuit breakers for industrial applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e General insulation coordination standard for low-voltage equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear general standards framework\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — compliant with applicable EU directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — free from restricted materials per EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — proper end-of-life disposal classification\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection in residential and commercial distribution boards\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panel circuit protection in automation and machinery enclosures\u003c\/li\u003e\n  \u003cli\u003eBranch circuit protection for lighting, HVAC, and general-purpose loads\u003c\/li\u003e\n  \u003cli\u003eProtection of cables and conductors in DIN-rail-mounted assemblies\u003c\/li\u003e\n  \u003cli\u003eCompact single-pole protection where space is limited (17.5 mm pitch)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229170176283,"sku":"2CDS631031R0205","price":4.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0205-bms311b20-m-bms-series_0cc8f124-685c-42ca-b9f8-e1c57dc28f46.webp?v=1777162321"},{"product_id":"abb-2cds633031r0205-bms313b20-3p-20a-mcb","title":"ABB 2CDS633031R0205 BMS313B20 3P 20A 3kA 400V AC B-Curve Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS313B20 (SKU: 2CDS633031R0205) is a 3-pole 20 A B-curve miniature circuit breaker from the Basic M BMS series, rated at 400 V AC with a breaking capacity of 3 kA per IEC 60898-1. Designed for compact residential and light commercial distribution boards, the BMS313B20 delivers reliable overcurrent and short-circuit protection in a slim 52.5 mm-wide, DIN-rail-mount format — making it an ideal choice for engineers and panel builders seeking cost-effective, standards-compliant circuit protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313B20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044844\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Rated and tested as a household and similar installation circuit breaker\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Compliant as an industrial low-voltage circuit breaker (440 V AC rating)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e General insulation coordination standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Core circuit-breaker performance standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear standard family\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets all applicable EU directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant, free of restricted materials\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Toxic Substances Control Act — compliant for US market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive — registered and compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eLight commercial and industrial control panel circuit protection\u003c\/li\u003e\n\u003cli\u003eBranch circuit protection for lighting and general-purpose loads\u003c\/li\u003e\n\u003cli\u003eDIN-rail-mount installations requiring compact 3-pole switching\u003c\/li\u003e\n\u003cli\u003eApplications demanding IEC 60898-1 and IEC 60947-2 dual compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229171650843,"sku":"2CDS633031R0205","price":20.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0205-bms313b20-miniature-circuit-breaker_b75074e3-63be-4b24-bdf7-e2a86e70e0be.webp?v=1777162480"},{"product_id":"abb-2cds633031r0105-bms313b10-3p-10a-mcb","title":"ABB 2CDS633031R0105 BMS313B10 3P 10A 3kA B-Curve 400V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS313B10 (SKU: 2CDS633031R0105) is a 3-pole 10A B-curve miniature circuit breaker from the Basic M BMS series, rated at 400V AC with a breaking capacity of 3 kA per IEC 60898-1. Designed for reliable overcurrent and short-circuit protection in industrial control panels and building electrical installations, the BMS313B10 delivers compact, DIN rail-mountable performance with a 52.5 × 88 × 69 mm footprint and a total weight of just 279 g.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313B10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044684\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e International standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e International standard for low-voltage switchgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear standard family\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar circuit breaker performance standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marking — meets EU electrical equipment directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU chemicals regulation (EC) No 1907\/2006\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Compliant with US Toxic Substances Control Act requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant — supports responsible disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in industrial control panels and automation cabinets\u003c\/li\u003e\n\u003cli\u003eProtection of branch circuits in commercial and light industrial building installations\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting in distribution boards and motor control centres\u003c\/li\u003e\n\u003cli\u003eSuitable for resistive and low-inductive loads requiring B-curve trip characteristics\u003c\/li\u003e\n\u003cli\u003eUse in applications rated up to 400V AC \/ 440V per IEC 60947-2\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229171781915,"sku":"2CDS633031R0105","price":20.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0105-bms313b10-miniature-circuit-breaker_67472bb9-62f2-4af4-b650-1d1711050b04.webp?v=1777162460"},{"product_id":"abb-2cds631031r0635-bms311b63-1p-63a-3ka-mcb","title":"ABB 2CDS631031R0635 BMS311B63 1P 63A 3kA B-Curve 230V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311B63 miniature circuit breaker (SKU: 2CDS631031R0635) is a 1-pole, 63 A, 3 kA breaking capacity MCB from the Basic M BMS series, designed for reliable overcurrent and short-circuit protection in residential and light commercial installations. Rated at 230 V AC per IEC 60898-1 and 440 V AC per IEC 60947-2, the BMS311B63 offers compact B-curve protection in a slim 17.5 mm wide DIN-rail housing suitable for space-constrained control panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311B63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0635\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043809\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear — circuit breakers for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General circuit breaker performance standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB Certificate (IEC 60898):\u003c\/strong\u003e International CB scheme certification for circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS (EU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863):\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliance with EU Waste Electrical and Electronic Equipment directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eLight commercial and industrial control panel circuit protection\u003c\/li\u003e\n\u003cli\u003eFinal circuit protection for lighting and socket outlet circuits\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounted installations requiring compact 17.5 mm single-pole breakers\u003c\/li\u003e\n\u003cli\u003eApplications requiring IEC 60947-2 rated devices up to 440 V AC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229172142363,"sku":"2CDS631031R0635","price":7.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0635-bms311b63-miniature-circuit-breaker_8e3730a7-b2fe-43a2-b87e-e4ce819dce97.webp?v=1777162381"},{"product_id":"abb-2cds633031r0255-bms313b25-3p-25a-mcb","title":"ABB 2CDS633031R0255 BMS313B25 3P 25A 3kA 400V AC B-Curve Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS313B25 miniature circuit breaker (MCB), catalog number BMS313B25 \/ SKU 2CDS633031R0255, is a 3-pole, 25A, B-curve device from the Basic M BMS series rated at 400V AC with a breaking capacity of 3kA. Designed to IEC 60898-1 and IEC 60947-2, it delivers reliable overcurrent and short-circuit protection for residential, commercial, and light industrial control panels. Compact at 52.5 × 88 × 69mm and weighing just 279g, it fits neatly on standard DIN rail installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313B25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0255\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC (IEC 60898-1) \/ 440 V (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044929\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar installations — circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard family compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB Certificate (IEC 60898 \/ IEC 60947):\u003c\/strong\u003e International CB scheme certification for global market acceptance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets all applicable EU directives\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC) No 1907\/2006\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229172896027,"sku":"2CDS633031R0255","price":20.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0255-bms313b25-miniature-circuit-breaker_34d75de3-f204-4c76-8862-0b52b556da65.webp?v=1777162492"},{"product_id":"abb-2cds631031r0325-bms311b32-1p-32a-mcb","title":"ABB 2CDS631031R0325 BMS311B32 1P 32A B-Curve 3kA 230V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311B32 (SKU: 2CDS631031R0325) is a 1-pole, 32 A, B-curve miniature circuit breaker (MCB) from the Basic M BMS series, rated at 230 V AC per IEC 60898-1 and 440 V AC per IEC 60947-2, with a breaking capacity of 3 kA. Designed for residential, commercial, and light-industrial control panel applications, the BMS311B32 provides reliable overcurrent and short-circuit protection with a compact 17.5 mm wide DIN-rail-mounted footprint weighing only 93 g, making it an efficient choice for space-constrained enclosures.