Schneider Electric ATS01 Soft Starter Series – Overview
Schneider Electric ATS01 soft starters are compact and cost-effective motor starting solutions designed for basic soft starting of asynchronous motors in standard industrial applications. The ATS01 series focuses on reducing mechanical stress and limiting starting current during motor acceleration, offering a simple and reliable alternative to direct-on-line starting. With a straightforward design and minimal configuration requirements, ATS01 soft starters are well suited for pumps, fans, compressors, and other simple motor-driven machines where basic motor starting control is sufficient.
Product Description: Schneider Electric ATS01N112FT
The Schneider Electric ATS01N112FT is a compact ATS01-series motor soft starter with a rated operational current of 12 A and a wide supply voltage range (nominally 110…480 V). It is sized for small to medium asynchronous motors — typical in-line motor ratings quoted for this model include approximately 1.5 kW for single-phase 230 V motors, 2.2 kW for three-phase 230 V motors and up to 5.5 kW for three-phase 400 V motors (manufacturer power-range groupings also list 1.1–2 kW at 200–240 V 1‑phase, 2.2–3 kW at 200–240 V 3‑phase and 4–6 kW at 380–440 V 3‑phase). The device uses a voltage-ramp soft start (start with voltage ramp) with adjustable starting time (1 to 5 s) to limit inrush current and reduce mechanical stress during acceleration. The ATS01N112FT includes an internal bypass to reduce heat dissipation once the motor reaches speed and is designed for simple machine applications — pumps, fans and compressors — where basic soft starting and low-configuration operation are required. It is a compact, IP20-protected unit with no integrated motor overload relay, and it accepts common control supply voltages (control supply options include 110–240 V AC and 24 V DC as specified by Schneider Electric).
Key Soft Starter Attributes
- Rated Operational Current (Ie): 12 A
- Motor Power Range: 1.1–2 kW (200–240 V 1‑phase); 2.2–3 kW (200–240 V 3‑phase); 4–6 kW (380–440 V 3‑phase). Manufacturer examples: 1.5 kW (1‑phase 230 V), 2.2 kW (3‑phase 230 V), 5.5 kW (3‑phase 400 V).
- Supply Voltage: 110…480 V (nominal supply range)
- Control Method: Voltage ramp (start with voltage ramp), adjustable start time 1–5 s
- Built-in Bypass: Yes (internal bypass)
- Motor Protection Functions: No integrated motor overload protection (requires external protection)
- Control Supply Voltage: 110–240 V AC and 24 V DC (control supply options)
- Enclosure / Protection Class: IP20
Frequently Asked Questions (FAQ)
What motor sizes does the ATS01N112FT support?
The ATS01N112FT is specified for small to medium motors: manufacturer power-groupings cover roughly 1.1–2 kW (200–240 V single‑phase), 2.2–3 kW (200–240 V three‑phase) and 4–6 kW (380–440 V three‑phase); example ratings cited include 1.5 kW (230 V 1‑ph), 2.2 kW (230 V 3‑ph) and 5.5 kW (400 V 3‑ph).
What is the supply voltage range for this soft starter?
The unit accepts a wide supply voltage range: nominal 110…480 V (suitable for 110–480 V networks as specified by Schneider Electric).
Does the ATS01N112FT include motor overload protection?
No. The ATS01N112FT does not include integrated motor overload protection; an external overload or motor protector must be used where required.
Can I adjust starting behavior (time/torque)?
Yes. The starter uses a voltage-ramp start with adjustable starting time (adjustable from 1 to 5 seconds) to tailor acceleration and limit inrush current.
Is there a bypass after starting to reduce heat?
Yes. The ATS01N112FT includes an internal bypass to reduce dissipation and noise after the motor reaches running speed.