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311B32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043564\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers for industrial use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General requirements for miniature circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e General rules for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU chemical safety regulation (EC) No 1907\/2006\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical panel protection\u003c\/li\u003e\n\u003cli\u003eLight-industrial control panel circuit protection\u003c\/li\u003e\n\u003cli\u003eFinal circuit protection for lighting and socket outlet circuits (B-curve)\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounted switchboard assemblies requiring compact 17.5 mm wide modules\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229175124251,"sku":"2CDS631031R0325","price":5.74,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0325-bms311b32-miniature-circuit-breaker_ed34e4ae-9ab6-4f3f-ba4c-6f272435ff00.webp?v=1777162345"},{"product_id":"abb-2cds631031r0505-bms311b50-1p-50a-mcb","title":"ABB 2CDS631031R0505 BMS311B50 1P 50A 3kA B-Curve Miniature Circuit Breaker MCB Basic M BMS Series","description":"\u003cp\u003eThe ABB BMS311B50 (SKU: 2CDS631031R0505) is a 1-pole, 50 A, B-curve miniature circuit breaker (MCB) from the Basic M BMS series, rated for 230 V AC per IEC 60898-1 and 440 V AC per IEC 60947-2, with a breaking capacity of 3 kA. Designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial installations, the BMS311B50 delivers dependable performance in a compact 17.5 mm wide DIN rail mount package weighing just 93 g.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311B50\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0505\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043724\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers for industrial applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard for low-voltage equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General requirements for circuit breakers for overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEU Directive 2011\/65\/EU (RoHS 2):\u003c\/strong\u003e European Union restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmendment 2015\/863:\u003c\/strong\u003e EU RoHS amendment restricting additional hazardous substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant with European e-waste regulations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial building electrical panels and consumer units\u003c\/li\u003e\n  \u003cli\u003eLight industrial control panels and machinery protection\u003c\/li\u003e\n  \u003cli\u003eFinal circuit protection for lighting and general power circuits\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounted switchgear assemblies\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229176959259,"sku":"2CDS631031R0505","price":6.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0505-bms311b50-m-bms-series_94b3f39c-372c-4ae1-b271-bf0caed3f3a6.webp?v=1777162368"},{"product_id":"abb-2cds633031r0065-bms313b06-3p-6a-mcb","title":"ABB 2CDS633031R0065 BMS313B06 3P 6A B-Curve 3kA 400V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS313B06 miniature circuit breaker (2CDS633031R0065) is a 3-pole, 6 A, B-curve MCB from the Basic M BMS series, rated at 400 V AC per IEC 60898-1 with a breaking capacity of 3 kA. Designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panels, the BMS313B06 delivers dependable performance in a compact 52.5 × 88 × 69 mm DIN-rail-mounted package weighing just 279 g.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313B06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0065\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTripping Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044608\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for household and similar installations — miniature circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Complies with applicable EU directives for the European Economic Area\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS (EU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863):\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eProtection of lighting circuits in commercial buildings\u003c\/li\u003e\n\u003cli\u003eControl panel protection in light industrial automation environments\u003c\/li\u003e\n\u003cli\u003eMachine and equipment branch-circuit protection where B-curve characteristics are required\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounted installations requiring a compact 3-pole MCB footprint\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229177450779,"sku":"2CDS633031R0065","price":24.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0065-bms313b06-miniature-circuit-breaker_c1a92cc9-de95-4bf5-b6b2-1f8961d8144e.webp?v=1777162447"},{"product_id":"abb-2cds631031r0405-bms311b40-1p-40a-3ka-mcb","title":"ABB 2CDS631031R0405 BMS311B40 1P 40A 3kA B-Curve 230V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311B40 (SKU: 2CDS631031R0405) is a 1-pole, 40A, B-curve miniature circuit breaker (MCB) from the Basic M BMS series, rated at 230V AC per IEC 60898-1 and 440V AC per IEC 60947-2, with a breaking capacity of 3 kA. Designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panel installations, the BMS311B40 delivers compact, DIN-rail-ready performance in a 17.5 mm wide form factor.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0405\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043649\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit breakers for overcurrent protection — general series standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general rules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — EU compliant disposal classification\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical panel installations\u003c\/li\u003e\n\u003cli\u003eLight industrial control panels and machinery protection\u003c\/li\u003e\n\u003cli\u003eSingle-phase circuit protection at 230V AC\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting in compact enclosures (17.5 mm pitch)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229177581851,"sku":"2CDS631031R0405","price":5.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0405-bms311b40-miniature-circuit-breaker_a805f16f-a7ff-490d-910a-a1bd03313d34.webp?v=1777162357"},{"product_id":"abb-2cds633031r0325-bms313b32-32a-3p-mcb","title":"ABB 2CDS633031R0325 BMS313B32 3P 32A B-Curve 3kA 400V Miniature Circuit Breaker MCB","description":"\u003cp\u003eThe ABB BMS313B32 miniature circuit breaker (MCB), catalog number BMS313B32 and SKU 2CDS633031R0325, is a 3-pole, 32 A, B-curve device from the Basic M BMS series rated for 400 V AC with a breaking capacity of 3 kA per IEC 60898-1. Designed for cost-effective overcurrent and short-circuit protection in residential, commercial, and light industrial distribution boards, BMS313B32 offers reliable performance in compact DIN rail form factor.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313B32\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0325\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779045001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General series standard for overcurrent circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC60898-1:\u003c\/strong\u003e Household and similar circuit-breaker performance requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e General series standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n  \u003cli\u003eCommercial building electrical panel protection for lighting and socket circuits\u003c\/li\u003e\n  \u003cli\u003eLight industrial control panels requiring compact 3-pole DIN rail MCBs\u003c\/li\u003e\n  \u003cli\u003eFinal distribution circuits where B-curve tripping characteristics are specified\u003c\/li\u003e\n  \u003cli\u003eCost-optimised installations requiring IEC 60898-1 and IEC 60947-2 dual compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229177680155,"sku":"2CDS633031R0325","price":25.76,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0325-bms313b32-circuit-breaker-mcb_7fa9a25b-b47c-426f-b19d-a36e3cba45fc.webp?v=1777162505"},{"product_id":"abb-2cds631031r0064-bms311c06-1p-6a-3ka-mcb","title":"ABB 2CDS631031R0064 BMS311C06 1P 6A 3kA C-Curve Basic M BMS Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311C06 miniature circuit breaker (SKU: 2CDS631031R0064) is a 1-pole, 6A, C-curve MCB from the Basic M BMS series, rated at 230V AC per IEC 60898-1 and 440V per IEC 60947-2, with a breaking capacity of 3kA. Designed for reliable overcurrent and short-circuit protection in residential and light commercial control panels, the BMS311C06 offers a compact 17.5mm DIN rail footprint suitable for space-constrained installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311C06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0064\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043168\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e International standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General series standard for circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substance safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Compliant with US Toxic Substances Control Act requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Registered under EU Waste Electrical and Electronic Equipment Directive for proper end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eLight commercial and industrial control panel protection\u003c\/li\u003e\n\u003cli\u003eBranch circuit protection for loads up to 6A on single-phase 230V AC systems\u003c\/li\u003e\n\u003cli\u003eDIN rail mounted installations requiring compact 17.5mm width breakers\u003c\/li\u003e\n\u003cli\u003eAutomation and machinery control cabinets requiring IEC 60947-2 rated devices\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229178073371,"sku":"2CDS631031R0064","price":6.04,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0064-bms311c06-miniature-circuit-breaker_526ea620-2648-4f40-a6dd-981afbf90690.webp?v=1777162280"},{"product_id":"abb-2cds633031r0405-bms313b40-3p-40a-mcb","title":"ABB 2CDS633031R0405 BMS313B40 3P 40A 3kA 400V AC B-Curve Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS313B40 (SKU: 2CDS633031R0405) is a 3-pole 40 A B-curve miniature circuit breaker (MCB) from the Basic M BMS series, rated at 400 V AC with a breaking capacity of 3 kA per IEC 60898-1. Designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panels, the BMS313B40 delivers consistent performance in a compact 52.5 × 88 × 69 mm DIN-rail-mount housing.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313B40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0405\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.8 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779045087\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB Certificate acc. to IEC 60898:\u003c\/strong\u003e International CB scheme certification for global market acceptance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European standard for insulation coordination\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC) No 1907\/2006\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229178138907,"sku":"2CDS633031R0405","price":26.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0405-bms313b40-miniature-circuit-breaker_e6b96d60-6387-405b-8189-e7aa73feee82.webp?v=1777162518"},{"product_id":"abb-2cds631031r0254-bms311c25-1p-25a-mcb","title":"ABB 2CDS631031R0254 BMS311C25 1P 25A 3kA C-Curve Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311C25 (SKU: 2CDS631031R0254) is a 1-pole 25A C-curve miniature circuit breaker from the Basic M BMS series, designed to provide reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panel applications. Rated at 230 V AC per IEC 60898-1 and 440 V per IEC 60947-2, the BMS311C25 delivers a breaking capacity of 3 kA at 230\/400 V AC and dissipates just 3.2 W per pole for efficient thermal management.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311C25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0254\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043441\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General circuit breaker protection standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear general requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Restriction of Hazardous Substances Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Compliant with US Toxic Substances Control Act\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical panel protection\u003c\/li\u003e\n\u003cli\u003eLight industrial control panel circuit protection\u003c\/li\u003e\n\u003cli\u003eFinal circuit protection for lighting and socket outlet circuits\u003c\/li\u003e\n\u003cli\u003eDIN rail mounted installations requiring compact 17.5 mm wide 1-pole MCB\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229178302747,"sku":"2CDS631031R0254","price":5.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0254-bms311c25-miniature-circuit-breaker_11c7a33c-55bc-4495-8827-e843a2382f0d.webp?v=1777162327"},{"product_id":"abb-2cds631031r0404-bms311c40-1p-40a-mcb","title":"ABB 2CDS631031R0404 BMS311C40 1P 40A 3kA C-Curve 230V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311C40 miniature circuit breaker (MCB), catalog number BMS311C40 and SKU 2CDS631031R0404, is a 1-pole 40A C-curve device rated at 230V AC (IEC 60898-1) and 440V AC (IEC 60947-2), offering a 3kA breaking capacity for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panel applications. Part of the ABB Basic M BMS series, this compact MCB measures just 17.5mm wide and delivers dependable circuit protection with low power dissipation of 4.8W.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311C40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043601\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear — circuit breakers for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage supply system equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General requirements for circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear standard family\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substance safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eLight commercial electrical installations and sub-distribution panels\u003c\/li\u003e\n\u003cli\u003eIndustrial control panels requiring compact 1-pole MCB protection\u003c\/li\u003e\n\u003cli\u003eBranch circuit protection in automation and electrical cabinets\u003c\/li\u003e\n\u003cli\u003eOEM machinery panel boards requiring IEC 60947-2 rated devices\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229178368283,"sku":"2CDS631031R0404","price":6.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0404-bms311c40-miniature-circuit-breaker_cd90273a-8922-4d69-bb22-ab23f9a971b3.webp?v=1777162351"},{"product_id":"abb-2cds631031r0164-bms311c16-1p-16a-mcb","title":"ABB 2CDS631031R0164 BMS311C16 1P 16A 3kA Curve-C Basic M BMS Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311C16 miniature circuit breaker (MCB), SKU 2CDS631031R0164, is a 1-pole, 16A, Curve-C device from the Basic M BMS series, delivering 3 kA breaking capacity at 230V AC per IEC 60898-1. Compact at just 17.5 mm wide, it is engineered for overcurrent and short-circuit protection in residential, commercial, and light industrial distribution boards. The BMS311C16 combines reliable trip performance with low power dissipation of 2.5 W, making it an efficient choice for space-constrained control panels.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311C16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043281\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European standard for insulation coordination\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU chemical safety regulation — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Toxic Substances Control Act — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive — compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229178532123,"sku":"2CDS631031R0164","price":5.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0164-bms311c16-miniature-circuit-breaker_e342cf02-f799-4b83-ab43-da1bea833900.webp?v=1777162303"},{"product_id":"abb-2cds631031r0324-bms311c32-32a-1p-mcb","title":"ABB 2CDS631031R0324 BMS311C32 1P 32A 3kA C-Curve DIN Rail Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311C32 miniature circuit breaker (SKU: 2CDS631031R0324) is a 1-pole, 32 A, C-curve MCB from the Basic M BMS series, designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panels. Rated at 230 V AC per IEC 60898-1 and 440 V AC per IEC 60947-2, the BMS311C32 delivers a breaking capacity of 3 kA and mounts easily on standard DIN rail for quick installation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311C32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043526\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear — circuit breakers for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonized insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear general standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU Regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical installations and consumer units\u003c\/li\u003e\n\u003cli\u003eLight industrial control panels and automation enclosures\u003c\/li\u003e\n\u003cli\u003eProtection of branch circuits in DIN rail-mounted assemblies\u003c\/li\u003e\n\u003cli\u003eMachine control panels requiring compact 1-pole MCB protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229178597659,"sku":"2CDS631031R0324","price":6.28,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0324-bms311c32-miniature-circuit-breaker_f07d8843-67a8-43f4-a453-9fd38e735ff0.webp?v=1777162339"},{"product_id":"abb-2cds631031r0104-bms311c10-1p-10a-mcb","title":"ABB 2CDS631031R0104 BMS311C10 1P 10A 3kA Curve C DIN Rail Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311C10 miniature circuit breaker (MCB), catalog number BMS311C10 (SKU: 2CDS631031R0104), is a 1-pole, 10A, Curve C device from the Basic M BMS series rated at 230 V AC per IEC 60898-1 and 440 V per IEC 60947-2, delivering a breaking capacity of 3 kA at 230\/400 V AC. Designed for DIN rail mounting, the BMS311C10 provides reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panel applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311C10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General circuit breaker standard series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear — circuit breakers (industrial application)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment in low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 on chemical safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229178728731,"sku":"2CDS631031R0104","price":5.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0104-bms311c10-miniature-circuit-breaker_e9982b56-5280-44f8-97ea-eba9595acc69.webp?v=1777162291"},{"product_id":"abb-2cds631031r0204-bms311c20-1p-20a-mcb","title":"ABB 2CDS631031R0204 BMS311C20 1P 20A 3kA C-Curve Basic M BMS Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311C20 (SKU: 2CDS631031R0204) is a 1-pole 20 A C-curve miniature circuit breaker from the Basic M BMS series, designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panel applications. Rated at 230 V AC per IEC 60898-1 and 440 V per IEC 60947-2, it delivers a breaking capacity of 3 kA at 230\/400 V AC, making the BMS311C20 a dependable choice for branch circuit protection across a wide range of installations. With a compact 17.5 mm width and a weight of just 93 g, this ABB miniature circuit breaker fits efficiently on standard DIN rail assemblies.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311C20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0204\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 230\/400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043366\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar installations — circuit breakers for overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers for industrial use\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard for low-voltage equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European adoption of IEC 60664 insulation coordination requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General circuit breaker performance and safety standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear general requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU compliant\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Toxic Substances Control Act — US chemical safety compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant with EU recycling requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eBranch circuit protection in residential distribution boards and consumer units\u003c\/li\u003e\n  \u003cli\u003eCommercial building electrical panels and switchboards\u003c\/li\u003e\n  \u003cli\u003eLight industrial control panels requiring compact, single-pole protection\u003c\/li\u003e\n  \u003cli\u003eMachine tool and automation cabinet wiring where DIN rail mounting is required\u003c\/li\u003e\n  \u003cli\u003eProtection of motors, lighting circuits, and resistive loads with C-curve characteristic\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229178794267,"sku":"2CDS631031R0204","price":5.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0204-bms311c20-miniature-circuit-breaker_c39b12a3-8717-4465-852c-ba092ae7c330.webp?v=1777162315"},{"product_id":"abb-2cds632031r0164-bms312c16-2p-16a-mcb","title":"ABB 2CDS632031R0164 BMS312C16 2P 16A 3kA C-Curve 400V AC DIN Rail Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS312C16 miniature circuit breaker (SKU: 2CDS632031R0164) is a 2-pole, 16 A, C-curve MCB from the Basic M BMS series, rated at 400 V AC with a breaking capacity of 3 kA per IEC 60898-1. Designed for DIN rail installation in residential and light commercial distribution boards, the BMS312C16 delivers reliable overcurrent and short-circuit protection in a compact 35 mm × 88 mm × 69 mm footprint weighing just 186 g.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS312C16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS632031R0164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB Certificate (IEC 60898):\u003c\/strong\u003e IECEE CB Scheme certification for global market acceptance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant for EU market\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU REACH regulation compliance — no substances of very high concern\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eLight commercial and small industrial control panels\u003c\/li\u003e\n\u003cli\u003eBranch circuit protection up to 16 A on 400 V AC networks\u003c\/li\u003e\n\u003cli\u003eDIN rail assemblies requiring a compact 2-pole MCB footprint\u003c\/li\u003e\n\u003cli\u003eRetrofit or new-build installations requiring IEC 60898-1 \/ IEC 60947-2 compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229180039451,"sku":"2CDS632031R0164","price":17.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds632031r0164-bms312c16-miniature-circuit-breaker_78cc8205-0253-4700-8955-22898736cf6c.webp?v=1777162398"},{"product_id":"abb-2cds632031r0204-bms312c20-2p-20a-mcb","title":"ABB 2CDS632031R0204 BMS312C20 2P 20A 3kA 400V AC Miniature Circuit Breaker MCB","description":"\u003cp\u003eThe ABB BMS312C20 miniature circuit breaker (MCB), reference \u003cstrong\u003e2CDS632031R0204\u003c\/strong\u003e, is a 2-pole, 20A device from the ABB Basic M BMS Series designed to provide reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panel applications. Rated at 400V AC per IEC 60898-1 with a breaking capacity of 3 kA, the BMS312C20 offers dependable protection in a compact 35mm × 88mm × 69mm DIN rail-mount form factor weighing just 186 g.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS312C20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS632031R0204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General requirements for miniature circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental protection requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU Regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Compliant with the US Toxic Substances Control Act\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant — supports responsible recycling\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential and commercial distribution boards\u003c\/li\u003e\n\u003cli\u003eControl panel wiring protection in light industrial automation systems\u003c\/li\u003e\n\u003cli\u003eBranch circuit protection for machinery and electrical sub-panels\u003c\/li\u003e\n\u003cli\u003eDIN rail installation in compact enclosures where space efficiency is required\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229180104987,"sku":"2CDS632031R0204","price":17.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds632031r0204-bms312c20-circuit-breaker-mcb_998b8e96-3fb7-4584-9365-153714b2d327.webp?v=1777162404"},{"product_id":"abb-2cds632031r0104-bms312c10-2p-10a-mcb","title":"ABB 2CDS632031R0104 BMS312C10 2P 10A 3kA C-Curve 400V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS312C10 (SKU: 2CDS632031R0104) is a 2-pole 10 A miniature circuit breaker from the Basic M BMS series, rated at 400 V AC with a breaking capacity of 3 kA per IEC 60898-1. Designed for compact installation in residential and light commercial distribution boards, the BMS312C10 delivers reliable overcurrent and short-circuit protection with a C-curve tripping characteristic suited to resistive and moderate inductive loads. Each pole dissipates just 2.1 W, making it an efficient choice for energy-conscious panel designs.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS312C10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS632031R0104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTripping Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043922\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e International standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Industrial low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Low-voltage insulation coordination standard family\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European adoption of IEC 60664 insulation coordination requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit breakers for overcurrent protection — general series standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general standard family\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Compliant with US Toxic Substances Control Act requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant — supports responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eLight commercial and small industrial panel assemblies\u003c\/li\u003e\n\u003cli\u003eFinal circuit protection in control panels and automation cabinets\u003c\/li\u003e\n\u003cli\u003eBranch circuit protection where compact 2-pole, 35 mm width DIN rail mounting is required\u003c\/li\u003e\n\u003cli\u003eOEM equipment where low power dissipation (2.1 W\/pole) and IEC 60898-1 compliance are mandatory\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229180170523,"sku":"2CDS632031R0104","price":17.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds632031r0104-bms312c10-miniature-circuit-breaker_f9b99dca-d7f0-4969-947d-1c3562280b6c.webp?v=1777162392"},{"product_id":"abb-2cds632031r0504-bms312c50-2p-50a-mcb","title":"ABB 2CDS632031R0504 BMS312C50 2P 50A 3kA C-Curve 400V AC DIN Rail Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS312C50 miniature circuit breaker (MCB), catalog number BMS312C50 (SKU 2CDS632031R0504), is a 2-pole, 50 A, C-curve device from the Basic M BMS series rated at 400 V AC with a breaking capacity of 3 kA. Designed for DIN rail installation in residential and light commercial distribution boards, it delivers reliable overcurrent and short-circuit protection in compact control panel applications.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS312C50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS632031R0504\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear — circuit breakers for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Low-voltage system insulation coordination\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Overcurrent protection circuit breaker standard family\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear standard family\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS (EU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863):\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229181514011,"sku":"2CDS632031R0504","price":26.42,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds632031r0504-bms312c50-miniature-circuit-breaker_09b55110-31a9-4327-bb21-41cc0fc4f5ab.webp?v=1777162429"},{"product_id":"abb-2cds632031r0254-bms312c25-2p-25a-mcb","title":"ABB 2CDS632031R0254 BMS312C25 2P 25A 3kA C-Curve 400V AC DIN Rail Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS312C25 miniature circuit breaker (SKU: 2CDS632031R0254) is a 2-pole, 25A, C-curve MCB from the Basic M BMS series, rated at 400V AC with a breaking capacity of 3kA, designed for reliable overcurrent and short-circuit protection in residential and light commercial distribution boards. Engineered to IEC 60898-1 and IEC 60947-2 standards, the BMS312C25 mounts on standard DIN rail and delivers consistent, dependable protection in compact control panel installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS312C25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS632031R0254\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC (IEC 60898-1) \/ 440 V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044165\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e International standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e International standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard series for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General circuit breaker product standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear general rules compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB Certificate (IEC 60898):\u003c\/strong\u003e IECEE CB scheme certification for international market acceptance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006 on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eLight commercial and industrial control panel protection\u003c\/li\u003e\n\u003cli\u003eFinal circuit protection in building electrical installations\u003c\/li\u003e\n\u003cli\u003eDIN rail mounted switchboard applications up to 400V AC\u003c\/li\u003e\n\u003cli\u003eReplacement or upgrade of legacy 2-pole MCBs in existing installations\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229181579547,"sku":"2CDS632031R0254","price":17.62,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds632031r0254-bms312c25-miniature-circuit-breaker_691789e9-a367-4eba-b8cd-1331a230eed0.webp?v=1777162410"},{"product_id":"abb-2cds631031r0504-bms311c50-1p-50a-mcb","title":"ABB 2CDS631031R0504 BMS311C50 1P 50A 3kA Curve-C Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS311C50 miniature circuit breaker (MCB), SKU 2CDS631031R0504, is a 1-pole, 50 A, Curve-C device from the Basic M BMS series, rated at 230 V AC per IEC 60898-1 and 440 V AC per IEC 60947-2, with a breaking capacity of 3 kA. Designed for reliable overload and short-circuit protection in residential, commercial, and light industrial control panels, the BMS311C50 offers compact 17.5 mm DIN rail mounting and straightforward installation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311C50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0504\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043687\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar installations — circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS (EU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863):\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e EU Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOverload and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical panels and final circuits\u003c\/li\u003e\n\u003cli\u003eLight industrial control panels and machinery protection\u003c\/li\u003e\n\u003cli\u003eProtection of single-phase loads, lighting circuits, and socket outlet circuits\u003c\/li\u003e\n\u003cli\u003eDIN rail assembly in compact enclosures where 17.5 mm width is essential\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229181645083,"sku":"2CDS631031R0504","price":7.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0504-bms311c50-miniature-circuit-breaker_4c9150dc-d339-4694-9b07-afc1d8bdff0d.webp?v=1777162362"},{"product_id":"abb-2cds631031r0634-bms311c63-1p-63a-3ka-mcb","title":"ABB 2CDS631031R0634 BMS311C63 1P 63A 3kA Curve-C Miniature Circuit Breaker MCB Basic M BMS","description":"\u003cp\u003eThe ABB BMS311C63 miniature circuit breaker (MCB), SKU 2CDS631031R0634, is a 1-pole 63 A Curve-C device from the Basic M BMS series, rated for 230 V AC per IEC 60898-1 and 440 V per IEC 60947-2, delivering a breaking capacity of 3 kA. Designed for reliable overcurrent and short-circuit protection in residential, commercial, and light-industrial control panel installations, the BMS311C63 offers a compact 17.5 mm wide footprint that makes efficient use of DIN rail space.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS311C63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS631031R0634\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS (EU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863):\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e EU Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e U.S. Toxic Substances Control Act compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical panels and sub-distribution boards\u003c\/li\u003e\n\u003cli\u003eLight-industrial control panels and machinery protection\u003c\/li\u003e\n\u003cli\u003eSingle-phase branch circuit protection at 230 V AC\u003c\/li\u003e\n\u003cli\u003eIndustrial automation cabinets requiring compact 17.5 mm-wide DIN rail MCBs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229182890267,"sku":"2CDS631031R0634","price":8.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds631031r0634-bms311c63-basic-m-bms_0fc7af20-adca-477e-a472-35033cc546d5.webp?v=1777162374"},{"product_id":"abb-2cds632031r0064-bms312c06-2p-6a-mcb","title":"ABB 2CDS632031R0064 BMS312C06 2P 6A 3kA C-Curve 400V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS312C06 miniature circuit breaker (MCB), catalog number \u003cstrong\u003eBMS312C06\u003c\/strong\u003e (SKU: 2CDS632031R0064), is a compact 2-pole, 6 A, C-curve device from the Basic M BMS series, rated at 400 V AC per IEC 60898-1 and 440 V AC per IEC 60947-2. Delivering a breaking capacity of 3 kA at 400 V AC, it provides reliable overcurrent and short-circuit protection for residential, commercial, and light industrial distribution boards and control panels.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS312C06\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS632031R0064\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779043847\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear — circuit breakers for industrial applications\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Compliant with EU machinery and low-voltage directives\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Compliant with EU Directive 2011\/65\/EU and Amendment 2015\/863 — restriction of hazardous substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection in residential and commercial distribution boards\u003c\/li\u003e\n  \u003cli\u003eIndustrial control panels and machine automation cabinets\u003c\/li\u003e\n  \u003cli\u003eLight commercial HVAC and building services circuits\u003c\/li\u003e\n  \u003cli\u003eProtection of branch circuits in low-voltage switchgear assemblies\u003c\/li\u003e\n  \u003cli\u003eDIN rail mounting in compact enclosures where 35 mm width per 2 poles is required\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229182988571,"sku":"2CDS632031R0064","price":21.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds632031r0064-bms312c06-miniature-circuit-breaker_dfe95909-bdbc-4d0d-99d1-07ab911b09e9.webp?v=1777162386"},{"product_id":"abb-2cds632031r0404-bms312c40-2p-40a-mcb","title":"ABB 2CDS632031R0404 BMS312C40 2P 40A 3kA C-Curve 400V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS312C40 miniature circuit breaker (SKU: 2CDS632031R0404) is a 2-pole, 40A, C-curve MCB from the Basic M BMS series, rated at 400V AC with a breaking capacity of 3 kA per IEC 60898-1. Designed for residential, commercial, and light industrial control panel applications, the BMS312C40 delivers reliable overload and short-circuit protection in a compact 35mm × 88mm × 69mm DIN-rail mount housing weighing just 186g.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS312C40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS632031R0404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.8 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar installations — miniature circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant disposal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Toxic Substances Control Act — US chemical compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOverload and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical panel protection\u003c\/li\u003e\n\u003cli\u003eLight industrial control panel branch circuit protection\u003c\/li\u003e\n\u003cli\u003eDIN rail mounted switchgear assemblies up to 400V AC\u003c\/li\u003e\n\u003cli\u003eFinal circuit protection in low-voltage switchgear and controlgear assemblies\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229183054107,"sku":"2CDS632031R0404","price":22.92,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds632031r0404-bms312c40-miniature-circuit-breaker_e6d82ccd-df1b-43b9-b792-08f7debca669.webp?v=1777162423"},{"product_id":"abb-2cds632031r0324-bms312c32-2p-32a-mcb","title":"ABB 2CDS632031R0324 BMS312C32 2P 32A 3kA C-Curve 400V Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS312C32 miniature circuit breaker (SKU: 2CDS632031R0324) is a 2-pole, 32A, C-curve MCB from the Basic M BMS series, rated at 400V AC with a breaking capacity of 3kA. Designed for reliable overcurrent and short-circuit protection in residential and light commercial installations, it delivers dependable performance in compact control panel environments.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS312C32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS632031R0324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e International standard for household and similar installations circuit-breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e International standard for low-voltage switchgear — circuit-breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB Certificate (IEC 60898):\u003c\/strong\u003e International CB Scheme certification for circuit-breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant for EU markets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment directive — compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eLight commercial and industrial control panels requiring compact 2-pole protection\u003c\/li\u003e  \u003cli\u003eFinal circuit protection in building automation and HVAC systems\u003c\/li\u003e\n\u003cli\u003eDIN rail-mounted installations in switchgear panels and enclosures\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229183119643,"sku":"2CDS632031R0324","price":22.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds632031r0324-bms312c32-miniature-circuit-breaker_d40ad874-d094-4adf-9158-4753f59863bf.webp?v=1777162417"},{"product_id":"abb-2cds633031r0324-bms313c32-3p-32a-mcb","title":"ABB 2CDS633031R0324 BMS313C32 3P 32A C-Curve 3kA 400V Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS313C32 miniature circuit breaker (SKU: 2CDS633031R0324) is a 3-pole, 32A, C-curve MCB from the Basic M BMS series, delivering reliable overcurrent and short-circuit protection with a 3 kA breaking capacity at 400V AC per IEC 60898-1. Compact and DIN-rail mountable, the BMS313C32 is engineered for distribution boards and control panels in commercial and light industrial installations where dependable circuit protection is essential.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313C32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044967\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB Certificate (IEC 60898):\u003c\/strong\u003e International CB Scheme certification for circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH Regulation (EC) No 1907\/2006\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Compliant with EU Waste Electrical and Electronic Equipment Directive\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential and commercial distribution boards\u003c\/li\u003e\n\u003cli\u003eControl panel circuit protection in light industrial and building automation systems\u003c\/li\u003e\n\u003cli\u003eBranch circuit protection for motors, lighting, and general loads with C-curve characteristics\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounted installations in switchgear enclosures and consumer units\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229183185179,"sku":"2CDS633031R0324","price":28.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0324-bms313c32-miniature-circuit-breaker_fb0c80b7-24ed-43d0-94f8-51c104268861.webp?v=1777162499"},{"product_id":"abb-2cds633031r0204-bms313c20-3p-20a-mcb","title":"ABB 2CDS633031R0204 BMS313C20 3P 20A 3kA C-Curve 400V AC DIN Rail Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS313C20 miniature circuit breaker (MCB), reference 2CDS633031R0204, is a 3-pole, 20A, C-curve device from the Basic M BMS series designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panels. Rated at 400V AC per IEC 60898-1 and 440V per IEC 60947-2, the BMS313C20 delivers a breaking capacity of 3 kA at 400V AC, making it well suited to protecting circuits where moderate fault currents are expected. Its compact DIN rail mount form factor — 52.5 mm × 88 mm × 69 mm and weighing just 279 g — ensures easy installation in space-constrained enclosures.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313C20\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0204\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044806\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for household and similar installations — circuit breakers for overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers (industrial applications)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage supply systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General circuit breaker performance standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Toxic Substances Control Act — US chemical compliance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — proper end-of-life disposal compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection in commercial and light industrial distribution boards\u003c\/li\u003e\n  \u003cli\u003eProtection of motor branch circuits and control panel feeders up to 20A\u003c\/li\u003e\n  \u003cli\u003eMachine building and OEM panel wiring requiring IEC 60947-2 rated devices\u003c\/li\u003e\n  \u003cli\u003eResidential and small commercial installations where a C-curve characteristic is required\u003c\/li\u003e\n  \u003cli\u003eDIN rail assemblies in automation cabinets, HVAC control panels, and building management systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229183283483,"sku":"2CDS633031R0204","price":22.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0204-bms313c20-miniature-circuit-breaker_51221f06-b270-497a-8354-0393b293d4b3.webp?v=1777162473"},{"product_id":"abb-2cds633031r0634-bms313c63-3p-63a-mcb","title":"ABB 2CDS633031R0634 BMS313C63 3P 63A 3kA C-Curve 400V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS313C63 miniature circuit breaker (SKU: 2CDS633031R0634) is a 3-pole, 63 A, C-curve MCB from the Basic M BMS series, rated at 400 V AC per IEC 60898-1 with a breaking capacity of 3 kA. Designed for reliable overcurrent and short-circuit protection in residential, commercial, and light-industrial control panels, the BMS313C63 combines compact dimensions (52.5 × 88 × 69 mm) with robust IEC-compliant performance, making it a dependable choice for distribution boards and motor branch circuits alike.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313C63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0634\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779045209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear — circuit breakers for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General series standard for overcurrent protective circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e General series standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS (EU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863):\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste electrical and electronic equipment directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential and commercial distribution boards\u003c\/li\u003e\n\u003cli\u003eBranch circuit protection for lighting, heating, and general-purpose loads\u003c\/li\u003e\n\u003cli\u003eMotor branch circuit protection in light-industrial control panels\u003c\/li\u003e\n\u003cli\u003eRetrofit or upgrade of existing 3-pole MCB installations requiring IEC 60898-1 \/ IEC 60947-2 compliance\u003c\/li\u003e\n\u003cli\u003eMachine building and OEM panel assemblies requiring compact, DIN-rail-mounted protection devices\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229183349019,"sku":"2CDS633031R0634","price":38.52,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0634-bms313c63-miniature-circuit-breaker_bed6705d-2c09-4e56-a634-d296b8eff70f.webp?v=1777162532"},{"product_id":"abb-2cds633031r0064-bms313c06-3p-6a-mcb","title":"ABB 2CDS633031R0064 BMS313C06 3P 6A 3kA Curve-C 400V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS313C06 miniature circuit breaker (MCB), reference 2CDS633031R0064, is a 3-pole, 6 A, Curve-C device from the Basic M BMS series rated at 400 V AC with a breaking capacity of 3 kA, delivering reliable overcurrent and short-circuit protection for industrial control panels and distribution boards. Compliant with IEC 60898-1 and IEC 60947-2, the BMS313C06 is designed for demanding installation environments where compact, cost-effective circuit protection is essential.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313C06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0064\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTripping Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC (IEC 60898-1) \/ 440 V (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044561\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar installations — circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e General insulation coordination standard for low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General circuit breaker standard for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear general requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — SVHC compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant with EU 2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in industrial control panels and machine builders' switchboards\u003c\/li\u003e\n\u003cli\u003eBranch circuit protection in commercial and light industrial distribution boards\u003c\/li\u003e\n\u003cli\u003eMotor feeder protection where Curve-C characteristics match moderate inrush currents\u003c\/li\u003e\n\u003cli\u003eDIN rail installation in compact enclosures with space constraints\u003c\/li\u003e\n\u003cli\u003eOEM equipment builds requiring cost-effective IEC-certified MCBs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229183480091,"sku":"2CDS633031R0064","price":27.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0064-bms313c06-miniature-circuit-breaker_1949ee6d-00ac-460e-b35d-709c3beef076.webp?v=1777162442"},{"product_id":"abb-2cds633031r0404-bms313c40-3p-40a-mcb","title":"ABB 2CDS633031R0404 BMS313C40 3P 40A 3kA C-Curve DIN Rail Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS313C40 miniature circuit breaker (SKU: 2CDS633031R0404) is a 3-pole, 40A, C-curve MCB from the Basic M BMS series, rated at 400V AC with a breaking capacity of 3kA, designed for reliable overcurrent and short-circuit protection in residential and light commercial installations. Mounted on a standard DIN rail, this compact breaker measures 52.5 × 88 × 69 mm and weighs just 279g, making it ideal for space-efficient control panel builds. Compliant with IEC 60898-1 and IEC 60947-2, the BMS313C40 meets the demands of modern electrical installations.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313C40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779045049\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC (IEC 60898-1) \/ 440 V AC (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.8 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised standard for insulation coordination\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit breakers for overcurrent protection — general series compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant for use in the European Union\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — compliant disposal and recycling\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229183578395,"sku":"2CDS633031R0404","price":29.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0404-bms313c40-miniature-circuit-breaker_40381995-2a0f-4ea0-9a99-85e63d4fcf21.webp?v=1777162511"},{"product_id":"abb-2cds633031r0164-bms313c16-3p-16a-mcb","title":"ABB 2CDS633031R0164 BMS313C16 3P 16A 3kA C-Curve 400V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS313C16 miniature circuit breaker (MCB), reference \u003cstrong\u003e2CDS633031R0164\u003c\/strong\u003e, is a 3-pole, 16 A, C-curve device from the Basic M BMS series, rated for 400 V AC per IEC 60898-1 and 440 V AC per IEC 60947-2, delivering a breaking capacity of 3 kA at 400 V AC. Designed for reliable overcurrent and short-circuit protection in residential, commercial, and light-industrial control panels, the BMS313C16 combines compact 52.5 × 88 × 69 mm dimensions with a 279 g form factor that fits easily on standard DIN rail assemblies.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313C16\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0164\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044721\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar circuit breakers for overcurrent protection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage systems (general)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health and environmental requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals (EU)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Toxic Substances Control Act compliance (US)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — proper end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eOvercurrent and short-circuit protection in residential and commercial distribution boards\u003c\/li\u003e\n  \u003cli\u003eProtection of motor branch circuits and general-purpose loads with C-curve trip characteristic\u003c\/li\u003e\n  \u003cli\u003eLight-industrial control panels and automation enclosures requiring compact 3-pole MCBs\u003c\/li\u003e\n  \u003cli\u003eBuilding services installations compliant with IEC 60898-1 and IEC 60947-2\u003c\/li\u003e\n  \u003cli\u003eDIN rail assemblies in switchboards up to 400 V \/ 440 V AC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229183643931,"sku":"2CDS633031R0164","price":22.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0164-bms313c16-miniature-circuit-breaker_ffdbbdb1-6938-4478-a244-d4643fc3c05d.webp?v=1777162467"},{"product_id":"abb-2cds632031r0634-bms312c63-2p-63a-mcb","title":"ABB 2CDS632031R0634 BMS312C63 2P 63A 3kA C-Curve 400V DIN Rail Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS312C63 miniature circuit breaker (MCB), SKU 2CDS632031R0634, is a 2-pole, 63 A, C-curve device from ABB's Basic M BMS series, rated for 400 V AC per IEC 60898-1 and 440 V per IEC 60947-2, delivering a breaking capacity of 3 kA. Designed for DIN rail installation in residential distribution boards and light commercial panels, the BMS312C63 provides reliable overcurrent and short-circuit protection in compact enclosures.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS312C63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS632031R0634\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTripping Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044486\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breaker performance standard for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Industrial low-voltage switchgear standard for circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS (EU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863):\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e EU Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229183709467,"sku":"2CDS632031R0634","price":29.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds632031r0634-bms312c63-miniature-circuit-breaker_5bc6cdb7-580f-47bf-a16e-e59463803e55.webp?v=1777162435"},{"product_id":"abb-2cds633031r0504-bms313c50-3p-50a-mcb","title":"ABB 2CDS633031R0504 BMS313C50 3P 50A 3kA Curve C 400V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS313C50 miniature circuit breaker (MCB), SKU 2CDS633031R0504, is a 3-pole, 50A, Curve C device rated at 400V AC with a breaking capacity of 3kA, designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panels. Part of the ABB Basic M BMS series, the BMS313C50 combines compact dimensions of 52.5mm × 88mm × 69mm with a weight of just 279g, making it an efficient and space-saving solution for distribution boards and motor branch circuits.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313C50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0504\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTripping Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779045124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB Certificate (IEC 60898):\u003c\/strong\u003e International CB scheme certification for circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear general requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS (EU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863):\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliance with EU regulation on chemicals (ECHA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste electrical and electronic equipment directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229183775003,"sku":"2CDS633031R0504","price":34.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0504-bms313c50-miniature-circuit-breaker_e912f338-0ad1-4a12-8d67-91b46656fe3f.webp?v=1777162525"},{"product_id":"abb-2cds633031r0104-bms313c10-3p-10a-mcb","title":"ABB 2CDS633031R0104 BMS313C10 3P 10A 3kA C-Curve 400V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS313C10 (SKU: 2CDS633031R0104) is a 3-pole 10A C-curve miniature circuit breaker (MCB) from the Basic M BMS series, rated at 400V AC with a breaking capacity of 3 kA per IEC 60898-1. Designed for reliable overload and short-circuit protection in residential, commercial, and light industrial control panels, the BMS313C10 delivers dependable performance in a compact 52.5 × 88 × 69 mm enclosure weighing just 279 g.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313C10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044646\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant, restricting use of specified hazardous materials in electrical equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU chemical safety regulation compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Toxic Substances Control Act — compliant with US chemical substance regulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — product is WEEE compliant for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOverload and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical panel protection\u003c\/li\u003e\n\u003cli\u003eLight industrial control panel branch circuit protection\u003c\/li\u003e\n\u003cli\u003eDIN rail mounted installations requiring compact 3-pole MCB solutions\u003c\/li\u003e\n\u003cli\u003eMachine and equipment protection where IEC 60947-2 compliance is required\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229183873307,"sku":"2CDS633031R0104","price":22.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0104-bms313c10-miniature-circuit-breaker_3758368c-b5de-49e5-9bf1-14e2c83ddbcc.webp?v=1777162454"},{"product_id":"abb-2cds633031r0254-bms313c25-3p-25a-mcb","title":"ABB 2CDS633031R0254 BMS313C25 3P 25A 3kA C-Curve 400V DIN Rail Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS313C25 miniature circuit breaker (SKU: 2CDS633031R0254) is a 3-pole, 25A, C-curve MCB from the Basic M BMS series, rated at 400V AC with a 3kA breaking capacity per IEC 60898-1. Designed for DIN rail installation in residential, commercial, and light industrial control panels, it delivers reliable overcurrent and short-circuit protection with a compact 52.5mm × 88mm × 69mm footprint and a weight of just 279g.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS313C25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS633031R0254\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC (IEC 60898-1) \/ 440 V (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52.5 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779044882\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar installations — miniature circuit breakers for AC operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers (industrial)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment (general series)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit breakers for overcurrent protection in household installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear — general requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Toxic Substances Control Act — US chemical regulatory compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — EU compliant for end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229183938843,"sku":"2CDS633031R0254","price":22.66,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds633031r0254-bms313c25-miniature-circuit-breaker_ecefde0a-c663-45c1-b216-b2b02ddb64a9.webp?v=1777162486"},{"product_id":"abb-2cds634031r0064-bms314c06-4p-6a-3ka-mcb","title":"ABB 2CDS634031R0064 BMS314C06 4P 6A 3kA Curve-C DIN Rail Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS314C06 miniature circuit breaker (MCB), SKU 2CDS634031R0064, is a 4-pole, 6 A, Curve-C device rated at 400 V AC with a breaking capacity of 3 kA — delivering reliable overcurrent and short-circuit protection for residential, commercial, and light-industrial distribution boards. Part of ABB's Basic M BMS series, the BMS314C06 complies with both IEC 60898-1 and IEC 60947-2, making it suitable for a wide range of panel-building applications. Its compact DIN-rail design (70 mm × 88 mm × 69 mm, 372 g) fits neatly into standard enclosures with a power dissipation of just 2 W per pole.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS314C06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS634031R0064\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779045285\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC (IEC 60898-1) \/ 440 V (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e372 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar installations — circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers for industrial use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS (EU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863):\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste electrical and electronic equipment directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in 4-wire (3-phase + neutral) distribution circuits\u003c\/li\u003e\n\u003cli\u003eResidential and commercial distribution boards requiring simultaneous all-pole disconnection\u003c\/li\u003e\n\u003cli\u003eLight-industrial control panels and machine building where IEC 60947-2 compliance is required\u003c\/li\u003e\n\u003cli\u003eBuilding automation and HVAC distribution sub-circuits\u003c\/li\u003e\n\u003cli\u003ePanel builders seeking a compact, DIN-rail-mounted 4P MCB with Curve-C characteristics for motor or transformer loads\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229184004379,"sku":"2CDS634031R0064","price":36.28,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds634031r0064-bms314c06-miniature-circuit-breaker_215244b5-a384-4ea4-9bf8-c566f944c754.webp?v=1777162537"},{"product_id":"abb-2cds634031r0324-bms314c32-4p-32a-mcb","title":"ABB 2CDS634031R0324 BMS314C32 4P 32A 3kA C-Curve Miniature Circuit Breaker Basic M BMS Series","description":"\u003cp\u003eThe ABB BMS314C32 miniature circuit breaker (MCB), SKU 2CDS634031R0324, is a 4-pole 32 A C-curve device from the Basic M BMS series, rated at 400 V AC per IEC 60898-1 and delivering a 3 kA breaking capacity at 400 V AC. Designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial distribution boards, the BMS314C32 combines compact dimensions with robust performance to simplify panel design and installation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS314C32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS634031R0324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e372 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779045681\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar installations — miniature circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard for low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals (EU regulation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Toxic Substances Control Act — compliant with US chemical safety regulations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential and commercial distribution boards\u003c\/li\u003e\n\u003cli\u003eProtection of branch circuits in light industrial control panels\u003c\/li\u003e\n\u003cli\u003eBuilding automation and HVAC electrical distribution systems\u003c\/li\u003e\n\u003cli\u003eSub-distribution boards in multi-storey residential and office buildings\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose 4-pole protection where neutral switching is required\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229184135451,"sku":"2CDS634031R0324","price":37.8,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds634031r0324-bms314c32-m-bms-series_3b3ed25b-3c1b-4e85-bdf1-1710878ff7a7.webp?v=1777162570"},{"product_id":"abb-2cds634031r0504-bms314c50-4p-50a-mcb","title":"ABB 2CDS634031R0504 BMS314C50 4P 50A 3kA 400V DIN Rail Miniature Circuit Breaker (MCB)","description":"\u003cp\u003eThe ABB BMS314C50 miniature circuit breaker (MCB), SKU 2CDS634031R0504, is a 4-pole, 50 A device from the Basic M BMS series rated at 400 V AC with a breaking capacity of 3 kA, designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial distribution boards. Mounted on standard DIN rail, the BMS314C50 complies with IEC 60898-1 and IEC 60947-2, making it a trusted choice for engineers and procurement professionals specifying protection devices for control panels and final circuits.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS314C50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS634031R0504\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779045841\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e372 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear — circuit breakers for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e General series standard for circuit breakers used in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e General series standard for low-voltage switchgear and controlgear\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS (EU Directive 2011\/65\/EU \u0026amp; Amendment 2015\/863):\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e EU Waste Electrical and Electronic Equipment Directive — compliant for responsible end-of-life disposal\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229184200987,"sku":"2CDS634031R0504","price":45.36,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds634031r0504-bms314c50-circuit-breaker-mcb_79d42ef2-5d44-46f8-b0ef-e63586bb88f4.webp?v=1777162582"},{"product_id":"abb-2cds634031r0204-bms314c20-4p-20a-mcb","title":"ABB 2CDS634031R0204 BMS314C20 4P 20A 3kA C-Curve 400V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS314C20 (SKU: 2CDS634031R0204) is a 4-pole, 20A miniature circuit breaker (MCB) from the Basic M BMS series, rated at 400V AC with a breaking capacity of 3 kA per IEC 60898-1. Designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panels, the BMS314C20 delivers consistent performance in compact installations requiring multi-pole protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS314C20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS634031R0204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779045520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTripping Characteristic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC-Curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e372 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar installations — circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear — circuit breakers for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European Conformity — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Toxic Substances Control Act compliance (USA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229184266523,"sku":"2CDS634031R0204","price":30.22,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds634031r0204-bms314c20-miniature-circuit-breaker_9ba3b5cf-0b35-4f7b-8b68-7a7e1e74e743.webp?v=1777162556"},{"product_id":"abb-2cds634031r0254-bms314c25-4p-25a-mcb","title":"ABB 2CDS634031R0254 BMS314C25 4P 25A 3kA C-Curve Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS314C25 miniature circuit breaker (MCB), reference 2CDS634031R0254, is a 4-pole, 25 A, C-curve device from the Basic M BMS series delivering reliable overcurrent and short-circuit protection at 400 V AC (IEC 60898-1) and 440 V AC (IEC 60947-2) with a breaking capacity of 3 kA. Designed for industrial control panels and commercial distribution boards, the BMS314C25 offers compact dimensions of 70 × 88 × 69 mm and a rated power dissipation of just 3.2 W per pole, making it an efficient and space-saving solution for four-wire circuit protection.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS314C25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS634031R0254\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400 V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 × 88 × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e372 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779045605\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e European conformity marking for health, safety, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU REACH regulation on chemical substances\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Compliant with US Toxic Substances Control Act\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229184430363,"sku":"2CDS634031R0254","price":30.22,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds634031r0254-bms314c25-miniature-circuit-breaker_bf7c7e06-69dd-48b1-9205-0d1a7542a889.webp?v=1777162563"},{"product_id":"abb-2cds634031r0164-bms314c16-4p-16a-3ka-mcb","title":"ABB 2CDS634031R0164 BMS314C16 4P 16A 3kA C-Curve 400V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS314C16 miniature circuit breaker (SKU: 2CDS634031R0164) is a 4-pole, 16 A, C-curve MCB from the Basic M BMS series, rated at 400 V AC per IEC 60898-1 and 440 V AC per IEC 60947-2, with a breaking capacity of 3 kA at 400 V AC. Designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panels, the BMS314C16 delivers dependable performance in a compact 70 × 88 × 69 mm DIN-rail-mount package.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS314C16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS634031R0164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN \/ Barcode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779045445\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 W per pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e372 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Standard for circuit breakers for overcurrent protection for household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Standard for low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCB Certificate (IEC 60898 \/ IEC 60947):\u003c\/strong\u003e International CB Scheme certification confirming global safety compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European harmonised insulation coordination standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne marking — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Compliant with EU Regulation (EC) No 1907\/2006 on chemical substance safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive compliant — supports responsible end-of-life recycling\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential distribution boards\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical panel protection up to 16 A loads\u003c\/li\u003e\n\u003cli\u003eLight industrial control panels and machinery protection\u003c\/li\u003e\n\u003cli\u003eMotor branch circuit protection where C-curve inrush tolerance is required\u003c\/li\u003e\n\u003cli\u003e4-pole applications requiring simultaneous disconnection of all live conductors including neutral\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229184495899,"sku":"2CDS634031R0164","price":30.22,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds634031r0164-bms314c16-miniature-circuit-breaker_b363da5b-84e0-4474-b019-91a895e93c7c.webp?v=1777162550"},{"product_id":"abb-2cds634031r0634-bms314c63-4p-63a-mcb","title":"ABB 2CDS634031R0634 BMS314C63 4P 63A 3kA C-Curve Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS314C63 miniature circuit breaker (SKU: 2CDS634031R0634) is a 4-pole, 63A, C-curve MCB from the Basic M BMS series, rated at 400V AC with a 3kA breaking capacity per IEC 60898-1. Designed for reliable overcurrent and short-circuit protection in residential, commercial, and light industrial control panels, the BMS314C63 delivers dependable performance in a compact 70mm × 88mm × 69mm DIN-rail-mount footprint weighing just 372g.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS314C63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS634031R0634\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA @ 400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e372 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779045926\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Miniature circuit breakers for overcurrent protection in household and similar installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear — circuit breakers for industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage supply systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination standard for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898:\u003c\/strong\u003e Circuit breaker standard for household and similar use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947:\u003c\/strong\u003e Low-voltage switchgear and controlgear general standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEN 60664:\u003c\/strong\u003e European standard for insulation coordination in low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS (EU Directive 2011\/65\/EU and Amendment 2015\/863):\u003c\/strong\u003e Restriction of hazardous substances in electrical and electronic equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e EU regulation on registration, evaluation, authorisation and restriction of chemicals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e EU Waste Electrical and Electronic Equipment Directive compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Toxic Substances Control Act (US) compliance\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications \u0026amp; Use Cases\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOvercurrent and short-circuit protection in residential and commercial distribution boards\u003c\/li\u003e\n\u003cli\u003eIndustrial control panel circuit protection for 400V AC systems\u003c\/li\u003e\n\u003cli\u003e4-pole switching for three-phase + neutral circuits\u003c\/li\u003e\n\u003cli\u003eLight industrial machinery and equipment protection\u003c\/li\u003e\n\u003cli\u003eBuilding automation and HVAC electrical panel protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229184561435,"sku":"2CDS634031R0634","price":51.38,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds634031r0634-bms314c63-miniature-circuit-breaker_14962799-ba92-473f-87fc-ba4ca75382f4.webp?v=1777162589"},{"product_id":"abb-2cds634031r0104-bms314c10-4p-10a-mcb","title":"ABB 2CDS634031R0104 BMS314C10 4P 10A 3kA C-Curve 400V AC Miniature Circuit Breaker","description":"\u003cp\u003eThe ABB BMS314C10 miniature circuit breaker (MCB), SKU 2CDS634031R0104, is a 4-pole, 10 A, C-curve device rated at 400 V AC with a breaking capacity of 3 kA, designed for reliable overload and short-circuit protection in residential, commercial, and light industrial control panels. Part of ABB's Basic M BMS series, the BMS314C10 delivers proven IEC 60898-1 and IEC 60947-2 performance in a compact 70 × 88 × 69 mm footprint weighing just 372 g.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBMS314C10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2CDS634031R0104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic M BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60898-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage (IEC 60947-2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity (Icu @ 400V AC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower per Pole\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm × 88 mm × 69 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e372 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4016779045360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60898-1:\u003c\/strong\u003e Household and similar installations — circuit breakers for overcurrent protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60947-2:\u003c\/strong\u003e Low-voltage switchgear and controlgear — circuit breakers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664-1:\u003c\/strong\u003e Insulation coordination for equipment within low-voltage systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60664:\u003c\/strong\u003e Insulation coordination for low-voltage equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e Conformité Européenne — meets EU safety, health, and environmental requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS:\u003c\/strong\u003e Restriction of Hazardous Substances — compliant with EU Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH:\u003c\/strong\u003e Registration, Evaluation, Authorisation and Restriction of Chemicals — EU SVHC compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTSCA:\u003c\/strong\u003e Toxic Substances Control Act — compliant with US chemical regulations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE:\u003c\/strong\u003e Waste Electrical and Electronic Equipment Directive — proper disposal compliance\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50229184626971,"sku":"2CDS634031R0104","price":30.22,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/abb-2cds634031r0104-bms314c10-miniature-circuit-breaker_c35a6323-6f6f-41d2-8454-ec37e56b485b.webp?v=1777162544"}],"url":"https:\/\/stoklink.com\/collections\/abb-basic-m-mcb.oembed?page=3","provider":"Stoklink","version":"1.0","type":"link"}